Proposed Renovation for Wexford-Missaukee ISD Special Services Building
This is a construction document package for a proposed renovation project in Cadillac, Michigan, under the jurisdiction of the State of Michigan, Bureau of Construction Codes (BCC), and Bureau of Fire Services (BFS), governed by the 2021 Michigan Building Code (MBC), 2021 Michigan Rehabilitation Code for Existing Buildings (MRC), 2021 Michigan Plumbing Code (MPC), 2021 Michigan Mechanical Code (MMC), 2023 Michigan Electric/National Electrical Code (MEC), and 2017 ANSI A117.1 Accessibility Code. The project involves re-classifying the existing Business Office in the East Wing to Classrooms (Educational Use) in Building #1 (16,577 square feet) and related improvements to Building #2 (12,617 square feet) at 9907 E. 13th Street. The renovation includes creating four new classrooms, three sensory rooms, two new bathroom facilities, a nursing room, and common areas, separated from existing business spaces by a two-hour fire separation wall. The project entails comprehensive demolition of selected existing walls and systems, installation of new gypsum drywall partitions with fire ratings, new door and window systems, plumbing and mechanical modifications, electrical upgrades including emergency lighting, and finish work including painting, flooring (carpet tile and luxury vinyl plank), and hardware installation. The design documents were issued for bidding and construction on April 23, 2026.
The project specifications detail extensive requirements across multiple disciplines including site work, concrete, metals, wood and plastics, thermal and moisture protection, doors and windows, finishes, and specialties. Fire-rated assemblies must comply with NFPA standards and be tested according to UL listings. All interior finishes must meet Michigan Building Code requirements for the new educational classification, including specific fire-resistance ratings for walls (1-hour and 2-hour ratings as applicable), door assemblies with appropriate fire ratings and opening protections, and automatic sprinkler systems where required. The scope includes compliance with ADA/ANSI A117.1 accessibility standards throughout, with detailed specifications for accessible fixtures, grab bars, clearances, and signage. Mechanical systems, plumbing fixtures, electrical distribution, and HVAC modifications are specified to support the new educational use classification. Contractor responsibilities include site verification of existing conditions, coordination of utility disconnections and reconnections, procurement of permits, and provision of as-built documentation at substantial completion. The specifications emphasize single-source responsibility for hardware and equipment systems, quality assurance through manufacturer certifications and testing, and comprehensive warranty provisions including five-year warranties on doors and frames, ten-year warranties on insulating glass units, and one-year warranties on installation workmanship.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| WMISD-SS_Book Spec 4-23-26.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Code Study Actual Area: Ex. Building #1 - 16,577 s.f. inside face of exterior wall.
Ex. Building #2 - 12,617 s.f. inside face of exterior wall.
MBC 202, Definitions.
Allowable Height : E Educational governs: 1 Stories, 40' (MBC Tables 504.3 & 504.4).
Actual Height: Existing, 1 Story, +/- 21'-0" grade to roof peak.
CH. 6: TYPES OF CONSTRUCTION:
Fire Resistance Rating (Elements): 0, Type VB (MBC Table 601).
Construction Type: V-B (Section 602.5). V-000 (NFPA 220) Wd. Roof Deck.
CH. 7: FIRE & SMOKE PROTECTION FEATURES:
Ex. Fire Resistance Rating (Ext. Walls):Ex. 0 hour, > 10' & < 30', Type IIB (Table 705.5).
Fire Separation, ratings: Corridors - 1 hour, MBC 708.3, MBC Table 1020.2, NFPA 101 8.3.4.
Opening Protection, doors: 20 minute in 1 hour rated walls (classroom to corridor).
45 minute in 1 hour rated walls (other rooms).
90 minute in 2 hour rated walls (educational to business).
MBC Table 716.1(2).
Duct Openings, fire dampers: 1 and 2 hour, see Mechanical Plans.
Draft stoppingAttics: Existing, all under 3,000 s.f.
CH. 8: INTERIOR FINISHES:
Interior Finishes: From MBC Table 803.13:
Exit enclosures & passageways: Class B permitted.
Corridors: Class B permitted.
Rooms & Enclosed Spaces: Class C permitted.
Floor Finish: Class II Materials Permitted, MBC 804.4.1 & 804.4.2.
CH. 9: FIRE PROTECTION SYSTEMS:
Automatic Sprinkler Systems: Not Required, MBC 903.2.3, NFPA 14.3.5.1. Less than
12,000 s.f. and less than 300 people.
Portable Fire Extinguishers: Existing to remain.
Manual Fire Alarms: A manual fire fire alarm system is required throughtout the renovation area. F.A. contractor shall be cerytified in the State of Michigan per Michigan Act 144 and submit shop drawings to LARA - BFS for approval (MBC 907.2.3. & NFPA 101 9.6 & 14.3.4). Tie into existing system.
Smoke Alarms: Existing to be upgraded, See Electrical.
CH. 10: MEANS OF EGRESS:
Occupant Load (for Egress Only, Table 1004.1.1): 201 Occupants
Business Area - 75 occupants Office/ Conf - 5180/150 = 34.5 Conference - 553/15 = 36.9 Stor./ Mech. - 1,077/300 = 3.6 Corr./ Restrooms = 0
Proposed Renovation for:
Wexford-Missaukee ISD Special Services Building
9907 E. 13th Street Cadillac, MI 49601
Jurisdiction: State of Michigan, BCC (Bureau of Construction Codes & BFS (Bureau of Fire Services)
Code Enforced: 2021 Michigan Building Code (MBC) 2021 Michigan Rehabilitation Code for Existing Buildings
(MRC)
2021 Michigan Plumbing Code (MPC) 2021 Michigan Mechanical Code (MMC) 2023 Michigan Electric/ National Electrical Code (MEC) 2017 ANSI A117.1 - Michigan Accessibilty Code 2012 NFPA Life Safety 101 w/ 1-28-2016 Amendments
Project Description:
The project consists of re-classifying (Change of Use) of the existing Business Office, Business Use, East Wing, to Classrooms, Educational Use. The new educational use will be separated from the remainder with a two (2) hour fire separation. Each new Classroom will have an egress window or door as indicated.
Note: No separation required in Building #2 by Michigan Building Code, Non-sepatared mixed use.
CH. 5: GENERAL BUILDING HEIGHTS & AREAS:
Use Group Classification:Ex. Mixed B and E, Business (MBC 304) and Educational
(MBC 305).
Allowable Area: Ex. E Educational governs: 15,750 sf/ floor (MBC Table 506.2), with open perimeter increases (MBC Table 506.3.3) each existing building.
CH. 10: MEANS OF EGRESS CON'T.:
Educational Area - 126 occupants
Classrooms - 2,323/20 = 116.2 Sensory Rm. - 3 rms (2 per rm) = 6 Offices/ Nurse - 523/150 = 3.5 Stor./ Data - 85/300 = 0.29 Corr./ Restrooms = 0
Means of Egress illumination required with a minimum of 90 minutes emergency power
(MBC 1008, NFPA 101 7.8 & 14.2.8).
Emergency lighting must have an initial illumnination of at least an average of one (1) footcandle and a minimum of 0.1 footcandle measured along the path of egress at floor level (MBC 1008.3.5, NFPA 101 7.8.1.3 & 14.2.8).
T
ARCHITECTURE
CONSTRUCTION MANAGEMENT
DEVELOPMENT
1104 S. MITCHELL ST.
CADILLAC, MICHIGAN 49601
(231) 779-4002
(231) 779-4022 FAX
ARCHITECT OF RECORD:
DRAWN BY:
PROJECT NUMBER:
SHEET NUMBER:
DATE ISSUED:
THE
DESIGN GROUP
D. DeKryger
K. Taylor
April 23, 2026 Bidding & Construction
25123B
Pr op os ed
R en ov at io n fo r:
W ex fo rd
-M is sa uk ee
IS
D Sp ec ia l S er vi ce s Bu ild in g
E
. 1 3t h St re et
Ca di lla c, M I 4
AutoCAD SHX Text
SITE LOCATION
AutoCAD SHX Text
INDEX OF DRAWINGS
AutoCAD SHX Text
PAGE
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text T
AutoCAD SHX Text
CODE DATA, LOCATION MAP & SHEET INDEX
AutoCAD SHX Text C1.0
AutoCAD SHX Text
DEMOLITION & NEW WORK SITE PLANS
AutoCAD SHX Text
LS0.0
AutoCAD SHX Text
EXISTING LIFE SAFETY
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
LOCATION MAP
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
LS1.0
AutoCAD SHX Text
NEW LIFE SAFETY
AutoCAD SHX Text D1.0
AutoCAD SHX Text
DEMOLITION PLAN, EXTERIOR ELEVATIONS & SECTIONS
AutoCAD SHX Text A1.0
AutoCAD SHX Text
NEW WORK PLAN & SCHEDULES
AutoCAD SHX Text A1.1
AutoCAD SHX Text
NEW WORK R. CEILING PLAN, EXTERIOR ELEVATIONS & SECTIONS
AutoCAD SHX Text A2.0
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.2
AutoCAD SHX Text A2.3
AutoCAD SHX Text A2.4
AutoCAD SHX Text A2.5
AutoCAD SHX Text A2.6
AutoCAD SHX Text A2.7
AutoCAD SHX Text A2.8
AutoCAD SHX Text A2.9
AutoCAD SHX Text A1.2
AutoCAD SHX Text
INTERIOR ELEVATION & ADA / ANSI CLEARANCES
AutoCAD SHX Text
INDEX OF DRAWINGS
AutoCAD SHX Text
PAGE
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
PD1.0
AutoCAD SHX Text
PLUMBING DEMOLITION PLAN
AutoCAD SHX Text P1.0
AutoCAD SHX Text
PLUMBING NEW WORK PLAN - BASE BID
AutoCAD SHX Text
MD1.0
AutoCAD SHX Text
MECHANICAL DEMOLITION PLAN
AutoCAD SHX Text M1.0
AutoCAD SHX Text M1.1
AutoCAD SHX Text E0.0
AutoCAD SHX Text
ELECTRICAL LEGENDS & DETAILS
AutoCAD SHX Text
MECHANICAL NEW WORK PLAN
AutoCAD SHX Text
MECHANICAL PIPING PLAN
AutoCAD SHX Text
ED1.0
AutoCAD SHX Text
ELECTRICAL DEMOLITION PLAN & PANEL SCHEDULES
AutoCAD SHX Text E1.0L
AutoCAD SHX Text
ELECTRICAL NEW WORK LIGHTING PLAN
AutoCAD SHX Text E1.0P
AutoCAD SHX Text
ELECTRICAL NEW WORK POWER PLAN
AutoCAD SHX Text E2.0
AutoCAD SHX Text
ELECTRICAL RISER DIAGRAM
AutoCAD SHX Text
ELC1
AutoCAD SHX Text
EMERGENCY LIGHTING CALCULATION PLAN
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text
ARCHITECTURAL SPECIFICATIONS
AutoCAD SHX Text P1.1
AutoCAD SHX Text
PLUMBING NEW WORK PLAN - ALTERNATE #1
AutoCAD SHX Text P2.0
AutoCAD SHX Text
PLUMBING SCHEDULES & SPECIFICATIONS
AutoCAD SHX Text M1.2
AutoCAD SHX Text
MECHANICAL VENTILATION CALCULATIONS
AutoCAD SHX Text M2.0
AutoCAD SHX Text
MECHANICAL SCHEDULES & SPECIFICATIONS
EB
V
1326.90
GS
1326.70
GS
EB
1326.90
GS
1326.70
GS
EB
1326.90
GS
1326.70
GS
C1.0
ARCHITECTURE
CONSTRUCTION MANAGEMENT
DEVELOPMENT
1104 S. MITCHELL ST.
CADILLAC, MICHIGAN 49601
(231) 779-4002
(231) 779-4022 FAX
ARCHITECT OF RECORD:
DRAWN BY:
PROJECT NUMBER:
SHEET NUMBER:
DATE ISSUED:
THE
DESIGN GROUP
D. DeKryger
K. Taylor
April 23, 2026 Bidding & Construction
25123B
Pr op os ed
R en ov at io n fo r:
W ex fo rd
-M is sa uk ee
IS
D Sp ec ia l S er vi ce s Bu ild in g
E
. 1 3t h St re et
Ca di lla c, M I 4
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
ST
AutoCAD SHX Text
%%UEX. FIN. FLOOR
AutoCAD SHX Text %%o1326.74
AutoCAD SHX Text
%%UEX. FIN. FLOOR
AutoCAD SHX Text %%o1326.74
AutoCAD SHX Text
SAWCUT & REMOVE EXISTING CONC. AS REQ'D TO COMPLETE NEW WORK
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
SITE DEMOLITION PLAN
AutoCAD SHX Text
SCALE 1/16" = 1'-0"
AutoCAD SHX Text
%%UEX. CONC.
AutoCAD SHX Text %%o1326.63
AutoCAD SHX Text
%%UEX. CONC.
AutoCAD SHX Text %%o1327.29
AutoCAD SHX Text
%%UEX. CONC.
AutoCAD SHX Text %%o1328.38
AutoCAD SHX Text
%%UEX. CONC.
AutoCAD SHX Text %%o1327.24
AutoCAD SHX Text
%%UEX. CONC./BIT.
AutoCAD SHX Text %%o1328.42
AutoCAD SHX Text
%%UEX. CB
AutoCAD SHX Text %%o1326.33
AutoCAD SHX Text
%%UEX. CB
AutoCAD SHX Text %%o1326.27
AutoCAD SHX Text
%%UEX. CONC.
AutoCAD SHX Text %%o1326.45
AutoCAD SHX Text
REMOVE EXISTING LAWN / GRADE AS REQ'D TO INSTALL NEW CONC. PAD @ NEW DOOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
ST
AutoCAD SHX Text NEW 4" CONC. PAD w/ 6x6 W1.4/1.4 WWF ON COMPACTED GRANULAR MAT'L. TIE FLUSH INTO EXISTING CONC. w/ 18" LONG #4 DOWELS DRILLED & EPOXIED INTO EXISTING SLAB @ 12" O.C.
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
SITE NEW WORK PLAN
AutoCAD SHX Text
SCALE 1/8" = 1'-0"
AutoCAD SHX Text
%%UEX. FIN. FLOOR
AutoCAD SHX Text %%o1326.74
AutoCAD SHX Text
%%UEX. FIN. FLOOR
AutoCAD SHX Text %%o1326.74
AutoCAD SHX Text
%%UEX. / NEW CONC.
AutoCAD SHX Text %%o1326.63
AutoCAD SHX Text
%%UEX. / NEW CONC.
AutoCAD SHX Text %%o1327.29
AutoCAD SHX Text
%%UEX. CONC.
AutoCAD SHX Text %%o1328.38
AutoCAD SHX Text
%%UEX. / NEW CONC.
AutoCAD SHX Text %%o1327.24
AutoCAD SHX Text
%%UEX. CONC./BIT.
AutoCAD SHX Text %%o1328.42
AutoCAD SHX Text
%%UEX. CB
AutoCAD SHX Text %%o1326.33
AutoCAD SHX Text
%%UEX. CB
AutoCAD SHX Text %%o1326.27
AutoCAD SHX Text
%%UEX. / NEW CONC.
AutoCAD SHX Text %%o1326.45
AutoCAD SHX Text ;8'-0"
AutoCAD SHX Text ;12'-8"
AutoCAD SHX Text
%%UNEW CONC.
AutoCAD SHX Text %%o1326.73
AutoCAD SHX Text
%%UNEW CONC.
AutoCAD SHX Text %%o1326.73
AutoCAD SHX Text
%%UNEW CONC.
AutoCAD SHX Text %%o1326.63
AutoCAD SHX Text
%%UNEW CONC.
AutoCAD SHX Text %%o1326.66
AutoCAD SHX Text 6'-0"
AutoCAD SHX Text ;11'-0"
AutoCAD SHX Text ;13'-5"
AutoCAD SHX Text ;6'-10"
;21'-9"
EXIT
E X
IT
E X
IT
E X
IT
E X
IT
EX
IT
EX
IT
E X
IT
E X
IT
E X
IT
E X
IT
E X
IT
EXIT
E X
IT
EXIT
E X
IT
LS0.0
ARCHITECTURE
CONSTRUCTION MANAGEMENT
DEVELOPMENT
1104 S. MITCHELL ST.
CADILLAC, MICHIGAN 49601
(231) 779-4002
(231) 779-4022 FAX
ARCHITECT OF RECORD:
DRAWN BY:
PROJECT NUMBER:
SHEET NUMBER:
DATE ISSUED:
THE
DESIGN GROUP
D. DeKryger
K. Taylor
April 23, 2026 Bidding & Construction
25123B
Pr op os ed
R en ov at io n fo r:
W ex fo rd
-M is sa uk ee
IS
D Sp ec ia l S er vi ce s Bu ild in g
E
. 1 3t h St re et
Ca di lla c, M I 4
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
EXISTING COMPOSITE FLOOR PLAN
AutoCAD SHX Text
SCALE 3/32" = 1'-0"
AutoCAD SHX Text
%%UPLAN LEGEND:
AutoCAD SHX Text
EXISTING 1 HOUR SEPARATION
AutoCAD SHX Text
EXISTING 2 HR FIRE WALL
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
VEST.
