The Department of the Air Force Pacific Air Forces is seeking a small business provider to supply a Cryogenic Vacuum Pump for the 36th Logistics Readiness Squadron at Andersen Air Force Base in Guam. The vacuum pump must meet specific salient characteristics, including the ability to create a vacuum down to 1 micron in a 6,000-gallon liquid oxygen storage tank within 30-60 minutes of operation and include a McLeod Gauge to measure partial pressure. Offers will be evaluated based on acceptability per the salient characteristics and price, with delivery time as a secondary factor. The government intends to award a purchase order without discussions.
This is a 100% small business set-aside acquisition under NAICS code 333912 - Air and Gas Compressor Manufacturing. The North American Industry Classification System (NAICS) code is 333912, and the Product and Service Code (PSC) is 4310-P Compressors And Vacuum Pumps. Offers are due by June 27, 2024, at 11:00 AM Chamorro Standard Time. The government intends to award a purchase order for one vacuum pump unit with direct delivery to Andersen AFB in Guam.
Notice text
2 versions
Update #2 · Latest ·
See attachments for additional details.
6/24/2024: AMENDMENT 0001
The purpose of this amendment is to provide responses to Requests For Information received.
Q1: Can you give any details on the Gauge you wish to be furnished. Most McLeod gauges appear to be laboratory devices. Do you want the gauge to be plugged into the system permanently? We have never furnished a gauge to the USAF with this system before.
A1: The Gauge should not be plugged into the system permanently. The system needs to come with a calibrated gauge that provides readings down to the blank-off or ultimate suction pressure of the vacuum pump at 0.001 Torr or 1 micron Hg. Gauge should be removable for recertification/recalibration.
Update #1 ·
See attachments for additional details.
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Vacuum pump unit | Naval Supply Systems Command | No set-aside | |
| Vacuum pump, aircraf | Naval Supply Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity