DESIGNED
CHIEF, ENGINEERING DIVISION
DATE
APPROVED
RECOMMENDED
BRANCH CHIEF
SUBMITTED
PROJECT MANAGER
CHECKED
DRAWN BY
NO. DATE
DRAWING NUMBER
SCALE
SHEET OF
SHEET
DESCRIPTION
REVISIONS
APPROVEDBY
SHEET SIZE
ANSI D
DRAWING TITLE
WHITE SANDS MISSILE RANGE, NEW MEXICO
DIRECTORATE OF PUBLIC WORKS
ENGINEERING SERVICES DIVISION
CESAR LIMON
C.LIMON
RAFAEL H. ACOSTA
BUILDING 19467 OVERHEAD CRANE HOIST UPGRADE
WS-19467-2021-G-G1-01
COVER SHEET
BUILDING 19467
1 04
W H
I T E
S ANDS MIS S I LE
RA
N
G E
B I RTHPLACE
OF
AMERI CA' S MI SSI LE & SPACE
AC
TI
V
IT
Y
LUCIANO RIGALES
CONCURRENCES
Note: Signatures affixed on this sheet indicate official recommendation and approval of all the drawings in this set as indexed on this sheet
Safety
Security
Department
Environmental
Force Protection
Management
Maintenance
Customer 1
Customer 2
DPW
Information
Anti-Terrorism
Fire
Physical
Garrison
Operations &
03/10/21
AutoCAD SHX Text
WHITE SANDS MISSILE RANGE, NEW MEXICO
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS
AutoCAD SHX Text
ENGINEERING DIVISION
AutoCAD SHX Text
BID SET 100%%% DESIGN
AutoCAD SHX Text
ISSUED FOR CONSTRCUTION
SHEET INDEX
DRAWING NUMBER TITLE
WS-19467-2021-G-G1-01 BUILDING 19467 COVER SHEET
WS-19467-2021-G-G1-02 BUILDING 19467 INDEX SHEET/LOCATION MAP
WS-19467-2021-W-FP-03 BUILDING 19467 CRANE LAYOUT
WS-19467-2021-E-04 BUILDING 19467 ELECTRICAL LAYOUT FOR CRANE
DESIGNED
CHIEF, ENGINEERING DIVISION
DATE
APPROVED
RECOMMENDED
BRANCH CHIEF
SUBMITTED
PROJECT MANAGER
CHECKED
DRAWN BY
NO. DATE
DRAWING NUMBER
SCALE
SHEET OF
SHEET
DESCRIPTION
REVISIONS
APPROVEDBY
SHEET SIZE
ANSI D
DRAWING TITLE
WHITE SANDS MISSILE RANGE, NEW MEXICO
DIRECTORATE OF PUBLIC WORKS
ENGINEERING SERVICES DIVISION
CESAR LIMON
C.LIMON
RAFAEL H. ACOSTA
WS-19467-2021-G-G1-02
INDEX SHEET/LOCATION MAP
BUILDING 19467
2 04
PROJECT LOCATION BUILDING 19467
LAS CRUCES GATE
LUCIANO RIGALES
03/10/21
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
BID SET 100%%% DESIGN
' 6
6'
" 2'
' 0
44' 0"
C L
12"
ROOF
SCALE: 14" = 1' 0"
SECTION
SCALE: 3/8" = 1' 0"
EXISTING LONG
WALL SHOWN
DOTTED
EXISTING FLOOR
EXISTING WALL
METAL WALL BETWEEN
RAILS
12' X 10' SWING
DOOR W/HV
EXISTING LONG WALL
SHOWN DOTTED
EXISTING BRIDGE CRANE
DESIGNED
CHIEF, ENGINEERING DIVISION
DATE
APPROVED
RECOMMENDED
BRANCH CHIEF
SUBMITTED
PROJECT MANAGER
CHECKED
DRAWN BY
