| 6000 Watt Power Amplifier 80 to 1000 MHz | |||
| Condition | New | ||
| Frequency Range | 80 - 1000 MHz | ||
| Output power at the output connector | 6000 watts minimum | ||
| Compliant? | Notes | Specification Requirement | |
| The amplifier will have: | |||
| RF & hardware protection including | |||
| high VSWR | |||
| over-current | |||
| voltage protection | |||
| redendant thermal and airflow sensors to prevent amplifier from overheating. | |||
| The amplifier will be protected from RF input overdrive when the RF input level is increased above max input. | |||
| The RF amplifier stages will be protected when an over-temperature condition occurs due to cooling blockage or fan failure. | |||
| The amplifier will have a front panel digital display that shows forward and reflected output | |||
| Plus extensive system status and self-diagnostic information. Status indicators include: | |||
| power on | |||
| warm-up | |||
| standby | |||
| operate | |||
| faults | |||
| excess reflected power warning | |||
| remote. | |||
| The amplifier operating parameters are simultaneously available in the amplifier front panel display as well as over the remote bus. | |||
| Selection switches or keystroke allow you to switch the amplifier to the desired mode of operation for local control if the unit is not being operated remotely. | |||
| Amplifier will include a built-in IEE-488 (GPIB) interface, RS-232 and Ethernet interface: | |||
| Amplifier features will include: | |||
| VSWR protection | |||
| gain control | |||
| internal automatic level control | |||
| forward and reflected RF output sample ports on front panel on front panel | |||
| plus monitoring of: | |||
| TWT helix current | |||
| cathode voltage | |||
| collector voltage | |||
| heater current | |||
| heater voltage | |||
| baseplate temperature | |||
| cabinet temperature. | |||
| Amplifier will be modular in design for easy access and repair of the power supply and RF components. | |||
| Specification Requirement: | |||
| Frequency Range: | 80 - 1000 MHz | ||
| Input for rated output: | 1.0 milliwatt maximum (0 dBm) | ||
| Rated Power @ Output Connector: | 6000 Watts minimum | ||
| Power output @ 1 dB compression | 4500 wats minimum | ||
| Flatness: | ±2 dB typical | ||
| Gain: | 67.8 dB minimum | ||
| Gain Adjust: | Continuous range: 25 dB minimum | ||
| Input Impedance | 50 ohms, VSWR 1.5:1 maximum | ||
| Output Impedance | 50 ohms, VSWR | ||
| VSWR Reflected Power Protection | Will automatically reduce the input drive and fold back the output power when the average reflected power exceed 3.0:1. The unit opeates without damage or oscillation inot any magnitude of phase or load impedance. | ||
| Mismatch Tollerance: | 100% of rated power without foldback, up to 6.0:1. Will operate without damage or oscillation with any magnitude and phase of source and load impedance | ||
| Moduation Capability: | Will faithfully reproduce AM, FM, or pulse modulation appearing on the input signal. | ||
| Noise Figure: | 6.2 dB or better. | ||
| Harmonic Distortion: | -20 dBc | ||
| Spurious Outputs: | -65 dBc | ||
| Operating Temperature: | 32 to 122 degrees F (0 to 50 degrees C) | ||
| Non-operating Temperature: | -40 to 158 degrees F (-40 to 70 degrees C) | ||
| Altitude: | 0 to 6000 feet operating | ||
| Primary Power: | 208 VAC, WYE (5 wire), 50/60 Hz, 3-phase | ||
| Connectors: | |||
| RF input: Type N female, front panel | |||
| Forward and reflected power sample ports, Type N female, front panel | |||
| RF output: Type 1-5/8 EIA female, rear panel | |||
| Remote computer interfaces | |||
| GPIB IEEE-488 | |||
| RS232 | |||
| RS232 Fiber optic | |||
| USB 2.0 | |||
| Ethernet Remote control: rear panel | |||
| RF Safety interlock |
COOLING: Forced air (self-contained fans), air entry and exit in rear.
