This is a Questions and Answers (Q&A) document that clarifies technical specifications for fiber optic cable and related communication equipment required under FEMA Region 1's solicitation for Fiber Optic Cable & Wires (WX03406Y2026T). The document addresses detailed requirements for a 24-fiber OM4 multimode armored cable with dual LC duplex connectors (UPC termination type, pre-terminated on both ends) that must be gel-filled, armored, and rated for underground/outdoor use. The cable requires a pulling eye with protective sock and must break out into 12 transmit and receive pairs at each end, connected to a standard LC 19-inch rack mountable patch panel, with specified fiber polarity ensuring pair-to-pair matching across termination points. Additionally, the Q&A specifies requirements for an 18/6C shielded communication cable with tinned copper stranded conductors, underground gel material insulation, white jacket color (or alternative options if unavailable), and a 300V voltage rating. The document also references DMP 3012 clip-on tamper switches (normally closed) as required components. These specifications support the delivery of supplies to 63 Old Marlboro Road, Maynard, MA 01754, with a proposal deadline of August 6, 2026 at 4:00 PM ET and a delivery requirement within 90 days of contract award.

View the file

Other files

File Type Posted
2.2.1 RFQ - Fiber Optic Cables & Wires.pdf PDF
SOW - Fiber Optic Cable - Wires.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Question FEMA Response

Delivery Zip Code
01754.
Are LC connectors are required on both ends for the 24-fiber OM4 multimode armored cable?
LC connectors are required on both ends.
Are the required connectors LC simplex or LC duplex?
LC Duplex (must be compatible with standard Cisco SFP).
Is there a required fiber polarity or connector mapping for the 24-fiber cable?
Pair 1 TX/RX Pair 2 TX/RX etc… pair 1 should match to pair 1 on the opposite end pair 2 to pair 2 etc…
Does it need to be gel-filled?
Yes. Should be gel filled, armored, and underground/outdoor rated.
Is a pulling eye, protective pulling sock, or other pulling protection required for the pre-terminated fiber cable?
Yes, this should have a pulling eye with a protective sock.
is a required breakout or fan-out length at each terminated end?
Yes they must break out to the 12 transmit and receive pairs as answered in question 3 to standard LC 19-inch rack mountable patch panel.
Reference for the clip-on tamper switches
Reference DMP 3012 Clip On Tamper (normally closed).
What is LC the connector type for the 24-fiber OM4 Fiber Optic Cable?
UPC
Termination type
Dual-end pre-terminated
For the 18/6C Shielded Communication Cable, what is the Conductor Material?
Tinned Copper
Conductor Structure?
Stranded
Specific requirements for the insulation & Jacket material?
Color preferred to be white (if unable to provide white, please provide choices), Insulation = underground gel material
Voltage rating
300v