Attachment 1 01_Daegu_Pricing Schedule.xls
XLS spreadsheet 182 KB Posted
- Solicitation number
- W91QVN18R0058
About this file
Pricing Schedule for Daegu
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP.pdf | ||
| Attachment 3_Drawing for Daegu_PCC Reinforced Pavement.pdf | ||
| Attachment 3_Drawing for Kunsan.pdf | ||
| Attachment 1 02_Kunsan_Pricing Schedule.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Basic Option
| BIDDING SCHEDULE | |||||
| PROJECT TITLE: IDIQ Contract for Repair and Construction of Concrete Pavements, USAG-Daegu. | |||||
| DESCRIPTION: The Contractor shall furnished all labor, materials, equipment and transportation for repair and construction of the concrete pavements at all US forces installations in USAG Daegu in accordance with the specifications and drawings. | |||||
| Contract Period: Basic Option Year of 12 Months | |||||
| Item No. | Description | Q'TY | Unit | Unit Price | Total Amount |
| 0001 Repair | |||||
| 0001AA | Replace 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-203) | 1,000 | SM | ||
| 0001AB | Replace 75mm thick asphalt concrete(AC) pavement on base course (Standard drawing, C-103) | 1,000 | SM | ||
| 0001AC | Apply milling 50mm thick asphalt concrete(AC) pavement (Standard drawing, C-206) | 500 | SM | ||
| 0001AD | Overlay 50mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 0001AE | Overlay 75mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 0001AF | Replace non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 0001AG | Replace reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 0001AH | Replace 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 0001AJ | Replace concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 0001AK | Replace 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 0001AL | Raise concrete manhole cover (Standard drawing, C-908) | 5 | EA | ||
| 0001AM | Raise gate valve box cover (Standard drawing, C-825) | 5 | EA | ||
| 0001AN | Replace 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 0001AP | Replace 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 0001AQ | Replace 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 0001AR | Replace 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 0001AS | Replace 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 0001AT | Replace 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 0001AU | Replace 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 0001AV | Replace 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 0001AW | Replace 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 0001AX | Replace 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 0001AY | Replace 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 0001AZ | Replace concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 0001BA | Replace 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 0001BB | Replace 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 0001BC | Replace 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 0001BD | Replace steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| 0001BE | Spot sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 0001BF | Solid sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 0001BG | Remove 150mm~ 300mm diameter tree | 10 | EA | ||
| 0001BH | Replant 150mm ~ 300mm diameter tree | 10 | EA | ||
| 0001BJ | Remove pavement marking | 20 | SM | ||
| 0001BK | Excavate/grade subgrade or earth | 100 | CM | ||
| Estimated Total Amount for Item 0001: | |||||
| 0002 Construction | |||||
| 0002AA | Construct 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-101~C-102) | 1,000 | SM | ||
| 0002AB | Construct non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 0002AC | Construct reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 0002AD | Apply pavement marking (Standard drawing, C-401~C-402) | 600 | SM | ||
| 0002AE | Install synthetic type wheel stops (Standard drawing, C-501) | 100 | EA | ||
| 0002AF | Construct 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 0002AG | Construct concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 0002AH | Construct 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 0002AJ | Install 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 0002AK | Install 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 0002AL | Install 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 0002AM | Install 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 0002AN | Install 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 0002AP | Construct 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 0002AQ | Construct 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 0002AR | Construct 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 0002AS | Construct 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 0002AT | Construct 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 0002AU | Construct 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 0002AV | Construct concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 0002AW | Construct 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 0002AX | Construct 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 0002AY | Construct 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 0002AZ | Install steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| Estimated Total Amount for Item 0002: | |||||
| Grand Total (Won) |
&L&8* U. S. Origin Materials ** Government Furnished Materials&CBase - &P
1st Option
| BIDDING SCHEDULE | |||||
| PROJECT TITLE: IDIQ Contract for Repair and Construction of Concrete Pavements, USAG-Daegu. | |||||
| DESCRIPTION: The Contractor shall furnished all labor, materials, equipment and transportation for repair and construction of the concrete pavements at all US forces installations in USAG Daegu in accordance with the specifications and drawings. | |||||
| Contract Period: 1st Option Year of 12 Months | |||||
| Item No. | Description | Q'TY | Unit | Unit Price | Total Amount |
| 1001 Repair | |||||
| 1001AA | Replace 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-203) | 1,000 | SM | ||
| 1001AB | Replace 75mm thick asphalt concrete(AC) pavement on base course (Standard drawing, C-103) | 1,000 | SM | ||
| 1001AC | Apply milling 50mm thick asphalt concrete(AC) pavement (Standard drawing, C-206) | 500 | SM | ||
| 1001AD | Overlay 50mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 1001AE | Overlay 75mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 1001AF | Replace non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 1001AG | Replace reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 1001AH | Replace 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 1001AJ | Replace concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 1001AK | Replace 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 1001AL | Raise concrete manhole cover (Standard drawing, C-908) | 5 | EA | ||
