1. Vendor will purchase and install the following items to an existing Tower Trailer at MERS Frederick:

a. Wilburt 10.8-76 Pneumatic Mast with all associated parts and pieces between current shelter and generator

i. ¾ HP AC air compressor

ii. 3 gallon air tank

iii. Electric up/down solenoids

iv. Emergency dump valve

v. Associated “Mast Guy Kit”

vi. Foot pedal control at the base of the mast

1. Cord must be long enough to reach the top of the shelter in case of 1-person operation

vii. All associated switches and plumbing

viii. Pneumatic oiler

ix. 125’ nycoil with the following:

1. 4 LMR 400

2. 2 CAT 6

3. 2 16 gauge wires

4. 2 4 conductor/18 gauge 9418 wires

5. Cables must be terminated to a junction box at the top and have 20’ of slack at the bottom

a. Final length will be determined once specific design is determined

6. All connectors on the mast will use mil-spec weatherproof connectors

b. All fabrication work to install Wilburt 10.8-76 mast onto existing FEMA Trailer to include:

i. Support basket

ii. Cutting of current deck plating

iii. All support frames

iv. Must ensure current support frame under trailer is incorporated into new basket/mount

v. Aircraft light at top of mast

All work must be done by a “certified Wilburt Mast Installer” and due to deployment possibilities of platforms, all work must be completed at a vendor location within 75 miles of Frederick, MD.