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OPEN OFF.
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
JAN.
AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text
NOTE: HATCH INDICATES AREA OF WORK
AutoCAD SHX Text
VEST.
AutoCAD SHX Text
STOR.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
BOARD ROOM
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
RECORDS
AutoCAD SHX Text
DATA
AutoCAD SHX Text
WORK
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text %%UBUILDING #1 AREA = 16,577 s.f.
AutoCAD SHX Text %%UBUILDING #2 AREA = 12,617 s.f.
AutoCAD SHX Text
FOLLOW 2 HR. FIRE WALL - CONSTRUCTION, ;MARCH 2002
AutoCAD SHX Text
FOLLOW 2 HR. FIRE WALL - CONSTRUCTION, ;1997, MAR. 2002
AutoCAD SHX Text
EXIST'G 2 HR FIRE WALL
AutoCAD SHX Text
EXIST'G 2 HR FIRE WALL
AutoCAD SHX Text
EX. 2 HR FIRE WALL
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 1 HOUR WALL
AutoCAD SHX Text
EX. 1 HR. WALL
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 2 HR.
AutoCAD SHX Text
EX. 2 HR.
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
EX. 2 HR FIRE WALL
EXIT
E X
IT
E X
IT
E X
IT
E X
IT
EX
IT
EX
IT
E X
IT
E X
IT
E X
IT
E X
IT
E X
IT
EXIT
E X
IT
EXIT
E X
IT
EXIT
LS1.0
ARCHITECTURE
CONSTRUCTION MANAGEMENT
DEVELOPMENT
1104 S. MITCHELL ST.
CADILLAC, MICHIGAN 49601
(231) 779-4002
(231) 779-4022 FAX
ARCHITECT OF RECORD:
DRAWN BY:
PROJECT NUMBER:
SHEET NUMBER:
DATE ISSUED:
THE
DESIGN GROUP
D. DeKryger
K. Taylor
April 23, 2026 Bidding & Construction
25123B
Pr op os ed
R en ov at io n fo r:
W ex fo rd
-M is sa uk ee
IS
D Sp ec ia l S er vi ce s Bu ild in g
E
. 1 3t h St re et
Ca di lla c, M I 4
AutoCAD SHX Text
%%UPLAN LEGEND:
AutoCAD SHX Text
EXISTING 1 HOUR SEPARATION
AutoCAD SHX Text
EXISTING 2 HR FIRE WALL
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
VEST.
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OPEN OFF.
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
JAN.
AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text
NOTE: HATCH INDICATES AREA OF WORK
AutoCAD SHX Text
VEST.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
DATA
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text %%UBUILDING #1 AREA = 16,577 s.f.
AutoCAD SHX Text %%UBUILDING #2 AREA = 12,617 s.f.
AutoCAD SHX Text
FOLLOW 2 HR. FIRE WALL - CONSTRUCTION, ;MARCH 2002
AutoCAD SHX Text
FOLLOW 2 HR. FIRE WALL - CONSTRUCTION, ;1997, MAR. 2002
AutoCAD SHX Text
EXIST'G 2 HR FIRE WALL
AutoCAD SHX Text
EXIST'G 2 HR FIRE WALL
AutoCAD SHX Text
EX. 2 HR FIRE WALL
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 1 HOUR WALL
AutoCAD SHX Text
EX. 1 HR. WALL
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 2 HR.
AutoCAD SHX Text
EX. 2 HR.
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EX. 1 HR.
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EXIST'G 1 HOUR WALL
AutoCAD SHX Text
EX. 2 HR FIRE WALL
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
LIFE SAFETY FLOOR PLAN
AutoCAD SHX Text
SCALE 3/32" = 1'-0"
AutoCAD SHX Text
PROPOSED 1 HOUR SEPARATION
AutoCAD SHX Text
PROPOSED 2 HOUR SEPARATION
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text
SENS.
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
TLT.
AutoCAD SHX Text
SENS.
AutoCAD SHX Text
NURSE
AutoCAD SHX Text
SENS.
AutoCAD SHX Text
PROPOSED 2 HOUR WALL
AutoCAD SHX Text
PROPOSED 2 HOUR WALL
AutoCAD SHX Text
NEW 1 HOUR WALL
AutoCAD SHX Text
NEW 1 HOUR WALL
AutoCAD SHX Text
NEW 1 HOUR WALL
AutoCAD SHX Text 771 S.F.
AutoCAD SHX Text 899 S.F.
AutoCAD SHX Text 653 S.F.
PROPOSED BUSINESS = 8,513 s.f. PROPOSED EDUCATIONAL = 4,104 s.f.
D1.0
ARCHITECTURE
CONSTRUCTION MANAGEMENT
DEVELOPMENT
1104 S. MITCHELL ST.
CADILLAC, MICHIGAN 49601
(231) 779-4002
(231) 779-4022 FAX
ARCHITECT OF RECORD:
DRAWN BY:
PROJECT NUMBER:
SHEET NUMBER:
DATE ISSUED:
THE
DESIGN GROUP
D. DeKryger
K. Taylor
April 23, 2026 Bidding & Construction
25123B
Pr op os ed
R en ov at io n fo r:
W ex fo rd
-M is sa uk ee
IS
D Sp ec ia l S er vi ce s Bu ild in g
E
. 1 3t h St re et
Ca di lla c, M I 4
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UBOARD ROOM
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%URECORDS
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%ULOUNGE
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UWORK
AutoCAD SHX Text KEYED PLAN DEMOLITION NOTES: REMOVE EXISTING WALL, COMPLETE, TO LIMITS SHOWN ON PLAN. REMOVE EXISTING WALL CONSTRUCTION AS REQ'D TO CREATE NEW OPENING FOR NEW DOOR OR WINDOW & HEADER, SHORE AS REQ'D. SEE NEW WORK PLAN FOR EXACT LOCATIONS. REMOVE EXISTING DOOR, FRAME, TRIM & HARDWARE, COMPLETE. REMOVE EXISTING WINDOW, FRAME, TRIM & HARDWARE, COMPLETE. REMOVE / REWORK EXISTING WINDOW & FRAME AS REQ'D TO INSTALL NEW ESCAPE WINDOW OR EGRESS DOOR. SEE NEW WORK PLAN. REMOVE EXISTING WALL CONSTRUCTION AS REQ'D TO INSTALL NEW EGRESS DOOR. SEE NEW WORK PLAN.