| DOCUMENTATION: Minimum - | |
| Operators manual | |
| Block Diagrams | |
| Wiring Diagrams | |
| Schematics | |
| Bill of Materials | |
| Assembly drawings | |
| Interlock Diagrams | |
| Test data – Test Setup Diagram. | |
| Proof of Compliance. – Test Data. | |
| Saturated power: - Swept Power out plots: Frequency versus power out, with associated tabular data, at 0 dBm input. | |
| Linear Power: determine the point of where a 10 dB decrease in input power results in a 9dB decrease in output power for 1dB compression, and a 7dB decrease in output for 3dB compression. The corresponding output power is measured and graphed. This is repeated across the frequency range. | |
| Gain Flatness: Power input level is set to -20dBm. The output power is then read across the frequency range. | |
| Harmonics: Power input level is set to 0 dBm. Using a Spectrum analyzer record the amplitude of fundamental carrier frequency in dBm. The levels of the second and third harmonics are measured in dBm are subtracted from the level of the fundamental. This is repeated across the frequency range. | |
| Service manual | |
| Installation instructions | |
| Warranty |
Sheet2
| Compliant? | Notes | Specification Requirements |
| The amplifier will have: | ||
| RF and hardware protection systems including | ||
| Yes | High VSWR | |
| Yes | Over-current and voltage protection | |
| Yes | Redundant thermal and airflo w sensors to prevent the amplifier from overheating | |
| Yes | 13 dBm max The amplifier will be protected from RF input overdrive when the RF input level is increased above max input . | |
| Yes | The RF amplifier stages will be protected when an over-temperature condition occurs due to cooling blockage or fan failure . | |
| Yes | The amplifier will have a front panel digital display that shows for ward and reflected output | |
| Plus extensive system status and self-diagnostic information . Status indicators include: | ||
| Yes | Power on | |
| Yes | Warm-up | |
| Yes | Standby | |
| Yes | Operate | |
| Yes | Faults | |
| Yes | Excess reflected power warning | |
| Yes | USB , Ethernet ,GPIB and RS232 GUI interface Remote | |
| Yes | The amplifier operating parameters are simultaneously available in the amplifier front panel display as well as over the remote bus. | |
| Selection switches or keystroke allow you to switch the amplifier to the desired mode of operation for local control if the unit is not being | ||
| Yes | operated remotely. | |
| Yes | Amplifier will include a built-in IEEE-488 (GPIB) interface, RS-232 and Ethernet interface. | |
| Yes | Amplifier features will include | |
| Yes | VSWR protection | |
| Yes | Gain control | |
| Yes | Forward and reflected RF output sample ports | |
| No | Auto sleep | |
| Plus monitoring of: | ||
| Yes | TWT helix current | |
| Yes | Cathode voltage | |
| Yes | Collector voltage | |
| No | Heater current | |
| No | Heater voltage | |
| Yes | Baseplate temperature | |
| Yes | Cabinet temperature | |
| Yes | Amplifier will be modular in design for easy access and repair of the power supply and RF components. | |
| With Restrictions | Amplifier is housed in two cabinets, 45" W x 70"H x 36" D | Amplifier will be housed in a cabinet, with front handles for benchtop use but can be removed from the cabinet for rack mounting. |
| Specifications: | ||
| Yes | Frequency Range: 2.5 - 7.5 GHz instantaneously minimum | |
| Yes | INPUT FOR RATED OUTPUT: 1.0 milli watt maximum (O dBm) |
| 1500 Watt min 2000 Watt typical | |
| NOTE: This design is based on combining 4 ea. TWT's, rated at approximately 535 W Rated Power@ OUTPUT CONNECTOR: 22000 Watts Minimum each. These are the most powerful tubes available to us. To guarantee more than | |
| No | 2000 W minimum across all operating conditions would require us to combine 8 TWT's instead of four and would more than double the price of the amplifier. |
