Attachment_2_Revised_Drawings.pdf
PDF 2 MB Posted
- Attached to
- Window Replacement Bldg 4305 Yongsan
- Solicitation number
- W91QVN-17-R-0229
About this file
Revised Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_1_Revised_SOW.pdf | ||
| W91QVN-17-R-0229-0002_Solicitation_Amendment.pdf | ||
| W91QVN-17-R-0229-0001_Solicitation_Amendment.pdf | ||
| W91QVN-17-R-0229_Solicitation.pdf | ||
| W91QVN-17-R-0229_Submittal_Register.xlsx | XLSX spreadsheet | |
| W91QVN-17-R-0229_Drawings.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FILE NAME
D
2 3
C
4 5
A
B
S E
O U
L ,K
O R
E A
YU AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S
W
L A
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
S C H E D U L E O F D R A W I N G S
DESCRIPTION OF DRAWINGS
NO
RING
NO
SHEET
STATUS
REVISION
DESCRIPTION OF DRAWINGS
NO
RING
NO
SHEET
STATUS
REVISION
A P
P R
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E M
A R
K
NUMBER
IDENTIFICATION
SHEET
Sheet of
IM
C
O M
D E
P A
R T
M E
N T O
F T
H E A
R M
Y
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U S
A G -Y
O N
G S
A N
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
A P
P R
O V
E D B
Y
P L
O T S
C A
L E
C K
D B
Y
D E
S
IG
N E
D B
Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E D
A T
E
U S
IN
G A
G E
N C
Y
P W
O /P
R O J E
C T N
O
D A
T E
I S
O
A
U
G
G-001
T I T
L E
H
E E
T
G
D G
N
ARCHITECTURAL
162802AE101.DGN
162802AE102.DGN
FILE NAME
FLOOR PLANS, SCOPE OF WORK AND GENERAL NOTES
K I
M
Y
K
TITLE SHEET
162802G-001.DWG1
GENERAL
PWO. NO. 300000162802, YONGSAN, KOREA
BLDG. NO.S-4305
REPLACE FAILING WINDOWS
Y O
N G
S A
N
K O
R E
A
B L
D G
N O S -4
R E
P L
A C
E F
A
IL
IN
G W
IN
D
O W
S
F Y
WINDOW DESCRIPTIONS AND NOTES
D
S C
R I P
T I O
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R I P
T I O
N A
P P
R
D A
T E
D E
S I G
N
B Y
D A
T E
S I Z
E
P L
T
C
A L
E
F I
N
M E
I S
S
T E
I M
C O
M
D E
P A
R T
M E
F
R
M Y
E N
G I N
E E
R I
I V I S I O
N
U S
A G
Y O
N G
S A
N
D I R
E C
T O
R A
P
B L
W
R K
S
I
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
C K
P W
O
P R
O J
E
U S I
E N
C Y
Sheet of
AE101
COMMENCING ANY CONSTRUCTION OR RENOVATION.
ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO
1. THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING
AS DIRECTED BY THE CONTRACTING OFFICER.
THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS
OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED BY
2. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT
AND SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS
SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE
MAY NOT MATCH FIELD CONDITIONS EXACTLY,
3. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS
INSTALLATION.
APPROVED BY THE C.O.R. BEFORE FABRICATION AND
ALL DOOR AND WINDOW DETAILS AND DRAWING SHALL BE
THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR
SPECIFICATIONS AND MANUFACTURES INSTRUCTIONS.
5. ALL DOORS AND WINDOWS SHALL BE FABRICATED I.A.W.
GENERAL NOTES
SHOP DRAWINGS FOR APPROVAL BY GOVERNMENT.
4. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION
TO THE PROJECT CONTRACT.