AutoCAD SHX Text GENERAL DEMOLITION / NEW WORK NOTES: 1. CONTRACTOR SHALL VISIT THE SITE TO VERIFY ALL EXISTING CONTRACTOR SHALL VISIT THE SITE TO VERIFY ALL EXISTING CONDITIONS PRIOR TO THE BID SUBMISSION/ START OF DEMOLITION ACTIVITIES. 2. PROVIDE ALL REQUIRED/ NECESSARY SHORING AND BRACING AS PROVIDE ALL REQUIRED/ NECESSARY SHORING AND BRACING AS REQUIRED DURING DEMOLITION OPERATION(S). 3. PROVIDE PROTECTION FOR EXISTING CONSTRUCTION TO REMAIN. PROVIDE PROTECTION FOR EXISTING CONSTRUCTION TO REMAIN. PATCH AND REPAIR ALL AREAS DAMAGED DURING DEMOLITION / CONSTRUCTION. MATCH EXISTING CONSTRUCTION, MATERIALS AND FINISHES. TYPICAL AT ALL LOCATIONS. 4. EACH CONTRACTOR INVOLVED IN DEMOLITION SHALL REMOVE AND EACH CONTRACTOR INVOLVED IN DEMOLITION SHALL REMOVE AND PROPERLY DISPOSE OF ALL REFUSE AND MATERIALS FROM DEMOLITION OPERATION. 5. DEMOLITION FOR INSTALLATION OF MECHANICAL, ELECTRICAL, AND DEMOLITION FOR INSTALLATION OF MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS SHALL BE PROVIDED BY THE TRADE INSTALLING THOSE ITEMS OR AS DIRECTED BY THE GENERAL CONTRACTOR. TRADE PROVIDING DEMOLITION SHALL PATCH TO MATCH EXISTING AS REQUIRED. SEE PLUMBING, MECHANICAL & ELECTRICAL SHEETS FOR SEE PLUMBING, MECHANICAL & ELECTRICAL SHEETS FOR MORE INFORMATION. 6. ALL DIMENSIONS ARE APPROXIMATE. FIELD MEASURE BEFORE ALL DIMENSIONS ARE APPROXIMATE. FIELD MEASURE BEFORE FABRICATION / ORDERING & INSTALLATION OF ANY NEW MATERIALS. 7. EXISTING CONSTRUCTION SHALL BE REMOVED / MODIFIED / EXISTING CONSTRUCTION SHALL BE REMOVED / MODIFIED / REWORKED AS REQUIRED TO COMPLETE NEW WORK. 8. SAWCUT & REMOVE EXISTING CONCRETE SLAB AS REQ'D TO TIE NEW SAWCUT & REMOVE EXISTING CONCRETE SLAB AS REQ'D TO TIE NEW PLUMBING SANITARY PIPING INTO EXISTING. 9. EXISTING FLOOR FINISHES & CEILING FINISHES SHALL BE REMOVED / EXISTING FLOOR FINISHES & CEILING FINISHES SHALL BE REMOVED / MODIFIED / REWORKED AS REQUIRED @ AREAS OF NEW WORK. 10. REPORT TO THE ARCHITECT ANY POTENTIAL ISSUES UNCOVERED REPORT TO THE ARCHITECT ANY POTENTIAL ISSUES UNCOVERED DURING DEMOLITION WORK.
AutoCAD SHX Text
PLAN LEGEND: EXISTING 1 HOUR WALL EXISTING 2 HOUR WALL
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
EXISTING / DEMOLITION FLOOR PLAN
AutoCAD SHX Text
SCALE 1/8" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text D1.0
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3,4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text CAREFULLY REMOVE EXISTING DISPLAY CASE AND ADJACENT WING WALLS AS REQ'D TO INSTALL NEW WORK. SAVE FOR REINSTALLATION. SEE NEW WORK PLAN.
AutoCAD SHX Text REMOVE EXISTING CERAMIC TILE BASE & WOOD BASE & WALL TRIM @ LOBBY / CORRIDOR WALL AS REQ'D TO INSTALL NEW WORK. SEE NEW WORK PLAN
AutoCAD SHX Text
EX.
AutoCAD SHX Text
DATA
AutoCAD SHX Text
%%UROOM
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UTOILET
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%ULOBBY
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UCORRIDOR
AutoCAD SHX Text
EX. CORRIDOR
AutoCAD SHX Text
EX. TOILET
AutoCAD SHX Text
EX. CORRIDOR
AutoCAD SHX Text
EX. VESTIBLE
AutoCAD SHX Text
EX. STORAGE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. CONFERENCE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. CONFERENCE
AutoCAD SHX Text
EX. MEN'S RESTROOM
AutoCAD SHX Text
EX. WOMEN'S RESTROOM
AutoCAD SHX Text
EX. STORAGE
AutoCAD SHX Text
EX. MECHANICAL
AutoCAD SHX Text
EX. JAN.
AutoCAD SHX Text
EX. RECEPTION
AutoCAD SHX Text
EX. VESTIBLE
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%ULOBBY
AutoCAD SHX Text
EX. STORAGE
AutoCAD SHX Text
NOTE: HATCH INDICATES AREA OF WORK
AutoCAD SHX Text 3'-5"
AutoCAD SHX Text 3'-4"
AutoCAD SHX Text 3'-4"
AutoCAD SHX Text 3'-4"
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text 3'-4"
AutoCAD SHX Text ALTERNATE NO. 1 REMOVE EXISTING CASEWORK, SINK AND FLOOR AS REQ'D TO INSTALL NEW WORK. SEE ARCHITECTURAL, PLUMBING & ELECTRICAL NEW WORK PLANS FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text REMOVE / REWORK EXISTING ALUM. BUTT GLAZED WINDOW & FRAME AS REQ'D TO INSTALL NEW ESCAPE WINDOW. SEE NEW WORK PLAN / ELEVATIONS.
AutoCAD SHX Text REMOVE / REWORK EXISTING ALUM. BUTT GLAZED WINDOW & FRAME AS REQ'D TO INSTALL NEW ESCAPE WINDOW. SEE NEW WORK PLAN / ELEVATIONS.
AutoCAD SHX Text REMOVE EXISTING WALL CONSTRUCTION AS REQ'D TO INSTALL NEW EGRESS DOOR. SEE NEW WORK PLAN.
AutoCAD SHX Text %%uPARTIAL EXISTING / DEMO NORTH ELEVATION
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text REMOVE / REWORK EXISTING ALUM. BUTT GLAZED WINDOW & FRAME AS REQ'D TO INSTALL NEW ESCAPE WINDOW. SEE NEW WORK PLAN / ELEVATIONS.
AutoCAD SHX Text %%uPARTIAL EXISTING / DEMO SOUTH ELEVATION
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text SAWCUT & REMOVE EXISTING CONC. FOUNDATION WALL AS REQ'D TO INSTALL NEW EGRESS DOOR & EXTERIOR CONCRETE PAD.
AutoCAD SHX Text REMOVE / REWORK EXISTING ALUM. BUTT GLAZED WINDOW & FRAME AS REQ'D TO INSTALL NEW EGRESS DOOR.
AutoCAD SHX Text REMOVE EXISTING STUD & BRICK WALL CONSTRUCTION AS REQ'D TO INSTALL NEW EGRESS DOOR.
AutoCAD SHX Text
AutoCAD SHX Text D1.0
AutoCAD SHX Text %%uEXIST / DEMO WALL SECTION
3/4" = 1'-0"
General notes:
1. Contractor shall verify all existing field conditions and notify architect immediately if that which exists differs from that which is shown on drawings.
2. All work to comply with current Federal, State and Local codes, laws and ordinances.
The requirements of ICC/ANSI A117.1 and the Americans with disabilities act (ADA) are to be fully satisfied. All work shall meet the most stringent requirements of both including, but not limited to clearances, limitations, accessories, etc.
3. These drawings are prepared in accordance with the limited services for which the architect was contracted. The architect makes no representation that the interpretation of these documents will result in complete compliance with the ADA.
4. All doors required to be labeled shall be set in labeled frames and identified with UL label and be provided with approved self-closing devices and positive latching hardware.
5. All designated exit doors shall be equipped with the required egress hardware.
6. Furnish hardware as scheduled without substitution, no alternates will be approved.
7. Provide Combinated Cylinders and Cut keys; keyed to Owners' Master Key System. Include key conference and key system schedule. Furnish two cut keys for each locking device specified.
8. Furnish and provide all necessary reinforcements, brackets, fasteners, spacers and fillers to provide a complete functioning opening.
9. Provide complete shop drawings, submittals and cut sheets complying with DHI prescribed methods and vertical format double spaced hardware schedule.
10. All access control modules, fobs and readers, to be furnished by Security Vender under a separate section. Line voltage, circuits, cable and installation of power supplies for controllers and access control peripherals to be furnished and installed by electrical contractor.
