REVISION STATUS
1 OF 1T - 1
DESCRIPTION OF DRAWINGS
TITLE SHEET
DESCRIPTION OF DRAWINGS REVISION STATUS
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
1:100 01 01
TITLE SHEET
194344
T-1
SCHEDULE OF DRAWINGS
NO.
RING
NO.
SHTEET
NO.
RING
NO.
REF.
NO.
DWG.
NO.
SHEET
NO.
REF.
NO.
DWG.
ELECTRIC
E - 1
E - 2
E - 3
LIGHTING PLAN(B#256)
1 OF
2 OF
3 OF LIGHTING FIXTURE DETAIL
LEGNED,GENERAL NOTES AND SCOPE OF WORK
BLDG. NO. S-256
REPAIR DETERIORATED LIGHTS WITH NEW LED
PWO. NO. 194344, K-16
K-16, WITH NEW LED.BLDG.NO.S-256
REPAIR DETERIORATED LIGHTS
FY18
U,YM
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
E-1
LEGEND, NOTES, SCOPE OF WORK
1.
SCOPE OF WORKGENERAL NOTES
1.
2.MOUNTING HEIGHTS ABOVE FLOOR SHALL BE AS FOLLOW UNLESS OTHERWISE
NOTED ON THE DRAWING.
LIGHTING FIXTURE SEE LIGHTING FIXTURE SCHEDULE
PANELBOARD SEE SPECIFICATION
SAFETY SWITCH 1524mm TO CENTER OF THE ENCL
RECEPTACLE,TELEPHONE OUTLET 305mm TO CENTER OF THE ENCL
MOTOR CONTROLLER 1524mm TO CENTER OF THE ENCL
1676mm TO CENTER OF THE ENCL
2286mm TO CENTER OF BELL
ON CEILINGDETECTOR
1372mm TO CENTER OF STATIONMANUAL PULL STATION
INDICATEDS 2 #12AWG IN 16C
INDICATEDS 3 #12AWG IN 16C
INDICATEDS 4 #12AWG IN 16C
A GREATER NUMBER OF WIRES ARE INDICATED AS FOLLOWS;
1219mm TO CENTER OF THE ENCLWALL SWTICH
F/A &MNS CONTROL
COMBO. SPEAKER & STROBE
3.
ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES 2-#12AWG
WIRES IN 16C CONDUIT UNLESS OTHERWISE INDICATED.
CEILING.
ALL WIRING SHALL BE CONCEALED ABOVE CEILING WHEN THE ROOM HAS
FIRE CODE AND SPECIFICATIONS.
OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,
ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS 4.
UNITS.
CERTIFICATE FROM MANUFACTURER FOR LED LIGHTING FIXTURES AND POWER
CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE 10YEARS WARRANTY 5.
AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.
TO THEIR ORIGINAL CONDITION AND OPERATION DURING
THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING
ALL DAMAGED AREA INCLUDING UTILITIES, STRUCTURES
6.
SINGLE POLE TOGGLE SWITCH, 15A-125V
L E G E N D
LIGHTING
WIRING
POWER
INTERIOR
S
SYMBOL DESCRIPTION
DESCRIPTION
DESCRIPTION
T
J
THERMOSTAT (UNDER MECH. ITEM)
JUNCTION BOX
SYMBOL
SYMBOL
F FAN MOTOR (UNDER MECH. ITEM)
SAFETY SWITCH3-WAY SWITCH, 15A-125V
CABNET TYPE, RATED WATT ON LTG SCHEDULE
LED LIGHTING FIXTURE, WALL MOUNTED OR UNDER
ON LTG SCHEDULE, WET LOCATION
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