NO. DATE
DRAWING NUMBER
SCALE
SHEET OF
SHEET
DESCRIPTION
REVISIONS
APPROVEDBY
SHEET SIZE
WHITE SANDS MISSILE RANGE, NEW MEXICO
DIRECTORATE OF PUBLIC WORKS
ENGINEERING SERVICES DIVISION
DRAWING TITLE
ANSI D
CESAR M. LIMON
C.LIMON
LUCIANO RIGALES
RAFAEL ACOSTA
3 04
KEY NOTES:
WS-19467A-2021-FP-03
CONTRACTOR SHALL REMOVE THE TWO EXISTING
CRANE HOIST AND INSTALL ONE NEW 5 TON
CAPACITY CRANE HOIST, 3 PHASE, 460 V, AND TWO
SPEED HOIST ON EXISTING CRANE RAIL SYSTEM
WITH A HANDHELD CONTROL BOX AND INCLUDE
REPLACING MOTORS, CHAINS, AND GEARS USED TO
MOVE BEAM ON RAILS. GOVERNMENT SHALL
SALVAGE EXISTING CRANE HOIST ONCE THEY ARE
REMOVED. CONTRACTOR SHALL INSTALL NEW
HORIZONTAL STOPS, PAINT AS LISTED IN
MIL-HDBK-1038 SECTION 4.3.6.41, AND RE-LABEL
EXISTING BEAM AND RAILS. THE CONTRACTOR
SHALL CONDUCT THE NECESSARY SYSTEM LOAD
TEST TO CERTIFY THE NEW CRANE HOIST AND
PROVIDE A COPY OF THE TEST RESULTS WITH THE
CERTIFICATION TO THE COR. NEW CRANE HOIST
SHALL MATCH EXISTING CLEARANCES.
BUILDING 19467
CRANE LAYOUT
1. THIS PROJECT IS TO BE DONE IN BUILDING 19467. IT IS
THE CONTRACTORS RESPONSIBILITY TO PERFORM
ABATEMENT AS SPECIFIED IN THE STATEMENT OF
WORK.
2. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAR
OF ANY CONSTRUCTION DEBRIS AT ALL TIMES AND TO
PUT A TEMPORARY FENCE DIMENSIONS 6 FT H X 15 FT
W X 20 FT L TO KEEP NON CONSTRUCTION PERSONAL
FROM GOING INTO BUILDING 19467 WHILE
CONSTRUCTION IS ON GOING. ALL DEBRIS GENERATED
BY THIS PROJECT SHALL BE PROPERLY DISPOSED OF
OFF POST.
3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE
WITH ALL APPLICABLE FEDERAL, STATE, AND
LOCAL REQUIREMENTS.
4. THE OVERHEAD CRANE HOIST SHALL BE
MANUFACTURED AND INSTALLED TO THE EXISTING
OVERHEAD CRANE RAILS FOR A FACILITY
THAT HANDLES EXPLOSIVES. THE HOOK FOR THE
HOIST SHALL BE FABRICATED OF CORROSION
RESISTANT STEEL FOR USE IN HAZARDOUS
ENVIRONMENTS (EXPLOSIVES) LISTED IN THE
UFC 3-320-07N MIL-HDBK-1038 SECTION 4.3.6.19 HOOKS.
CONTRACTOR SHALL SUBMIT SET OF SHOP DRAWINGS
WITH THE STAMP OF A REGISTERED ENGINEER OF ANY
STATE IN THE US WITH A CURRENT LICENSE AS LISTED
IN MIL-HDBK-1038 SECTION 7.1.1 DESIGN
RESPONSIBILITY. CONTRACTOR SHALL CONSIDER THE
STRUCTURAL DESIGN LOADS THAT INCLUDE THE DEAD
LOAD AND RATED LOAD AS LISTED IN MIL-HDBK-1038
SECTION 5.1.1 STRUCTURAL DESIGN LOAD, 5.1.1.1 DEAD
LOAD, AND 5.1.1.2 RATED LOAD.
