Remove, Clean and Dispose of Portable Latrines, Grease Traps, Septic Tanks and Lift Stations for Osan Air Base

ATTACHMENT 1

ESTIMATED CONTRACT WORKLOAD DATA

ITEM

NAME

ESTIMATED QUANTITY

1
Clean and maintain septic tanks
12
Each
2
Clean and maintain grease traps
16
Each
3
Clean and maintain portable toilets
33
Each
4
Dispose of human waste
2,422,300
Liters
5
Dispose of waste grease
423,600
Liters
6
Clean and Dispose of sludge and sand from lift station
134
Cubic Meter

ATTACHMENT 2

PORTABLE TOILET ESTIMATED WORKLOAD DATA

Facility Number Capacity in Liters Max. Capacity Allowed

Base Wide 250,000 70%

ATTACHMENT 3

GREASE TRAP ESTIMATED WORKLOAD DATA

Facility NumberCapacity in LitersMax. Capacity Allowed
46110,00090%
4732,00090%
5072,50090%
7338,00090%
7374,00090%
7751,00090%
82830090%
9172,00090%
9241,00090%
9656,00090%
9751,20090%
1313 (inside)50090%
1313 (outside)6,00090%
14706,50090%
17412,00090%
177450090%
See note below5,00090%
Total58,500

ATTACHMENT 4

SEPTIC TANK ESTIMATED WORKLOAD DATA

Facility Number Capacity in Liters Max. Capacity Allowed 123 3,000 90%

13313,00090%
1639,00090%
17323,00090%
3519,00090%
3584,00090%
5045,00090%

1501 7,500 90% 1696 10,000 90% 1789 10,000 90% 2118 2,000 90%

2678 (35th ADA)5,00090%
See note below: 5,00090%
Total105,500

Note: Contractor shall be required to service those septic tanks not yet identified as requiring service. Contractor shall notify the COR in the event a septic tank not yet identified requires servicing more than 3 times during any month. The COR will initiate a modification to include this requirement on the normal schedule. This may be because of construction, disconnection, etc. Capacity is estimated from historical data.

ATTACHMENT 5

LIFT STATION ESTIMATED WORKLOAD DATA

Facility Number Cubic Meters Max. Capacity Allowed 420 8 As need

4323As need
4363As need
6591As need
8141As need
82412As need
8391As need
8421As need
8764As need
11301As need
11601As need
11801As need
12157As need

1232 5 As need

13562As need
170622As need
17151 As need

1715 Sludge Tank 39 As need 1819 9 As need 2427 4 As need 2435 7 As need

24371As need
Total134