Water Testing SOW.pdf

PDF 67 KB Posted

Attached to
USCG Base San Juan Stormwater Discharge Monitoring
Solicitation number
31170PRSDM
Issued by

About this file

This is a Statement of Work for stormwater discharge monitoring services at USCG Base San Juan in Puerto Rico.

The Contractor must provide comprehensive environmental water testing and laboratory analysis services for three designated stormwater outfalls (004, 006, and 007) under NPDES permit PRR05J005. Required monitoring parameters include indicator monitoring for pH, Total Suspended Solids (TSS), and Chemical Oxygen Demand (COD), as well as benchmark monitoring for Total Recoverable Aluminum (1,100 µg/L), Total Recoverable Lead—Saltwater (210 µg/L), and Total Recoverable Zinc—Saltwater (90 µg/L). The Contractor must comply with EPA NPDES Program requirements, Clean Water Act standards per 40 CFR Part 136, and USCG Environmental Standards per COMDTINST M5100.47 series.

Performance of services runs from September 1, 2026, through August 31, 2027, at USCG Base San Juan, #5 Calle La Puntilla, San Juan, Puerto Rico 00901. All Contractor personnel must meet security access requirements including presentation of valid REAL ID-compliant identification, submission of technician rosters to Base Security, vehicle inspections, and potential escort requirements. Primary Government Points of Contact are Abdiel Garraton (787-306-1337) and Dagmar Torres (571-608-2157).

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

USCG Base San Juan Stormwater Discharge Monitoring

1.0 Background

To maintain environmental compliance and operational readiness, USCG Base San Juan requires professional stormwater discharge monitoring. This Statement of Work outlines the requirements for water testing services under the facility's National Pollutant Discharge Elimination System (NPDES) permit (NPDES ID: PRR05J005).

2.0 Scope of Work

The Contractor shall provide comprehensive environmental water testing and laboratory analysis for designated stormwater outfalls at USCG Base San Juan.

2.1 Designated Testing Locations

The Contractor is required to draw samples and monitor the following specific outfalls on the installation:

Outfall Designation Description

Outfall 004 Stormwater Discharge Monitoring Point

Outfall 006 Stormwater Discharge Monitoring Point

Outfall 007 Stormwater Discharge Monitoring Point

2.2 Required Monitoring Parameters

The Contractor shall perform laboratory analysis on all drawn samples to test for the following required parameters:

Parameter Category Specific Testing Parameter Benchmark / Target

Concentration

Indicator Monitoring pH N/A

Indicator Monitoring Total Suspended Solids (TSS) N/A

Indicator Monitoring Chemical Oxygen Demand (COD) N/A

Benchmark Monitoring Total Recoverable Aluminum 1,100 µg/L

Benchmark Monitoring Total Recoverable Lead (Saltwater) 210 µg/L

Benchmark Monitoring Total Recoverable Zinc (Saltwater) 90 µg/L

3.0 Regulatory & Legal Compliance

To ensure all environmental and laboratory standards are met, the Contractor must comply with the most current editions of the following regulations:

Regulatory Framework Compliance Requirement

EPA NPDES Program Strict adherence to the testing, analysis, and reporting requirements mandated by the Environmental Protection Agency under NPDES ID: PRR05J005.

Clean Water Act (CWA) Compliance with all federal standards for stormwater discharge and testing methodologies as outlined in 40 CFR Part 136.

USCG Environmental Adherence to the Coast Guard Safety and Environmental

Standards Health Manual (COMDTINST M5100.47 series) regarding environmental stewardship on military installations.

4.0 Security Access Requirements

As USCG Base San Juan is a restricted military installation, vendor personnel must comply with all base security and access protocols during sample collection:

Security Protocol Requirement Description

Personnel Identification All Contractor personnel must possess and present a valid, REAL ID-compliant state driver's license, passport, or approved DBIDS credential to enter the installation.

Vehicle Inspections All Contractor service vehicles and equipment are subject to random anti-terrorism measures and full inspections by USCG Security Forces upon entry and exit.

Access Rosters The Contractor must submit a complete roster of all assigned technicians to the Base Security Office prior to scheduled sampling visits.

Escort Requirements If Contractor personnel do not possess independent base access credentials, they must be escorted by authorized USCG personnel while in restricted areas.

5.0 Location & Point of Contact

Government Facility Location:

USCG Base San Juan

#5 Calle La Puntilla

San Juan, Puerto Rico 00901

USCG Points of Contact:

• Abdiel Garraton: 787-306-1337 |Abdiel.J.GARRATONHERNANDEZ@uscg.mil

• Dagmar Torres: (571) 608-2157 | dagmar.torres@uscg.mil

6.0 Dates of Performance

September 1, 2026- August 31th, 2027 mailto:|Abdiel.J.GARRATONHERNANDEZ@uscg.mil mailto:dagmar.torres@uscg.mil

File details come from the government source that posted it. Updated .