5830--communication & messaging system for the william S. Middleton MVH located in madison, wisconsin. Brand name (VOCERA) or equal

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C25221Q0976
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 12 seeks a communication and messaging system including software licenses, hardware, maintenance and support services for the William S. Middleton Memorial Veterans Hospital in Madison, Wisconsin. Interested firms must provide a Vocera brand or equal system meeting detailed requirements. Responses are due by July 27, 2021 and must include company information, qualifications, and documentation of authorization to provide the specified Vocera system. The resulting order will be a base year plus four one-year options.

There is no set-aside designation. The applicable NAICS code is 334220 for radio and television broadcasting and wireless communications equipment manufacturing with a size standard of 1,250 employees. Firms qualifying as a service-disabled veteran-owned small business, veteran-owned small business, small business or other than small business may respond. The requirements include 150 software licenses, hardware such as 140 badges and accessories, and maintenance/support for the base year plus four option years.

Notice text

THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.

The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide a COMMUNICATION & MESSAGING SYSTEM (including Software Licenses, Hardware and Software Maintenance and Support Services) VOCERA Brand Name or Equal for the William S. Middleton Memorial Veterans Hospital (Madison MVH) in Madison, Wisconsin. The resulting order will be a base plus four one-year options.

Requirements:

COMMUNICATION & MESSAGING SYSTEM (including Software Licenses, Hardware and Software Maintenance and Support Services) VOCERA Brand Name or Equal.

PART NUMBER

DESCRIPTION

QUANTITY

SOFTWARE

900-01572

Vocera Enterprise License - Voice, 150 Users, NA.

1

900-02060

Vocera Messaging, 50 users.

1

900-04165

Software License, Vocera Platform.

1

900-01862

Vocera Analytics License.

1

900-01101

SIP Telephony, 6-ports.

4

HARDWARE

220-01576

B3000n, Dual-Band, White Badge.

140

261-01948

B3000n, FIPS 140-2 Device License.

140

230-01925

B3000 Series Battery, White.

280

230-02008

B3000, Charger, 8-Bay, NA.

20

230-02001

B3000, Charger, Single-Bay, Universal.

7

230-01995

B3000, Double-Breakaway Lanyard, 25-Pack.

12

230-01985

B3000, Universal Clip, 25-Pack.

12

230-01881

Training Kit, Vocera 4.3, 100 Users.

2

VOCERA-BCONFIG

Vocera Badge Configuration Station (Workstation/Laptop & Wireless Access Point).

1

VOCERA-DMG

Dialogic Media Gateway.

1

Vocera-Server2020

Dell PowerEdge Rack Mounted Server - 6.X Servers.

2

Vocera-Server2020

Analytics Server.

1

SOFTWARE MAINTENANCE & SUPPORT

920-01574

Vocera Premier Support, Enterprise License - Voice, 150 Users.

BASE YEAR PLUS FOUR ONE YEAR OPTIONS.

1

920-02050

Vocera Premier Support, Messaging, 50 users.

BASE YEAR PLUS FOUR ONE YEAR OPTIONS.

1

920-01965

Vocera Platform, Premier Support, Instance.

BASE YEAR PLUS FOUR ONE YEAR OPTIONS.

1

920-04137

Vocera Platform, Premier Support, Virtual Appliance.

ONE YEAR.

1

920-01111

Vocera Premier Support, SIP Telephony, 6 ports.

BASE YEAR PLUS FOUR ONE YEAR OPTIONS.

1

PROFESSIONAL SERVICES & EXTENDED WARRANTY

920-01793

Warranty, B3000 / B3000n, Customer Care, 2-Year extension.

140

Clinical Solutions Consultant

Clinical Solutions Consultant.

400

GENERAL SPECIFICATIONS NEEDED TO BE MET OR EXCEEDED IF AN EQUAL ITEM:

- Shall be a hands-free, voice controlled, wearable and lightweight communication device. This allows for increased mobility and greater practicality and productivity for nurses who often need to complete multiple tasks simultaneously. For example, a clinician in a sterile environment, isolation room, or having full or gloved up hands can still answer a call immediately.