5. CONTRACTOR SHALL PROVIDE THE GOVERNMENT THE
CERTIFICATES LISTED IN MIL-HDBK-1038
SECTION CERTIFICATES 7.6 a, b, c, d, e, f, g, i and l WHEN
THE CONSTRUCTION IS FINISHED AND NEW CRANE
HOIST IS OPERATIONAL.
6. BUILDING 19467 PERSONAL MR. TOM ESTES OR MR
MIGUEL TORRES SHALL NOTIFY COR A WEEK IN
ADVANCE TO INFORM THE CONTRACTOR IF THEY WILL
BE DELAYED TO NOT COME A DAY OF THE WEEK DUE
TO THE FORECASTED TESTING SCHEDULE OR
SECURITY REASONS.
7. CONTRACTOR SHALL COMPLY AND FOLLOW THE FIRE
PREVENTION GUIDE FOR CIVILIAN CONTRACTORS
WITH THE HOT WORK PERMIT FOR ANY WELDING
DURING THE CONSTRUCTION AT WSMR LISTED IN
SOW SECTION 3.12 HOT WORK PERMITS ALONG WITH
THE EMERGENCY REPORTING PROCEDURES. ENSURE
THAT PROPER FIRE EXTINGUISHERS OR FIRE
BLANKETS ARE ON HAND WHEN PERFORMING HOT
WORK OPERATIONS. ALL EQUIPMENT BEING USED
FOR HOT WORK OPERATIONS MUST BE IN PROPER
OPERATING CONDITION AND POSE NO POTENTIAL FOR
FIRE OR HAZARDS. CALL (575) 678-1234 FOR ANY
EMERGENCIES AND REPORT ANY ACCIDENTAL FIRES.
GENERAL NOTES
NOTES:
THE EAST AND WEST CRANE HOIST MANUFACTURE AND
CAPACITY INFORMATION BELOW.
1) HOIST MANUFACTURE: N/A
S/N: 7Q760
HOIST CAPACITY: 1-TON
CRANE CAPACITY: 2-TON
TYPE: MONORAIL
VOLTAGE: 208V/3/60 HZ
2) CRANE MANUFACTURE: CHECO
HOIST MANUFACTURE: DETROIT
S/N: 24386E
HOIST CAPACITY: 4-TON
CRANE CAPACITY: 8-TON
TYPE: SGTRUH
VOLTAGE: 460 V/3/60 HZ
03/10/21
AutoCAD SHX Text N
AutoCAD SHX Text
BID SET 100%%% DESIGN
ELECTRICAL LEGEND
DISTRIBUTION PANEL
SAFETY FUSE DISCONNECT SWITCH
DESIGNED
CHIEF, ENGINEERING DIVISION
DATE
APPROVED
RECOMMENDED
BRANCH CHIEF
SUBMITTED
PROJECT MANAGER
CHECKED
DRAWN BY
NO. DATE
DRAWING NUMBER
SCALE
SHEET OF
SHEET
DESCRIPTION
REVISIONS
APPROVEDBY
SHEET SIZE
NTS
WHITE SANDS MISSILE RANGE, NEW MEXICO
DIRECTORATE OF PUBLIC WORKS
ENGINEERING SERVICES DIVISION
DRAWING TITLE
WS-19467-2020-E-04
03/10/21 ANSI D
CESAR M. LIMON
C.LIMON
LUCIANO RIGALES
RAFAEL ACOSTA
4 04
KEY NOTES:
3BAY 4
BLDG 19467
BUILDING 19467
ELECTRICAL LAYOUT FOR
CRANE
PANEL D-3 PHASE, 208 / 120 V, THE WEST CRANE
CIRCUIT BREAKER #8-60 AMP, 3 POLE, WHERE THE
EXISTING WIRE SHALL BE REMOVED. CIRCUIT
BREAKER #8 SHALL REMAIN IN THE PANEL ON
"OFF" POSITION.