Hardware Set 1 - Entry Lock [Lock / Unlock] + Closer 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Entry Lockset MR 116 BJEJ 32D PDQ 1 ea. Mortise Cylinder -Match Existing 26D ---- 1 ea. Closer 7101BC RA Regular Arm (pull side mount)689 PDQ 1 ea. Kickplate 90 10 x 2” LDW 32D Don Jo 1 ea. Wall Stop 1407 26D Don Jo
Hardware Set 2 - Classroom Lock [Lock / Unlock] + Closer 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Classroom Lock MR 148 BJEJ 32D PDQ 1 ea. Mortise Cylinder -Match Existing 26D ---- 1 ea. Closer 7101 BC EDA (push side mount) 689 PDQ 1 ea. Kickplate 90 10 x 2” LDW 32D Don Jo 1 ea. Wall Stop 1407 26D Don Jo
Hardware Set 3 - Entry Lock [Lock / Unlock] + Closer & Smoke Seal 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Entry Lockset MR 116 BJEJ 32D PDQ 1 ea. Mortise Cylinder -Match Existing 26D ---- 1 ea. Closer 7101BC RA Regular Arm (pull side mount689 PDQ 1 ea. Kickplate 90 10 x 2” LDW 32D Don Jo 1 ea. Wall Stop 1407 26D Don Jo 1 set Smoke Seal 797B Black Reese
Hardware Set 4 - Classroom Lock [Lock / Unlock] + Closer & Smoke Seal 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Classroom Lock MR 148 BJEJ 32D PDQ 1 ea. Mortise Cylinder -Match Existing 26D ---- 1 ea. Closer 7101 BC EDA (push side mount) 689 PDQ 1 ea. Kickplate 90 10 x 2” LDW 32D Don Jo 1 ea. Wall Stop 1407 26D Don Jo 1 set Smoke Seal 797B Black Reese
Hardware Set 5 - Classroom Lock [Lock / Unlock] 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Classroom Lock MR 148 BJEJ 32D PDQ 1 ea. Mortise Cylinder -Match Existing 26D ---- 1 ea. Wall Stop 1407 26D Don Jo
Hardware Set 6 - Privacy Set w/ Indicator [Lock / Unlock] + Closer 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Privacy Set w/ Indicator MR 279 BJEJ 32D PDQ 1 ea. Closer 7101BC RA Regular Arm (pull side mount)689 PDQ 1 ea. Kickplate 90 10 x 2” LDW B4E 32D Don Jo 1 ea. Wall Stop 1407 26D Don Jo
Hardware Set 7 - Rim Panic w/ Pull Trim [Lock / Unlock] + Closer Stop 3 ea. Butt Hinge BB51 4 ½” x 4 ½” NRP 32D PBB 1 ea. Rim Panic Device 6300R CD (03) 32D PDQ 1 ea. Rim Cylinder -Match Existing (03) 26D ---- 1 ea. Mortise Cylinder -Match Existing (CD) 26D ---- 1 set Offset Pull 1157 x 4 134 Mount 32D Don Jo 1 ea. Closer 7101 BC SCS Stop 689 PDQ 1 ea. Kickplate 90 10 x 2” LDW B4E 32D Don Jo 1 ea. Threshold S205A AL Reese 1 ea. Sweep 354C AL Reese 1 set Weatherstrip 855C (mount prior to closer shoe & strike)AL Reese 1 ea. Rain Drip R201 AL Reese
Hardware Set 8 - Classroom Lock [Lock / Unlock] + Closer & Smoke Seal 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Classroom Lock MR 148 BJEJ 32D PDQ 1 ea. Mortise Cylinder -Match Existing 26D ---- 1 ea. Closer 7101BC RA Regular Arm (pull side mount)689 PDQ 1 ea. Kickplate 90 10 x 2” LDW 32D Don Jo 1 ea. Wall Stop 1407 26D Don Jo 1 set Smoke Seal 797B Black Reese
Hardware Set 9 - Privacy Set w/ Indicator [Lock / Unlock] + Closer & Smoke Seal 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Privacy Set w/ Indicator MR 279 BJEJ 32D PDQ 1 ea. Closer 7101BC RA Regular Arm (pull side mount)689 PDQ 1 ea. Kickplate 90 10 x 2” LDW B4E 32D Don Jo 1 ea. Wall Stop 1407 26D Don Jo 1 set Smoke Seal 797B Black Reese
Hardware Set 10 - Classroom Lock [Lock / Unlock] + Closer 3 ea. Butt Hinge BB81 4 ½” x 4 ½” NRP 26D PBB 1 ea. Classroom Lock MR 148 BJEJ 32D PDQ 1 ea. Mortise Cylinder -Match Existing 26D ---- 1 ea. Closer 7101BC RA Regular Arm (pull side mount)689 PDQ 1 ea. Kickplate 90 10 x 2” LDW 32D Don Jo 1 ea. Wall Stop 1407 26D Don Jo
A1.0
ARCHITECTURE
CONSTRUCTION MANAGEMENT
DEVELOPMENT
1104 S. MITCHELL ST.
CADILLAC, MICHIGAN 49601
(231) 779-4002
(231) 779-4022 FAX
ARCHITECT OF RECORD:
DRAWN BY:
PROJECT NUMBER:
SHEET NUMBER:
DATE ISSUED:
THE
DESIGN GROUP
D. DeKryger
K. Taylor
April 23, 2026 Bidding & Construction
25123B
Pr op os ed
R en ov at io n fo r:
W ex fo rd
-M is sa uk ee
IS
D Sp ec ia l S er vi ce s Bu ild in g
E
. 1 3t h St re et
Ca di lla c, M I 4
AutoCAD SHX Text
PLAN LEGEND: EXISTING 1 HOUR WALL EXISTING 2 HOUR WALL
AutoCAD SHX Text
NOTE: HATCH INDICATES AREA OF WORK
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%UCLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
EX.
AutoCAD SHX Text
DATA
AutoCAD SHX Text
%%UROOM
AutoCAD SHX Text
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%USENSORY
AutoCAD SHX Text
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UTOILET
AutoCAD SHX Text
AutoCAD SHX Text
COMMON
AutoCAD SHX Text
%%UAREA
AutoCAD SHX Text
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%ULOBBY
AutoCAD SHX Text
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%USENSORY
AutoCAD SHX Text
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%UCLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%UTOILET
AutoCAD SHX Text
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%UCLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text PROPOSED 1 HOUR WALL (WALL TYPES 1 & 1A) PROPOSED 2 HOUR WALL (WALL TYPES 2 & 2A)
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%USENSORY
AutoCAD SHX Text
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%UNURSE
AutoCAD SHX Text
AutoCAD SHX Text NEW ESCAPE WINDOW INSTALLED IN EXISTING MODIFIED STOREFRONT WINDOW FRAMING. SEE EXTERIOR ELEVATIONS.
AutoCAD SHX Text
EX.
AutoCAD SHX Text
%%UCORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A1.1
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%UTOILET
AutoCAD SHX Text
AutoCAD SHX Text NEW ESCAPE WINDOW INSTALLED IN EXISTING MODIFIED STOREFRONT WINDOW FRAMING. SEE EXTERIOR ELEVATIONS.
AutoCAD SHX Text
NEW EGRESS DOOR
AutoCAD SHX Text 6'-7"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
AutoCAD SHX Text 2A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text REINSTALL EXISTING DISPLAY CASE AND ADJACENT WING WALLS AFTER NEW GYP @ 2 HOUR WALL HAS BEEN APPLIED.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2A
AutoCAD SHX Text 2A
AutoCAD SHX Text 1A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1A
AutoCAD SHX Text 1A
AutoCAD SHX Text
AutoCAD SHX Text 1A
AutoCAD SHX Text
AutoCAD SHX Text 1A
AutoCAD SHX Text 1A
AutoCAD SHX Text 2B
AutoCAD SHX Text 1A
AutoCAD SHX Text
SIM.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EX. CORRIDOR
AutoCAD SHX Text
EX. TOILET
AutoCAD SHX Text
EX. CORRIDOR
AutoCAD SHX Text
EX. VESTIBLE
AutoCAD SHX Text
EX. STORAGE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. CONFERENCE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. OFFICE
AutoCAD SHX Text
EX. CONFERENCE
AutoCAD SHX Text
EX. MEN'S RESTROOM
AutoCAD SHX Text
EX. WOMEN'S RESTROOM
AutoCAD SHX Text
EX. STORAGE
AutoCAD SHX Text
EX. MECHANICAL
AutoCAD SHX Text
EX. JAN.
AutoCAD SHX Text
EX. RECEPTION
AutoCAD SHX Text
EX. VESTIBLE
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
NEW WORK FLOOR PLAN
AutoCAD SHX Text
SCALE 1/8" = 1'-0"
AutoCAD SHX Text F3638
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 109B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 109A
AutoCAD SHX Text
AutoCAD SHX Text 112A
AutoCAD SHX Text
ETR
AutoCAD SHX Text
AutoCAD SHX Text 112B
AutoCAD SHX Text 112C
AutoCAD SHX Text
ETR
AutoCAD SHX Text AT NEW WINDOW F80310, PROVIDE & INSTALL NEW 1-12-HR COILING/ROLLING FIRE SHUTTER (OFFICE SIDE, SEE SPEC) IN BULKHEAD ABOVE NEW INTERIOR WINDOW, MODIFY BULKHEAD AS REQUIRED.
