W91QVN20R0007 Solicitation.pdf

PDF 905 KB Posted

Attached to
MA IDIQ Contract General Building Repair and Construction, USAG Humphreys, Area III
Solicitation number
W91QVN20R0007
Issued by

About this file

This is a solicitation for a multiple award indefinite delivery indefinite quantity contract to provide general building repair and construction services at US Army Garrison Humphreys in Area III of the Republic of Korea. Services will include work on ceilings, walls, floors, doors, windows, roofs, mechanical and electrical systems, and other general construction and repair tasks. Task orders under $250,000 will be awarded under this solicitation, while larger task orders requiring design will be awarded under a separate multiple award IDIQ contract. Questions regarding this solicitation should be directed to the points of contact listed. Offerors must submit proposals by 27 April 2020 for evaluation and award.

View the file

Other files

File Type Posted
W91QVN20R0007_Amd0001.pdf PDF
W91QVN20R0007 Attachment 1-Pricing Schedule.xls XLS spreadsheet
W91QVN20R0007 Attachment 2-UM Abbreviation.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Title: Multiple Aw ard (MA) Indefinite Delivery and Indefinite Quantity (IDIQ) Contract for General Building Repair and Construction, US Army Garrison (USAG) Humphreys, Area III, Republic of Korea (ROK). This IDIQ w ill be used for simple and small w ork for the task order limitation of $250,000. MA IDIQ Contract, Repair and Upgrade of USFK facilities for Area III (Contract No. W91QVN-18-D-0053, 0054, 0056, 0057, 0058, 0059, 0060, 0062, 0064, 0065, 0066, 0069, 0070, 0071, 0072, 0073, 0074, 0076, 0077, 0163) w ill be used for the high dollar amount that requires design.

Question shall be emailed to suchong.kang.ln@mail.mil and jean.k.ross.civ@mail.mil.

MS. KANG, SU-CHONG 315-755-3394

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS

NEGOTIATED

24-Mar-2020

(RFP)

(IFB)

X

CALL:

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

See Item 7

2. TYPE OF SOLICITATION

SEALED BID

3. DATE ISSUED

9. FOR INFORMATION A. NAME

SOLICITATION

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

11. The Contractor shall begin performance w ithin _______10 calendar days and complete it w ithin ________ calendar days after receiving aw ard, X notice to proceed. This performance period is X mandatory, negotiable. (See _________________________

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

YES X NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and __________ copies to perform the w ork required are due at the place specified in Item 8 by ___________ local time ______________27 Apr 2020 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.

shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is, X is not required.

C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than _______180 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

7. ISSUED BY CODE

411TH CONTRACTING SUPPORT BRIGADE, KOREA

CONSTRUCTION & SUPPLY DIV, UNIT #15289

APO AP 96271

UNITED STATES

W91QVN

PAGE OF PAGES

1 OF

CODE

(Title, identifying no., date):

12B. CALENDAR DAYS

07:00 AM (hour)

Sealed envelopes containing offers

5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

8. ADDRESS OFFER TO (If Other Than Item 7)

FAX:TEL: TEL: FAX:

W91QVN20R0007 112

20B. SIGNATURE

(REV. 4-85)STANDARD FORM 1442 BACK

TO SIGN

NSN 7540-01-155-3212

SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)

CODE FACILITY CODE

17. The offeror agrees to perform the w ork required at the prices specif ied below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.

the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS SEE SCHEDULE OF PRICES

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN

OFFER (Type or print)

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM

(4 copies unless otherwise specified)

CODE

(Insert any number equal to or greater than

20C. OFFER DATE

25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) 41 U.S.C. 253(c)

CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY

(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)

See Item 14

(Include only if different than Item 14)16. REMITTANCE ADDRESS

30B. SIGNATURE

29. AWARD (Contractor is not required to sign this document.)

document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .

gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)

30C. DATE

(Type or print)

TEL: EMAIL:

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

(Contractor is required to sign this28. NEGOTIATED AGREEMENT

(M ust be fully completed by offeror)OFFER

W91QVN20R0007

Section B - Supplies or Services and Prices

ITEM NO SUPPLIES/SERVICES MAX

QUANTITY

UNIT UNIT PRICE MAX AMOUNT

0001 500 Job Base Period

FFP

The contractor shall provide all necessary resources to perform general building repair and construction, USAG Humphreys, Area III, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. ***Unit price shall include total amounts covering all line items for Base Period outlined in Attachment 1 in Section J*** FOB: Destination

PSC CD: Z1AZ

MAX

NET AMT

UNIT UNIT PRICE MAX AMOUNT

0002 500 Job Estimated cost for War Hazard Losses

FFP

is zero(0).

UNIT UNIT PRICE MAX AMOUNT

1001 500 Job OPTION 1st Option Period

FFP

The contractor shall provide all necessary resources to perform general building repair and construction, USAG Humphreys, Area III, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. ***Unit price shall include total amounts covering all line items for 1st Option Period outlined in Attachment 1 in Section J***

UNIT UNIT PRICE MAX AMOUNT

1002 500 Job OPTION Estimated cost for War Hazard Losses

FFP

is Zero(0).

UNIT UNIT PRICE MAX AMOUNT

2001 500 Job OPTION 2nd Option Period

FFP

The contractor shall provide all necessary resources to perform general building repair and construction, USAG Humphreys, Area III, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. ***Unit price shall include total amounts covering all line items for 2nd Option Period outlined in Attachment 1 in Section J***

UNIT UNIT PRICE MAX AMOUNT

2002 500 Job OPTION Estimated cost for War Hazard Losses

FFP

is zero(0)

UNIT UNIT PRICE MAX AMOUNT

3001 500 Job OPTION 3rd Option Period

FFP

The contractor shall provide all necessary resources to perform general building repair and construction, USAG Humphreys, Area III, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. ***Unit price shall include total amounts covering all line items for 3rd Option Period outlined in Attachment 1 in Section J***

UNIT UNIT PRICE MAX AMOUNT

3002 500 Job OPTION Estimated cost for War Hazard Losses

FFP

is zero(0).

UNIT UNIT PRICE MAX AMOUNT

4001 500 Job OPTION 4th Option Period

FFP

The contractor shall provide all necessary resources to perform general building repair and construction, USAG Humphreys, Area III, in accordance with the statement of work, specifications, drawings at all terms and conditions contained herein. Actual work to be performed will be identified by individual task order issued under the line item. ***Unit price shall include total amounts covering all line items for 4th Option Period outlined in Attachment 1 in Section J***

UNIT UNIT PRICE MAX AMOUNT

4002 500 Job OPTION Estimated cost for War Hazard Losses

FFP

is zero(0).

GENERAL DESCRIPTION

B-1. DESCRIPTION

a. The Contractor shall provide all labor, tools, materials, transportation, equipment, supplies, and other necessary resources for General Building Repair and Construction, USAG Humphreys, Area III, in accordance the Statement of Work (SOW), specifications, drawings and terms and conditions contained herein.

b. The statement of work (SOW) in this section broadly defines repair and construction of general buildings and exterior site. Each individual task order shall be issued which specifically defines the scope of work to be performed herein. Pricing for the work to be performed shall be taken from the Sub-CLINs associated with each line item that are incorporated into the contract.

B-2. CONTRACT TYPE: This is a Multiple Award Indefinite Delivery Indefinite Quantity (MA IDIQ) Firm Fixed Price (FFP) Task Order Contract. All supplies/services will be obtained by individual task orders issued by the Contracting Officer, 411th Contracting Support Brigade (CSB).

B-3. MINIMUM GUARANTEE/MAXIMUM POTENTIAL COMBINED CEILING AMOUNT

a. This IDIQ will be used for simple and small work (Not to exceed $250,000). MA IDIQ Contract, Repair and Upgrade of USFK facilities for Area III (Contract No. W91QVN-18-D-0053, 0054, 0056, 0057, 0058, 0059, 0060, 0062, 0064, 0065, 0066, 0069, 0070, 0071, 0072, 0073, 0074, 0076, 0077, 0163) will be used for the high dollar amount that requires design.

b. If the Government determines to make multiple awards, each IDIQ contract award will have a minimum guarantee of $3,000 for base period only regardless of the number of awards. The maximum potential combined ceiling amount under each IDIQ contract will not exceed $60,000,000 for the base and all options. The total of all contracts awarded will not exceed the ceiling amount of $60,000,000 during the five years.

c. The minimum guarantee for the total IDIQ is provided in the amount of $3,000 and shall be obligated by issuance of a task order during the base period. The guarantee/limitations by year will be equivalent to the Contract Korean Won Rate for the following dollar amounts.

d. The maximum potential combined ceiling amount in the resulting contract is not the actual contract amount. The maximum potential combined ceiling amount is the ceiling amount for the total price of task orders that the Government will issue in a given contract period, not to exceed the stated maximum amount in B-2.

Period Minimum Guarantee Maximum Potential Combined Ceiling Amount

Base Period $3,000 $12,000,000 1st Option Period $0 $12,000,000 2nd Option Period $0 $12,000,000 3rd Option Period $0 $12,000,000 4th Option Period $0 $12,000,000

Section C - Descriptions and Specifications

TECHNICAL PROVISION I

STATEMENT OF WORK

1. DESCRIPTION: The Contractor shall provide all labor, tools, equipment, transportation, materials and other necessary resources to accomplish the scope of work contained in the schedule and in accordance with the drawings, statement of work, specifications and terms and conditions of the individual task order. The type of work anticipated hereunder shall consist of but is not limited to the following: ceilings, walls, floors, doors, windows, latrines, roofing, mechanical work, civil work, and electrical work.

2. PRINCIPAL FEATURES: This project includes the following principal features; General Construction contract in accordance with the detailed specifications and drawings as provided under individual task orders. In performing work under individual task orders, contractors must comply with the following:

Schedule – Repair/Maintenance (K): All work shall be in accordance with the attached drawings and specifications.

General Work

1. Boiler worker

2. Carpenter (Concrete form)

3. Carpenter (Construction)

4. Carpenter (Door & window)

5. Common labor

6. Concrete worker

7. Communication worker

8. Duct worker

9. Exterior electrician

10. Glazer

11. Insulation worker

12. Interior electrician

13. Interior finish worker

14. Mason

15. Mechanical equipment installer

16. Painter

17. Plumber

18. Paving worker

19. Roof worker

20. Steel worker

21. Tile worker

22. Water proofing worker

23. Welder

24. Project manager

25. Safety manager

26. Quality controller

27. Backhoe 0.6

28. Backhoe 0.4

29. Backhoe 0.2

30. Concrete pump truck 43m

31. Crane wheel type 250t

32. Crane wheel type 200t

33. Crane wheel type 160t

34. Crane wheel type 130t

35. Crane wheel type 100t

36. Crane wheel type 80t

37. Crane wheel type 50t

38. Dump 15t

39. Fork lift 5t

40. Fork lift 7.5t

41. Trailer 20T

42. Truck, cargo 4.5T

43. Backhoe 0.6 w/ breaker

44. Backhoe 0.2 w/ breaker

Civil Work

1. PE (Poly Ethylene) safety fence

2. EGI (Electrolytic Galvanized Iron) Safety fence 2.4m for 3 months

3. EGI Safety fence 2.4m for 6 months

4. Double cord scaffolding with temporary stair or slope for 3 month rental, base on H30.0m

5. Double cord scaffolding with temporary stair or slope for 6 month rental, base on H30.0m

6. Rolling trestle scaffolding, 6'x4', for 3month rental, base on H2.0m

7. Rolling trestle scaffolding, 6'x4', for 6month rental, base on H2.0m

8. Rolling trestle scaffolding, 6'x4', for 3month rental, base on H4.0m

9. Rolling trestle scaffolding, 6'x4', for 3month rental, base on H4.0m

10. Shoring (h4.0m,B1.5m)

11. Treatment of Construction waste

12. Treatment of designated landfill waste

13. Fabricate standard concrete forms for pad, slab, retaining wall, cantilever wall, foundation, pedestal wall, culvert, column, beam, girder and all R.C (Reinforced concrete) structure, form height: below 3,048mm, included form tie, wedge fin, spacer, chamfer strip, hook, clamp and all other supporting form accessories

14. Fabricate standard concrete forms for pad, slab, retaining wall, cantilever wall, foundation, pedestal wall, culvert, column, beam, girder and all R.C structure, form height: 3,048 thru 6,096mm, included form tie, wedge fin, spacer, chamfer strip, hook, clamp and all other supporting form accessories

15. Install Metallic or Non-Metallic water stop with adhesive and sealant

16. Install dowel bar with cap on expansion joint, below 30D, Length: 600mm

17. Install expansion/Contraction joint filler, 130mm thick

18. Fabricate deformed reinforce steel bars, D10 thru D29, for pad, slab, retaining wall, cantilever wall, foundation, pedestal wall, culvert, column, beam, girder and all R.C structure, Per 100kg of standard KS D 3629 reinforcing steel fabrication

19. Place welded wire fabric in concrete slab or pad, #4, 150 x 150mm

20. Install reinforced Conc. 4'W Step included base course and step nosing

21. Place 27MPa ready mixed concrete by backhoe, included surface finish, vibrator and operators with equipment, below 6CM per 1 placing

22. Place 27MPa ready mixed concrete by backhoe, included surface finish, vibrator and operators with equipment, above or equal 6CM per 1 placing

23. Place 27MPa ready mixed concrete, included surface finish and vibrator under below 100CM

24. Place 27MPa ready mixed concrete, included surface finish and vibrator, 100CM thru 200CM

25. Concrete pump truck rental cost less than 4 hours

26. Concrete pump truck rental cost, full days, 8 hours

27. Removal of concrete

28. Removal of reinforced concrete

29. Removal of Asphalt concrete

30. Excavation

31. Disposal of Soil

32. Engineering Fill

33. Install Gabion

34. Install 280mm thk Sub-Base Course

35. Base course levelling and compaction density 95%

36. Install 125mm thk Base Course

37. Install 150mm thk Base Course

38. AC. Surface Milling - 50mm thk.

39. AC. Surface Milling - 75mm thk.

40. AC. Surface Milling - 100mm thk.

41. Temporary Road (Gravel), 300mm Thk

42. Install or Overlay 50mm thk. A/C (#78)

43. Install or Overlay 75mm thk. A/C (#78)

44. Install or Overlay 100mm thk. A/C (#78)

45. Install 100mm thk. Reinforced Conc. Slab

46. Install 100mm thk. Conc. Slab

47. Install 150mm thk. Reinforced Conc. Slab

48. Install 150mm thk. Conc. Slab

49. Install 200mm thk. Reinforced Conc. Slab

50. Install 200mm thk. Conc. Slab

51. Install 250mm thk. Reinforced Conc. Slab

52. Install 250mm thk. Conc. Slab

53. Install 300mm thk. Reinforced Conc. Slab

54. Install 300mm thk. Conc. Slab

55. Install Sidewalk with Base Course, expansion and contraction joint, bloom finish and chamfered edge

56. Install Conc. Curb

57. Install Granite Stone Curb

58. Install Conc. Gutter

59. Construct conc. Drainage/Surface Inlet including Cast Iron Grating and drain manhole

60. Install handrail

61. Install 190mm x 90mm x 57mm red brick wall

62. Paint reflective, 100mm wide pavement marking include bead

63. Paint reflective, 150mm wide pavement marking include bead

64. Paint reflective, 150mm, 300mm or/and 600mm Marking letter include bead

65. Paint reflective marking Handicap symbol

66. Paint 100mm wide stripe, reflective parking stall painting (Per EA)

67. Paint 150mm wide stripe, reflective parking stall painting (Per EA)

68. Install Traffic/Parking sign Board with 2"Dia Stl.(steel) Post & brackets

69. Install information sign Board with 2"Dia Stl. Post & brackets

70. Install Handicap parking sign 2"Dia Stl. Post & brackets

71. Install vehicle Wheel Stop

72. Install chain link fence with barbed wire on single arm, Type FE-6, Fabric width: 2,100 thru 2,400 included concrete footing

73. Install chain link fence with barbed wire on double arm, Type FE-7, Fabric width: 2,100 thru 2,400 included concrete footing

74. Install chain link fence with barbed wire and concertina wire on double arm, Type FE8, Fabric width: 2,100 thru 2,400 included concrete footing

75. Install double swing gate with gate posts, Type FE-6/7 included hinge, drop rod, latch assembly, grounding rod, wire and clamp

76. Install personnel gate with gate posts, Type FE-6/7 included hinge, drop rod, latch assembly, grounding rod, wire and clamp

