Text version

Sheet1

6000 Watt Power Amplifier 80 to 1000 MHz
ConditionNew
Frequency Range80 - 1000 MHz
Output power at the output connector6000 watts minimum
Compliant?NotesSpecification Requirement
The amplifier will have:
RF & hardware protection including
high VSWR
over-current
voltage protection
redendant thermal and airflow sensors to prevent amplifier from overheating.
The amplifier will be protected from RF input overdrive when the RF input level is increased above max input.
The RF amplifier stages will be protected when an over-temperature condition occurs due to cooling blockage or fan failure.
The amplifier will have a front panel digital display that shows forward and reflected output
Plus extensive system status and self-diagnostic information. Status indicators include:
power on
warm-up
standby
operate
faults
excess reflected power warning
remote.
The amplifier operating parameters are simultaneously available in the amplifier front panel display as well as over the remote bus.
Selection switches or keystroke allow you to switch the amplifier to the desired mode of operation for local control if the unit is not being operated remotely.
Amplifier will include a built-in IEE-488 (GPIB) interface, RS-232 and Ethernet interface:
Amplifier features will include:
VSWR protection
gain control
internal automatic level control
forward and reflected RF output sample ports on front panel on front panel
plus monitoring of:
TWT helix current
cathode voltage
collector voltage
heater current
heater voltage
baseplate temperature
cabinet temperature.
Amplifier will be modular in design for easy access and repair of the power supply and RF components.
Specification Requirement:
Frequency Range:80 - 1000 MHz
Input for rated output:1.0 milliwatt maximum (0 dBm)
Rated Power @ Output Connector:6000 Watts minimum
Power output @ 1 dB compression4500 wats minimum
Flatness:±2 dB typical
Gain:67.8 dB minimum
Gain Adjust:Continuous range: 25 dB minimum
Input Impedance50 ohms, VSWR 1.5:1 maximum
Output Impedance50 ohms, VSWR
VSWR Reflected Power ProtectionWill automatically reduce the input drive and fold back the output power when the average reflected power exceed 3.0:1. The unit opeates without damage or oscillation inot any magnitude of phase or load impedance.
Mismatch Tollerance:100% of rated power without foldback, up to 6.0:1. Will operate without damage or oscillation with any magnitude and phase of source and load impedance
Moduation Capability:Will faithfully reproduce AM, FM, or pulse modulation appearing on the input signal.
Noise Figure:6.2 dB or better.
Harmonic Distortion:-20 dBc
Spurious Outputs:-65 dBc
Operating Temperature:32 to 122 degrees F (0 to 50 degrees C)
Non-operating Temperature:-40 to 158 degrees F (-40 to 70 degrees C)
Altitude:0 to 6000 feet operating
Primary Power:208 VAC, WYE (5 wire), 50/60 Hz, 3-phase
Connectors:
RF input: Type N female, front panel
Forward and reflected power sample ports, Type N female, front panel
RF output: Type 1-5/8 EIA female, rear panel
Remote computer interfaces
GPIB IEEE-488
RS232
RS232 Fiber optic
USB 2.0
Ethernet Remote control: rear panel
RF Safety interlock

COOLING: Forced air (self-contained fans), air entry and exit in rear.

DOCUMENTATION: Minimum -
Operators manual
Block Diagrams
Wiring Diagrams
Schematics
Bill of Materials
Assembly drawings
Interlock Diagrams
Test data – Test Setup Diagram.
Proof of Compliance. – Test Data.
Saturated power: - Swept Power out plots: Frequency versus power out, with associated tabular data, at 0 dBm input.
Linear Power: determine the point of where a 10 dB decrease in input power results in a 9dB decrease in output power for 1dB compression, and a 7dB decrease in output for 3dB compression. The corresponding output power is measured and graphed. This is repeated across the frequency range.
Gain Flatness: Power input level is set to -20dBm. The output power is then read across the frequency range.
Harmonics: Power input level is set to 0 dBm. Using a Spectrum analyzer record the amplitude of fundamental carrier frequency in dBm. The levels of the second and third harmonics are measured in dBm are subtracted from the level of the fundamental. This is repeated across the frequency range.
Service manual
Installation instructions
Warranty

Sheet2

Compliant?NotesSpecification Requirements
The amplifier will have:
RF and hardware protection systems including
YesHigh VSWR
YesOver-current and voltage protection
YesRedundant thermal and airflo w sensors to prevent the amplifier from overheating
Yes13 dBm max The amplifier will be protected from RF input overdrive when the RF input level is increased above max input .
YesThe RF amplifier stages will be protected when an over-temperature condition occurs due to cooling blockage or fan failure .
YesThe amplifier will have a front panel digital display that shows for ward and reflected output
Plus extensive system status and self-diagnostic information . Status indicators include:
YesPower on
YesWarm-up
YesStandby
YesOperate
YesFaults
YesExcess reflected power warning
YesUSB , Ethernet ,GPIB and RS232 GUI interface Remote
YesThe amplifier operating parameters are simultaneously available in the amplifier front panel display as well as over the remote bus.
Selection switches or keystroke allow you to switch the amplifier to the desired mode of operation for local control if the unit is not being
Yesoperated remotely.
YesAmplifier will include a built-in IEEE-488 (GPIB) interface, RS-232 and Ethernet interface.
YesAmplifier features will include
YesVSWR protection
YesGain control
YesForward and reflected RF output sample ports
NoAuto sleep
Plus monitoring of:
YesTWT helix current
YesCathode voltage
YesCollector voltage
NoHeater current
NoHeater voltage
YesBaseplate temperature
YesCabinet temperature
YesAmplifier will be modular in design for easy access and repair of the power supply and RF components.
With RestrictionsAmplifier is housed in two cabinets, 45" W x 70"H x 36" DAmplifier will be housed in a cabinet, with front handles for benchtop use but can be removed from the cabinet for rack mounting.
Specifications:
YesFrequency Range: 2.5 - 7.5 GHz instantaneously minimum
YesINPUT FOR RATED OUTPUT: 1.0 milli watt maximum (O dBm)
1500 Watt min 2000 Watt typical
NOTE: This design is based on combining 4 ea. TWT's, rated at approximately 535 W Rated Power@ OUTPUT CONNECTOR: 22000 Watts Minimum each. These are the most powerful tubes available to us. To guarantee more than
No2000 W minimum across all operating conditions would require us to combine 8 TWT's instead of four and would more than double the price of the amplifier.
YesPower output @ ldB Compression: 400 watts minimum
NoFlatness:+/- 3.0dB @rated Power 8 dB max FLATNESS: Design goal ±1/5 dB typical , ±2.0 dB maxi mum.
YesGAIN: 62 dB minimum
YesGAIN ADJUSTMENT: Continuous range: 35 dB minimum
YesINPUT IMPEDANCE: 50 ohms, VSWR 2.0:1 maximum
YesOUTPUT IMP EDANCE: 50 ohms, VSWR 2.5:1 typical
Compliant? Notes Specification Requirements
MISMATCH TOLER ANCE: Output power foldback protection at reflected power exceeding 300 watt s. Will operate without damage or oscillation with any magnitude and phase of source and load impedance. May oscillate with unshielded open due to coupling to input.
YesShould not be tested with connector off.
YesMODULATION CAPABILITY: Will faithfully reproduce AM , FM , or pulse modulation appearing on the input signal.
UnknownNOISE POWER DENSITY: - 85 dBm/ Hz (maxi mum), -95 dBm/Hz (typical)
YesHARMONIC DISTORTION: Minus 15 dBc or bett er.
YesOperating Temperature: 32 to 122 degrees F (0 to 50 degrees C)
Our initial bid erroneously stated the non-operating temperature range to be -202 to
Yes702 C. The non-operating temperature range of the T7525-2000 is -402 to 702 C, Non-operating Temperature: -40 to 158 degrees F (-40 to 70 degrees C) which is compliant with the specification requirement.
YesAltitude : 0 to 6000 feet operating
YesPRIMARY POWER: 360-435 VAC, 3 phase, WYE (5 wire), 50/60 Hz
CONNECTORS:
YesRF input : Type N female, front panel
YesForward and reflected power sample port s, front panel
Our initial bid erroneously stated the RF Output Connector would be Type 1-4/ 8 EIA Female. In fact, neither th e Type 1-4/8 EIA nor the Type 1-5/8 EIA connector is suitable for thi s application. Type 1-5/8 EIA connectors are rated to a maximum
frequency of app roximately 3 GHz, which excludes it from use with a 2.5 to 7.5 GHz RF output: Type 1-5/8 EIA female, rear panel amplifier. The T7525-2000 will incorporate a WRD250 ridged waveguide connector on
the rear panel. WRD250 is rated for operation bet ween 2.6 and 7.8 GHz and can
handle the power required for this application. It will operate below 2.6 GHz, but there will be some attanuation .
No
Remote computer interfaces
YesGPIB IEEE-488
YesRS232
NoRS232 Fiber optic
YesUSB 2.0
YesEthernet Remote control : rear panel
YesRF Safety interlock
YesCOOLING: Forced air (self-contained fans), air entry and exit in rear.
DOCUMENTATION: Minimum -
YesOperators manual
YesBlock Diagrams
YesWiring Diagrams
YesSchematics
YesBill of Materials
noAssembly dra wings
YesInterlock Diagrams
YesTest data -Test Setup Diagram.
YesProof of Compliance . - Test Data.
YesSaturated power: - Swept Po wer out plots: Frequency versuspo wer out, with associated tabular data, at O dBm input.
Linear Power: determine the point of where a 10 dB decrease in input power results in a 9dB decrease in output power for ldB compression , and a 7dB decrease in output for 3dB compression. The corresponding output power is measured and graphed. This is repeated across the frequency range.
Yes
YesGain Flatness: Power input level is set to -20dBm. The output power is then read across the frequency range.
Harmonics: Power input level is set to O dBm. Using a Spectrum analyzer record the amplitude of fundamental carrier frequency in dBm. The levels of the second and third harmonics are measured in dBm are subtracted from the level of the fundamental. This is repeated across the frequency range.
Yes
Compliant? Notes Specification Requirements
YesService manual
YesInstallation instructions
YesWarranty

File details come from the government source that posted it.