W91WFU-18-Q-0025_Q&A_11Sept18.pdf
PDF 104 KB Posted
- Attached to
- RF Tent & Enclosures
- Solicitation number
- W91WFU18Q0025
About this file
USG Responses to questions received on this RFQ (Round 1).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W91WFU-18-Q-0025_CONFORMED_RFQ_thru_Amdt._0002.pdf | ||
| W91WFU-18-Q-0025_Amdt._0002.pdf | ||
| Exhibit_1_Salient_Characteristics_11Sept18.xlsx | XLSX spreadsheet | |
| W91WFU-18-Q-0025_Amdt_0001.pdf | ||
| W91WFU-18-Q-0025_CONFORMED_thru_Amdt_0001.pdf | ||
| Exhibit_1_Salient_Characteristics_10Sept18.xlsx | XLSX spreadsheet | |
| RFQ_W9WFU-18-Q-0025_7Sept18.pdf | ||
| Exhibit_1_Salient_Characteristics_30Aug18.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offeror Questions & USG Responses in support of Solicitation W91WFU-18-Q-0025 Round 1
11 September 2018
1. Our solution would not match the RFQ exactly, because our product has a metal frame that the tent attaches to. Functionally it is not a disadvantage, but would an offer with a metal frame be considered since it doesn’t match the characteristics in Exhibit 1 exactly?
Reference: Exhibit 1 – Salient Characteristics
USG Response – The requirement is for an inflatable frame. As a result of this question, Exhibit 1 – Salient Characteristics has been revised.
2. If the Metal Frame would be considered -- Exhibit 1 lists air pumps within item 1. Are these for the air frame, and if so, I would propose leaving those out of our proposal if that is acceptable.
Reference: Exhibit 1 – Salient Characteristics, Item #1
USG Response – A metal frame will not be considered. REF USG Response to Question 1.
3. If the Metal Frame would be considered -- Exhibit 1 lists an “entrance assembly using conductive Velcro”. We would propose our patented magnetic enclosure, which seals easier, stronger, and lasts longer than Velcro. Would this be an acceptable alternative?
Reference: Exhibit 1 – Salient Characteristics, Item #1
USG Response – A metal frame will not be considered. REF USG Response to Question 1.
4. Exhibit 1 Item 4 is a Shield Table Top Enclosure. What are the required dimensions of this item?
Reference: Exhibit 1 – Salient Characteristics, Item #4
USG Response – The required dimensions of this item are 2’x3’3’. As a result of this question, Exhibit 1 – Salient Characteristics has been revised.
***END OF Q&A Round 1***