77. Install Seeding

78. Replace existing Top Soil with 100mm thk. Top Soil

79. Install 100mm thk. Top Soil

80. Install Spot Sodding

81. Install Strip Sodding

82. Install Solid Sodding

83. Install Landscape Conc. Block

84. Removal of Tree

85. Plant Tree

86. Removal of Water Line & Plug, (up to 300mm Dia.) (Per LM)

87. Install 50mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)

88. Install 75mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)

89. Install 100mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)

90. Install 150mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)

91. Install 200mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)

92. Install 250mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)

93. Install 300mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)

94. Install 50mm dia. Gate valve & thrust block (Per EA)

95. Install 75mm dia. Gate valve & thrust block (Per EA)

96. Install 100mm dia. Gate valve & thrust block (Per EA)

97. Install 150mm dia. Gate valve & thrust block (Per EA)

98. Install 200mm dia. Gate valve & thrust block (Per EA)

99. Install 250mm dia. Gate valve & thrust block (Per EA)

100. Install 300mm dia. Gate valve & thrust block (Per EA)

101. Install Gate Valve Box (Per EA)

102. Install Indicator Post (Per EA)

103. Install Fire Hydrant and Guard Post (Per EA)

104. Install 100mm bend & thrust block (Per EA)

105. Install 150mm bend & thrust block (Per EA)

106. Install 200mm bend & thrust block (Per EA)

107. Install 250mm bend & thrust block (Per EA)

108. Install 300mm bend & thrust block (Per EA)

109. Install 100 mm dia. Tee & thrust block (Per EA)

110. Install 150 mm dia. Tee & thrust block (Per EA)

111. Install 200 mm dia. Tee & thrust block (Per EA)

112. Install 250 mm dia. Tee & thrust block (Per EA)

113. Install 300 mm dia. Tee & thrust block (Per EA)

114. Install Valve Box (1.5m x 2m x 2m Depth) w/Lockable Cover for Security (Per EA)

115. Install Valve Box (3m x 5m x 2m Depth) w/Lockable Cover for Security (Per EA)

116. Install 50mm dia Check Valve (Per EA)

117. Install 100mm dia Check Valve (Per EA)

118. Install 150mm dia Check Valve (Per EA)

119. Install Flow Meter 50mm dia & Pressure Gage (Per EA)

120. Install Flow Meter 100mm dia & Pressure Gage (Per EA)

121. Install Flow Meter 150mm dia & Pressure Gage (Per EA)

122. Install 50mm dia with Valve Box (Per EA)

123. Removal of Sewer line & plug, various size (Per LM)

124. Install Sewer Man Hole (Less than 1.8m Deep) (Per EA)

125. Install S.M.H. (1.8m - 2.4m Deep) (Per EA)

126. Install S.M.H. (2.4m - 3.0m Deep) (Per EA)

127. Install S.M.H. (3.0m - 3.6m Deep) (Per EA)

128. Install 100mm dia Surface Cleanout (Per EA)

129. Install 150mm dia Surface Cleanout (Per EA)

130. Install 200mm dia Surface Cleanout (Per EA)

131. Install 150mm dia VG-1 P.V.C Sewer Line & Fitting (PER LM)

132. Install 200mm dia VG-1 P.V.C Sewer Line & Fitting (PER LM)

133. Install 300mm dia VG-1 P.V.C Sewer Line & Fitting (PER LM)

134. Install Reinforced Concrete Encasement (PER LM) (100mm dia)

135. Install Reinforced Conc. Encasement (PER LM) (150mm dia)

136. Install Reinforced Conc. Encasement (PER LM) (200mm dia)

137. Install Reinforced Conc. Encasement (PER LM) (250mm dia)

138. Install Reinforced Conc. Encasement (PER LM) (300mm dia)

139. Install Reinforced Conc. Encasement (PER LM) (350mm dia)

140. Removal of Reinforced Concrete Pipe, Various Size (PER LM)

141. Install Surface lnlet or Catch Basin (up to 1.5m) (Per EA)

142. Install 300mm dia Reinforced Concrete Pipe (PER LM)

143. Install 450mm dia R.C.P (PER LM)

144. Install 600mm dia R.C.P (PER LM)

145. Install 1.2m W x 1.2m L x 1.6m D Conc. Manhole include Cast Iron Frame and Cover (Per EA)

146. Install Conc. Ditch (300mm W, Various Height) (PER LM)

147. Install Conc. Ditch (450mm W, Various Height) (PER LM)

148. Install Conc. Ditch (600mm W, Various Height) (PER LM)

149. Install Conc. Ditch Cover (300mm W) (Per EA) (PER LM)

150. Install Conc. Ditch Cover (450mm W) (Per EA) (PER LM)

151. Install STL Grating Cover, 20 ton Load (300mm W) (PER LM)

152. Install STL Grating Cover, 20 ton Load (450mm W) (PER LM)

153. Install STL Grating Cover, 20 ton Load (600mm W) (PER LM)

154. Install Conc. Head Wall for 450mm dia Pipe (Per EA)

155. Install Conc. Head Wall for 600mm dia Pipe (Per EA)

156. Install Turf Swale (Per SM)

157. Install Riprap Apron (Per SM)

158. Install metal post guardrail & spacer block

159. Install Metal post guardrail w/o spacer block

160. Install conc. post guard rail & spacer block

161. Install conc. post guard rail w/o spacer block

162. General Area Survey (100m x 100m, 1Day)

163. Slope and Restricted Area Survey (100m x 100m, 1Day)

164. Digitizing and topographic design - TYP.Contour span (20mm)

Architectural Work

1. Remove CMU wall, 100mm-190mm thick w/re-bars & W.W.F (Welded Wire Fabric)

2. Remove lintel or sills for windows, doors and all openings

3. Remove precast coping on top of wall

4. Remove Stainless Steel Pipe Column, 25.4mm dia. Through 76.3mm dia (diameter)

5. Remove Stainless Steel Pipe Column, 100mm dia. Through 125mm dia

6. Remove Existing Window Security Bar

7. Remove Stainless Steel Non-Slip on Stairway

8. Remove Guardrail and handrail with post, metal pipe

9. Remove 2Ply- Plywood Sheathing

10. Remove wood fascia board or soffit board with nailed

11. Remove Wood Molding

12. Remove mineral fiber blanket insulation or rigid insulation in wall, ceiling and roof deck

13. Remove Exterior Insulation and Finish System including metal lath EPS board on existing wall

14. Remove Shingle Roof With 2-Ply Asphalt Felt

15. Remove Korean Cement Roof Tile With 2-Ply Asphalt Felt, Wood Strip

16. Remove Corrugated Iron Sheet Siding

17. Remove EPDM (Ethylene Propylene Rubber Material) roofing with insulation, included seam tape, bonding adhesive and membrane flashings, lap sealant, edge treatment & EPDM sheet

18. Remove rubber wallboard on EPDM roofing sheet

19. Remove Metal Gutter or downspout with strap and hanger

20. Remove All type of Single Steel Door without door frame

21. Remove All type of Double Steel Door without door frame

22. Remove All type of Single Steel Door With Frame, lockset, hinges, threshold, exit device and trim

23. Remove All type of Double Steel Door With Frame, lockset, hinges, threshold, exit device and trim

24. Remove all type of Alum.(aluminum) door including Manual operated Entrance door without Door Frame

25. Remove All type of Alum. door including Manual operated Entrance door With Door Frame, hinges, threshold, lockset, exit device and trim including fixed glasses

26. Remove All type of wooden Single Door W/O Door Frame

27. Remove All type of wooden Double Door W/O Door Frame

28. Remove All type of Wooden Single Door With Frame, hinges, threshold, exit device and trim

29. Remove All type of Wooden Double Door With Frame, hinges, threshold, exit device and trim

30. Remove Ceiling Access Door with Frame

31. Remove All type of Alum. Auto Swing or Sliding Door With Door Frame, hinges, threshold, exit device, trim and fixed glasses, including Elec. Power and Fire alarm system disconnection

32. Remove elc.(electric) powered metal rolling counter door or overhead coiling door with guide rail, insulated slot, motor operator, hand chain hoist, locking device, weather seal and wall mounted button control station

33. Remove Aluminum Window with Frame, trim and insect screen

34. Remove Door hard wares(Exit device, Door check, Door stop, Threshold, weather-strip, Door Coordinator, Astragal, Kick plate, push plate, floor hinge and all type of lockset)

35. Remove gypsum wall board

36. Remove gypsum ceiling board

37. Remove Metal or wood member Stud & runner 50mm-203mm W. 300mm~450mm O.C

38. Remove M-Bar type metal or wood ceiling suspension system

39. Remove Cement Plaster wall including Asphalt felt, metal lath

40. Remove Ceramic wall & floor Tile

41. Remove Ceramic wall & floor Tile including setting bed

42. Remove Silicon sealants and caulking

43. Remove acoustic ceiling tile without frame

44. Remove and re-install acoustic ceiling tile

45. Remove T-bar type metal suspended ceiling system

46. Remove vinyl cove base

47. Remove vinyl composition tile

48. Remove rubber tile

49. Remove carpet or carpet tile with glue and felt

50. Remove Wallpaper

51. Remove existing paint for metal surface (By using hand & power tool machine)

52. Remove existing paint for CMU or concrete surface (By using hand & power tool machine)

53. Remove existing paint for wooden surface (By using hand & power tool machine)

54. Remove & re-install Toilet accessories (Lavatory faucet, Shower faucet, Towel bar, Mirror, Soap dish, Clotheshorse and Toilet tissue dispenser)