ARCHITECTURAL SCOPE OF WORK AT NO ADDITIONAL COST
NOVEMBER 2015) WILL BE UTILIZED TO ACCOMPLISH THE
O & MA STANDARD DETAILED DRAWINGS, 2014 (DATED 30
6. THE ARCHITECTURAL STANDARD DRAWINGS SHOWN IN THE
WALL - - - - U=0.092 (R=10.86)
ROOF - - - - U=0.052 (R=19.23)
7. MAXIMUM U-FACTORS AND R-VALUE HEAT TRANSMISSION
SCOPE OF WORK
A E
A. REPAIR/ MAINTENANCE WORK
G E
N E
R
T E
S
F L
O
A N
S
S C
O
01 02
K I
M
Y
K
ARCHITECTURAL
SCALE : 1 / 200AE101
EXST. FIRST FLOOR PLAN
SCALE : 1 / 200AE101
EXST. SECOND FLOOR PLAN
W1 W1 W1 W1 W1 W1 W1
W2
W2
W2
W3W4
W4
W4
W5
W6W6 W6 W6
W7
W7
W7
W8
W8
W8
W8
W8
W8
W8
W8
W8
W8
W8
W8
W8
W8 W8 W8
W8
W8
W8
W8
W8 W8 W8 W8
W8
W8 W8 W8
W8
W8
W8
W8
W8
W8
W8
W8
W8
W8 W8 W8
W8
W10
W9 W9 W9 W9 W9
W11 W11 W11 W11 W11 W11 W11 W11 W11 W11 W11 W11
W12
W13 W14
Y O
N G
S A
N
K O
R E
A
B L
D G
N O
S
R E
P L
A
I L I
N
D O
W S
F Y
A/C.
WINDOW TYPE
LEAVE EXST.
WINDOW TYPE A/C
REMOVE EXST.
1. REPLACE EXISTING WINDOWS WITH NEW AS SHOWN ON DWG.
SURFACES.
EXISTING ROOF
DO NOT TOUCH
2. PATCH AND PAINT AROUND NEW WINDOWS MATCHING TO EXISTING.
Yong.K.Kim Typewritten Text
3. FOR THIS PROJECT, THE PROJECT MANAGER SHOULD BE A FIRST CLASS ACHITECTURAL
ENGINEER LICENSE AND SHOULD MEET OTHER REQUIREMENTS AS SPECIFIED ON KOREA-WIDE
GENERAL CONSTRUCTION (INCLUDING NEW CONSTRUCTION WORK UNDER $ 750K) MULTIPLE
AWARD INDEFINITE DELIVERY INDEFINITE QUANTITY (MA IDIQ) DOCUMENT.
S C
R I P
T I O
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R I P
T I O
N A
P P
R
D A
T E
D E
S I G
N
D A
T E
S I Z
E
P L
A L
E
F I
M E
I S
S
T E
I M
C O
M
D E
P A
R T
M E
M Y
E N
G I N
E E
R I
V I S I O
N
U S
A G
Y O
N G
S A
N
D I R
E C
T O
R A
B L
R K
S
I
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
C
P W
O
P R
O J
E
U S I
E N
C Y
Sheet of
A E
02 02
K I
M
Y
K
NOT TO SCALEAE102
Y O
N G
S A
N
K O
R E
A
B L
D G
N O
S
R E
P L
A
I L I
N
D O
W S
F Y
AE102
WINDOW DESCRIPTIONS
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* THK.25mm WINDOW BLIND
* INSULATING CLEAR GLASS UNIT (6+6+6)
W1
* W1 - SIZE : 2,400 x 1,600 x THK.130mm
W I N
D
S C
R I P
T I O
T E
S
600 1200 600
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
W2
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
W3
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
W4
* W4 - SIZE : 1,200 x 1,100 x THK.130mm
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
W5
* W2 - SIZE : 850 x 1,550 x THK.130mm
* W3 - SIZE : 1,000 x 800 x THK.130mm
1100 1100
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* W5 - SIZE : 800 x 1,100 x THK.130mm
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* THK.25mm WINDOW BLIND
* INSULATING CLEAR GLASS UNIT (6+6+6)
W6
* W6 - SIZE : 1,000 x 1,000 x THK.130mm
