ATTACHMENT 5: Regional Health Command Pacific (Japan) Scope of Accreditation
ENVIRONMENTAL CHEMISTRY
| MATRIX |
| Specific TEST |
| SPECIFICATION or STANDARD METHOD |
| Key Equipment or Technology Used |
| Potable Water / Bottled Water 2 |
| Metals |
| EPA 200.8 |
SOP 115
ICP-MS
| Potable Water / Bottled Water 2 |
| Metals |
| EPA 200.7 |
SOP 103
ICP-OES
Potable Water / Non-potable Water / Bottled Water 2
| Anions (chloride, fluoride, sulfate, nitrite, nitrate) |
| EPA 300.0 |
SOP 125
IC
| Potable Water |
| Minerals (Calcium Hardness) |
| SM 2340B |
SOP 143
| Potable Water / Bottled Water 2 |
| Nitrite |
| SM 4500-NO2-B |
SOP 122
Spectrophotometer
Potable Water / Non-potable Water / Bottled Water 2
| Cyanide |
| EPA 335.3 |
SOP 132
Cyanide Analyzer
| Potable Water / Bottled Water 2 |
| Alkalinity |
| SM 2320B |
SOP 108
Titration
| Potable Water |
| Langelier Index |
| ASTM D3739-06 |
SOP 133
| Potable Water / Bottled Water 2 |
| Endothall |
| EPA 548.1 |
SOP 139
GC-FID
| Potable Water / Bottled Water 2 |
| Diquat |
| EPA 549.2 |
SOP 131
HPLC with VWD
| Potable Water / Bottled Water 2 |
| Glyphosate |
| EPA 547 |
SOP 130
HPLC with VWD
| Potable Water / Bottled Water 2 |
| Haloacetic Acids |
| EPA 552.3 |
SOP 141
GC-ECD
Potable Water / Non-potable Water / Bottled Water 2
| VOCs |
| EPA 524.2 |
SOP 112
GC-MS
ENVIRONMENTAL MICROBIOLOGY
| MATRIX |
| Specific TEST |
| SPECIFICATION or STANDARD METHOD |
| Key Equipment or Technology Used |
| Potable Water / Bottled Water 2 |
| E. coli / |
Total coliform
SM 9223B
PDL SOP 713
Colilert
| Potable Water / Bottled Water 2 |
| E. coli / |
Total coliform
HACH 10029
PDL SOP 704
m-Coliblue 24
Nucleic Acid Extracts 2
Dengue Japanese Encephalitis Malaria West Nile Leptospirosis
PDL
SOP 706 / 709
Real Time PCR system Thermocycler
Notes:
1. * = As Applicable
2. Bottled water and nucleic acid extract analyses are NOT part of the approved TNI scope of accreditation.