55. Remove and re-install Toilet Fixtures (Urinal, Water Closet, Lavatory with Cabinet including drainage system)

56. Remove Toilet Fixtures (Urinal, Water Closet, Lavatory with Cabinet including drainage system)

57. Remove Blind, Vertical or venetian

58. Remove Kitchen Wall or Base Cabinet W/ Door and countertops sized wall cabinet Depth 300-400mm X

Height 640 - 770mm or base cabinet Depth 600-650mm X Height 900-1100mm

59. Remove 40mm Max. Gravel for Capillary Water Barrier

60. Block-up window & other opening w/CMU (concrete masonry unit) wall, 100mm to 190mm thk. (O&MA

Specifications Section 04 20 00)

61. Block-up window & other opening w/#24 gage corrugated iron sheet 100mm thk insulation wood frame and interior lining

62. Install CMU wall, 100mm-190mm thick w/re-bars (O&MA Specifications Section 04 20 00)"

63. Install stainless steel non-slip on stair

64. Install ceiling access metal door w/metal frame swing up model, 450mm x 450mm

65. Install window security bar

66. Install SST (stainless steel) Fire extinguisher cabinet using tempered safety glass, 315mm wide x 765mm high x 187mm depth

67. Install wood fascia board & nailed incl. painting, 25mm x 250mm(O&MA Specifications Section 06 20 00)"

68. Install soffit board, trim & paint 12mm thick plywood(O&MA Specifications Section 06 20 00)"

69. Install wood member with stud, furring, blocking & trim at wall(O&MA Specifications Section 06 10 00)

70. Install 25mm x 100mm wood base board(O&MA Specifications Section 06 20 00)

71. Install chair rail, 100mm or 150mm oak molding(O&MA Specifications Section 06 20 00)

72. Install hardwood closet shelf, 600mm wide x 25mm thick Incl. stain & vanish finish

73. Install #24 gauge 150mm-200mm wide sheet metal rain gutter & hanger incl. painting(O&MA Specifications Section 07 60 00)"

74. Install #24 gauge 100mm-150mm dia. sheet metal downspout & strap incl. Painting(O&MA Specifications Section 07 60 00)"

75. Install basket strainer, 100mm dia. ~ 150mm dia.(O&MA Specifications Section 07 60 00)"

76. Install #24 gauge galvanized corrugated metal roof & painting(O&MA Specifications Section 07 41 13 )"

77. Install insulation w/aluminum foil jacket, in wall 75mm thick(O&MA Specifications Section 07 22 00 )

78. Install #24 gage corrugated sheet metal siding and painting(O&MA Specifications Section 07 41 13 )

79. Install #26 gage sheet metal lining on the wall, ceiling(O&MA Specifications Section 07 41 13 )

80. Install exterior insulation and finish systems on concrete or CMU or metal wall including metal lath(O&MA

Specifications Section 07 24 00 )"

81. Install asphalt shingle and 1-ply rubberized waterproofing membrane sheet(O&MA Specifications Section 07

31 13 )

82. Install 18mm thick plywood sheathing(O&MA Specifications Section 07 31 13 )

83. Install #24 gauge galvanized sheet metal flashing incl. painting for valley flashing, drip edge, window, door, corner, smoke stack, duct(O&MA Specifications Section 07 31 13 )

84. Install Korean cement roof tile, factory color finish size: 12 mm x 400 mm x 350mm with 1-ply rubberized waterproofing membrane sheet underlayment & treated battens

85. Install existing waterproofing materials and pressure wash roof surface, seal exposed cracks and crevices, apply concrete sealer, flash transition point, roof penetrations & install acrylic fluid applied waterproofing on existing concrete flat roof.(O&MA Specifications Section 07 14 00 )

86. Install exit device, type 3 or 10, F-05/08 (ANSI/BHMA A156.3)

87. Install exit device, type 2, F-01 (ANSI/BHMA A156.3)

88. Install mortise lockset, F-02, F-04, F-05, F-07, F-08 or F-13 (ANSI/BHMA A156.13)"

89. Install bored type lockset, F-82 or F-86 (ANSI/BHMA A156.2)

90. Install hinge butt, 4-1/2"" x 4-1/2"", A2111 or A5111 (ANSI/BHMA A156.1)"

91. Install hinge butt, 4-1/2" x 4-1/2", A8111 (ANSI/BHMA A156.1)

92. Install aluminum screen single door, 900mm x 2150mm

93. Install aluminum weather strip for door

94. Install astragal for door

95. Install aluminum threshold, 100mm-150mm wide

96. Install door stopper and holder, L01361, L01371, L02141, L01381, L02121, L01241. (ANSI/BHMA

A156.16)

97. Install foot bolt, 150mm long

98. Install door closer, C02021, C02011 (ANSI/BHMA A156.4)

99. Install push plate, J304 (ANSI/BHMA A156.16)

100. Install pull plate, J407 (ANSI/BHMA A156.16)

101. Install kick plate, J102 (ANSI/BHMA A156.16)

102. Install door viewer, 180 degree angle of view. L03171 (ANSI/BHMA A156.16)"

103. Install wood flush hollow core single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick

104. Install wood flush solid core single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick

105. Install wood flush half glass solid core single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick

106. Install wood flush louvered solid core single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick

107. Install steel flush insulated single door with steel door frame , 900 mm X 2,150 mm, 45 mm thick

108. Install steel flush half glass insulated single door with steel door frame , 900 mm X 2,150 mm, 45 mm thick

109. Install steel flush louvered insulated single door with steel door frame , 900 mm X 2,150 mm, 45 mm thick

110. Install steel flush insulated double door with steel door frame , 1,800 mm X 2,150 mm, 45 mm thick

111. Install steel flush insulated louvered double door with steel door frame , 1,800 mm X 2,150 mm, 45 mm thick

112. Install steel flush insulated half glass double door with steel door frame , 1,800 mm X 2,150 mm, 45 mm thick

113. Install wood flush hollow core dutch single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick

114. Install 90 minute fire rated steel flush insulated single door with steel door frame, 900 mm X 2,150 mm, 45 mm thick

115. Install 90 minute fire rated wood flush insulated single door with steel door frame, 900 mm X 2,150 mm, 45 mm thick

116. Install 45 minute fire rated wood flush insulated single door with steel door frame, 900 mm X 2,150 mm, 45 mm thick

117. Install aluminum sash sliding window & aluminum frame15 mm insulating glass, insect screen & window latch3mm glass + 6mm air space + 6mm laminated inner glass)(O&MA Specifications Section 08 51 13 )

118. Install aluminum sash sliding window & aluminum frame6mm thick laminated glass (O&MA Specifications Section 08 51 13 )

119. Install window security bar(O&MA Specifications Section 05 50 13)"

120. Install aluminum framed insect screen (O&MA Specifications Section 08 51 13 )"

121. Install screen for door & window(O&MA Specifications Section 08 51 13 )"

122. Install horizontal blind, 25mm aluminum slats incl. head channel, bracket and accessories(O&MA

Specifications Section 12 21 00 )

123. Install vertical blind, 89mm aluminum or cloth strips incl. bracket and accessories(O&MA Specifications

Section 12 21 00 )

124. Install 1,200x1,200 Dual action aluminum window(Turn and tilt) & aluminum frame"

125. Install fixed aluminum window & aluminum frame

126. Install single hung window & aluminum frame

127. Install awning with Fixed window & aluminum frame

128. Install project window & aluminum frame

129. "Replace 4.5mm thick polycarbonate sheet with caulking(O&MA Specifications Section 08 81 00 )"

130. Install wall board with 12.5mm thick gypsum board including joint taping & compound, regular type

(O&MA Specifications Section 09 29 00 )

131. Install wall board with 15mm thick gypsum board incl. joint taping & compound, type "X" (Special fire resistant )(O&MA Specifications Section 09 29 00 )

132. Install wall board with 12.5mm thick gypsum board incl. joint taping & compound, water resistant type(O&MA Specifications Section 09 29 00 )

133. Install cement plaster wall & ceiling, 15mm thick(O&MA Specifications Section 09 29 00 )

134. Install metal stud/runner for wall, 152mm wide 300mm - 450mm on center(O&MA Specifications Section 09

29 00 )

135. Install M-Bar furring for wall 22mm D x 35mm W (O&MA Specifications Section 09 22 00 )"

136. Install vinyl cove base, 100mm to 150mm high (O&MA Specifications Section 09 65 00 )

137. Install metal casing bead (O&MA Specifications Section 09 22 00 )"

138. Install wall paper (fire retardant type) Class A flame spread rating of 0-25 and smoke development rating of

0-50 when tested in accordance with ASTM E 84.(O&MA Specifications Section 09 72 00 )

139. Install gypsum wall board pipe chase with metal frame, C - 300 mm wide x 300 mm depth

140. Install plaster wall w/15# asphalt felt , metal lath (1.8kg per square meter) and 25mm thick cement plaster finish (O&MA Specifications Section 09 22 36 )

141. Install ceramic mosaic floor tile or ceramic floor tile(O&MA Specifications Section 09 30 00 )

142. Install ceramic wall tile incl. accessories (trim & corner)(O&MA Specifications Section 09 30 00 )

143. Install caulking for bathroom & kitchen(O&MA Specifications Section 09 30 00 )

144. Install ceiling board with 12.5mm thick gypsum board incl. joint taping & compound

145. Install ceiling board with 15mm thick gypsum board incl. joint taping & compound, type "X" (Special fire resistant)

146. Install ceiling board with 12.5mm thick gypsum board incl. joint taping & compound, water resistant type

147. Install 15mm thick acoustic tile incl. glue & screw

148. Install suspended ceiling metal frame for gypsum board (O&MA Specifications Section 09 20 00 )

149. Install suspended ceiling metal frame for acoustic tile(O&MA Specifications Section 09 51 00 )

150. Install vinyl composition tile 300mm x 300mm x 3mm thick(O&MA Specifications Section 09 65 00 )

151. Repair crack concrete stoop-chip off 25mm wide V-joint & seal w/cement grout(O&MA Specifications

Section 09 65 00 )

152. Repair existing floor chip off existing concrete floor and provide 50mm concrete topping (O&MA

Specifications Section 09 65 00 )

153. Install Carpet, Nylon Pattern Cut/Loop Incl. Accessories(O&MA Specifications Section 09 68 00 )

154. Install nylon carpet with level-loop, multilevel loop, cut and loop incl. accessories (O&MA Specifications Section 09 68 00 )

155. Install carpet tile, loop, incl. accessories 500mm x 500mm x 9.5mm thick (O&MA Specifications Section 09 68 00 )

156. Install vinyl composition tile, 450mm x 450mm x 3mm thick (O&MA Specifications Section 09 65 00 )

157. Install rubber tile, 500mmx500mmx4mm thick (O&MA Specifications Section 09 65 00 )

158. Install rubber stair tread with integrated riser, 480mm wide x 5mm thick (O&MA Specifications Section 09

65 00 )

159. Replace raised floor system, 600 mm X 600 mm including die cast panel, stringer, edestals, non - conductive tile and accessories(O&MA Specifications Section 09 69 13 )

160. Paint, interior , 2-coats

161. Paint, interior oil modified clear urethane, stain, 3-coats

162. Paint, exterior alkyd enamel 2-coats

163. Paint on metal surface, aluminum paint, 2 coats

164. Paint, galvanized metal primer, 1 coat

165. Paint, interior primer sealer, 1 coat

166. Paint on concrete floor, epoxy paint, 2 coats

167. Paint, stain wood floor, natural finish, 3 coats

168. Repaint for exterior insulation and finish system

169. Replace joint on gypsum board w/compound & gypsum tape

170. Seal cracks on cement plaster wall

171. Install hardener for concrete floor slab

172. Remove and Reinstall Various Furniture Including Steel or Wooden Cabinets, Shelves, Book Cases, Office

Furniture, Chairs Refrigerators & Other Office Equipment.

173. Install stainless steel (SST) shower curtain rod, w/curtain 25mm dia x 900mm - 1200mm lg.

174. Install SST robe hook

175. Install soap dish (stainless or ceramic)

176. Install metal framed glass mirror, 450mm x 600mm high.

177. Install metal framed tilting glass mirror, 400mm x 750mm high.

178. Install toilet tissue dispenser

179. Install paper towel dispenser

180. Install liquid soap dispenser

181. Install #18 gauge heavy duty SST shelf incl. brackets & supports

182. Install #20 gauge light duty SST shelf incl. brackets & supports

183. Install SST towel bar 19mm dia. X 500mm lg., 1 or 2 hanger(O&MA Specifications Section 10 28 13 )

184. Install vanity cabinet, 700 mm W x 490 mm D x 760 mm H w/marble top (O&MA Specifications Section 10

28 13 )

185. Install medicine cabinet, 470 mm x 870 mm H(O&MA Specifications Section 10 28 13 )"

186. Install metal toilet partition & door(O&MA Specifications Section 10 21 13 )"

187. Install metal urinal baffle(O&MA Specifications Section 10 21 13 )"

188. Install lavatory, 31mm dia, pipe support(O&MA Specifications Section 10 28 13 )"

189. Install shower bench, 300mm wide(O&MA Specifications Section 10 21 13 )"

190. Install floor water proofing for shower room & latrine(O&MA Specifications Section 10 21 13 )"

191. Install horizontal blind, 25mm aluminum slats incl. head channel, bracket and accessories

192. Install vertical blind, 89mm aluminum or cloth strips incl. bracket and accessories

193. Install kitchen wall cabinet with door 640mm~770mm H x 300 - 400mm D X 1,000mm W

194. Install Kitchen Hood wall cabinet with door 600mm W x 520 - 700mm H x 300 - 400mm D

195. Install Kitchen Hood wall cabinet with door "900mm -1,100mm W x 520 - 700mm H x 300 - 400mm D

196. Install kitchen base cabinet with door Incl. Artificial Marble Counter Top, Sink Faucet & Single bowl sink or double bowl sink 800mm~920mm H x 600mm - 650mm D x 1,000mm W