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
W7
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
W8
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
W9
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND * THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* W10 - SIZE : 800 x 1,600 x THK.130mm
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* THK.25mm WINDOW BLIND
* INSULATING CLEAR GLASS UNIT (6+6+6)
* W11 - SIZE : 2,300 x 1,500 x THK.130mm
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6) * INSULATING CLEAR GLASS UNIT (6+6+6)
WEATHERSTRIPPING AND WINDOW FASTENER
WITH ALUM. FRAME W/INSECT SCREEN,
* ALUMINUM SASH SLIDING WINDOW
* INSULATING CLEAR GLASS UNIT (6+6+6)
* W14 - SIZE : 1,700 x 1,150 x THK.130mm
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* THK.25mm WINDOW BLIND
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* W7 - SIZE : 1,100 x 1,950 x THK.130mm * W8 - SIZE : 1,100 x 1,950 x THK.130mm
* W9 - SIZE : 760 x 1,950 x THK.130mm
* W12 - SIZE : 1,400 x 1,900 x THK.130mm
WITH ALUM. FRAME
* ALUMINUM SASH FIXED WINDOW
* W13 - SIZE : SEE ABOVE
650 NOTES
OFFICER PRIOR TO COMMENCING WORK.
INSTRUCTIONS APPROVED BY THE CONTRACTOR
HARDWARE SCHEDULE AND MANUFACTURER'S
IN ACCORDANCE WITH SPECIFICATIONS,
1. ALL WINDOWS SHALL BE FABRICATED
BEFORE FABRICATION AND INSTALLATION.
BY THE CONTRACTING OFFICER
THE DRAWINGS SHALL BE APPROVED
DRAWINGS FOR ALL WINDOWS.
2. THE CONTRACTOR SHALL PREPARE SHOP
LAMINATED PAIR GLASS
* ALL WINDOW GLASSES SHALL BE THK.6mm
* DO NOT TOUCH EXISTING ROOF SURFACES.
Yong.K.Kim Text Box
Yong.K.Kim Typewritten Text
3. SPECIAL NOTE FOR WINDOW GLAZING AND FRAMES :
PROVIDE WINDOW PRODUCT INCLUDING GLAZING AND FRAME
DESIGNED IN ACCORDANCE WITH ASTM F2248.
WINDOW FRAME SIZE AND GLAZING CONSTRUCTION WILL BE IN
ACCORDANCE WITH MANUFACTURER'S PRODUCT STANDARD.
4. WINDOW PRODUCT INSTALLATION SHALL BE IN ACCORDANCE
WITH UFC 4-010-01 DoD MINIMUM ANTITERRORISM STANDARDS
FOR BUILDINGS.
Yong.K.Kim Text Box
| 2017-08-24T14:07:51+0900 | |
| KIM.YONG KYU.1288268459 |
| 2017-08-24T14:55:00+0900 | |
| CHANG.PYONG SANG.1401610487 |
| 2017-08-24T16:22:20+0900 | |
| CHANG.PYONG SANG.1401610487 |
| 2017-08-24T16:09:57+0900 | |
| SONG.TO PIN.1289759588 |
| 2017-08-24T14:10:30+0900 | |
| KIM.YONG KYU.1288268459 |
| 2017-08-24T14:15:20+0900 | |
| HAN.CHIN HO.1276924890 |
| 2017-08-24T14:55:17+0900 | |
| CHANG.PYONG SANG.1401610487 |
| 2017-08-24T14:12:00+0900 | |
| KIM.YONG KYU.1288268459 |
| 2017-08-24T14:15:50+0900 | |
| HAN.CHIN HO.1276924890 |
| 2017-08-24T14:55:33+0900 | |
| CHANG.PYONG SANG.1401610487 |
File details come from the government source that posted it. Updated .