A2_162503_REPR-DOMESTIC-WTR-DISTR-SYS-JMMT-2110-DWGS.PDF

PDF 1 MB Posted

Attached to
Repair failed/failing Domestic Water Distribution System at JMMT Incheon Air Port
Solicitation number
W91QVN19R0303
Issued by

About this file

Drawing_W91QVN19R0303

View the file

Other files

File Type Posted
W91QVN19R0303.docx DOCX document
A2_162503_REPR-DOMESTIC-WTR-DISTR-SYS-JMMT-2110_MMTL.XLSX XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATUS

REVISION

DESCRIPTION OF DRAWINGSSHT.NO.DWG.NO.REF.NO.RING NO.

S C H E D U L E O F D R A W I N G S

GENERAL

MECHANICAL

G-1

M-1

M-2

KIM, SM

MECHANICAL

1 G-1

NTS

N

S-2110

S-2113

S-2111

S-2112

S-2114

D D D

GW

D

D

D D s

GW

W

GW

HW

HW HW

W

S S

D xxx x x x x x x x x x x x D

SPRKVS

S N

P R

V S

SFHDR

SFHDR

T-2115

T-2116

THIS PROJECTTITLE SHEET & PROJECT LOCATION PLAN

G1

PROJECT LOCATION PLAN

GFEBS. NO. 162503, JMMT

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

162503

TITLE SHEET & PROJECT LOCATION PLAN

M-3

M-4

M-5

GENERAL NOTES, SCOPE OF WORK AND EQUIPMENT SCHEDULES

DISTRIBUTION SYSTEM AT JMMT

REPAIR FAILED/FAILING DOMESTIC WATER

DISTRIBUTION SYSTEM AT JMMT, KOREA

REPAIR FAILED/FAILING DOMESTIC WATER

PWO 162503,

DISTRIBUTION SYSTEM AT JMMT, KOREA

REPAIR FAILED/FAILING DOMESTIC WATER

FY19

MOVABLE CONTAINER HOUSE DETAIL

DIAGRAM FOR HYPOCHLORITE INJECTION SYSTEM

INJECTION SYSTEM

LOCATION OF MOVABLE CONTAINER HOUSE AND HYPOCHLORITE

EXISTING/REMOVAL/NEW ENLARGED PARTIAL PLANS

NOT TO SCALE

KIM, SM

MECHANICAL

M-1

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

NTS

2 6

GENERAL NOTES

A. REPAIR/MAINTENANCE (K-WORK)

AND EQUIPMENT SCHEDULES

GENERAL NOTES, SCOPE OF WORK

QTYITEM D E S C R I P T I O N

E Q U I P M E N T S C H E D U L E S

MFR. HARMSCO MODEL NO. HIF 16 OR APPROVED EQUAL.

SCOPE OF WORK

FH

FILTER CARTRIDGE HOUSING W/ FILTER

ACCESSORIES. CERTIFIED TO ANSI-NSF 61.

FOR SAFE, SECURE LID CLOSURE, AND ALL NECESSARY SAFETIES AND OPERATING

PRESSURE RATING, ALL FILTER HOUSINGS HYDROSTATICALLY TESTED, INDIVIDUAL STUDS

304 STAINLESS STEEL CONSTRUCTION, ELECTROPOLISHED FINISH, 150 PSI (10.3 BAR)

DIMENSION

CARTRIDGES

FLOW RATE

: 700 mmH x 375 mmD

: 8-19-1/2", DOUBLES

: UP TO 75 GPM

HCI

MFR. AQUS MODEL NO. Aquklor HGL003 OR APPROVED EQUAL.

HOUSE PACKAGED TYPE HYPOCHLORITE INJECTION SYSTEM

NECESSARY SAFETIES & OPERATING ACCESSORIES.

PUMPS, CHILLER, WATER FILTRATION APPARATUS, CONTROL PANEL, PIPES AND ALL

RESIDUAL CHLORINE ANALYZER, WATER SOFTENING APPARATUS, SOFT WATER SUPPLY

TANK, HYPO STORAGE TANK, HYPO DOSING UNIT, EMERGENCY SHUT-OFF VALVES, FREE

INCLUDING H.V.A.C SYSTEM, ELECTROLYZER UNIT, BRINE STORAGE

FLOOR MOUNTED, MOVABLE CONTAINER PACKAGED SYSTEM, FACTORY ASSEMBLED,

10. SALVAGEABLE MATERIALS SHALL BE RETURNED TO DPW.

AND THE LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE U.S. GOVERNMENT.

9. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION ACTIVITIES, WALLS, CEILING, ROOF, PIPE, DUCT, EQUIPMENT AND ELECTRICAL ITEMS.

NO ADDITIONAL COST TO THE GOVERNMENT, INCLUDING, BUT NOT NECESSARILY LIMITED TO ITEMS SUCH AS

NECESSARY TO ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE PROTECTION SYSTEM AT

8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS AS

REPORT SHALL BE SUBMITTED TO THE PROJECT COR FOR GOVERNMENT REVIEW AND APPROVAL.

SPECIFICATIONS FOR MISCELLANEOUS PROJECTS, KOREA. THE HVAC TESTING, ADJUSTING AND BALANCING (TAB)

ACCORDANCE WITH APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL. O & MA STANDARD TECHNICAL

7. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN STRICT

ADDITIONAL COST TO THE U.S. GOVERNMENT.

PROJECT. THE DETAILS WILL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF WORK AT NO

6. FOR O & MA PROJECTS, KOREA, OCTOBER 1, 2003 DEPARTMENT OF THE ARMY FORM AS A PART OF THIS

GOVERNMENT.

5. IF NECESSARY, CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY

BY THE CONTRACT SPECIFICATIONS.

WHICH MAY DEVIATE FROM THAT SHOWN ON CONTRACT DRAWINGS SHALL BE SUBMITTED FOR APPROVAL AS REQUIRED

FUNCTIONAL REQUIREMENTS SHOWN ON DRAWING. SHOP DRAWINGS OF THE ACTUAL PROPOSED CONTROL SYSTEM

4. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE AND WORKABLE CONTROL SYSTEM TO SATISFY ALL

TO THE CONTRACTING OFFICER FOR APPROAL.

SHALL BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED

3. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS

BY THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER.

2. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED

COMMENCING ANY CONSTRUCTION OR RENOVATION.

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO

CIVIL WORK:

2. RESTORE A/C PAVEMENT AS SHOWN ON DRAWINGS.

ACCESSORIES, AS SHOWN ON DRAWINGS.

1. REPLACE EXISTING 65MM DOMESTIC WATER PIPE INCLUDING GATE VALVES WITH VALVE BOXES, AND ALL ASSOCIATED

MECHANICAL WORK:

ELECTRICAL WORK:

ASSOCIATED ACCESSORIES FOR NEW HYPOCHLORITE INJECTION SYSTEM.

1. REPAIR EXISTING ELECTRICAL POWER SYSTEM BY INSTALLING NEW 100A SAFETY SWITCH, WIRES, CONDUITS, AND ALL

162503

DISTRIBUTION SYSTEM AT JMMT, KOREA

REPAIR FAILED/FAILING DOMESTIC WATER

FY19

NOTE:

4. CLEAN THE INSIDE OF THE EXISTING DOMESTIC WATER TANK.

ASSOCIATED ACCESSORIES, FOR PLUMBING SYSTEM AS SHOWN ON DRAWINGS.

3. REPLACE DETERIORATED EXISTING PIPES AND VALVES FROM THE MAIN PIPES TO THE EXISTING WATER TANK AND ALL

HOUSING W/ FILTER AND ALL ASSOCIATED ACCESSORIES, FOR PLUMBING SYSTEM AS SHOWN ON DRAWINGS.

2. REPAIR DETERIORATED EXISTING DOMESTIC WATER DISTRIBUTION SYSTEM BY INSTALLING NEW FILTER CARTRIDGE

AS SHOWN ON DRAWINGS.

INJECTION SYSTEM WITH MOVABLE CONTAINER HOUSE AND ALL ASSOCIATED ACCESSORIES, FOR PLUMBING SYSTEM

1. REPAIR DETERIORATED EXISTING DOMESTIC WATER DISTRIBUTION SYSTEM BY INSTALLING NEW HYPOCHLORITE

EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.