197. Install kitchen base cabinet with door Incl. Artificial Marble Counter Top, Sink Faucet & Single bowl sink or double bowl sink 900mm~1,200mm W x 800mm - 920 H x 600mm - 650mm D

198. Install kitchen counter top artificial marble counter top with back splash

Mechanical Work

1. Remove Packaged liquid chiller, air cooled or water cooled condenser type, all standard accessories, cooling capacity : any size"

2. Remove air handling unit, all type, cooling/heating coil, capacity : any size

3. Remove air cooled condensing unit, any size

4. Remove cooling tower, any size

5. Remove package air conditioning unit, standalone indoor unit, air cooled condensing outdoor unit with OA duct & piping system (cooling, heat pump type or elec. Coil include type) capacity : any size

6. Remove hot water heating boiler, or domestic hot water boiler, capacity : any size

7. Remove expansion tank, bladder or diaphragm type, capacity : any size"

8. Remove unit heater, horizontal or vertical type, any capacity

9. Remove finned tube radiator, with non elec. Control valve, any capacity

10. Remove Smoke stack with barometric damper, any size

11. Remove pump, base mounted end suction, or in-lined, capacity : any size

12. Remove all type and any size valves, fittings (gate valve, glove valve or balancing cock, strainer, check valve, air separator, flexible connection.

13. Remove steel pipe schedule#40 or copper tube & hanger, included all type valves, fittings, without insulation, any size

14. Remove pipe insulation, flexible cellular(Armaflex) or glass wool including adhesive & tape cover, any size"

15. Remove roof or wall ventilator, any type and any capacity

16. Remove bathroom exhaust fan, grille, backdraft damper

17. Remove duct accessories (grille, louver, smoke damper, smoke louver, fire damper, volume damper or turning vane, register diffuser)

18. Remove all Air duct,

19. Remove duct insulation, flexible cellular or glass wool

20. Remove sanitary ware (water closet, urinal, lavatory, service sink, kitchen sink) & accessories,

21. Remove shower, wall mounted, single lever, head,

22. Remove galvanized steel vent pipe w/ fittings, hanger

23. Remove cast iron soil pipe, any size

24. Remove sprinkler head, pendent or upright, chrome, fusible link type,

25. Remove Sprinkler pipe, including fittings, hangers, black steel schedule # 40, size : any size

26. Remove all type sensor (temperature. Thermostat, detectors)

27. Remove inside equipment concrete pad, 50mm THK.

28. Remove outside equipment concrete pad, 300mm THK.

29. Remove fan coil unit, floor mount or ceiling mounted type, any size

30. Install Sprinkler head, pendent or upright, quick response, chrome, fusible link type (O & MA Spec.21 13

13.00 10)

31. Install Sprinkler pipe, including fittings, hangers, black steel schedule # 40, size 25mm (O & MA Spec.21 13

13.00 10)"

32. Ditto, 32 mm

33. Ditto, 40 mm

34. Ditto, 50 mm

35. Ditto, 100 mm

36. Install Water closet, tank type,1 piece, vitreous china, siphon jet flushing & accessories, (American std.

2403.128-1.28 gpf) (O & MA Spec.22 00 00)"

37. Install Water closet, FV type, vitreous china, siphon jet flushing & accessories, except F.valve(American std.

2403.128-1.28 gpf) (O & MA Spec.22 00 00)"

38. Install Urinal, flush valve type, wall hung, vitreous china, except F. valve(American std. 6590.001-0.5 gpf)

(O & MA Spec.22 00 00)"

39. Install Lavatory, counter top, single lever, vitreous china, accessories, 0.5 gym (O & MA Spec.22 00 00)

40. Install Lavatory, 2 handle lever, vitreous china, accessories, wheelchair, (American std. 9141.011.020 &

6531.145) (O & MA Spec.22 00 00)

41. Install Service sink, enameled cast iron with accessories(American std. 2696.102 & 7295.252) (O & MA

Spec.22 00 00)

42. Install Kitchen sink, double bowl, faucet, accessories, 33" x 21" (O & MA Spec.22 00 00)

43. Install Kitchen sink, single bowl, accessories, 33" x 19" (American std. 14SB331900 & 6409.180)(O & MA Spec.22 00 00)

44. Install Shower, wall mounted, single lever, head,(American std. T508.507) (O & MA Spec.22 00 00)"

45. Install toilet flush valve, manual type (American std. 6047.122.002) (O & MA Spec.22 00 00)"

46. Install toilet flush valve, sensor type (American std. 606B721) (O & MA Spec.22 00 00)"

47. Install Electric water cooler, incl. piping & accessories (O & MA Spec.22 00 00)

48. Install Backflow preventer valve, w/ pressure reducing principle, bronze body, 20 mm DIA(O & MA

Spec.22 00 00)

49. Install domestic gas burner type hot water heater, 30, 000Kcal/hr or under (ΔT 100 оF, 115 GPH) (O & MA

Spec.22 00 00)

50. Ditto, 50, 000Kcal/hr (192GPH)

51. Ditto, 65, 000Kcal/hr (250 GPH)

52. Ditto, 90, 000Kcal/hr (360 GPH)

53. Install Electric domestic water heater, 100 L, 1.6 KW (O & MA Spec.23 00 00)

54. Ditto, 450 L, 4.5 KW

55. Ditto, 1000 L, 10 KW

56. Install Galvanized steel pipe, schedule#40 w/ fitting & hanger, for sewer vent pipe, 32mm DIA (O & MA

Spec.23 00 00)

57. Ditto, 40mm DIA

58. Ditto, 50mm DIA

59. Ditto, 65mm DIA

60. Ditto, 80mm DIA

61. Ditto, 100mm DIA

62. Install Cast iron soil pipe, hub type, 50 mm DIA (O & MA Spec.23 00 00)

63. Ditto, 75 mm DIA

64. Ditto, 100 mm DIA

65. Ditto, 125 mm DIA

66. Install Floor cleanout with 45 DEG. Bend, extension pipe, with Y-branch,100 mm DIA (O & MA Spec.23 00

00)

67. Ditto, 75 mm DIA

68. Ditto, 50 mm DIA

69. Install Floor drain, with P-trap, 50 mm DIA (O & MA Spec.23 00 00)

70. Ditto, 100 mm DIA

71. Install Faucet/ hose bibb, 15 mm DIA

72. Install Water hammer arrester , PDI unit "A" type

73. Ditto, "B" type

74. Ditto, "C" type

75. Install sump/submersible pump, cast iron, single stage, vertical W/control panel, water level switch and pump guide, below or equal 25GPM/1HP

76. Ditto, 75GPM, 1-1/2HP

77. Ditto, 100GPM, 2HP

78. Ditto, 150GPM, 3HP

79. Ditto, 200GPM, 5HP

80. Ditto, 300GPM, 10HP

81. Ditto, 500GPM, 15HP

82. Ditto, 800GPM, 20HP

83. Install sump/submersible pump, cast iron, single stage, explosion proof type vertical W/control panel, water level switch and pump guide, below or equal 25GPM

84. Ditto, 75GPM

85. Ditto, 100GPM

86. Ditto, 150GPM

87. Ditto, 200GPM

88. Ditto, 300GPM

89. Ditto, 500GPM

90. Ditto, 800GPM

91. Install Air handling unit, all type, cooling/heating coil, 3,400 CMH(2,000 CFM)(O & MA Spec.23 00 00)

92. Ditto, 8,500 CMH(5,000 CFM)

93. Ditto, 17,000 CMH(10,000 CFM)

94. Ditto, 25,500CMH(15,000 CFM)

95. Ditto, 34,000 CMH(20,000 CFM)

96. Ditto, 51,000CMH(30,000 CFM)

97. VAV or CAV terminal w/ hot water reheat, damper, actuator, thermostat, control valve & controller, 1,000CFM or under

98. Ditto, 1,500CFM or under

99. Ditto, 3,000CFM or under

100. Install Fan coil unit, floor mounted, 3 row coil, manual air vent, 3 speed switch, UL motor, washable filter, fresh air intake grille, 400 CFM (O & MA Spec.23 00 00)

101. Ditto, 600 CFM

102. Ditto, 800 CFM

103. Ditto, 1200 CFM

104. Install Fan coil unit, above ceiling mounted, UL motor, 400 CFM(O & MA Spec.23 00 00)

105. Ditto, 600 CFM

106. Ditto, 800 CFM

107. Ditto, 1200 CFM

108. Install Liquid filter dryer for refrigeration line (O & MA Spec.23 00 00)

109. Install Sight glass for refrigeration line(O & MA Spec.23 00 00)

110. Install Roof ventilator, direct or belt driven, 815 CFM under, 1/4" SP(O & MA Spec.23 00 00)

111. Ditto, direct driven, 2050 CFM under, 1/4" SP

112. Ditto, belt driven, 1650 CFM under, 1/4" SP

113. Ditto, belt driven, 2750 CFM under, 1/4" SP

114. Ditto, belt driven, 3500 CFM under, 1/4" SP

115. Install Wall ventilator, direct or belt driven, 1320 CFM, 1/4 HP(O & MA Spec.23 00 00)

116. Ditto, direct driven, 1983 CFM, 1/4 HP

117. Ditto, direct driven, 2900 CFM, 1/2 HP

118. Install Utility fan, centrifugal, V belt driven, pedestal, 2,000 CFM, 1 HP, 1/4" SP or under

119. Ditto, 3,600 CFM, 3/4 HP or under

120. Ditto, 4,800 CFM, 1 HP or under

121. Ditto, 15,000 CFM, 5 HP or under

122. Ditto, 20,000 CFM, 7.5 HP or under

123. Install Ceiling fan, right angle, extra quiet, 0.1" SP (static pressure), 385 CFM(O & MA Spec.23 00 00)

124. Ditto, 855 CFM

125. Install Bathroom exhaust fan, grille, backdraft damper,260 CFM(O & MA Spec.23 00 00)

126. Install Paddle blade ceiling fan, 52"blade,3-5ea bade, fan cap.: 25,500CFM,1/8 HP

127. Install Grille, louver, smoke damper, smoke louver, fire damper, volume damper or turning vane, 300mm x

300mm or under(O & MA Spec.23 00 00)

128. Ditto, 400 x 400 or under

129. Ditto, 500 x 500 or under

130. Ditto, 600 x 600 or under

131. Ditto, 700 x 700 or under

132. Ditto, 800 x 800 or under

133. Ditto, 900 x 900 or under

134. Ditto, 1000 x 1000 or under

135. Install Register or backdraft damper, 300mm x 300mm or under(O & MA Spec.23 00 00)

136. Ditto, 400 x 400 or under

137. Ditto, 500 x 500 or under

138. Ditto, 600 x 600 or under

139. Ditto, 700 x 700 or under

140. Ditto, 800 x 800 or under

141. Ditto, 900 x 900 or under

142. Ditto, 1000 x 1000 or under

143. Install Ceiling diffuser, round or square type w/damper, 200 mm neck DIA or under, aluminum(O & MA Spec.23 00 00)

144. Ditto, 250 mm DIA

145. Install Air duct, 0.5mm THK.(#26GA), without insulation(O & MA Spec.23 00 00)

146. Install Air duct, 0.6mm THK.(#24GA), without insulation

147. Install Air duct, 0.8mm THK.(#22GA), without insulation

148. Install Air duct, 1mm THK.(#20GA), without insulation

149. Install Air duct, 1mm THK.(#16GA), without insulation

150. Install Residential type range hood, 30"W, 2-speed, 210 CFM

151. Install insulated flexible duct for diffuser conn. 150 mm DIA, 3m LG

152. Ditto, 300 mm DIA, 3m LG

153. Install Dryer vent kit, flexible hose / duct, weather cap

154. Install Pipe insulation, flexible elastomeric cellular (Armaflex) or glass wool, 40mm THK. including adhesive & tape cover, 15 mm DIA(O & MA Spec.23 07 00)

155. Ditto, 20mm DIA

156. Ditto, 25mm DIA

157. Ditto, 32mm DIA

158. Ditto, 40mm DIA

159. Ditto, 50mm DIA

160. Ditto, 50 mm THK, 65mm DIA

161. Ditto, 50 mm THK, 80mm DIA

162. Ditto, 50 mm THK, 100mm DIA

163. Ditto, 50 mm THK, 125mm DIA

164. Ditto, 50 mm THK, 200mm DIA

165. Install Duct insulation, glass wool or flexible elastomeric cellular, 50 mm THK(O & MA Spec.23 07 00)

166. Install aluminum jacket on insulation, 50 mm…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .