187FW - Bldg 1805 MUNS Roof Repair

Closed Solicitation Posted

Solicitation number
W50S6N24Q0010
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
238160 Roofing Contractors
Place of performance
Montgomery, Alabama 36108, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Alabama Army National Guard, through the 187th Fighter Wing, is soliciting proposals for the repair and replacement of the damaged roof, roof insulation, gutters, and lightning protection system on Building 1805 of the Munitions (MUNS) Complex at Dannelly Airfield in Montgomery, Alabama. The work includes removing and disposing of the existing roofing materials, repairing the existing wood blocking, installing new roof insulation and a fully-adhered TPO roofing system, as well as new sheet metal components. The contractor must also provide certification that the new lightning protection system complies with NFPA 780. Quotes are due by August 12, 2024, and the government intends to award a firm-fixed-price contract to the responsible offeror whose quote conforms to the solicitation and is most advantageous, considering past performance and price.

This solicitation is set aside 100% for small businesses. The estimated roof repair area is approximately 1,988 square feet, and the period of performance is 14 calendar days after the notice to proceed is issued. The North American Industry Classification System (NAICS) code for this procurement is 238160 (Roofing Contractors), and the Product Service Code (PSC) is Z2EA-P (Repair Or Alteration Of Ammunition Facilities).

Notice text

3 versions

Update #3 · Latest ·

8 Aug 2024 - AMD 02:  The purpose of this amendment is to provide all prospective offerors with RFI #2 (attached).

17 July 2024 - AMD 01:  The purpose of this amendment is to provide all prospective offerors with RFI #1 (attached).  

The 187th Fighter Wing - Alabama Air National Guard has a requirement for Repair and Replacement to damaged roof, roof insulation, gutters, and lightning protection (remove and re-install existing) on Building 1805 of the Munitions (MUNS) Complex at Dannelly Airfield in Montgomery, Alabama.

Update #2 ·

The purpose of this amendment is to provide all prospective offerors with RFI #1 (attached).  

The 187th Fighter Wing - Alabama Air National Guard has a requirement for Repair and Replacement to damaged roof, roof insulation, gutters, and lightning protection (remove and re-install existing) on Building 1805 of the Munitions (MUNS) Complex at Dannelly Airfield in Montgomery, Alabama.

Update #1 ·

The 187th Fighter Wing - Alabama Air National Guard has a requirement for Repair and Replacement to damaged roof, roof insulation, gutters, and lightning protection (remove and re-install existing) on Building 1805 of the Munitions (MUNS) Complex at Dannelly Airfield in Montgomery, Alabama.

Files

File Type Posted
RFI 2_(W50S6N24Q0010).pdf PDF
RFI 1_(W50S6N24Q0010).pdf PDF
W50S6N24Q0010_Bldg 1805 MUNS Roof Repair.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
WWYK260004 - repair structural integrity, B1134, post 34 & north wall Tinker AFB, Oklahoma 73145, United States · NAICS 238190 Air Force Sustainment Center Total Small Business
NY montezuma NWR main shop roof NAICS 238160 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors