The Air Force Test Center's Installation Contracting Division at Arnold Air Force Base in Tennessee is seeking qualified contractors to conduct Close Interval Potential (CIP) and Direct Current Voltage Gradient (DCVG) surveys on underground electrical and fuel pipeline systems. The government requires contractors to perform comprehensive corrosion assessments in accordance with NACE/AMPP standards, with all work supervised by NACE Certified Corrosion Specialists and Level 2 or higher Cathodic Protection Technician certified personnel. Key contract requirements include performing direct assessments per NACE SP0502 standards, documenting pipe coating conditions, conducting necessary excavations and repairs, and submitting detailed assessment reports with GPS coordinates, root cause analysis, and preventive maintenance recommendations. This pre-solicitation notice does not establish evaluation criteria, as it is a sources sought announcement intended to identify interested and capable contractors before formal solicitation; however, the submission should demonstrate technical capabilities and qualified key personnel meeting the technical requirements. The response deadline for this sources sought notice is May 1, 2026, and interested contractors should note that this announcement is for informational purposes only and does not constitute a binding commitment or solicitation.
No set-aside designations have been applied to this procurement. The survey will encompass approximately 19,938 linear feet of 161 kilovolt oil-filled underground pipeline (System 1) built in the 1950s and 3,500 linear feet of underground fuel pipeline (System 2), with pipes buried between 5 and 13 feet deep and subject to multiple utility crossings. Contractors must address asbestos-containing pipe coatings requiring coordinated disposal and install red fiberglass drivable markers every 200 feet along the cable routes with appropriate warning labels. The notice does not specify a contract value or budget range, nor does it identify any current contractor or incumbent. The anticipated NAICS code is 541330 (Engineering Services) with a Product/Service Code of J059 (Maintenance, Repair, and Rebuilding of Equipment—Electrical and Electronic Equipment Components), indicating this is classified as an engineering services contract for equipment maintenance and repair.
Notice text
SOURCES SOUGHT NOTICE
The Air Force Test Center’s Installation Contracting Division (AFTC/PZI) at Arnold Air Force Base (AFB) located in Tennessee is seeking sources that are interested in and capable of meeting the Government’s requirement to conduct a survey of existing 161 kV cables at Arnold AFB, TN.
CONTRACTING OFFICE ADDRESS:
AFTC/PZI
100 Kindel Drive, Suite A-335 Arnold AFB TN 37389-1335
DISCLAIMER:
THIS SOURCES SOUGHT NOTICE IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT A REQUEST FOR QUOTE. IT DOES NOT CONSTITUTE A SOLICITATION AND SHALL NOT BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT. RESPONSES IN ANY FORM ARE NOT OFFERS AND THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. NO FUNDS ARE AVAILABLE TO PAY FOR PREPARATION OF RESPONSES TO THIS ANNOUNCEMENT. ANY INFORMATION SUBMITTED BY RESPONDENTS TO THIS ANNOUNCEMENT IS STRICTLY VOLUNTARY.
INTRODUCTION:
The Government requires two Close Interval and Direct Voltage Current Gradient surveys to be conducted at Arnold AFB, TN. Scope includes approximately 19,938 linear feet of underground 161kV oil filled pipeline (system 1) and 3,500 linear feet of underground fuel pipeline (system 2). See Attachment 1 – Technical Requirements for additional details.
NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE:
The anticipated North American Industry Classification System Code (NAICS) for this requirement is 541330 Engineering Services. The anticipated Product/Service Code (PSC) is J059 Maintenance, Repair, and Rebuilding of Equipment- Electrical and Electronic Equipment Components.
SUBMISSION DETAILS:
Responses should include:
- Company Information: Company name, company address, and telephone number and e-mail address of company point of contact.
- System for Award Management (SAM) Unique Entity Identifier (UEI) Number.
- Overview of company’s technical capabilities including confirmation of key personnel with qualifications meeting the requirements in Attachment 1.
Submission: Provide your company’s overview of technical capabilities to meet the subject requirement no later than 2:00 PM Central Time (CT) on 28 April 2026, via email to Ms. Haley Smith at haley.smith.10@us.af.mil.
NOTE:If the technical capabilities of your company align with the requirement, the Contracting Officer may contact the company POC to schedule a follow-up discussion with the Government Project Team.