LIST OF SECURITY EQUIPMENT FOR DESERT WEST CBMH
SALINE CHARACTERISTICS
· HID Proximity Card Reader (x8)
· 24VDC Magnetic Locks (x8)
· Request to exit push buttons (x8)
· Request to exit motion sensors (x8)
· CAT 6 plenum cable (x3 spools)
· Access Control System compatible with DSX 1048pkg (x1)
· Access Control System compatible with DSX DSX 1042pkg (x1)
· Glass Break Detector (x3)
· Motion Sensor/Passive Infrared Sensor (x8)
· Panic Alarm Buttons (x6)
· Intrusion Detection System hardware / Built-in Communication Dialer (x1)
· Door Contacts (x15)
· Component rack (hold up to 5 components) (x2)
· 3MB Fixed Cameras (x22)
· Public Address module amplifier/mixer (x1)
· Public Address ceiling speakers (x12)
· Electric Door Strike (x1)
· Intercom System (x1)
UFC 4-510-01 1 May 2016 Change 1, May 2016
14-4.2 Systems Considerations.
ESS is an integrated electronic system that encompasses interior and exterior Intrusion Detection Systems (IDS), duress alarms, Access Control Systems (ACS), infant protection alarm, staff assistance alarm, and Closed Circuit Television (CCTV) systems for assessment of alarm conditions shall be provided for facilities when required by the Using Military Department. Multiple ESS may be integrated to provide an overall facility security system. A staff identification card system with multiple levels of access control may be provided. Package inspection devices may also be considered for mail rooms.
Design ESS in accordance with UFC 4-021-02.
14-4.2.1 Stand-Alone Clinic Facilities Projects.
For stand-alone clinic facilities projects, provide an ESS with the capability for intrusion detection and door access control. Also, provide a video surveillance capability as required by project-specific criteria.
Baseline Intrusion Detection System (IDS) Requirements.
• Must be protected by an IDS when not continuously manned or under constant surveillance.
• All perimeter doors and man-passable openings into the storage area must be protected by High Security Switch (HSS) and a motion detection sensor.
• Duress alarm at all issue ports.
• Keypad at entrance and for all separated (unit-based) interior storage areas that require an independent IDS capability.
• Perimeter emergency exit doors must be secured, alarmed, and monitored 24 hours per day.
• IDS must be installed in accordance with UL 681 and consist of: • Level 2 high security switches (HSS) that meet UL 634, and/or other government approved sensors.
• Motion detection sensors UL 639 listed.
• Premise Control Units (PCUs) should be located within the protected area.
Tamper Protection.
• All IDS systems, including any access control system connected must be equipped with tamper detection devices that must be monitored continuously whether the system is in the access or secure mode of operation. Upon detection, an alarm (not fault) condition must be transmitted to the PCU or monitoring station.
• System associated cabling that extends beyond the protected area perimeter must be installed in conduit and must employ electronic line supervision. Electronic line supervision will entail a polling or multiplexing system or equivalent. If line supervision is unavailable, two independent means of alarm signal transmission to the monitoring location must be provided.
• All system sensors must be located within the protected area.
• Cabling between all sensors and the PCU must be dedicated to the system, contained within the protected area.
HID Proximity Card Reader (x8)
| Dimensions |
| 12.0˝ x 12.0˝ x 1.0˝ (30.5 cm x 30.5 cm x 2.5 cm) |
| Read Range |
| Up to 24.0˝ (61.0 cm) |
| Mounting |
| Mount on non-metallic surfaces for optimal read range performance. |
| Power Supply |
| 12 VDC or 24 VDC |
| Current Requirements |
| 200/700 mA @ 12 VDC 260 mA/1.2 A @ 24 VDC |
| Termination |
| Terminal Strip |
| Output Formats |
| Wiegand, Clock-and Data, RS-232, RS-422 and RS-485 |
| Indoor/Outdoor |
| IP55 Certified |
24VDC Magnetic Locks (x8)
| Housing Dimensions |
| 1-5/8" D × 2-7/8" W × 21" L |
(41.3 mm × 73.0 mm × 533.4 mm) (including 1/4" (6 mm) mounting bracket)
| Mounting |
| Adjustable keyhole mounting |
| Composition |
| 628 brushed anodized aluminum lock body |
Armature Plate Dimensions Standard: 5/8" D × 2-3/8" W × 7-7/16" L* (15.9 mm × 60.3 mm × 188.9 mm)
| Voltage |
| Field selectable 12/24 VDC |
Tolerance ±10%
Power/Current Requirements Max 0.28 A at 12 VDC (each lock) Max 0.28 A at 24 VDC (each lock)
| Holding Force |
| Two-point locking |
(1500 lb each point)
| Output Relays |
| BA (with LED)—SPDT 1.25 A @ 24 VDC |
DP—SPDT 0.20 A @ 12 VDC and 0.12 A @ 24 VDC
| Wiring Requirements |
| 2 or 4 wires—power input; up to 4 or 8 wires output |
| Adjustable Time Delay |
| 0–110 seconds |
| Operating Temperature |
| 14 to 140° F (–10 to 60° C) |
| Bond Alert Sensor (BA) |
| Electronic field presence sensor for remote and local LED indication of reduced holding force caused by materials between magnet and plate, and unlocked device due to current loss. |
| Door Position Sensor (DP) |
| Ceramic magnet-reed type sensor for remote indication of door status (opened or closed, independent of local power); magnet embedded in armature for tamper resistance; reed switch inside electronic housing cavity for easy access. |
| LED Indicator |
| Include with BA options, the LED gives a local indication of lock status: red—unsecured; green—secured. |
| Switch Standard |
| UL 634, Level 2 |
| Low-Voltage Detection |
| Low voltage dramatically reduces electromagnetic lock holding force. This detection feature signals the BA relay/LED to activate (alarm) when voltage drops below 10.3 VDC (12 V input) or 20.5 VDC (24 V input). |
Request to exit push buttons (x8)
| Button Size |
| approx. 1-1/2" x 1-1/2" |
| Circuit State |
| normally closed |
| Faceplate Size |
| approx. 2-3/4" x 4-1/2" |
| Finish |
| us32d satin stainless steel |
| Mounting |
| single-gang electrical box |
| Category |
| electric pushbutton switch |
| Switch Type |
| single-pole, single throw |
Request to exit motion sensors (x8)
| Operating temperature |
| -29 - 49 °C |
| Mounting type |
| Ceiling/wall |
| Dimensions (WxDxH) |
| 38 x 159 x 38 mm |
| Operating frequency |
| 26 - 1000 |
CAT 6 CCTV cable (x3 spool)
| Type |
| shielded plenum solid |
Access Control System Controller (x2)
| General |
| Scalable Architecture 2-8 doors |
Individual Intelligence
UL 294 / UL 1076
260+ Card and Keypad Formats FIPS/TWIC Card Compatibility Real Time Processing and Communications Integrated Power Supply and Distribution
| Processor |
| AM186 20Mhz or better |
| RAM/ROM Memory |
| Flash ROM 512K Standard RAM 512K |
| Communication Ports |
| TCP/IP Communications |
1 Enclosure 1 (CDM) Communication Distribution Module 4 Intelligent Controllers 8 Reader Ports 32 Inputs 16 Outputs 32-1K ohm EOL resistors 1 Lock & Key Wire Ties Tamper Switch (must) 1 External Power Indicator Power Distribution Panel
| Power Requirements |
| 13.5 VDC @ 300ma & 13.5 VDC @ 150ma for Total Maximum Current 13.5 VDC @ 6.0A |
| Output Voltage |
| Panel outputs provide a regulated, fused, DC voltage. |
9-13.5VDC - 12VDC nominal - 1A Fused 9-13.5VDC-12VDC nominal-1.5A Fused 5VDC - .5A Fused All Outputs are Class 2, Power Limited
16 Inputs are used for standard point monitoring.
16 Inputs are used for door position and exit request monitoring.
All Inputs support two, three, and four state monitoring with five programmable circuit types.
Relay Output Ratings 5 AMP - 30VDC Open Collector Outputs 8 - negative 100ma LED Outputs 24 - 3 per reader port - negative 100ma Pre-Alarm Outputs 8 - 1 per door - negative 100ma
| Access Controlled Entry Points |
| Card Reader or Keypad 8 |
Card and Reader Formats 260+ including FIPS/TWIC Any combination of card readers, keypads, or card and keypad controlled entry points may be used.
| Equipment Size |
| 11" W x 4.5" H x 1.5" D |
11" W x 4.5" H x 1.5" D
| Equipment Weight |
| 1.0 lb. or 1.2 lb. each |
| Enclosure Type |
| Nema Type 1 equivalent enclosure with lift-off hinged door, lock/key, and tamper switch. |
| Enclosure Size |
| Cabinet 15.5" W x 22.5" H x 6" D |
| Enclosure Weight |
| Cabinet 19.2 lb. |
| Finish |
| Black Powder Coat with White Silkscreen on Enclosure |
and Black Enamel
| Conduit Knockouts |
| Concentric knockouts in Top, Bottom, and Sides. |
Knockouts must accommodate 1/2, 3/4, 1, 1 3/4 inch conduit.
| Temperature |
| Operating 32 to 131 F/Storage -35 to 150 F |
| Humidity |
| Operating 0 to 95%, relative |
Glass Break Detector/Motion Sensor (x3)
| Type |
| Vibration & Sound (non-wireless). Cannot use Pulse Count Filtering |
Frequency Ranges
Detection Range Infrasonic (16 Hz to 0.0001 Hz) Audio Band (20 Hz to 20 kHz) <25 Sq Ft to >200 Sq Ft
| Adhesive Type |
| Must withstand long Exposures to sunlight, heat, cold and condensation. |
Motion Sensor (PIR) (x8)
| Detection Range (UL/CUL approved) |
| coverage diameter of 26 ft. at 12 ft. mounting height and |
UL 639 listed
| Optics |
| Fresnel lens or better |
| Current Consumption |
| 8.7 mA |
| Alarm Relay |
| <24 VDC, 50mA, NC |
| Tamper Relay |
| <24 VDC, 50mA, NC |
| Target Speed Range |
| 1 ft./s to 10 ft./s (30cm/s to 3m/s) |
| Dimensions (diameter x H) |
| 4.57" diameter x 1.30" H (116 x 33 mm) |
| Ambient Conditions |
| 14ºF to 130ºF (-10 to +55ºC) |
| Relative Humidity |
| Max. 95% |
Panic Alarm Buttons (x6)
| Type |
| The alarm occurs when the actuating lever is moved 20° to 45° past the fully closed position (approximately 1" from the fully closed position). Capable of latching and an LED on the unit flashes and latches when the lever is opened. It can be reset only at the alarm panel. The actuating lever, housing and cover plate are made of ABS fire-retardant plastic. Dimensions of the unit should be around 1.77" W x 2.90" L x 0.76" H (4.50 cm W x 7.37 cm L x 1.93 cm H). The unit has to have at minimum 12 feet of jacket lead. The device should be able to mount to a surface with head screws. |
| Nominal Voltage |
| 12 V DC @ 6 mA |
| Operational Voltage |
| 7 V DC to 15 V DC |
| Temperature Range |
| 0° to 110°F (-17.8°C to 43.3°C) |
| Housing Material |
| ABS plastic |
Intrusion Detection System/Built-in Communication Dialer/Panel with Key Pad (x1)
| Detection Zones |
| At least 10 or more zones on the board and can be expandable to up to 16 or more hardwired zones to accommodate duress buttons and sensors. |
| Tamper Protection |
| The systems, including any access control system connected must be equipped with tamper detection devices that must be monitored continuously whether the system is in the access or secure mode of operation. Upon detection, an alarm (not fault) condition must be transmitted to the PCU or monitoring station. |
| Other specifications |
| 2 PGM outputs: expandable to 14 (PC5204, PC5208). Can Connect up to 2 supervised keypads. Capable of template programming and up two 2 partitions. Have at up to 500-event buffer and up to 48 user codes programming. |
| Battery Backup |
| Must have up to 8 hour battery backup. |
Door Contacts (x15)
| General |
| Must be a miniature, low-profile design |
Stainless steel armored cable for added security and reliability Wide operating gap for overhead doors Model available for high-security applications Fully sealed switch Mounting for overhead or windows
| Voltage |
| The voltage can be from 30 VAC/VDC max. and up to 100 VAC/VDC max. |
| Current |
| 0.25 A max. and up to 0.5 A max. |
| Loop Type |
| Can be either Open or Closed |
| Electrical configuration |
| SPDT (2207AD: DPDT) or can be Normally open. |
| Gap distance |
| 3/4 to 2-1/2 in. but no more that up to 3 in. |
| Dimensions |
| Can be one of the following dimensions 3.50 x 1.50 x 1.50 in. (89 x 38 x 38 mm), 3.50 x 1.50 x 2.125 mm (89 x 38 x 54 mm), 3.50 x 1.50 x 1.0 in. (89 x 38 x 25 mm) |
| Housing |
| At a minimum must be Bar Stock aluminum or stronger |
| Regulatory Requirements |
| UL 634, Level 1 |
3MPX Fixed Indoor/Outdoor Dome Cameras (x22)
| Features |
| 130dB Wide Dynamic Range (WDR) |
Advanced Low-Light Performance, 0.05 lux Anti-Bloom Technology 3D Noise Filtering Enhanced Tone Mapping Up to 3 Megapixel (MPx) Resolution Up to 60 Frames per Second (fps) Autofocus Varifocal 3 ~ 9 mm or 9 ~ 22 mm Lens Power over Ethernet (PoE), IEEE 802.3af, 24 VAC, 12 VDC Smart Compression Technology Built-in Analytics Suite Adaptive IR Illumination up to 30 Meters (Option) Up to 128 GB Edge Storage with SD Card Compatible with Pelco and Third-Party Video Systems ONVIF Profile S, Profile G, and Profile Q Conformant
Public Address module amplifier/mixer for up to 12 speakers (x1)
| Features |
| PA System should have the following… |
4 separate amplifier channel outputs, each channel RMS 60W/120W with a capability of connecting up to 12 speakers Up to 5 AUX inputs, 3 balanced Mic input with phantom power supply 4 remote paging stations, support cascaded linkage Each AUX and Mic input with volume and Bass & Treble control Support TEL input, built-in chime and one touch emergency alarm 70V/100V & 4-16 Ω flexible speaker output 1 emergency channel
Public Address ceiling speakers (x12)
| Features |
| Ceiling loudspeaker, 60W – 80W, 8 inch two-way |
| Frequency Range (-10 dB) |
| 40 Hz - 20 kHz |
| HF Power Handling |
| 200 W Program, 100 W Pink Noise |
| Sensitivity (SPL 1 W/1 m) |
| 88 dB |
| Max Calculated SPL |
| 108 dB Avg, 114 dB Peak |
| LF Transducer |
| 200 mm (8 in) |
| HF Transducer |
| 35 mm Compression Driver |
| Transformer Taps |
| 70V: 60W, 30W, 15W, 7.5W, 8 ohm |
100V: 60W, 30W, 15W, 8 ohm
| Connectors |
| Removable locking 4-Pin (Phoenix) |
2.5 mm (12 AWG) max wire size
| Enclosure |
| ABS Plastic (UL94V-0) Baffle, steel |
back can
| Net Weight |
| Between 3-5 pounds |
Electric Door Strike (x1)
| 12/24 VDC Operating voltage |
| Non-handed, for use with left or right hinged doors |
| Non-polarized connection |
| Surface-mount installation |
| Horizontal adjustment |
| Metal or wood frame installation |
| 1,500-lb Static strength |
| 250,000 cycles (1-million cycles factory tested) |
| 3/4" (19mm) thick metal housing |
| Works with standard rim-type exit devices including SECO-LARM SD-962AR-36A, SD-962AR-36G, and SD-962AR-36M |
| Accommodates up to 3/4" Pullman latch |
| Plug-in wire connection |
Current draw: 540mA@12VDC
Dynamic strength 70 ft.lbs.
Field-programmable for fail-safe or fail-secure operation
Intercom System (x1)
Compatible with 2-station systems
C-123L/A
C-123LW (add a third master)
One DAK-2S is included in C-123LW set)
LEM-1, LEM-3 (1 per channel on LEM-3)