| 1001AM | Raise gate valve box cover (Standard drawing, C-825) | 5 | EA | ||
| 1001AN | Replace 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 1001AP | Replace 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 1001AQ | Replace 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 1001AR | Replace 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 1001AS | Replace 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 1001AT | Replace 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 1001AU | Replace 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 1001AV | Replace 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 1001AW | Replace 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 1001AX | Replace 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 1001AY | Replace 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 1001AZ | Replace concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 1001BA | Replace 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 1001BB | Replace 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 1001BC | Replace 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 1001BD | Replace steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| 1001BE | Spot sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 1001BF | Solid sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 1001BG | Remove 150mm~ 300mm diameter tree | 10 | EA | ||
| 1001BH | Replant 150mm ~ 300mm diameter tree | 10 | EA | ||
| 1001BJ | Remove pavement marking | 20 | SM | ||
| 1001BK | Excavate/grade subgrade or earth | 100 | CM | ||
| Estimated Total Amount for Item 1001: | |||||
| 1002 Construction | |||||
| 1002AA | Construct 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-101~C-102) | 1,000 | SM | ||
| 1002AB | Construct non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 1002AC | Construct reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 1002AD | Apply pavement marking (Standard drawing, C-401~C-402) | 600 | SM | ||
| 1002AE | Install synthetic type wheel stops (Standard drawing, C-501) | 100 | EA | ||
| 1002AF | Construct 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 1002AG | Construct concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 1002AH | Construct 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 1002AJ | Install 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 1002AK | Install 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 1002AL | Install 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 1002AM | Install 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 1002AN | Install 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 1002AP | Construct 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 1002AQ | Construct 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 1002AR | Construct 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 1002AS | Construct 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 1002AT | Construct 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 1002AU | Construct 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 1002AV | Construct concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 1002AW | Construct 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 1002AX | Construct 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 1002AY | Construct 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 1002AZ | Install steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| Estimated Total Amount for Item 1002: | |||||
| Grand Total (Won) |
&L&8* U. S. Origin Materials ** Government Furnished Materials&C1st Option - &P
2nd Option
| BIDDING SCHEDULE | |||||
| PROJECT TITLE: IDIQ Contract for Repair and Construction of Concrete Pavements, USAG-Daegu. | |||||
| DESCRIPTION: The Contractor shall furnished all labor, materials, equipment and transportation for repair and construction of the concrete pavements at all US forces installations in USAG Daegu in accordance with the specifications and drawings. | |||||
| Contract Period: 2nd Option Year of 12 Months | |||||
| Item No. | Description | Q'TY | Unit | Unit Price | Total Amount |
| 2001 Repair | |||||
| 2001AA | Replace 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-203) | 1,000 | SM | ||
| 2001AB | Replace 75mm thick asphalt concrete(AC) pavement on base course (Standard drawing, C-103) | 1,000 | SM | ||
| 2001AC | Apply milling 50mm thick asphalt concrete(AC) pavement (Standard drawing, C-206) | 500 | SM | ||
| 2001AD | Overlay 50mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 2001AE | Overlay 75mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 2001AF | Replace non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 2001AG | Replace reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 2001AH | Replace 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 2001AJ | Replace concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 2001AK | Replace 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 2001AL | Raise concrete manhole cover (Standard drawing, C-908) | 5 | EA | ||
| 2001AM | Raise gate valve box cover (Standard drawing, C-825) | 5 | EA | ||
| 2001AN | Replace 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 2001AP | Replace 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 2001AQ | Replace 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 2001AR | Replace 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 2001AS | Replace 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 2001AT | Replace 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 2001AU | Replace 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 2001AV | Replace 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 2001AW | Replace 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 2001AX | Replace 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 2001AY | Replace 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 2001AZ | Replace concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 2001BA | Replace 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 2001BB | Replace 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 2001BC | Replace 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 2001BD | Replace steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| 2001BE | Spot sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 2001BF | Solid sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 2001BG | Remove 150mm~ 300mm diameter tree | 10 | EA | ||