- Device shall be FIPS 140-2 Certified to operate in the VA wireless network.

- Shall enable voice calls to individuals, roles, and teams/groups without having to know who is on shift or what number to call. The solution must be able to maintain an unlimited amount of these groups to eliminate the need to program groups on the fly. This helps keep clinicians at the bedside and saves staff time and frustration associated with keeping up to date on-call schedules and ensures that every call reaches its desired end point.

- All calls shall be capable of automatic escalation to a pre-designed call flow path leading to no calls going unanswered. Customer-defined workflows can be used to escalate calls to other users, groups, internal desk extensions and external numbers whenever the initial recipient is not available. The customer s workflow defines how calls move to the appropriate backup in a timely fashion ensuring patient safety and satisfaction as well as communication efficiency.

- Shall be able to interrupt a busy device upon the request of an urgent call (permission based), i.e. calling a Code Blue.

- Shall be able to initiate a call to a panic group .

- Shall be able to initiate a push to talk session within a department or group that allows all members to speak and hear the call, i.e., please help, my patient has fallen in room 345 .

- The Communication System shall incorporate permission-based controls for placing and receiving calls from a pre-approved list of phone numbers, extensions, and pagers.

- Shall be able to call a pager or any department by name without knowing the extension number, eliminating time, steps, and the need to leave a patient s bedside.

- Shall have the ability to enable off site users to participate in system commands such as, calling by name or job function. For example, a physician, or a pharmacist can call Room 402 Nurse from their landline extension or cell phone.

- To minimize risk of nosocomial infection, the device shall incorporate anti-microbial material to inhibit the growth of bacteria, mold, and fungi.

- Devices shall have a full 3-year warranty to protect and assure the lifetime of the system.

- Shall be able to leave a voice message for a user or group of users that can be retrieved when logging back into the system.

- Communication System shall include a central monitoring capability of user presence, allowing someone to view individual staff availability via a web-based application used by staff coordinators and nurse administrators to quickly and accurately view staff presence information and make staff assignments for dynamic role-based groups. Additionally, shall enable sending secure text messages which can also be sent from the console to users. This streamlines critical communication within the unit, allowing unit coordinators to instantly communicate with staff using either voice or text messaging.

- Solution shall be User Centric , not device centric . Upon log-on, all profiles and privileges should automatically be assigned to the device including roles/functions, group memberships and system settings. All these settings should reside on the server and be independent of the individual device. This enables sharing a device between shifts and easily circulating devices into the hospital environment without a lot of administrative effort or cost. It also ensures identical user experience regardless of the device logged into.

- Shall have advanced analytics to measure system utilization and improvement opportunities.

- Shall have a Device Management reporting mechanism to minimize device loss.

All interested firms who can meet the requirements stated above should respond, in writing,

INCLUDING ALL THE FOLLOWING:

1. Company name.

2. Address.

3. Point of contact (name/title/telephone number/e-mail address).

4. FSS / SEWP Contract number, if applicable.

5. DUNS number.

6. Tax ID number.

7. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small

Business) for which the organization qualifies.

8. A capability statement that addresses the organizations qualifications and ability to provide the

requirement depicted above.

9. Documentation from manufacturer (i.e. correspondence from manufacturer) of your

firm being an authorized distributor for the manufacturer.

Submit responses to the Contracting Officer, Thomas Chesak, at thomas.chesak@va.gov no later

than 11:59 PM (Central Standard Time), 27 JULY 2021. 36C25221Q0976 COMMUNICATION & MESSAGING SYSTEM for Madison MVH shall be referenced on all correspondence regarding this announcement.

TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.

The NAICS Code 334220 (RADIO AND TELEVISION BROADCASTING AND WIRELESS COMMUNICATIONS EQUIPMENT MANUFACTURING), is applicable to this acquisition; the size standard is 1,250 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice: no other copies of this notice will be provided.

Files

File Type Posted
36C25221Q0976.docx DOCX document

Notice history

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors