Questions and Answers.pdf

PDF 99 KB Posted

Attached to
Cables
Solicitation number
W91RUS23R0002
Issued by

View the file

Other files

File Type Posted
W91RUS23R0002.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Question:

would like to confirm if the quantity in feet is accurate specially for the first two items; QTY 2 of 2 feet?, QTY 5 of 1 foot?

(Quantity 2) 2’ Neoprene (N) (Quantity 4) 1’ N (Quantity 2) 150’ N (Quantity 4) 10’ N (Quantity 2) 50’ N (Quantity 2) 130’ Armored (Ar) (Quantity 2) 20’ Ar (Quantity 2) 100’ N

Answer:

Yes. (QTY 2 of 2 feet)

No. (QTY 5 of 1 foot?) Correct: QTY 4 of 1 foot

Question:

Manufacturer states that the coaxial cable itself has an operating temperature range of ‐65ºC to +200ºC.

The 3.5mm straight male connectors compatible to PN# 2301 have an operating temperature range of ‐ 60ºC to +100ºC. So, the assembly will be limited to an operating temperature range of ‐60ºC to +100ºC.

Is this acceptable? Please confirm.

Answer:

Yes, the temperature limitation is acceptable.

File details come from the government source that posted it. Updated .