PANEL A-3 PHASE, 480 / 277 V, THE EAST CRANE
CIRCUIT BREAKER #18-60 AMP (GOVERNMENT
SHALL SALVAGE CIRCUIT BREAKER ) , 3 POLE,
SHALL BE REPLACED WITH A 150 AMP (SIZED
ACCORDING TO NEC 2020 610.42 (A), NEMA 7), 3
POLE BREAKER, AND MOLDED CASE
TO POWER A 460 V, 3 PHASE, 40 HP INDUCTION
MOTOR, AND CONTRACTOR SHALL REMOVE 125
FEET LONG OF BOTH EXISTING WIRE AND CONDUIT
AND RUN BOTH 90 FEET OF NEW CONDUCTORS
# 1 / 0 AWG (#6 AWG EQUIPMENT GROUND WIRE) ,
THHN, COPPER STRANDED, 600 V RATED AND 2"
RIGID CONDUIT.
REMOVE AND INSTALL 1 WALL MOUNTED HEAVY
DUTY FUSE EXPLOSION PROOF DISCONNECT
SWITCH NEMA 4, 7, AND 9, 200 AMP, 600 VOLT, 3
POLE, WITH 3-150 AMP DUAL ELEMENT TIME DELAY
FUSES (3 TOTAL).
AMPLIFIER
ROOM
NOTES:
ALL ELECTRICAL AND MECHANICAL INSTALLATION SHALL COMPLY IN
ACCORDANCE WITH THE NEC 2020 ARTICLE 250, 500, 610, 610-III, 610-VI,
430.112 EX, 610-IV, 668.32, 400.10(A)(5), 250.22(1), 250.112(E), 250.116(1),
610-VII, 503.155, 610.3A, 430.112 EX, 610.14(G), 610-V, 610.53, 610-II, AND
UFC 3-320-07NMIL-HDBK-1038 SECTION 6.3 HAZARDOUS (EXPLOSIVE)
ENVIRONMENT, AND SECTION 6.5 ORDANANCE/EXPLOSIVE HANDLING
AND NFPA 70 (CMAA 70) SERVICE CLASSIFICATION CLASS D
(HEAVY-DUTY) FOR HANDLING ORDNANCE/EXPLOSIVES. ALL NEW
CONDUIT SHALL BE RIGID CONDUIT SHALL BE SURFACE MOUNTED OR
INSIDE WALLS, ABOVE CEILING. CONCEAL MOST OF THE CONDUIT
ABOVE AND BELOW CEILINGS WHEREVER POSSIBLE AND TIGHTEN ALL
CONDUIT SECURE. EXPOSURE OF CONDUIT IS ALLOWED IN AREAS
WHERE IS OPEN CEILING OR CMU WALLS. SEAL ALL PENETRATIONS
AND IF NECESSARY APPLY PAINT AS NEEDED WHERE AREAS ARE
SCRATCHED ON THE WALL RESULTING FROM THE WORK THAT IS BEING
PERFORMED. ALL NEW CONDUCTORS SHALL BE 600 VOLT, THHN, AND
COPPER STRANDED FOR ALL THE CIRCUITS TO INCLUDE GROUNDS.
CONDUIT SHALL BE SURFACE MOUNTED OR INSIDE WALLS, ABOVE
CEILING.
AutoCAD SHX Text N
AutoCAD SHX Text
BID SET 100%%% DESIGN
| Sheets and Views |
| WTD036470P- PLANS AND DRAWINGS - 08 JANUAURAY 2021 -100% Design Review Upgrade Overhead Crane for Building 19467-BUILDING ELEVATION (2) |
| WTD036470P- PLANS AND DRAWINGS - 08 JANUAURAY 2021 -100% Design Review Upgrade Overhead Crane for Building 19467-BUILDING ELEVATION (3) |