A2_200757_REPL-ENT-DOOR-NEW_AUTO-DOOR_B209_K-16_DWG.pdf

PDF 1 MB Posted

Attached to
REPLACE ENTRANCE DOOR WITH NEW AUTOMATIC DOOR, BLDG. NO. S-209, K-16
Solicitation number
W91QVN19R0204
Issued by

About this file

Drawing_W91QVN19R0204

View the file

Other files

File Type Posted
W91QVN19R0204.docx DOCX document
A3_MMTL-ARCH_200757_REPL-ENT-DOOR-NEW_AUTO-DOOR_B209_K-16.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

1:100

01 01 T-1

SCHEDULE OF DRAWINGS

RING NO. REF. NO.REVISION STATUSDWG. NO. SHT. NO.REF. NO.

1 OF 1T - 1

RING NO. DESCRIPTION OF DRAWINGS

TITLE SHEET

DWG. NO. SHT. NO. DESCRIPTION OF DRAWINGS REVISION STATUS

TITLE SHEET

ARCHITECTURAL

A - 1

A - 2

A - 3

1 OF

KIM, Y.K.

2 OF

3 OF

200757

K-16

AUTOMATIC DOOR, BLDG. NO. S-209

REPLACE ENTRANCE DOOR WITH NEW

FY19

AUTOMATIC DOOR, BLDG. NO. S-209

REPLACE ENTRANCE DOOR WITH NEW

PWO. NO. 200757, K-16

FLOOR PLAN, SCOPE OF WORK AND GENERAL NOTES

AUTOMATIC DOOR ELEVATION, SECTIONS AND NOTE FOR D-1

AUTOMATIC DOOR ELEVATION, SECTIONS AND NOTE FOR D-2

E - 1

E - 2

ELECTRICAL

LEGEND, GENERAL NOTES AND SCOPE OF WORK

REMOVAL / POWER PLAN

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

KIM, YK

1:100

ARCHITECTURAL

200757

A-1

1 5

GENERAL NOTES

TO THE PROJECT CONTRACT.

ARCHITECTURAL SCOPE OF WORK AT NO ADDITIONAL COST

NOVEMBER 2015) WILL BE UTILIZED TO ACCOMPLISH THE

O & MA STANDARD DETAILED DRAWINGS, 2014 (DATED 30

6. THE ARCHITECTURAL STANDARD DRAWINGS SHOWN IN THE

WALL - - - - U=0.092 (R=10.86)

ROOF - - - - U=0.052 (R=19.23)

7. MAXIMUM U-FACTORS AND R-VALUE HEAT TRANSMISSION

COMMENCING ANY CONSTRUCTION OR RENOVATION.

ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO

1. THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING

AS DIRECTED BY THE CONTRACTING OFFICER.

THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS

OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED BY

2. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT

AND SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS

SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE

MAY NOT MATCH FIELD CONDITIONS EXACTLY,

3. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS

INSTALLATION.

APPROVED BY THE C.O.R. BEFORE FABRICATION AND

ALL DOOR AND WINDOW DETAILS AND DRAWING SHALL BE

THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR

SPECIFICATIONS AND MANUFACTURES INSTRUCTIONS.

5. ALL DOORS AND WINDOWS SHALL BE FABRICATED I.A.W.

SHOP DRAWINGS FOR APPROVAL BY GOVERNMENT.

4. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION

K-16

AUTOMATIC DOOR, BLDG. NO. S-209

REPLACE ENTRANCE DOOR WITH NEW

FY19

GENERAL NOTES

FLOOR PLAN, SCOPE OF WORK AND

SCOPE OF WORK (ARCHITECTURAL)SCOPE OF WORK (ARCHITECTURAL)

2. PATCH AND PAINT AROUND NEW DOORS.2. PATCH AND PAINT AROUND NEW DOORS.

SCALE : 1 / 100

EXST. FLOOR PLAN

A1-

16,400 3,100 1,200

8,000 2,000

30,700

3,100 3,245

6,345 27,420

SYSTEMS.(2-EA, DOUBLE DOORS)

1. REPLACE EXST. ENTRANCE DOORS WITH NEW AUTOMATIC DOOR

THIS JOB AREA

D1

D2

DOORS.

AUTOMATIC SLIDING

2EA. ELECTRICAL

DOUBLE DOORS WITH NEW

REPLACE EXST. 2EA.