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text 2A
AutoCAD SHX Text 2A
AutoCAD SHX Text
ABOVE TO DECK
AutoCAD SHX Text
ABOVE TO DECK
AutoCAD SHX Text
FLR. TO ROOF DECK
AutoCAD SHX Text
FLR. TO ROOF DECK
AutoCAD SHX Text
FLR. TO ROOF DECK
AutoCAD SHX Text 2A
AutoCAD SHX Text 2A
AutoCAD SHX Text
ABOVE TO ROOF DECK
AutoCAD SHX Text F80310
AutoCAD SHX Text ALTERNATE NO. 1 INSTALL NEW PLUMBING & ELECTRICAL. PATCH WALLS & SLAB. INSTALL NEW PAINTED WALL TYPE 3 IN EXISTING OPN'G WITH DOOR TYPE 3 (45 MIN), FRAME TYPE B (45 MIN) w/ HWDE SET 4, LVT FLOORING & 4" VINYL BASE. MODIFY GYP. BRD./ ACOUST. CLG. AS REQ'D. EXTERIOR FINISHES SHALL MATCH COMMON AREA 103.
AutoCAD SHX Text PROPOSED EAST WALL, TYPE 2 & 2A ALONG EX. LOBBY 100 & CORRIDOR 101 ONCE NEW WALL TYPE 2A IS INSTALLED TO EXISTING ROOF DECK, INSTALL INTUMESCENT COATING TO EX. ROOF DECK, 4'-0" EACH SIDE OF WALL TYPE 2A.
AutoCAD SHX Text
NAME
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
ROOM FINISH SCHEDULE
AutoCAD SHX Text
WALL
AutoCAD SHX Text
NO.
AutoCAD SHX Text
ROOMS
AutoCAD SHX Text
FIN.
AutoCAD SHX Text
BASE
AutoCAD SHX Text
MAT'L
AutoCAD SHX Text
FIN.
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
HT.
AutoCAD SHX Text
MAT'L
AutoCAD SHX Text
FIN.
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text LEGEND: ETR EXISTING TO REMAIN EXISTING TO REMAIN LVT LUXURY VINYL TILE/PLANK LUXURY VINYL TILE/PLANK CPT CARPET TILE CARPET TILE 4" VINYL 4" VINYL BASE 4" VINYL BASE WD/WOOD WOOD BASE TRIM - MATCH EXISTING WOOD BASE TRIM - MATCH EXISTING CT CERMIC TILE BASE - MATCH EXISTING CERMIC TILE BASE - MATCH EXISTING GYP GYPSUM DRYWALL GYPSUM DRYWALL MR GYP MOISTURE RESISTANT GYPSUM DRYWALL MOISTURE RESISTANT GYPSUM DRYWALL ACT ACOUSTIC CEILING TILE & GRID ACOUSTIC CEILING TILE & GRID FF FACTORY FINISHFACTORY FINISH
AutoCAD SHX Text
EXISTING LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
LVT
AutoCAD SHX Text
AutoCAD SHX Text NOTES: 1. VERIFY & COORDINATE ALL FINISHES W/ OWNER PRIOR TO THE START OF CONSTRUCTION. VERIFY & COORDINATE ALL FINISHES W/ OWNER PRIOR TO THE START OF CONSTRUCTION. 2. EXISTING FLOOR FINISHES & CEILING FINISHES SHALL BE REMOVED / MODIFIED / REWORKED AS EXISTING FLOOR FINISHES & CEILING FINISHES SHALL BE REMOVED / MODIFIED / REWORKED AS REQUIRED @ AREAS OF NEW WORK. 3. ALL OWNER/ CONTRACTOR SELECTED PRODUCTS SHALL BE INSTALLED PER MANUFACTURERS ALL OWNER/ CONTRACTOR SELECTED PRODUCTS SHALL BE INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS, RECOMMENDATIONS AND/OR REQUIREMENTS. INSTALLATION SHALL MEET OR EXCEED ALL APPLICABLE CODES AND INDUSTRY STANDARDS.
AutoCAD SHX Text
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
AutoCAD SHX Text
ETR/MR GYP
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
DOOR LOCATION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
GLAZING
AutoCAD SHX Text
FRAME
AutoCAD SHX Text
HDWR
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text W
AutoCAD SHX Text H
AutoCAD SHX Text
NO.
AutoCAD SHX Text B
AutoCAD SHX Text
DOOR FRAMES
AutoCAD SHX Text
DOOR TYPES
AutoCAD SHX Text NOTES: 1. SEE SCHEDULE FOR GLAZING TYPE. SEE SCHEDULE FOR GLAZING TYPE. 2. NEW DOORS SHALL MATCH EXISTING TO REMAIN DOORS NEW DOORS SHALL MATCH EXISTING TO REMAIN DOORS WOOD SPECIES & STAIN COLOR, V.I.F.
AutoCAD SHX Text A
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ALUM. INSUL. HALF LITE
AutoCAD SHX Text
SOLID CORE WOOD | LITE
AutoCAD SHX Text
SEE SCHED
AutoCAD SHX Text
SEE SCHED
AutoCAD SHX Text
SEE SCHED
AutoCAD SHX Text
SEE SCHED
AutoCAD SHX Text
AutoCAD SHX Text
SOLID CORE WOOD
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 3"x33" |" WIRE
AutoCAD SHX Text
COMMON AREA
AutoCAD SHX Text
NEW NURSE
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
NEW SENSORY
AutoCAD SHX Text 109B
AutoCAD SHX Text
NEW B.F. TOILET
AutoCAD SHX Text
AutoCAD SHX Text 109A
AutoCAD SHX Text
100 MAX. SQ.IN. GLAZING
AutoCAD SHX Text
1" INSUL. TEMPERED
AutoCAD SHX Text
AutoCAD SHX Text
H.M. - WELDED
AutoCAD SHX Text
HARDWARE SETS
AutoCAD SHX Text
AutoCAD SHX Text
4" VINYL
AutoCAD SHX Text
4" VINYL
AutoCAD SHX Text
CPT
AutoCAD SHX Text
CPT
AutoCAD SHX Text
CPT
AutoCAD SHX Text
CPT
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
NEW SENSORY
AutoCAD SHX Text
EXISTING B.F. TOILET
AutoCAD SHX Text
AutoCAD SHX Text 112A
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text 112B
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text 112C
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
NEW SENSORY
AutoCAD SHX Text
NEW B.F. TOILET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
FIRE R
AutoCAD SHX Text
90 MIN.
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
100 MAX. SQ.IN. GLAZING
AutoCAD SHX Text
90 MIN.
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
100 MAX. SQ.IN. GLAZING
AutoCAD SHX Text
90 MIN.
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
100 MAX. SQ.IN. GLAZING
AutoCAD SHX Text
90 MIN.
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
20 MIN.
AutoCAD SHX Text
|" WIRE
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
20 MIN.
AutoCAD SHX Text
|" WIRE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
20 MIN.
AutoCAD SHX Text
|" WIRE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
|" WIRE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
20 MIN.
AutoCAD SHX Text
20 MIN.
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
20 MIN.
AutoCAD SHX Text
|" WIRE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
20 MIN.
AutoCAD SHX Text
|" WIRE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
|" WIRE
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
|" WIRE
AutoCAD SHX Text
20 MIN.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3"x33" |" WIRE
AutoCAD SHX Text 3"x33" |" WIRE
AutoCAD SHX Text 3"x33" |" WIRE
AutoCAD SHX Text
EXISTING CORRIDOR
AutoCAD SHX Text
COMMON AREA
AutoCAD SHX Text
NEW NURSE
AutoCAD SHX Text
EXISTING OFFICE
AutoCAD SHX Text
EXISTING OFFICE
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text
NEW SENSORY
AutoCAD SHX Text
NEW B.F. TOILET
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text
NEW SENSORY
AutoCAD SHX Text
EXISTING B.F. TOILET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
NEW SENSORY
AutoCAD SHX Text
NEW B.F. TOILET
AutoCAD SHX Text
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR/NEW WD
AutoCAD SHX Text
ETR/NEW CT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
LVT
AutoCAD SHX Text
LVT
AutoCAD SHX Text
CPT
AutoCAD SHX Text
CPT
AutoCAD SHX Text
CPT
AutoCAD SHX Text
CPT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR/NEW WD
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
EXISTING DATA ROOM
AutoCAD SHX Text
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
ETR/MR GYP
AutoCAD SHX Text
ETR/MR GYP
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR/PAINT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR/FF
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
ETR/ACT
AutoCAD SHX Text
EXISTING GYP. BULKHEAD TO REMAIN, REPAINT
AutoCAD SHX Text
PAINT/FF
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
ETR/PAINT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR/PAINT
AutoCAD SHX Text
ETR/PAINT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ACT
AutoCAD SHX Text
FF
AutoCAD SHX Text
MATCH EX.