| Yes | Power output @ ldB Compression: 400 watts minimum |
| No | Flatness:+/- 3.0dB @rated Power 8 dB max FLATNESS: Design goal ±1/5 dB typical , ±2.0 dB maxi mum. |
| Yes | GAIN: 62 dB minimum |
| Yes | GAIN ADJUSTMENT: Continuous range: 35 dB minimum |
| Yes | INPUT IMPEDANCE: 50 ohms, VSWR 2.0:1 maximum |
| Yes | OUTPUT IMP EDANCE: 50 ohms, VSWR 2.5:1 typical |
| Compliant? Notes Specification Requirements | |
| MISMATCH TOLER ANCE: Output power foldback protection at reflected power exceeding 300 watt s. Will operate without damage or oscillation with any magnitude and phase of source and load impedance. May oscillate with unshielded open due to coupling to input. | |
| Yes | Should not be tested with connector off. |
| Yes | MODULATION CAPABILITY: Will faithfully reproduce AM , FM , or pulse modulation appearing on the input signal. |
| Unknown | NOISE POWER DENSITY: - 85 dBm/ Hz (maxi mum), -95 dBm/Hz (typical) |
| Yes | HARMONIC DISTORTION: Minus 15 dBc or bett er. |
| Yes | Operating Temperature: 32 to 122 degrees F (0 to 50 degrees C) |
| Our initial bid erroneously stated the non-operating temperature range to be -202 to | |
| Yes | 702 C. The non-operating temperature range of the T7525-2000 is -402 to 702 C, Non-operating Temperature: -40 to 158 degrees F (-40 to 70 degrees C) which is compliant with the specification requirement. |
| Yes | Altitude : 0 to 6000 feet operating |
| Yes | PRIMARY POWER: 360-435 VAC, 3 phase, WYE (5 wire), 50/60 Hz |
| CONNECTORS: | |
| Yes | RF input : Type N female, front panel |
| Yes | Forward and reflected power sample port s, front panel |
| Our initial bid erroneously stated the RF Output Connector would be Type 1-4/ 8 EIA Female. In fact, neither th e Type 1-4/8 EIA nor the Type 1-5/8 EIA connector is suitable for thi s application. Type 1-5/8 EIA connectors are rated to a maximum | |
| frequency of app roximately 3 GHz, which excludes it from use with a 2.5 to 7.5 GHz RF output: Type 1-5/8 EIA female, rear panel amplifier. The T7525-2000 will incorporate a WRD250 ridged waveguide connector on | |
| the rear panel. WRD250 is rated for operation bet ween 2.6 and 7.8 GHz and can | |
| handle the power required for this application. It will operate below 2.6 GHz, but there will be some attanuation . | |
| No | |
| Remote computer interfaces | |
| Yes | GPIB IEEE-488 |
| Yes | RS232 |
| No | RS232 Fiber optic |
| Yes | USB 2.0 |
| Yes | Ethernet Remote control : rear panel |
| Yes | RF Safety interlock |
| Yes | COOLING: Forced air (self-contained fans), air entry and exit in rear. |
| DOCUMENTATION: Minimum - | |
| Yes | Operators manual |
| Yes | Block Diagrams |
| Yes | Wiring Diagrams |
| Yes | Schematics |
| Yes | Bill of Materials |
| no | Assembly dra wings |
| Yes | Interlock Diagrams |
| Yes | Test data -Test Setup Diagram. |
| Yes | Proof of Compliance . - Test Data. |
| Yes | Saturated power: - Swept Po wer out plots: Frequency versuspo wer out, with associated tabular data, at O dBm input. |
| Linear Power: determine the point of where a 10 dB decrease in input power results in a 9dB decrease in output power for ldB compression , and a 7dB decrease in output for 3dB compression. The corresponding output power is measured and graphed. This is repeated across the frequency range. | |
| Yes | |
| Yes | Gain Flatness: Power input level is set to -20dBm. The output power is then read across the frequency range. |
| Harmonics: Power input level is set to O dBm. Using a Spectrum analyzer record the amplitude of fundamental carrier frequency in dBm. The levels of the second and third harmonics are measured in dBm are subtracted from the level of the fundamental. This is repeated across the frequency range. | |
| Yes |
| Compliant? Notes Specification Requirements | |
| Yes | Service manual |
| Yes | Installation instructions |
| Yes | Warranty |
File details come from the government source that posted it.