This document is a Statement of Work (SOW) for repairs to two fan motors on the U.S. Coast Guard Cutter WILLOW. The SOW describes the problems with the supply and exhaust fan motors, which are both seized, and provides detailed technical specifications for the fans. The work to be performed includes disassembling and inspecting the fan assemblies, replacing degraded and broken parts, inspecting and checking the stator windings, and prepping, priming, and painting the required parts. The SOW references relevant technical specifications and standards that must be followed. The related federal contract opportunity is solicitation number 70Z08524P06889 for the USCGC WILLOW fan repairs, issued by the Department of Homeland Security U.S. Coast Guard.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work for USCGC WILLOW Qty 2 Fan Repairs
Points of Contact:
CWO Archibald Newland
USCGC WILLOW (WLB 202)
1050 Register St.
North Charleston, SC 29405 Work – 843-529-0158 Email: Archibald.Newland@uscg.mil Product Line Support:
LTJG Christopher Lansing 443-764-4921
Christopher.g.lansing@uscg.mil Description of Problem When the ship lost power, the crew found that both supply and exhaust fan motors would not energize. The ship continued to troubleshoot the issue and found that both motors are seized.
Fan Info #1
Buffalo Forge
Fan, Exhaust, Centrifugal, 750 CFM
.5 HP, 3600 RPM
440V 85 A Reliance Motor
Fan Info #2
Buffalo Forge Fan, Supply, Centrifugal, .75 HP, 3450 RPM
Fan housing Length 20in, ID 14in Work to be performed:
Disassemble and inspect fan assembly providing pictures and details of parts needing complete replacement via condition found report. Replace/renew all degraded and broken parts. Inspect and check stator windings, replace as necessary IAW SFLC STD Spec 3020. Prep, Prime, and Paint required parts IAW SFLC STD Spec 6310. Provide post operational tests and readings and ship back to cutter.
Technical references:
SFLC STD Spec 0000
SFLC STD SPEC 6310
SFLC STD SPEC 3020