Question:
would like to confirm if the quantity in feet is accurate specially for the first two items; QTY 2 of 2 feet?, QTY 5 of 1 foot?
(Quantity 2) 2’ Neoprene (N) (Quantity 4) 1’ N (Quantity 2) 150’ N (Quantity 4) 10’ N (Quantity 2) 50’ N (Quantity 2) 130’ Armored (Ar) (Quantity 2) 20’ Ar (Quantity 2) 100’ N
Answer:
Yes. (QTY 2 of 2 feet)
No. (QTY 5 of 1 foot?) Correct: QTY 4 of 1 foot
Question:
Manufacturer states that the coaxial cable itself has an operating temperature range of ‐65ºC to +200ºC.
The 3.5mm straight male connectors compatible to PN# 2301 have an operating temperature range of ‐ 60ºC to +100ºC. So, the assembly will be limited to an operating temperature range of ‐60ºC to +100ºC.
Is this acceptable? Please confirm.
Answer:
Yes, the temperature limitation is acceptable.