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

KIM, YK

1:100

ARCHITECTURAL

200757

A-2

2 5

SX - Slide/Swing Panels

Unit Width

ThresholdSO - Swingout Sidelite

Pivot

C351 Jamb

Pivot

Safety Beam

(13)

1/2"

Jamb

C351

C2906

3/8" (9)

C335

2" (51)

(44)

1 3/4"

1/4" (6)

C365

2" (51) 2 1/2" (63)

C365

Exterior

C335 C2906

1/4" (6)

Door shown in open position

1/2"

3/4"(19)

(6)

1/4"

Exterior

D o o r

P a n e l

H ig h t

F a c e p la t c c e s n e l

C336

Muntin

C337

C337

4" (102)

F. Floor

1/2"

C336

Muntin

C337

C343-1

NOT TO SCALE

EXTERIOR FRONT ELEVATION

NOT TO SCALE

HORIZONTAL SECTION

NOT TO SCALE

VERTICAL SECTION1

A2A1

A2A1

A2A1

MECHANISM

BREAKOUT

INTERLOCKING

CONTINUOUS

* NOTE FOR AUTOMATIC SLIDING DOOR NO. 1

K-16

AUTOMATIC DOOR, BLDG. NO. S-209

REPLACE ENTRANCE DOOR WITH NEW

FY19

SECTIONS AND NOTES FOR D-1

AUTOMATIC DOOR ELEVATION,

HORTON AUTOMATICS

KEEP MOVING

AUTOMATIC DOOR

Panel

Slide/Swing

SX

HORTON AUTOMATICS

KEEP MOVING

AUTOMATIC DOOR

Panel

Slide/Swing

SX

BY HORTON

PHOTO BEAMS

BY HORTON

PHOTO BEAMS

Panel

Sidelite

O

Panel

Sidelite

O

2,450

2,450

EMERGENCY BREAKOUT

24mm Pair Glass 24mm Pair Glass 24mm Pair Glass 24mm Pair Glass

24mm Pair Glass 24mm Pair Glass 24mm Pair Glass 24mm Pair Glass

OPERATOR

ELECTRIC

BELT DRIVE

SERIES 2000B

- MANUAL SLIDE WHEN POWER OFF

- MAIN SUPPLY : 120VAC / 60Hz / 15AMP

- OPENING SPEED : 150mm-1,000mm/SEC.

FOR EMERGENCY

- EMERGENCY EGRESS : SLIDING DOORS BREAKOUT

- DOOR OPERATION : MOTION DETECTOR & TOUCH SENSOR

- FRAME MATERIAL : DARK BRONZE FINISHED ALUMINUM

- CONTROL SYSTEM : MICRO-PROCESSOR MASTER CONTROL

- DOOR TYPE : TYPE 110

- OPERATION SERIES : HORTON-2000

* OR APPROVED EQUAL.

- MANUFACTURE : HORTON AUTOMATICS

- GLASS : THK.24mm, PAIR GLASS

- OPEN SIZE : 935 x 2,145

- UNIT SIZE : 2,450 x 2,298

- TYPE : AUTOMATIC SLIDING DOOR

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

KIM, YK

1:100

ARCHITECTURAL

200757

A-3

3 5

NOT TO SCALE

EXTERIOR FRONT ELEVATION1

A3A1

K-16

AUTOMATIC DOOR, BLDG. NO. S-209

REPLACE ENTRANCE DOOR WITH NEW

FY19

SECTIONS AND NOTES FOR D-2

AUTOMATIC DOOR ELEVATION,

8mm Tempered Glass

8mm Tempered Glass

HORTON AUTOMATICS

KEEP MOVING

AUTOMATIC DOOR

Panel

Slide/Swing

SX

8mm Tempered Glass

8mm Tempered Glass

HORTON AUTOMATICS

KEEP MOVING

AUTOMATIC DOOR

Panel

Slide/Swing

SX

8mm Tempered Glass

8mm Tempered Glass8mm Tempered Glass

8mm Tempered Glass

BY HORTON

PHOTO BEAMS

BY HORTON

PHOTO BEAMS

Panel

Sidelite

O

Panel

Sidelite

O

8mm Tempered Glass

8mm Tempered Glass

HORTON AUTOMATICS

KEEP MOVING

AUTOMATIC DOOR

Panel

Slide/Swing

SX

8mm Tempered Glass

8mm Tempered Glass

HORTON AUTOMATICS

KEEP MOVING

AUTOMATIC DOOR

Panel

Slide/Swing

SX

8mm Tempered Glass

8mm Tempered Glass8mm Tempered Glass

8mm Tempered Glass

BY HORTON

PHOTO BEAMS

BY HORTON

PHOTO BEAMS

Panel

Sidelite

O

Panel

Sidelite

O

NOT TO SCALE

HORIZONTAL SECTION

NOT TO SCALE

VERTICAL SECTION2

A3A1

A3A1

OPERATOR

ELECTRIC

LINEAR DRIVE

SERIES 2000

MECHANISM

BREAKOUT

INTERLOCKING

CONTINUOUS

* NOTE FOR AUTOMATIC SLIDING DOOR NO. 2

Door shown in open position

1/2"

3/4"(19)

(6)

1/4"

Exterior

D o o r n l

H ig h t

F a c e p la t c c e n e l

C336

Muntin

C337

C337

4" (102)

F. Floor

1/2"

C336

Muntin

C337

C343-1

SX - Slide/Swing Panels

Unit Width

ThresholdSO - Swingout Sidelite

Pivot

C351 Jamb

Pivot

Safety Beam

(13)

1/2"

Jamb

C351

C2906

3/8" (9)

C335

2" (51)

(44)

1 3/4"

1/4" (6)

C365

2" (51) 2 1/2" (63)

C365

Exterior

C335 C2906

1/4" (6)

1,032

2,650

EMERGENCY BREAKOUT

1,032

2,650

- MANUAL SLIDE WHEN POWER OFF

- MAIN SUPPLY : 120VAC / 60Hz / 15AMP

- OPENING SPEED : 150mm-1,000mm/SEC.

FOR EMERGENCY

- EMERGENCY EGRESS : SLIDING DOORS BREAKOUT

- DOOR OPERATION : MOTION DETECTOR & TOUCH SENSOR

- FRAME MATERIAL : DARK BRONZE FINISHED ALUMINUM

- CONTROL SYSTEM : MICRO-PROCESSOR MASTER CONTROL

- DOOR TYPE : TYPE 110

- OPERATION SERIES : HORTON-2000

* OR APPROVED EQUAL.

- MANUFACTURE : HORTON AUTOMATICS

- GLASS : THK.8mm, TEMPERED GLASS

- OPEN SIZE : 1,032 x 2,145

- UNIT SIZE : 2,650 x 2,308

- TYPE : AUTOMATIC SLIDING DOOR

E-1

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

U, YM

N.T.S

LEGEND, GENERAL NOTES AND

SCOPE OF WORKS

SHEET OF

ELECTRICAL

GENERAL NOTES

1.

2.MOUNTING HEIGHTS ABOVE FLOOR SHALL BE AS FOLLOW UNLESS OTHERWISE

NOTED ON THE DRAWING.

LIGHTING FIXTURE SEE LIGHTING FIXTURE SCHEDULE

PANELBOARD SEE SPECIFICATION

SAFETY SWITCH 1524mm TO CENTER OF THE ENCL

1105mm TO CENTER OF THE ENCL

MOTOR CONTROLLER 1524mm TO CENTER OF THE ENCL

3.

4.

6.THE SOIL RESISTANCE TO GROUND FOR THE ELECTRICAL AND COMMMUNICATION

SYSTEMS SHALL BE 25 OHMS OR LESS. THE SOIL RESISTANCE TEST SHALL BE

7.

5.

CONDUCTED BY THE CONTRACTOR TO OBTAIN THE REQUIRED SOIL RESISTANCE.

INDICATEDS 2 #12AWG IN 16C

INDICATEDS 3 #12AWG IN 16C

INDICATEDS 4 #12AWG IN 16C

A GREATER NUMBER OF WIRES ARE INDICATED AS FOLLOWS;

1219mm TO CENTER OF THE ENCLWALL SWTICH

CONDUIT UNLESS OTHERWISE INDICATED.

ALL EQUIPMENT CONTROL WIRING SHALL BE #14 AWG. "TW" IN 16C

AND LOCATION OF THE F/A ANTENNA WITH THE CENTRAL FIRE DEPARTMENT

THE CONTRACTOR SHALL SUBMIT THE SHOP DRAWING FOR THE MOUNTING

TO TRANSMIT THE ALARM RADIO SIGNAL WAVE WITHOUT ANY OBSTRUCTION.

DETAIL OF THE F/A ANTENNA, AND COORDINATE THE MOUNTING HEIGHT

F/A EQUIPMENT IN THE CENTRAL FIRE DEPARTMENT.

THE EQUIPMENT SHOULD BE COMPATIBLE WITH THE MAIN EXISTING

12.

13.

14.

10.

11.

8.

9.

15.

SINGLE POLE TOGGLE SWITCH, 15A-125V

L E G E N D

LIGHTING

WIRING

POWER

INTERIOR

S

SYMBOL DESCRIPTION

DESCRIPTION

DESCRIPTION

T

J

THERMOSTAT (UNDER MECH. ITEM)

JUNCTION BOX

SYMBOL

SYMBOL

F FAN MOTOR (UNDER MECH. ITEM)

SAFETY SWITCH3-WAY SWITCH, 15A-125V

AND GOVERNMENT INSTALLED

GOVERNMENT FURNISHED

GFGI

WEATHERPROOFWP

LA LIGHTNING ARRESTER

EXPLOSIONPROOFEP

DISTRIBUTIONDIST

GROUND FAULT PROTECTIONGFP

A AMPERE

AC ALTERNATING CURRENT

AF/AT AMPERE FRAME/AMPERE TRIP

AWG AMERICAN WIRE GAUGE

BC BARE COPPER

BLDG BUILDING

BRKR BREAKER

C CONDUIT

CB CIRCUIT BREAKER

CKT CIRCUIT

CONN CONNECTION

CT CURRENT TRANSFORMER

DET(S) DETAIL(S)

DIAG DIAGRAM

DISC DISCONNECT

DWG(S) DRAWING(S)

EA EACH

EM EMERGENCY

ENCL ENCLOSURE

EXST EXISTING

F/A FIRE ALARM

FL FLOOR

FLUOR FLUORESCENT

FXTR FIXTURE

GEN GENERATOR

GND GROUND

HP HORSE POWER

HZ HERTZ

INCAND INCANDESCENT

INSTL INSTALLATION

J-BOX JUNCTION BOX

K KILO

KV KILO VOLT

KVA KILO VOLT AMPERE

LTG LIGHTING

MAG MAGNETIC

MAX MAXIMUM

MIN MINIMUM OR MINUTE

MTG MOUNTING

NO NUMBER

O/H OVER HEAD

PH PHASE

PNLBD PANELBOARD

PRIM PRIMARY

PWR POWER

Q'TY QUANTITY

RCPT RECEPTACLE

REQ'D REQUIRED

SCHED SCHEDULE

SEC SECONDARY

SPEC SPECIFICATION

STD STANDARD

SW SWITCH

TEL TELEPHONE

TYP TYPICAL

U/G UNDERGROUND

V VOLT

VA VOLT AMPERE

W WATT

W/ WITH

XFMR TRANSFORMER

& AND

CABNET TYPE, RATED WATT ON LTG SCHEDULE

LED LIGHTING FIXTURE, WALL MOUNTED OR UNDER

ON LTG SCHEDULE, WET LOCATION

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

FAULT PROTECTED TYPE

DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDED

PANELBOARD

3S

TYPE OF MTG ON LTG SCHEDULE

EXTERIOR LED LIGHTING FIXTURE, RATED WATT &

TYPE

DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDING

ABBREVIATION

THE COTNRACTOR SHALL SUBMIT A SHOP DRAWING OF HVAC SYSTEM

IN ACCORDANCE WITH SEQUENCE OF OPERATION INDICATED ON THE

MECHANICAL DRAWINGS.

ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES 2-#12AWG

WIRES IN 16C CONDUIT UNLESS OTHERWISE INDICATED.

THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR

ELECTRICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.

CATV BEFORE CONSTRUCTION.

CONTRACTOR SHALL COORDINATE WITH AREA MP, DO IMO, SIGNAL BRIGADE,

AND GOVERNMENT ACCEPTANCE.

PANELBOARD DOOR, REQUIRED BEFORE FINAL BUILDING INSPECTION

CONTRACTOR SHALL MAKE CIRCUIT CHARTS AND ATTACH THEM TO

FIRE CODE AND SPECIFICATIONS.

OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,

ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS

OR RENOVATION.

CONDITION AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFING ALL EXISTING

FIXTURE A MINIMUM DISTANCE OF 458mm.

FIRE ALARM DETECTORS SHALL BE LOCATED TO CLEAR ANY LIGHTING

AUXILIARY

DESCRIPTIONSYMBOL

L

PHOTOCELL

WP

FAULT PROTECTED TYPE, WEATHER PROOF

DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDED

TYPE WITH PLUG

SINGLE RECEPTACLE, 3P-4W-30A-125/250V, GROUNDING

TYPE WITH PLUG

SINGLE RECEPTACLE, 3P-4W-50A-125/250V, GROUNDING

L

L

ON LTG SCHEDULE

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

ON LTG SCHEDULE

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

W/EMERGENCY BATTERY UNIT

L

W/EMERGENCY UNIT TYPE

QUADPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDING

ON LTG SCHEDULE

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

ON LTG SCHEDULE

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

L

L

UNITS.

CERTIFICATE FROM MANUFACTURER FOR LED LIGHTING FIXTURES AND POWER

CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE 10YEARS WARRANTY

16.

AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.

TO THEIR ORIGINAL CONDITION AND OPERATION DURING

ALL DAMAGED AREA INCLUDING SODDING, UTILITIES, STRUCTURES

THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING

LIGHTING CONTACTOR, SEL SW (H-O-A)

THE MANUFACTURER AND MODEL OF NEW BUILDING TRANSMITTER EQUIPMENT

IN THE CENTRAL FIRE DEPARTMENT.

THE EQUIPMENT SHOULD BE TESTED WITH THE RECEIVING SYSTEM(D21)

SHALL BE COORDINATED WITH THE CENTRAL FIRE DEPARTMENT.

RECEPTACLE

CEILING OR CONCEALED IN NEW WALL.

ALL WIRING SHALL BE CONCEALED ABOVE CEILING WHEN THE ROOM HAS

FLEXIBLE CONDUIT W/CONNECTORS

C CONTROL CIRCUIT

HOMERUN CIRCUIT TO PANELBOARD

FMCP

FTR

ANTENNA

F

TELEPHONE OUTLET

ADDRESSABLE FA MANUAL PULL STATION

WP

F M

TTB

FIRE ALARM/MASS NOTIFICATION CONTROL PANEL

TELEPHONE TERMINAL BOARD

MOUNTED TYPE

F/A & MASS NOTIFICATION SPEAKER "WP" WALL

STROBES

WALL MOUNTED SPEAKER /COMBO. (FA+MNS)VISUAL

CONNECTION

BUILDING TRANSMITTER UNIT FOR FIRE ALARM

SYSTEM

F FIRE ALARM SYSTEM CIRCUIT

WIRING FOR TELEPHONE LINET

BRANCH CIRCUIT, EXPOSED ON CEILING OR WALL

WIRING CONCEALED IN THE CEILING AND WALL

F/M

3D 3-WAY DIMMING SWITCH, 15A-125V

SCOPE OF WORK

A. REPAIR / MANTENANCE (K)

1. POWER SUPPLY WIRING FOR AUTOMATIC DOORS.

K-16

AUTOMATIC DOOR, BLDG. NO. S-209

REPLACE ENTRANCE DOOR WITH NEW

FY19

200757

2.

AS SHOWN DRAWING.

PEPLACE EXISTING 2(TWO)EA LIGHTING FIXTURES WITH NEW

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

ENGINEERING DIVISON, DPW, USAG-YONGSAN

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

1:100

200757

E-2

5 5

K-16

AUTOMATIC DOOR, BLDG. NO. S-209

REPLACE ENTRANCE DOOR WITH NEW

FY19

L

SCALE : 1 / 100

U, YM

ELECTRICAL

J

J

POWER UNIT

CONVERTER & ACCESSORIES AS REQUIRED,LISTED

W/BUILT-JN PHOTOCELL,WET LOCATION TYPE,WITH

WALL MOUNTED LED LIGHT FIXTURE,1PH,120V,22W,

JUNCTION BOX FOR AUTOMATIC DOORS

CONVERTER & ACCESSORIES AS REQUIRED (NS-4A)

DIODE(LED)FIXTURE,1PH,120V,45W,UL,LISTED

CEILING RECESSED MOUNTED LIGHT EMITTING

EXIST PANEL "B"

2#12 & 1#12(G) IN 16C

CONN TO "B"-14,"B"-15

THIS JOB AREA

L

SCALE : 1 / 100

REMOVAL PLAN

REMOVAL AND NEW POWER PLAN

NEW POWER PLAN

200757_REPL-ENT-DOOR-NEW AUTO-DOOR_B209_K-16_DWG_ARCH
200757_REPL-ENT-DOOR-NEW AUTO-DOOR_B209_K-16_DWG-T-01-Default-000
200757_REPL-ENT-DOOR-NEW AUTO-DOOR_B209_K-16_DWG-A-01-Default-000
200757_REPL-ENT-DOOR-NEW AUTO-DOOR_B209_K-16_DWG-A-02-Default-000
200757_REPL-ENT-DOOR-NEW AUTO-DOOR_B209_K-16_DWG-A-03-Default-000
200757_REPL-ENT-DOOR-NEW AUTO-DOOR_B209_K-16_DWG-E-1
200757_REPL-ENT-DOOR-NEW AUTO-DOOR_B209_K-16_DWG-E-2

File details come from the government source that posted it.