6. EXACT RATINGS AND SETTINGS OF ELECTRICAL EQUIPMENT AND DEVICES SHALL BE IN ACCORDANCE WITH MECHANICAL

SPECIFICATIONS.

NATIONAL ELECTRICAL SAFETY CODE, LIFE SAFETY CODE, UNIFIED FACILITIES CRITERIA AND CONTRACT

5. ALL ELECTRICAL WORK SHOULD BE DONE IN ACCORDANCE WITH THE CURRENT EDITIONS OF NATIONAL ELECTRICAL CODE, NECESSARY ACCESSORIES FOR H.V.A.C CONTROLS.

4. THE MECHANICAL/CONTROLS CONTRACTOR SHALL PROVIDE ALL THE WIRINGS, RELAYS, CONTROLLERS, CONDUITS AND ALL

GOVERNMENT.

3. CONTRACTOR SHALL SUBMIT HYPOCHLORITE INJECTION SYSTEM INSTALLATION SHOP DRAWINGS FOR APPROVAL BY

SPECIFICATION BY A LICENSED OR CERTIFIED INSTALLER.

2. INSTALLATION OF THE HYPOCHLORITE INJECTION SYSTEM SHALL BE IN COMPLIANCE WITH MANUFACTURER'S

MOVABLE CONTAINER HOUSE SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.

1. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE CLEARANCE, AND HYPOCHLORITE INJECTION SYSTEM

MOVABLE CONTAINER HOUSE

LOCATION OF

N

KIM, SM

MECHANICAL

3 6 M-2

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

GRAPHIC SCALE

SCALE: 1:100

0 2000 4000

M2

1:100

X X X X X X X X X X X X X X X X X X X

FNSH FL EL 7.10

MILITARY MAIL TERMINAL

EL 5.90

FNSH FL

AREA

USFK/GUARD

R W

E

AND HYPOCHLORITE INJECTION SYSTEM

LOCATION OF MOVABLE CONTAINER HOUSE

162503

DISTRIBUTION SYSTEM AT JMMT, KOREA

REPAIR FAILED/FAILING DOMESTIC WATER

FY19

ROOM

MECH

ROOM

FIRE

(7,000L x 3,000D x 3,000H)

HYPOCHLORITE INJECTION SYSTEM

MOVABLE CONTAINER HOUSE FOR

W

W

S

S

D

W

W

W

ELEC RM

H W

L

B

H W

L

A

GWL "A"

WL "A"

W100

- M3

SEE

FOR ENLARGED PLAN

M3

WL "A"

W100

S200

D450

W80

HWL "A"

HWL "B"

W80

W65

D450

SCALE = 1:100

15(N)

X X X X X

X X X X X

ROOM

MECH

ROOM

FIRE

W

W

W

W

D

W

ROOM

MECH

ROOM

FIRE

W

E

W

E ) D

E

W

E

W

E

W

N

N

ENLARGED PARTIAL PLANS

EXISTING/REMOVAL/NEW

KIM, SM

MECHANICAL

4 6 M-3

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

162503

DISTRIBUTION SYSTEM AT JMMT, KOREA

REPAIR FAILED/FAILING DOMESTIC WATER

FY19

N

GRAPHIC SCALE

SCALE: 1:50

0 1000 2000

1:50

SEE DETAIL

INJECTION SYSTEM

HOUSE & HYPOCHLORITE

MOVABLE CONTAINER

DOMESTIC WATER TANK

OF THE EXISTING

CLEAN THE INSIDE

AND PUMPS TO REMAIN (TYP.)

EXISTING PIPE W/ VALVES

VALVES TO REMAIN (TYP.)

EXISTING PIPE W/

PIPE W/ VALVES

REMOVE EXISTING

VALVE (TYP.)

NEW PISTEK

CONTROL VALVE

NEW WATER LEVEL

DOMESTIC WATER TANK

OF THE EXISTING

CLEAN THE INSIDE

AND PUMPS TO REMAIN (TYP.)

EXISTING PIPE W/ VALVES

(TYPICAL)

W/ VALVE BOX

GATE VALVE

D450

H W

L

B

H W

L

A

D450

H W

L

B

H W

L

A

M4

15(N)

15(N)

M3

M3

EXISTING/REMOVAL ENLARGED PARTIAL PLAN EXISTING/NEW ENLARGED PARTIAL PLAN2

SCALE = 1:50 SCALE = 1:50

P.O.C

P.O.C

STORAGE TANK

BRINE

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

KIM, SM

MECHANICAL

5 6 M-4

NTS

DISTRIBUTION SYSTEM AT JMMT, KOREA

REPAIR FAILED/FAILING DOMESTIC WATER

FY19

162503

M4

MOVABLE CONTAINER HOUSE DETAIL

MOVABLE CONTAINER HOUSE DETAIL

AIR LOUVER

(TYP OF 2)

AIR LOUVER, 500x500

(DARK BROWN)

ASPHALT SHINGLE

(WHITE)

VINYL SIDING

PANEL

CONTROL

WITH SKID

HYPO DOSING UNIT

CHILLER

(TYP OF 2)

WATER SOFTNER

FILTER

STORAGE TANK

HYPO

CHLORINE ANALYZER

FREE RESIDUAL

CHLORINE ANALYZER

FREE RESIDUAL

CITY WATER

D R A I N

D R A I N

FRONT VIEW BACK VIEW

RIGHT SIDE VIEWP L A N

UNIT

ELECTROLYZER

UNIT

ELECTROLYZER

SAMPLING

S A

M P

L

IN

G

IN

J E

C T

IO

N P

O

IN

T

AquKlor Hypo Dosing Unit

AquKlor HGL Series 003AquKlor HGL Series 003

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

KIM, SM

MECHANICAL

6 6 M-5

NTS

L S T T

M

DISTRIBUTION SYSTEM AT JMMT, KOREA

REPAIR FAILED/FAILING DOMESTIC WATER

FY19

162503

M5

DIAGRAM FOR HYPOCHLORITE INJECTION SYSTEM

M

M

CITY WATER

COOL WATER

WATER TANK

EXISTING

WATER TANK

EXISTING

P/P P/P

LS

VALVE

RELIEF

COLUMN

CALIBRATION

LOW

HIGH

LT

0.6m

(PE)

STORAGE TANK

HYPO

DRAIN

O

V E

R F

L O

W

A

P V

C

S C

H

OUTSIDE VENT

BLOWER A/B

M

D R

A I

N

S A

M P

L I

N G

E.D.U

L S T T

E.D.U

MM

D R

A I

N

D R

A I

N

(3kg/day)

ELECTROLYZER UNIT-B

(3kg/day)

ELECTROLYZER UNIT-A

PUMPPUMP

MM

M

LT

1.0m

(FRP)

D R

A I

N

O

V E

R F

L O

W

D R

A I

N

A

C P

V C

(TYP OF 2)

CHLORINE ANALYZER

FREE RESIDUAL

D R

A I

N

MODE MODE

LOW

HIGH

LT

0.6m

(PE)

P/P

P/P

(TYP OF 2)

(32CM/day)

WATER SOFTNER

HEAT PUMP

CONTROL PANEL

M

PI

M

M

M

M

M

PI

D R

A I

N

VALVE

RELIEF

D R

A I

N

(TYP OF 2)

SUPPLY PUMP

SOFT WATER

STORAGE TANK

SOFT WATER

HYPOCHLORITE INJECTION SYSTEM

DIAGRAM FOR

CHILLER/HEATER A/B

STORAGE TANK

BRINE

FH

1 HOUSING W/ FILTER

FILTER CARTRIDGE

MECH ROOM

65A-CPVC-WATER

(BASEMENT)

MECH ROOM

15A-CPVC

15A-CPVC

80A-CPVC-VENT

15A-CPVC

80A-CPVC-AIR

15A-CPVC

15A-PVC-(3%)15A-PVC-(3%)

15A-CPVC

A

C P

V C

A

C P

V C

A

C P

V C

A

C P

V C

A

D R

A I

N

A

D R

A I

N

15A-CPVC P:3bar-5bar 15A-CPVC 15A-CPVC15A-CPVC

A

D R

A I

N