| 2001BH | Replant 150mm ~ 300mm diameter tree | 10 | EA | ||
| 2001BJ | Remove pavement marking | 20 | SM | ||
| 2001BK | Excavate/grade subgrade or earth | 100 | CM | ||
| Estimated Total Amount for Item 2001: | |||||
| 2002 Construction | |||||
| 2002AA | Construct 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-101~C-102) | 1,000 | SM | ||
| 2002AB | Construct non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 2002AC | Construct reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 2002AD | Apply pavement marking (Standard drawing, C-401~C-402) | 600 | SM | ||
| 2002AE | Install synthetic type wheel stops (Standard drawing, C-501) | 100 | EA | ||
| 2002AF | Construct 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 2002AG | Construct concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 2002AH | Construct 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 2002AJ | Install 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 2002AK | Install 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 2002AL | Install 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 2002AM | Install 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 2002AN | Install 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 2002AP | Construct 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 2002AQ | Construct 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 2002AR | Construct 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 2002AS | Construct 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 2002AT | Construct 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 2002AU | Construct 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 2002AV | Construct concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 2002AW | Construct 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 2002AX | Construct 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 2002AY | Construct 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 2002AZ | Install steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| Estimated Total Amount for Item 2002: | |||||
| Grand Total (Won) |
&L&8* U. S. Origin Materials ** Government Furnished Materials&C2nd Option - &P
3rd Option
| BIDDING SCHEDULE | |||||
| PROJECT TITLE: IDIQ Contract for Repair and Construction of Concrete Pavements, USAG-Daegu. | |||||
| DESCRIPTION: The Contractor shall furnished all labor, materials, equipment and transportation for repair and construction of the concrete pavements at all US forces installations in USAG Daegu in accordance with the specifications and drawings. | |||||
| Contract Period: 3rd Option Year of 12 Months | |||||
| Item No. | Description | Q'TY | Unit | Unit Price | Total Amount |
| 3001 Repair | |||||
| 3001AA | Replace 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-203) | 1,000 | SM | ||
| 3001AB | Replace 75mm thick asphalt concrete(AC) pavement on base course (Standard drawing, C-103) | 1,000 | SM | ||
| 3001AC | Apply milling 50mm thick asphalt concrete(AC) pavement (Standard drawing, C-206) | 500 | SM | ||
| 3001AD | Overlay 50mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 3001AE | Overlay 75mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 3001AF | Replace non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 3001AG | Replace reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 3001AH | Replace 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 3001AJ | Replace concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 3001AK | Replace 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 3001AL | Raise concrete manhole cover (Standard drawing, C-908) | 5 | EA | ||
| 3001AM | Raise gate valve box cover (Standard drawing, C-825) | 5 | EA | ||
| 3001AN | Replace 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 3001AP | Replace 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 3001AQ | Replace 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 3001AR | Replace 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 3001AS | Replace 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 3001AT | Replace 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 3001AU | Replace 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 3001AV | Replace 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 3001AW | Replace 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 3001AX | Replace 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 3001AY | Replace 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 3001AZ | Replace concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 3001BA | Replace 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 3001BB | Replace 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 3001BC | Replace 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 3001BD | Replace steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| 3001BE | Spot sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 3001BF | Solid sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 3001BG | Remove 150mm~ 300mm diameter tree | 10 | EA | ||
| 3001BH | Replant 150mm ~ 300mm diameter tree | 10 | EA | ||
| 3001BJ | Remove pavement marking | 20 | SM | ||
| 3001BK | Excavate/grade subgrade or earth | 100 | CM | ||
| Estimated Total Amount for Item 3001: | |||||
| 3002 Construction | |||||
| 3002AA | Construct 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-101~C-102) | 1,000 | SM | ||
| 3002AB | Construct non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 3002AC | Construct reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 3002AD | Apply pavement marking (Standard drawing, C-401~C-402) | 600 | SM | ||
| 3002AE | Install synthetic type wheel stops (Standard drawing, C-501) | 100 | EA | ||
| 3002AF | Construct 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 3002AG | Construct concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 3002AH | Construct 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 3002AJ | Install 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 3002AK | Install 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 3002AL | Install 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 3002AM | Install 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 3002AN | Install 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 3002AP | Construct 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 3002AQ | Construct 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 3002AR | Construct 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 3002AS | Construct 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 3002AT | Construct 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 3002AU | Construct 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 3002AV | Construct concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 3002AW | Construct 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 3002AX | Construct 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 3002AY | Construct 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 3002AZ | Install steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| Estimated Total Amount for Item 3002: | |||||
| Grand Total (Won) |
&L&8* U. S. Origin Materials ** Government Furnished Materials&C3rd Option - &P
4th Option
| BIDDING SCHEDULE | |||||
| PROJECT TITLE: IDIQ Contract for Repair and Construction of Concrete Pavements, USAG-Daegu. | |||||
| DESCRIPTION: The Contractor shall furnished all labor, materials, equipment and transportation for repair and construction of the concrete pavements at all US forces installations in USAG Daegu in accordance with the specifications and drawings. | |||||
| Contract Period: 4th Option Year of 12 Months | |||||
| Item No. | Description | Q'TY | Unit | Unit Price | Total Amount |
| 4001 Repair | |||||
| 4001AA | Replace 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-203) | 1,000 | SM | ||
| 4001AB | Replace 75mm thick asphalt concrete(AC) pavement on base course (Standard drawing, C-103) | 1,000 | SM | ||
| 4001AC | Apply milling 50mm thick asphalt concrete(AC) pavement (Standard drawing, C-206) | 500 | SM | ||
| 4001AD | Overlay 50mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 4001AE | Overlay 75mm thick asphalt concrete(AC) on asphalt concrete(AC) pavement (Standard drawing, C-204) | 1,000 | SM | ||
| 4001AF | Replace non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 4001AG | Replace reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 4001AH | Replace 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 4001AJ | Replace concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 4001AK | Replace 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 4001AL | Raise concrete manhole cover (Standard drawing, C-908) | 5 | EA | ||
| 4001AM | Raise gate valve box cover (Standard drawing, C-825) | 5 | EA | ||
| 4001AN | Replace 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 4001AP | Replace 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 4001AQ | Replace 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 4001AR | Replace 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 4001AS | Replace 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 4001AT | Replace 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 4001AU | Replace 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 4001AV | Replace 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 4001AW | Replace 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 4001AX | Replace 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 4001AY | Replace 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 4001AZ | Replace concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 4001BA | Replace 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 4001BB | Replace 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 4001BC | Replace 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 4001BD | Replace steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| 4001BE | Spot sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 4001BF | Solid sodding on unpaved area (Standard drawing, C-701) | 100 | SM | ||
| 4001BG | Remove 150mm~ 300mm diameter tree | 10 | EA | ||
| 4001BH | Replant 150mm ~ 300mm diameter tree | 10 | EA | ||
| 4001BJ | Remove pavement marking | 20 | SM | ||
| 4001BK | Excavate/grade subgrade or earth | 100 | CM | ||
| Estimated Total Amount for Item 4001: | |||||
| 4002 Construction | |||||
| 4002AA | Construct 75mm thick asphalt concrete(AC) pavement, 150mm thick base course and 280mm thick subbase course (Standard drawing, C-101~C-102) | 1,000 | SM | ||
| 4002AB | Construct non reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course (Standard drawing, C-103~C-106) | 1,000 | SM | ||
| 4002AC | Construct reinforced 285mm thick portland cement concrete(PCC) pavement and 330mm thick base course | 1,000 | SM | ||
| 4002AD | Apply pavement marking (Standard drawing, C-401~C-402) | 600 | SM | ||
| 4002AE | Install synthetic type wheel stops (Standard drawing, C-501) | 100 | EA | ||
| 4002AF | Construct 175mm width x 450mm height concrete curb (Standard drawing, C-303) | 100 | LM | ||
| 4002AG | Construct concrete curb and gutter (Standard drawing, C-303) | 100 | LM | ||
| 4002AH | Construct 100mm thick concrete sidewalk and 100mm thick base course (Standard drawing, C-305) | 100 | SM | ||
| 4002AJ | Install 150mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 4002AK | Install 200mm diameter polyvinyl chloride(PVC) drainage pipe | 100 | LM | ||
| 4002AL | Install 300mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 4002AM | Install 450mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 4002AN | Install 600mm diameter reinforced concrete pipe(RCP) drainage | 100 | LM | ||
| 4002AP | Construct 300mm width x 450mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 4002AQ | Construct 450mm width x 600mm depth concrete covered concrete ditch (Standard drawing, C-1001) | 50 | LM | ||
| 4002AR | Construct 300mm width x 450mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 4002AS | Construct 450mm width x 600mm depth concrete open ditch (Standard drawing, C-1005) | 50 | LM | ||
| 4002AT | Construct 300mm width x 450mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 4002AU | Construct 450mm width x 600mm depth steel grating covered concrete ditch (Standard drawing, C-1002) | 50 | LM | ||
| 4002AV | Construct concrete surface inlet including steel grating cover (Standard drawing, C-1008) | 10 | EA | ||
| 4002AW | Construct 1200mm x 1200mm x 1800mm depth concrete drain manhole including manhole cover and frame (Standard drawing, C-1009) | 10 | EA | ||
| 4002AX | Construct 1200mm width concrete step and 100mm thick base course with steel handrail (Standard drawing, C-302) | 10 | LM | ||
| 4002AY | Construct 1200mm width, 100mm thick concrete sidewalk and 100mm thick base course with one side of steel handrail (Standard drawing, C-307) | 20 | LM | ||
| 4002AZ | Install steel guard rail and metal post (Standard drawing, C-507~C-508) | 400 | LM | ||
| Estimated Total Amount for Item 4002: | |||||
| Grand Total (Won) |
&L&8* U. S. Origin Materials ** Government Furnished Materials&C4th Option - &P
File details come from the government source that posted it.