FAULT PROTECTED TYPE
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDED
PANELBOARD
3S
TYPE OF MTG ON LTG SCHEDULE
EXTERIOR LED LIGHTING FIXTURE, RATED WATT &
TYPE
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDING
AUXILIARY
DESCRIPTIONSYMBOL
L
PHOTOCELL
WP
FAULT PROTECTED TYPE, WEATHER PROOF
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDED
TYPE WITH PLUG
SINGLE RECEPTACLE, 3P-4W-30A-125/250V, GROUNDING
TYPE WITH PLUG
SINGLE RECEPTACLE, 3P-4W-50A-125/250V, GROUNDING
L
L
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
W/EMERGENCY BATTERY UNIT
L
TYPE
QUADPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDING
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
L
L
LIGHTING CONTACTOR, SEL SW (H-O-A)
FLEXIBLE CONDUIT W/CONNECTORS
C CONTROL CIRCUIT
HOMERUN CIRCUIT TO PANELBOARD
FMCP
FTR
ANTENNA
F
TELEPHONE OUTLET
ADDRESSABLE FA MANUAL PULL STATION
WP
F M
TTB
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
TELEPHONE TERMINAL BOARD
MOUNTED TYPE
F/A & MASS NOTIFICATION SPEAKER "WP" WALL
STROBES
WALL MOUNTED SPEAKER /COMBO. (FA+MNS)VISUAL
CONNECTION
BUILDING TRANSMITTER UNIT FOR FIRE ALARM
SYSTEM
F FIRE ALARM SYSTEM CIRCUIT
WIRING FOR TELEPHONE LINET
BRANCH CIRCUIT, EXPOSED ON CEILING OR WALL
WIRING CONCEALED IN THE CEILING AND WALL
F/M
3D 3-WAY DIMMING SWITCH, 15A-125V
AND GOVERNMENT INSTALLED
GOVERNMENT FURNISHED
WEATHERPROOF
LIGHTNING ARRESTER
EXPLOSIONPROOF
DISTRIBUTION
GROUND FAULT PROTECTION
AMPERE
ALTERNATING CURRENT
AMPERE FRAME/AMPERE TRIP
AMERICAN WIRE GAUGE
BARE COPPER
BUILDING
BREAKER
CONDUIT
CIRCUIT BREAKER
CIRCUIT
CONNECTION
CURRENT TRANSFORMER
DETAIL(S)
DIAGRAM
DISCONNECT
DRAWING(S)
EACH
EMERGENCY
ENCLOSURE
EXISTING
FIRE ALARM
FLOOR
FLUORESCENT
FIXTURE
GENERATOR
GROUND
HORSE POWER
HERTZ
INCANDESCENT
INSTALLATION
JUNCTION BOX
KILO
KILO VOLT
KILO VOLT AMPERE
LIGHTING
MAGNETIC
MAXIMUM
MINIMUM OR MINUTE
MOUNTING
NUMBER
OVER HEAD
PHASE
PANELBOARD
PRIMARY
POWER
QUANTITY
RECEPTACLE
REQUIRED
SCHEDULE
SECONDARY
SPECIFICATION
STANDARD
SWITCH
TELEPHONE
TYPICAL
UNDERGROUND
VOLT
VOLT AMPERE
WATT
WITH
TRANSFORMER
AND
ABBREVIATION
194344
U, YM
DRAWING.
EXIST WHERE AS REQUIRED ON THIS CONTRACT
WIRING FOR EMERGENCY LIGHT SETS IF NOT
CONTRACTOR SHOULD INSTALL ADDITIONAL POWER 2.
NOTE:
1.
CONTRACTOR'S RESPONSIBILITY.
THE FURNITURE MOVEMENT WHICH IS ASSOCIATED WITH THE
ON LTG SCHEDULE (NS-4a)
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
W/EMERGENCY UNIT (NS-4b)
SURFACE MOUNTED (NS-3)
LED EXIT LIGHTING FIXTURE, WALL OR CEILING
K-16
WITH NEW LED
REPAIR DETERIORATEDLIGHTS
FY18
A. REPAIR/MAINTENANCE ( K )
NEW(LED) AS SHOWN ON THE DRAWING
REPLACE DETERIORATED EXISTING LIGHTING FIXTURES, WITH
3. PAINT IF REQUIRE, DEPENDING ON THE WORK.
GFGI
WP
LA
EP
DIST
GFP
A
AC
AF/AT
AWG
BC
BLDG
BRKR
C
CB
CKT
CONN
CT
DET(S)
DIAG
DISC
DWG(S)
EA
EM
ENCL
EXST
F/A
FL
FLUOR
FXTR
GEN
GND
HP
HZ
INCAND
INSTL
J-BOX
K
KV
KVA
LTG
MAG
MAX
MIN
MTG
NO
O/H
PH
PNLBD
PRIM
PWR
Q'TY
RCPT
REQ'D
SCHED
SEC
SPEC
STD
SW
TEL
TYP
U/G
V
VA
W
W/
XFMR
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
1:100 E-2
SCALE:1/100
LIGHTING PLAN
U, YM
194344
K-16
WITH NEW LED
REPAIR DETERIORATED LIGHTS
FY18
LIGHTING PLAN
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L R L R L R L R L R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L R
L
R
L
R
L R
L
L R
L
L
R
L
R
L
R
L
R
L
L
R
L L L L L L L L L
LLLLLLLLL
+ L L
L s s s s s s s s s s s s s s s s s s s s s
ADDITIONAL LEGEND(THIS SHEET ONLY)
:L s
EMITTING DIODE(LED) FIXTURE.
CEILING SURFACE MOUNTED LIGHT
:L R
EMITTING DIODE(LED) FIXTURE.
CEILING RECESSED MOUNTED LIGHT
m m
308mm
NS-4a & 4bNS-3
FIXTURE, 1PH, 120V, 45W, WITH CONVERTER & ACCESSORIES
CEILING RECESSED MOUNTED LIGHT EMITTING DIODE (LED)
WALL OR CEILING SURFACE MOUNTED LIGHT EMITTING
(MAX INPUT), BATTERY BACK-UP WITH BATTERY
DIODE(LED) EXIT LIGHT FIXTURE, 1PH, 120V, 4.99W
NS-8
NS-5a & 5b m m 1220m m
0m m
FIXTURE, 1PH, 120V, 50W, WITH CONVERTER & ACCESSORIES
CEILING RECESSED MOUNTED LIGHT EMITTING DIODE (LED)
WALL
WALL SURFACE MOUNTED LIGHT EMITTING DIODE (LED)
NS-7
WALL MOUNTED LED LIGHT FIXTURE, 1PH, 120V, 22W,
FIXTURE, 1PH, 120V, 18W, WITH CONVERTER &
(NS-4a) & WITH EM UNIT (NS-4b) AS REQUIRED (NS-5a) & WITH EM UNIT (NS-5b) AS REQUIRED
245mm
254mm
FIXTURE, 1PH, 120V, 18W, WITH CONVERTER & ACCESSORIES,
CEILING SURFACE MOUNTED LIGHT EMITTING DIODE (LED)
WET LOCATION SHOWER LIGHT TRIM, UL LISTED POWER UNIT
NS-9
NS-6a & 6b m m 1220m m
0m m
CEILING RECESSED MOUNTED LIGHT EMITTING DIODE (LED)
FIXTURE, 1PH, 120V, 50W, WITH CONVERTER (DIMMING CONTROL)
FIXTURE, 1PH, 120V, 25W, WITH CONVERTER & ACCESSORIES
CEILING RECESSED MOUNTED LIGHT EMITTING DIODE (LED)
NS-11
m m m m
216mm
NS-10a & 10b
(NS-10a) & WITH EM UNIT (NS-10b) AS REQUIRED
CEILING SURFACE/PENDANT MOUNTED LIGHT EMITTING DIODE
(LED) FIXTURE, 1PH, 120V, 45W, UL LISTED, WITH CONVERTER
NS-12a & NS-12b
UNDERCABINET LED LIGHT FIXTURE
1PH, 120V, 18W, CONVERTER AND ACCESSORIES
NS-13
AS REQUIRED
OUTDOOR TYPE, 1PH, 120V, 22W W/CONVERTER &
ACCESSORIES AS REQUIRED
WET LOCATION TYPE, WITH CONVERTER &
ACCESSORIES AS REQUIRED
CEILING SURFACE MOUNTED LED LIGHT FIXTURE,
U, YM
194344
LIGHTING FIXTURE DETAIL
LIGHTING FIXTURE DETAIL
E-3
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
NTS
K-16
WITH NEW LED.BLDG.NO.S-256
REPAIR DETERIORATED LIGHTS
FY18
CHARGER, SINGLE FACE AS REQUIRED
AS REQUIRED
& ACCESSORIES (NS-6a) & WITH EM UNIT (NS-6b)
ACCESSORIES AS REQUIRED
AS REQUIRED
AND ACCESSORIES (NS-12a) AND EM UNIT(NS-12b) AS REQUIRED