AutoCAD SHX Text
INSTALL NEW ACT AT HEIGHT OF EX. REMOVED BULKHEAD
AutoCAD SHX Text
ACT
AutoCAD SHX Text
FF
AutoCAD SHX Text
MATCH EX.
AutoCAD SHX Text
INSTALL NEW ACT AT HEIGHT OF EX. REMOVED BULKHEAD
AutoCAD SHX Text
ETR/NEW WD
AutoCAD SHX Text
ACT
AutoCAD SHX Text
FF
AutoCAD SHX Text
MATCH EX.
AutoCAD SHX Text
INSTALL NEW ACT AT HEIGHT OF EX. REMOVED BULKHEAD
AutoCAD SHX Text
ETR/ACT
AutoCAD SHX Text
FF
AutoCAD SHX Text
ETR/NEW WD
AutoCAD SHX Text
MATCH EX.
AutoCAD SHX Text
MATCH EX.
AutoCAD SHX Text
ACT
AutoCAD SHX Text
FF
AutoCAD SHX Text
MATCH EX.
AutoCAD SHX Text
ETR/NEW WD
AutoCAD SHX Text
ACT
AutoCAD SHX Text
FF
AutoCAD SHX Text
MATCH EX.
AutoCAD SHX Text
4" VINYL
AutoCAD SHX Text
ETR/NEW CT
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ETR
AutoCAD SHX Text
ACT
AutoCAD SHX Text
FF
AutoCAD SHX Text
MATCH EX.
AutoCAD SHX Text
ETR/NEW WD
AutoCAD SHX Text
ETR/NEW WD
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2, MATCH FLR. & BASE AS REQUIRED
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ETR/GYP
AutoCAD SHX Text
NO WORK THIS ROOM.
AutoCAD SHX Text NOTES: 1. EXISTING FIRE RATED WALLS ARE FROM EX. CONC SLAB TO B.O. EX. ROOF TRUSS & EX. EXISTING FIRE RATED WALLS ARE FROM EX. CONC SLAB TO B.O. EX. ROOF TRUSS & EX. GYP. BRD., AS TAKEN FROM EXISTING CONSTRUCTION DOCUMENTS CREATED BY THA ARCHITECTS / ENGINEERS, FLINT, MI: DATED MARCH 15, 2002. IF FOUND OTHERWISE, REPORT TO CURRENT ARCHITECT (THE DK DESIGN GROUP). 2. ALL NEW WALLS & FINISHES SHALL EXTEND FROM EX. CONC SLAB TO B.O. EX. ROOF RUSS ALL NEW WALLS & FINISHES SHALL EXTEND FROM EX. CONC SLAB TO B.O. EX. ROOF RUSS & EX. GYP. BRD. PROVIDE SOUND INSULATION & FIRE CAULKING TO EXISTING. 3. USE MOISTURE RESISTANT GYPSUM BOARD IN ALL BATHROOMS. USE MOISTURE RESISTANT GYPSUM BOARD IN ALL BATHROOMS. 4. SEE ROOM FINISH SCHEDULE FOR WALL FINISHES.SEE ROOM FINISH SCHEDULE FOR WALL FINISHES.
AutoCAD SHX Text
AutoCAD SHX Text 1A
AutoCAD SHX Text
AutoCAD SHX Text 2A
AutoCAD SHX Text
WALL TYPES LEGEND
AutoCAD SHX Text 2B
AutoCAD SHX Text CONVERT EXISTING 1 HR. WALL TO 2 HOUR WALL (UL# U408 - 2 HOUR) LOBBY / CORRIDOR SIDE NEW (2) LAYERS }" TYPE 'X' (FIRE-SHIELD) GYPSUM BOARD (2) LAYERS }" TYPE 'X' (FIRE-SHIELD) GYPSUM BOARD EXIST. (1) LAYER }" GYPSUM BOARD (1) LAYER }" GYPSUM BOARD EXIST. 6" METAL STUDS 6" METAL STUDS EXIST. (1) LAYER }" GYPSUM BOARD(1) LAYER }" GYPSUM BOARD
AutoCAD SHX Text NEW 2 HOUR INFILL WALL (UL# U408 - 2 HOUR) LOBBY / CORRIDOR SIDE (3) LAYERS }" TYPE 'X' (FIRE-SHIELD) GYPSUM BOARD 6" METAL STUDS @ 16" O.C. (VERIFY SIZE w/ ADJACENT EXISTING WALL) FIBERGLASS SOUND INSULATION BATT (1) LAYER }" TYPE 'X' (FIRE-SHIELD) GYPSUM BOARD
AutoCAD SHX Text EXISTING WALL MEETS 1 HR. WALL (UL# U419 - 1 HOUR) EXIST. (1) LAYER }" GYPSUM BOARD (1) LAYER }" GYPSUM BOARD EXIST. 6" METAL STUDS 6" METAL STUDS EXIST. (1) LAYER }" GYPSUM BOARD(1) LAYER }" GYPSUM BOARD
AutoCAD SHX Text NEW 1 HOUR INFILL WALL (UL# U419 - 1 HOUR) (1) LAYER }" TYPE 'X' (FIRE-SHIELD) GYPSUM BOARD 6" METAL STUDS @ 16" O.C. (VERIFY SIZE w/ ADJACENT EXISTING WALL) FIBERGLASS SOUND INSULATION BATT (1) LAYER }" TYPE 'X' (FIRE-SHIELD) GYPSUM BOARD
AutoCAD SHX Text EXISTING WALL MEETS 2 HR. RATING EXIST. BRICK BRICK EXIST. 6" METAL STUDS 6" METAL STUDS EXIST. BRICK BRICK NOTE: BRICK (2) HOUR RATING REQUIRES 3.4" - 3.8" BRICK, (2) LAYERS. MBC TABLE 722.4.1(1)
AutoCAD SHX Text
AutoCAD SHX Text NEW INTERIOR WALL (1) LAYER }" GYPSUM BOARD }" GYPSUM BOARD 3}" METAL STUDS @ 16" O.C. FIBERGLASS SOUND INSULATION BATT (1) LAYER }" GYPSUM BOARD }" GYPSUM BOARD
AutoCAD SHX Text
AutoCAD SHX Text NEW INTERIOR WALL (1) LAYER }" GYPSUM BOARD 6" METAL STUDS @ 16" O.C. FIBERGLASS SOUND INSULATION BATT (1) LAYER }" GYPSUM BOARD
AutoCAD SHX Text
INTERIOR WINDOWS
AutoCAD SHX Text ;3'-10"
AutoCAD SHX Text ;8'-0"
AutoCAD SHX Text F80310
AutoCAD SHX Text
FIXED
AutoCAD SHX Text ;1'-5"
AutoCAD SHX Text 2'-2"
AutoCAD SHX Text ;1'-5"
AutoCAD SHX Text 2'-2"
AutoCAD SHX Text ;3'-8"
AutoCAD SHX Text ;3'-6"
AutoCAD SHX Text F3638
AutoCAD SHX Text NOTES: 1. 2" H.M. FRAMES, TYPICAL. 2" H.M. FRAMES, TYPICAL. 2. SIZE FRAMES AS REQ'D TO FIT EXISTING OPENINGS. SIZE FRAMES AS REQ'D TO FIT EXISTING OPENINGS. 3. VERIFY WALL THICKNESS FOR THROAT SIZE. VERIFY WALL THICKNESS FOR THROAT SIZE. 4. GLAZING SHALL BE |" WIRE GLASS GLAZING SHALL BE |" WIRE GLASS 5. FRAMES SHALL BE PAINTED COLOR AS SELECTED BY OWNER.FRAMES SHALL BE PAINTED COLOR AS SELECTED BY OWNER.
FIXED 20 MINUTE RATED
A1.1
CONSTRUCTION MANAGEMENT
DEVELOPMENT
1104 S. MITCHELL ST.
CADILLAC, MICHIGAN 49601
(231) 779-4002
(231) 779-4022 FAX
ARCHITECT OF RECORD:
DRAWN BY:
PROJECT NUMBER:
SHEET NUMBER:
DATE ISSUED:
THE
DESIGN GROUP
D. DeKryger
K. Taylor
April 23, 2026 Bidding & Construction
25123B
Pr op os ed
R en ov at io n fo r:
W ex fo rd
-M is sa uk ee
IS
D Sp ec ia l S er vi ce s Bu ild in g
E
. 1 3t h St re et
Ca di lla c, M I 4
AutoCAD SHX Text
REWORKED EXISTING ALUM. WINDOW GLAZING / FRAME & NEW EGRESS DOOR.
AutoCAD SHX Text %%uPARTIAL NEW WORK NORTH ELEVATION
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text NEW QUAKER M600 CASEMENT (PUSH-OUT) ESCAPE WINDOW (;3'-10"W x 3'-8"H, VERIFY) INSTALLED IN EXISTING ALUM. STOREFRONT WINDOW FRAMING.
AutoCAD SHX Text NEW QUAKER M600 CASEMENT (PUSH-OUT) ESCAPE WINDOW (;3'-10"W x 3'-8"H, VERIFY) INSTALLED IN EXISTING ALUM. STOREFRONT WINDOW FRAMING.
AutoCAD SHX Text %%uPARTIAL NEW WORK SOUTH ELEVATION
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
NEW CONC. PAD @ DOOR. SEE CIVIL PLAN FOR MORE DETAILS.
AutoCAD SHX Text
NEW EGRESS DOOR
AutoCAD SHX Text
AutoCAD SHX Text A1.0
AutoCAD SHX Text %%uNEW WORK WALL SECTION
AutoCAD SHX Text 3/4" = 1'-0"
AutoCAD SHX Text
PROVIDE EXTRA FRAME AT HEAD IF REQ'D TO FIT EX. OPENING
AutoCAD SHX Text
PLAN LEGEND: EXISTING 1 HOUR WALL EXISTING 2 HOUR WALL
AutoCAD SHX Text
NOTE: HATCH INDICATES AREA OF WORK
AutoCAD SHX Text PROPOSED 1 HOUR WALL (WALL TYPES 1 & 1A) PROPOSED 2 HOUR WALL (WALL TYPES 2 & 2A)
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
NEW WORK R. CEILING PLAN
AutoCAD SHX Text
SCALE 1/8" = 1'-0"
AutoCAD SHX Text REMOVE EXISTING CEILING GRID / TILE & GYP. BULKHEADS @ LOBBY / CORRIDOR WALL AS REQ'D TO INSTALL NEW WORK. SEE NEW WORK PLAN. PATCH / REPAIR AS REQ'D.
AutoCAD SHX Text REMOVE EXISTING GYP. BULKHEADS AS REQ'D TO INSTALL NEW SHUTTER. SEE NEW WORK PLAN. PATCH / REPAIR AS REQ'D.
AutoCAD SHX Text REMOVE EXISTING GYP. BULKHEADS / CEILING FINISHES / LIGHTING COMPLETE IN ROOMS 106, 107, & 108. PATCH / REPAIR ADJACENT WALL FINISHES AS REQ'D.
INSTALL NEW ACT TO MATCH EXISTING AT AREA WHERE EXISTING OFFICE WAS REMOVED.
A1.2
CONSTRUCTION MANAGEMENT
DEVELOPMENT
1104 S. MITCHELL ST.
CADILLAC, MICHIGAN 49601
(231) 779-4002
(231) 779-4022 FAX
ARCHITECT OF RECORD:
DRAWN BY:
PROJECT NUMBER:
SHEET NUMBER:
DATE ISSUED:
THE
DESIGN GROUP
D. DeKryger
K. Taylor
April 23, 2026 Bidding & Construction
25123B
Pr op os ed
R en ov at io n fo r:
W ex fo rd
-M is sa uk ee
IS
D Sp ec ia l S er vi ce s Bu ild in g
E
. 1 3t h St re et
Ca di lla c, M I 4
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
18" MIN.
AutoCAD SHX Text
(a) FRONT APPROACH, PULL SIDEFRONT APPROACH, PULL SIDE
AutoCAD SHX Text
(b) FRONT APPROACH, PUSH SIDE FRONT APPROACH, PUSH SIDE (NEW BUILDINGS) * IF BOTH CLOSER AND LATCH ARE PROVIDED
AutoCAD SHX Text
12" MIN.*
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
%%UMANEUVERING CLEARANCE AT DOORS
AutoCAD SHX Text
\" = 1'-0" ANSI 117.1 2017/FIG. 404.2.3.2
AutoCAD SHX Text
(c) FRONT APPROACH, PUSH SIDE FRONT APPROACH, PUSH SIDE (EXISTING BUILDINGS, FOOTNOTE 5) * IF BOTH CLOSER AND LATCH ARE PROVIDED
AutoCAD SHX Text
12" MIN.*
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
36" MIN.
AutoCAD SHX Text
(d) HINGE APPROACH, PULL SIDEHINGE APPROACH, PULL SIDE
AutoCAD SHX Text
54" MIN.
AutoCAD SHX Text
42" MIN.
AutoCAD SHX Text
(e) HINGE APPROACH, PULL SIDEHINGE APPROACH, PULL SIDE
AutoCAD SHX Text
(f) HINGE APPROACH, PUSH SIDE HINGE APPROACH, PUSH SIDE * IF BOTH CLOSER AND LATCH ARE PROVIDED ** 48 MIN. IF BOTH CLOSER AND LATCH ARE PROVIDED
AutoCAD SHX Text
12" MIN.*
AutoCAD SHX Text
22" MIN.
AutoCAD SHX Text
42" MIN.**
AutoCAD SHX Text
48" MIN.
AutoCAD SHX Text
52" MIN.
AutoCAD SHX Text
48" MIN.*
AutoCAD SHX Text
24" MIN.
AutoCAD SHX Text
(g) LATCH APPROACH, PULL SIDE LATCH APPROACH, PULL SIDE * 54 MIN. IF CLOSER IS PROVIDED
AutoCAD SHX Text
42" MIN.**
AutoCAD SHX Text
(h) LATCH APPROACH, PUSH SIDE LATCH APPROACH, PUSH SIDE * 48 MIN. IF CLOSER IS PROVIDED
AutoCAD SHX Text
24" MIN.
AutoCAD SHX Text
%%UTURNING & CLEAR FLOOR SPACES
AutoCAD SHX Text
SECTIONS 304 & 305
AutoCAD SHX Text
304 . 3 . 1 - CIRCULAR SPACE
AutoCAD SHX Text
304 . 3 . 3 - T-SHAPED SPACE
AutoCAD SHX Text
305 . 3 - CLEAR FLOOR SPACE
AutoCAD SHX Text
67" MIN.
AutoCAD SHX Text
64" MIN.
AutoCAD SHX Text
40" MIN.
AutoCAD SHX Text
20" MIN.
AutoCAD SHX Text
30" MIN.
AutoCAD SHX Text
52" MIN.
AutoCAD SHX Text 10"
AutoCAD SHX Text
OVERLAP OF KNEE & TOE CLEARANCE
AutoCAD SHX Text
12" MIN.
AutoCAD SHX Text
40" MIN.
AutoCAD SHX Text
12" MIN.
AutoCAD SHX Text
OVERLAP OF KNEE & TOE CLEARANCE
AutoCAD SHX Text
OVERLAP OF KNEE & TOE CLEARANCE
AutoCAD SHX Text
304 . 3 . 2 - T-SHAPED SPACE
AutoCAD SHX Text
68" MIN.
AutoCAD SHX Text
36" MIN.
AutoCAD SHX Text
24" MIN.
AutoCAD SHX Text 8"
AutoCAD SHX Text
16" MIN.
AutoCAD SHX Text
36" MIN.
AutoCAD SHX Text 8"
AutoCAD SHX Text
16" MIN.
AutoCAD SHX Text 8"
AutoCAD SHX Text 8"
AutoCAD SHX Text
OVERLAP OF KNEE & TOE CLEARANCE
AutoCAD SHX Text
OVERLAP OF KNEE & TOE CLEARANCE
AutoCAD SHX Text 18"
AutoCAD SHX Text
MIN.
AutoCAD SHX Text 39" - 41"
AutoCAD SHX Text
3'-0" MIN.
AutoCAD SHX Text 16"-18"
AutoCAD SHX Text 33" - 36"
AutoCAD SHX Text 24"
AutoCAD SHX…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .