4410--DA Control Valve and Safety Replacement
Closed Solicitation Posted
- Solicitation number
- 36C24825Q1169
- Agency
-
Veterans Integrated Service Network 8
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- PSC
- 4410 Industrial Boilers
- Place of performance
- Department of Veterans Affairs North Florida/South Georgia VHS Lake City, Florida 32505, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8 is procuring DA Control Valve and Safety Replacement services for the Lake City VA Medical Center in Florida. The solicitation requires a contractor to furnish and install Siemens brand or equivalent deaerator level control and safety valve equipment for the medical center's boiler plant, including NEMA 1 enclosure, water level controller, power transformer, Modbus communication module, main disconnect switch, steam valve with actuator, differential pressure transmitter, BAS gateway, and multiple Kunkle relief valves. Contractors must remove existing components, install new valves and controls, integrate with the existing Building Automation System, and ensure full compliance with VHA Directive 1810. The government will evaluate quotes based on technical capability, past performance, and price, with the intent to make a best value award. Responses to this solicitation are due by September 8, 2025, at 4:00 PM Eastern Time, and quotes must be submitted electronically to the Contracting Officer.
This procurement is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses under NAICS code 333415 and Product Service Code 4410. The solicitation does not identify any current incumbents or specific award values in the available documentation. Delivery of the equipment and completion of installation services is expected within 30 days after receipt of order. The work will be performed at the North Florida/South Georgia VHS Lake City VA Medical Center, located at 619 S. Marion Ave, Lake City, Florida 32505. The contracting office is based in Gainesville, FL, with John H. Shultzaberger serving as the Contracting Officer for this procurement.
Notice text
DA Control and Safety Valves
Files
| File | Type | Posted |
|---|---|---|
| RFQ Attachment.pdf | ||
| 36C24825Q1169_1.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| N048-- B41 Isolation Valve Installation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Valve, regulating, fluid | Land and Maritime | Service-Disabled Veteran-Owned Small Business | |
| N045--Boiler 3 Oxygen Analyzer and Steam Flow Meter | Veterans Integrated Service Network 7 | Service-Disabled Veteran-Owned Small Business | |
| Y1AA--Buy American Act Compliant Valves, 2. 5-inch and larger | Veterans Integrated Service Network 10 | No set-aside | |
| Z2DA--FY27 NRM | 557-23-104 | Replace Boiler Plant Steam Boilers | Construction (VA-27-00003633) | Veterans Integrated Service Network 7 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity