H3_Solicitation_W91QVN-17-R-0224_Attachment_No._1_-_DRAWINGS.pdf
PDF 3 MB Posted
- Attached to
- Replace HVAC System with Heat Pump System
- Solicitation number
- W91QVN-17-R-0224
About this file
W91QVN-17-R-0224 Attachment No. 01 - Drawings
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I S
O
A
N T
S
Sheet of
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
P L
O T S
C A
L E
S E
O U
L ,K
O R
E A
F
IL
E N
A M
E
IS
S
U E D
A T
E
IM
C
O M
D E
P A
R T
M E
N T O
F T
H E A
R M
Y
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U S
A G -Y
O N
G S
A N
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
E D B
Y
C K
D B
Y
P W
O /P
R O J E
C T N
O
U S
IN
G A
G E
N C
Y
G
D G
N
G-001
DESCRIPTION OF DRAWINGS
NO
RING
NO
SHEET
GENERAL
S C H E D U L E O F D R A W I N G S
STATUS
REVISION
DESCRIPTION OF DRAWINGS
NO
RING
NO
SHEET
STATUS
REVISION
FILE NAME
TITLE SHEET
GFEBS. NO. 155079, YONGSAN
FILE NAME
155079G-001.DGN
T
IT
L E S
H E
E T
K I
M
MECHANICAL
155079M-001.DGN
155079MD101.DGN
155079MH101.DGN
155079G-002.DGN2
2 OF 2 PROJECT LOCATION PLAN
J
U L
Y
J
U L
Y
WITH HEAT PUMP SYSTEM, B2556
REPLACE FAILING H.V.A.C SYSTEM
Y O
N G
S A
N
K O
R E
A
W
IT
H H
E A
T P
U M
P S
Y S
T E
M
B
R E
P L
A C
E F
A
IL
IN
G H .V .A .C S
Y S
T E
M
F Y
C H
A N
G
P
K I
M
J
D
4 OF 4155079M-501.DGN6
ELECTRICAL
1 OF 1155079EP101.DGN7 EXIST/NEW ELECTRICAL POWER PLAN
GENERAL NOTE, SCOPE OF WORK (MECH./ELEC./ARCH.)
EXIST/REMOVAL H.V.A.C ENLARGED PLAN & EQUIPMENT SCHEDULES
EXIST/NEW H.V.A.C ENLARGED PLAN
MECHANICAL DETAILS
PYEONGTAEK
KUNSAN
L O C A T I O N M A P
NOT TO SCALE
KWANGJU
INCHON
S E A
W E S T
MUNSAN
DAEGU
CHINHAE
WAEGWAN
BUSAN
45 1
E A S T S E A
DAEJEON
OSAN 1
CHUNCHON
UIJONGBU
DONGDUCHEON
SEOUL
TONGYOUNG
MOKPO
POHANG
AREA II, YONGSAN
THIS PROJECT
YS-N2
YS-N1
13,633,786.41' N 1,056,091.79' E Elev. 68.86'
13,634,403.76' N
1,056,125.06' E
Elev. 95.19'
13,636,212.56' N
1,054,323.85' E
Elev. 61.74'
ALPHA
2200 2300 2400 25002600
GREEN HOUSE
DI
VI
SI
ON
R O
A D
LODGE COMPLEX
DRAGON HILL
T-363
8 4
T411
SITE
MEMORIAL
3 4 3 4
SIGNS
X C O R P S B L V D .
loading arealoading arealoading area
TOWER
B O I L
E R
O M
Driving Range
GREEN
HOUSE
TOWER
K E P C
O
ACC
ACC
A M
M O
S T
O R
A G E
OIL
STORAGE
G A
R A
G E
S T
O R
A G
E
ACC
LORING VILLAGE
BLACK HAWK AREA
H-264
MUSEUM
G U
A
T
W E
R
81338
1488 1490
STREET
BATES
BOWMAN STREET
2079 2
SIGNAL
ANTENNA
TOWER
E L
L S
O N
S
T R
R E
T
S T
R E
E T
EILER ST.
1531 1530
EILER STREET
E L
L S
O N
S
T R
E E
T1529
245 244 246
T
2604 2
F L O R E S
STREET
G A
IN
E S
S T
R E E T
P A
N P
O
R R
E T
ITAEWONNO STREET
T106
Baseba ll
Field
BEARD STREET
21113
ECHO
ALLEN STREET
S
C L
A G
G A
V E
N U
E
CAMP STREET
15 1350
1407 1408
1370 14
ARMOR LOOP
150215
11 1519
1522180 157
P-1-1
F A R R E L L
A V
E N
U E
E
IL
E R
S176
S175
1619 1621
STREET
DUNN
16021627
1656 1655
160016001599
27632710
ELLSON STRRET
2 2308
1ST CORPS BLVD.
15501495
R O
A D
A R
M Y
T
H
149414
5 ELLSON STREET
1ST CORPS BLVD.
01382
123112
2215 2322
T
H A
R M
Y R
O A
D
G U
L L
U
V
E N
U E
PARADE GROUND
4 2
2475 2661
62474
24802480
UN BOULEVARD
23652361
23642364
HAWKA STREET
2386239
IT'AEWONNO STREET
CAVALRY DIVISION ROAD
1ST
S200
S
S273 Basketball
Court
PEDESTRIAN
OVERPASS
S
ROK WAR MEMORIAL
13,635,305.56' N
1,056,298.58' E Elev. 189.07'
13,635,725.01' N 1,054,417.36' E Elev. 61.80'
GAS
STATI
ON
X C O R P S B L V D .
BLDG
ROK
253127
JENSEN STREET
1ST MARINE DIVISION ROAD
4431 4433
A
T
H
41664164
4156 4158
4160 4162
MOOR ST.
M
ATTA
AVENUE
GUARD
HOUSE
KENNEL
H
IV
IS
IO
N7133
STATION
PUMP
SEWAGE
ARTI
LLERY
LOOP
4 7
A V
E N
U E
W I N S
T E
R A
V E
N U
E
7050 7
A V
E N
U E
S T
O V
E S
ROAD
DIV
ISI
ON
3RD
T E
L E F
O
E N
U E
X C O R P S B L V D .
TOWER
S T
O R
A G
E2 T
H
D
IV
IS
IO
N
14913
IS
IO
N
A D
04915
V A
U G
H N
IS
A D
STATIONPUMP
#1
#2
#3
#4
IM
HOFF
T
ANKS
S-
Swimming Pool
S-360
4333 4336
S-500
T-502
43354332
44144411
A R
M Y
R O
A D
Soccer Field
IX CORPS B
LVD.
A R
Y
A D
T
H
4216 4
01 4730
ROSE STREET
L A
V A
T O
R Y
IS
A
D
0 5
HAMMOND
SOFTBALL FIELD
R O
D G
E
E N
U E
S T R E E T
71247
WALL W/FENCE
X
C
O R P S
B L
V D
ARTI
LLERY
LOOP
0 7
DIVISION
3RD
ROAD
BOULEVARD
CORPS
W A
L K
E
N U
E
83 7
WILBUR STREET
5107 5108
17 4419 4424
STREET
LYNDON
40354
A D
0 4726
4457 4458 IX
C
ORP
S
BL
VD.
MAYOSTREET
T
T
MOOR STREET
Multi - purposeCourts
W
IL
L
IA
E N U E
MISSION
LOOP
ANTENNA TOWER
JOHNSON
WALL W/FENCE
STREET
P A
R K
IN
L
T
STREET
PAINE
S-5
S-571
T5497 T5492
T5425
60026001
60066005
551255
5518 5
K R Z
Y Z
O W S
K I H
IL
L S
OWEN AVENUE
T-109
T-108
T-1197
478 4771
#1
#2
#3
#4
73027052
T-371
S-226
S-3739
S
S
P O R T E R
233823362335 2337
23312330 23342333
765252
C
B
J2 ANNEX
GATE #19(was #20)
GATE #18(was #8B)
GATE #17(was #23)
GATE #15(was #43) GATE #2(was #5) GATE #3(was #7)
GATE #4(was #8)
GATE
#14
(wa s #
19)
GATE #13(was #17)
GATE #12(was #18)
GATE #11(was #39) GATE #10(was #38)
GATE #16(was #1)
GATE #1(was #10)
GATE #9(was #60)
GATE #8(was #37)
GATE #6(was #52) GATE #7(was 329)
GATE #5(was #12)
GATE #21(was #3)
GATE #20(was #2)
SKATEBOARD
C H
IP
P
IN
G
MINIATURE
YONGSAN, KOREA
WITH HEAT PUMP SYSTEM, B2556
PWO 155079, REPLACE FAILING H.V.A.C SYSTEM
I
N T
S
Sheet of
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
P L
O T S
C A
L E
S E
O U
L ,K
O R
E A
F
IL
E N
A M
E
IS
S
U E D
A T
E
IM
C
O M
D E
P A
R T
M E
N T O
F T
H E A
R M
Y
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U S
A G -Y
O N
G S
A N
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
E D B
Y
C K
D B
Y
P W
O /P
R O J E
C T N
O
U S
IN
G A
G E
N C
Y
G
D G
N
G-002
J
U L
Y
J
U L
Y
G2 NOT TO SCALE
N
N
PROJECT LOCATION PLAN
P R
O J E
C T L
O C
A T
IO
N P
L A
N
K I
C
H
A N
O N
G S
A N
K O
R E
A
W
IT
H H
E A
T P
U M
P S
Y S
T E
M
B
R E
P L
A C
E F
A
IL
IN
G H .V .A .C S
Y S
T E
M
F Y
Sheet of
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
P L
O T S
C A
L E
S E
O U
L ,K
O R
E A
F
IL
E N
A M
E
IS
S
U E D
A T
E
IM
C
O M
D E
P A
R T
M E
N T O
F T
H E A
R M
Y
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U S
A G -Y
O N
G S
A N
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
E D B
Y
C K
D B
Y
P W
O /P
R O J E
C T N
O
U S
IN
G A
G E
N C
Y
M-001
GENERAL NOTE SCOPE OF WORK (MECHANICAL)
NOTE :
I
N T
S
M
D G
N
SCOPE OF WORK (ELECTRICAL)
NOTE :
A. REPAIR/MAINTENANCE (K-WORK)
A. REPAIR/MAINTENANCE (K-WORK)
J
U
J
U L
Y
K I
H
A N
O N
G S
A N
K O
R E
A
W
IT
H H
E A
T P
U M
P S
Y S
T E
M
B
R E
P L
A C
E F
A
IL
IN
G H .V .A .C S
Y S
T E
M
F Y
7SCOPE OF WORK (ARCHITECTURAL)
MECHANICAL EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.
2. EXACT RATINGS AND SETTINGS OF ELECTRICAL EQUIPMENT AND DEVICES SHALL BE IN ACCORDANCE WITH
CRITERIA AND CONTRACT SPECIFICATIONS.
ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE, LIFE SAFETY CODE, UNIFIED FACILITIES
1. ALL ELECTRICAL WORK SHOULD BE DONE IN ACCORDANCE WITH THE CURRENT EDITIONS OF NATIONAL
A. REPAIR/MAINTENANCE (K-WORK)
11. SALVAGEABLE MATERIALS SHALL BE RETURNED TO DPW.
PROTECTION TO KEEP THE ROOMS CLEAN DURING CONSTRUCTION.
10. THE CONTRACTOR SHALL PROVIDE, INSTALL, AND REMOVE CONSTRUCTION BARRICADES AND/OR
U.S. GOVERNMENT.
ACTIVITIES, AND THE LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE
9. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION
TO ITEMS SUCH AS WALLS, CEILING, ROOF, PIPE, DUCT, EQUIPMENT AND ELECTRICAL ITEMS.
SYSTEM AT NO ADDITIONAL COST TO THE GOVERNMENT, INCLUDING, BUT NOT NECESSARILY LIMITED
AS NECESSARY TO ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE ALARM
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS
BE SUBMITTED FOR APPROVAL AS REQUIRED BY THE CONTRACT SPECIFICATIONS.
PROPOSED CONTROL SYSTEM WHICH MAY DEVIATE FROM THAT SHOWN ON CONTRACT DRAWINGS SHALL
SATISFY ALL FUNCTIONAL REQUIREMENTS SHOWN ON DRAWING. SHOP DRAWINGS OF THE ACTUAL
7. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE AND WORKABLE CONTROL SYSTEM TO
STANDARD TECHNICAL SPECIFICATIONS FOR MISCELLANEOUS PROJECTS, KOREA.
STRICT ACCORDANCE WITH APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL. O & MA
6. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN
WORK AT NO ADDITIONAL COST TO THE U.S. GOVERNMENT.
THIS PROJECT. THE DETAILS WILL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF
5. FOR O & MA PROJECTS, KOREA, OCTOBER 1, 2003 DEPARTMENT OF THE ARMY FORM AS A PART OF
GOVERNMENT.
4. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY
FIELD CONDITIONS AND SUBMITTED TO THE CONTRACTING OFFICER FOR APPROAL.
SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL
3. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS.
THE CONTRACTING OFFICER.
AREAS CAUSED BY THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY
2. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING
DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND
G E
N E
R A
L N
O T
E A
N D S
C O
P E O
F W
O R
K
QUANTITY (MA IDIQ) DOCUMENT.
(INCLUDING NEW CONSTRUCTION WORK UNDER $750K) MULTIPLE AWARD INDEFINITE DELIVERY INDEFINITE
LICENSE AND SHOULD MEET OTHER REQUIREMENTS AS SPECIFIED ON KOREA-WIDE GENERAL CONSTRUCTION
5. FOR THIS PROJECT, THE PROJECT MANAGER SHOULD BE A FIRST CLASS BUILDING FACILITIES ENGINEER
SHOWN ON DRAWINGS.
4. PROVIDE ELECTRIC CEILING MOUNTED HEATERS, AND ALL ASSOCIATED ACCESSORIES, FOR HVAC SYSTEM AS
INDICATORS AND LABELS SHALL BE IN ENGLISH.
PAD, AND ALL ASSOCIATED ACCESSORIES, FOR HVAC SYSTEM AS SHOWN ON DRAWINGS. REMOTE CONTROLLER
VENTILATOR, CONTROLS, CO2 SENSOR, DIFFUSERS, DAMPERS, DUCTS, INSULATIONS, PIPE LINES, CONC.
3. PROVIDE NEW DUCT-FREE SPLIT HEAT PUMP UNITS (IN-CEILING CASSETTE TYPE), ENERGY RECOVERY
IN THE CEILING SPACE AS SHOWN ON DRAWINGS.
2. ABANDON EXISTING AHU, DUCTS, PIPES (STEAM & COOLING), VALVES, AND ALL ASSOCIATED ACCESSORIES
ASSOCIATED ACCESSORIES, FOR HVAC SYSTEM AS SHOWN ON DRAWINGS.
1. REMOVE EXISTING A/C UNIT, PIPES (STEAM & COOLING), VALVES, DIFFUSERS, CONC. PAD, AND ALL
WITH USER. (BASED ON THE REGULATION ICD 705)
5. ALL PHASES OF THE CONTRACTOR TO BUY AND STOCK THE MATERIALS SHOULD BE DONE IN CONSULTATION
4. THE PIPE/DUCT WORK INSTALLATION SHALL BE IN ACCORDANCE WITH ICD/ICS 705.
SHALL PROVIDE THE TEMPORARY COOLING OR HEATING SYSTEM TO THE ENTIRE BUILDING.
3. IF THE CONTRACTOR IS GOING TO CONSTRUCTION DURING THE COOLING/HEATING SEASON, THE CONTRACTOR
A LICENSED OR CERTIFIED INSTALLER.
2. INSTALLATION OF THE HVAC SYSTEM SHALL BE IN COMPLIANCE WITH MANUFACTURER'S SPECIFICATION BY
CLEARANCE, EQUIPMENT PAD SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.
1. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE
(2P-20A-10000AIC-240VAC).
2. PROVIDE NEW CIRCUIT BREAKER (2EA) FOR NEW HEAT PUMP INDOOR UNITS, ERV AND ELECTRIC HEATER.
(CONNECT TO THE EXISTING PANEL "A")
1. PROVIDE POWER SUPPLY WITH ASSOCIATED WIRING FOR NEW HEAT PUMP UNITS, ERV AND ELECTRIC HEATER.
2. PAINT AND PATCH TO MATCH EXISTING WALL SURFACES DISTURBED BY MECHANICAL AND ELECTRICAL WORK.
(APPROX. 900 SQ FT.)
1. REPLACE DAMAGED GYPSUM BOARD CEILING WITH NEW DISTURBED BY MECHANICAL AND ELECTRICAL WORK.
songmin.m.kim Text Box
(APPROX. 1,200 SQ FT.)
M2 SCALE = 1:50
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
N
P.O.C
Sheet of
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
P L
O T S
C A
L E
S E
O U
L ,K
O R
E A
F
IL
E N
A M
E
IS
S
U E D
A T
E
IM
C
O M
D E
P A
R T
M E
N T O
F T
H E A
R M
Y
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U S
A G -Y
O N
G S
A N
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
E D B
Y
C K
D B
Y
P W
O /P
R O J E
C T N
O
U S
IN
G A
G E
N C
Y
MD101
I
N T
S
M D
D G
N
J
U
J
U L
Y
K I
H
A N
O N
G S
A N
K O
R E
A
W
IT
H H
E A
T P
U M
P S
Y S
T E
M
B
R E
P L
A C
E F
A
IL
IN
G H .V .A .C S
Y S
T E
M
F Y
EXIST/REMOVAL H.V.A.C ENLARGED PLAN
QTYITEM D E S C R I P T I O N
DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)HP
DUCT-FREE SPLIT HEAT PUMP SYSTEM (OUTDOOR UNIT)1
HPO
HP
DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)
HP
MFR. LG MODEL NO. ARNU183TNA4 OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
MFR. LG MODEL NO. ARNU243TNA4 OR APPROVED EQUAL.
SAME AS ABOVE ITEM NO. EXCEPT
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
MFR. LG MODEL NO. ARUN144BTE4 OR APPROVED EQUAL.
: 208 V, 3 PH, 60 Hz
: 47,500 W (162,000 BTU/HR)
: 42,200 W (144,000 BTU/HR)
ELECTRIC CEILING HEATER (FOR LATRINE)
MFR. QMARK MODEL NO. CDF548RE OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
EH
EQUIPMENT SCHEDULES
: 208 V, 1 PH, 60 Hz
: 6,300 W (21,500 BTU/HR)
: 5,600 W (19,100 BTU/HR)
: 208 V, 1 PH, 60 Hz
: 8,000 W (27,300 BTU/HR)
: 7,100 W (24,200 BTU/HR)
ALL NECESSARY SAFETIES & OPERATING ACCESSORIES. ETL LISTED.
REFRIGERANT CHARGE, VIBRATION ISOLATORS, CONTROL SYSTEM, AND
COIL, FAN(S) & MOTOR(S), REFRIGERATION COMPONENTS, R-410A
SYSTEM, CONSISTING OF DC INVERTER COMPRESSOR(S), AIR-COOLED
OF AIR-TO-AIR COOLING AND HEATING SYSTEM. HEATING MULTI
WEATHER-PROOF, UNIT SHALL FUNCTION AS THE OUTDOOR COMPONENT
NECESSARY SAFETIES & OPERATING ACCESSORIES.
LOUVERS. COMPLETE WITH CONTROLS, WALL THERMOSTAT, ALL
AND FEATURE AUTOMATIC THERMAL CUTOUT AND RESET. ADJUSTABLE
STEEL SHEATHED, TUBULAR HEATING ELEMENTS. BUILT-IN FAN DELAY,
PAINTING PROCESS. COPPER FINS BRAZED TO LOW-WATT DENSITY,
STEEL ENCLOSURE FINISHED W/ BAKED ENAMEL ELECTROSTATIC
LUBRICATED MOTOR FOR WHISPER QUIET OPERATION. HEAVY GAGE
ALUMINUM FAN AND RUGGED IMPEDANCE-PROTECTED, PERMANENTLY
UL LISTED, CEILING RECESSED MOUNTED, DOWNFLOW, FIVE BLADE
: 9.6 Amp, 208 V, 1 PH, 60 Hz
: 2,000 W (6,800 BTU/HR)
ASSOCIATED ACCESSORIES
PIPE LINES, CONC. PAD, AND ALL
AIR-COOLED CONDENSING UNIT,
REMOVE EXISTING
P.O.C
EXISTING PIPES
ABANDON
IN THE CEILING SPACE
ASSOCIATED ACCESSORIES
PIPES, DUCTS, VALVES, AND
ABANDON EXISTING AHU,
(TYPICAL)
EXISTING GRILLE
REMOVE
(TYPICAL)
EXISTING DIFFUSER
REMOVE
ACCESS DOOR (TYPICAL)
REMOVE EXISTING
AD AD
AD
TO REMAIN (TYPICAL)
EXISTING LIGHTING FIXTURE
1 ENERGY RECOVERY VENTILATORERV
ELECTRIC POWER INPUT
LOW
MEDIUM
HIGH
FAN CAPACITY
AND ALL NECESSARY ACCESSORIES. UL-LISTED.
CONTROLLER, WIRELESS REMOTE CONTROLLER, HANGING BRACKETS,
TEMPERATURE DURING SEASON CHANGES, WALL MOUNTED WIRE
COOLING-OR HEATING-MODE TO MAINTAIN THE OPTIMUM ROOM
DISCHARGE, CLEANABLE FILTERS, AUTOMATICALLY SWITCHES TO
CONDENSATE PUMP SYSTEM, ADJUSTABLE AIR LOUVERS FOR 4-WAY
COIL, TURBO FAN, TOTAL VIRUS FILTER, BLDC INVERTER MOTOR,
WITH HEAT PUMP OUTDOOR UNIT. COMPLETE WITH COOLING / HEATING
IN-THE-CEILING MOUNTED, DIRECT-EXPANSION FAN COIL TO MATCHED
: 208-230 V, 1 PH, 60 Hz
: 388 CFM @ 0.24 WG.ESP.
: 471 CFM @ 0.44 WG.ESP.
: 471 CFM @ 0.80 WG.ESP.
NECESSARY SAFETIES AND OPERATING ACCESSORIES.
SENSOR, HANGING VIBRATION ISOLATORS, COMPLETE WITH ALL
MOUNTED WIRE CONTROLLER, FILTERS, WALL MOUNTED WIRE CO2
DAMPER ON EXHAUST AIR STREAM. BYPASS MODE W/ DAMPER, WALL
WITH MOTORIZED DAMPER ON OUTDOOR AIR STREAM AND MOTORIZED
FAN, CONTROLS, AUTOMATIC DEFROST CYCLE FEATURES, EQUIPPED
OUTDOOR AIR STREAM, 3-SPEED SUPPLY FAN AND 3-SPEED EXHAUST
FLEXIBILITY, NO MIXING OF STALE AIR STREAM WITH THE FRESH
FACTORY ASSEMBLED, ACOUSTICAL DESIGN, INSTALLATION
PES-C0RV0 (CO2 SENSOR) OR APPROVED EQUAL.
MFR. LG MODEL NO. ARVU053ZEA2, PQRCVSL0 (CONTROLLER),
E
Q U
IP
M E
N T S
C H
E D
U L E
S
E X
IS
T /R
E M
O V
A L H .V .A .C E
N L
A R
G E
D P
L A
N
OFFICE
TRAINING RM
TOILET
STORAGE
OFFICE
STORAGE
TRAINING RM
HP
HP
HP
HP
M3 SCALE = 1:50
N
Sheet of
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
P L
O T S
C A
L E
S E
O U
L ,K
O R
E A
F
IL
E N
A M
E
IS
S
U E D
A T
E
IM
C
O M
D E
P A
R T
M E
N T O
F T
H E A
R M
Y
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U S
A G -Y
O N
G S
A N
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
E D B
Y
C K
D B
Y
P W
O /P
R O J E
C T N
O
U S
IN
G A
G E
N C
Y
MH101
I
N T
S
M H
D G
N
J
U
J
U L
Y
K I
H
A N
O N
G S
A N
K O
R E
A
W
IT
H H
E A
T P
U M
P S
Y S
T E
M
B
R E
P L
A C
E F
A
IL
IN
G H .V .A .C S
Y S
T E
M
F Y
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
EXIST/NEW H.V.A.C ENLARGED PLAN
E X
IS
T /N
E W H .V .A .C E
N L
A R
G E
D P
L A
N
SHEET M-501
FOR DETAIL SEE 3 OF
NEW CONC. PAD
METAL PIPE TRAY
PIPE SIZE
VAPOR LIQUID DRAINITEM NO.
25.4 mm
25.4 mm
HP
HP
HPO
12.7 mm
ACCESS DOOR (TYP.)
NEW
(TYP OF 10)
SEE 4 OF SHEET M-501
Y-JOINT FOR DETAIL
PIPE CHASE
9.52 mm
9.52 mm15.875 mm
15.875 mm
28.575 mm
T T
T T
T T
O
A
MDMD
E
A
VDVD
VDVD
VD
ERV
VENTILATOR UNIT
ENERGY RECOVERY
EH
(CEILING MOUNTED TYPE)
ELECTRIC HEATER
C C
CONTROLLER
CO2 SENSOR
VD
200 200 150
200 200 150
BIRD SCREEN (TYP OF 2)
WALL CAP W/ STS METAL
SQUARE SHAPE HOODED
STAINLESS STEEL
UL 181 AIR DUCT APPROVED (TYPICAL)
POLYETHYLENE VAPOR BARRIER EXTERIOR COVER
NE 1000 CORE+POLY INSULATION+INCOMBUSTIBLE
PE POLY ACOUSTICAL FLEXIBLE DUCT
(TYP OF 3)
SUPPLY DIFFUSER
ROUND PAN
(TYP OF 3)
RETURN DIFFUSER
ROUND PAN
HPO
(OUTDOOR UNIT)
DUCT-FREE HEAT PUMP
HP
HP
(TYP OF 3)
CEILING MOUNTED, 4-WAY
DUCT-FREE HEAT PUMP
(TYP OF 3)
CEILING MOUNTED, 4-WAY
DUCT-FREE HEAT PUMP
40 LPS
150 NCD
40 LPS
150 NCD
89 LPS
200 NCD
89 LPS
200 NCD
89 LPS
200 NCD
89 LPS
200 NCD
AT EXPOSED EDGES
20mm CHAMFERS
GRAVEL BASE
150mm THK.
Sheet of
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
P L
O T S
C A
L E
S E
O U
L ,K
O R
E A
F
IL
E N
A M
E
IS
S
U E D
A T
E
IM
C
O M
D E
P A
R T
M E
N T O
F T
H E A
R M
Y
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U S
A G -Y
O N
G S
A N
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
E D B
Y
C K
D B
Y
P W
O /P
R O J E
C T N
O
U S
IN
G A
G E
N C
Y
M-501
I
N T
S
M
D G
N
J
U
J
U L
Y
K I
H
A N
O N
G S
A N
K O
R E
A
W
IT
H H
E A
T P
U M
P S
Y S
T E
M
B
R E
P L
A C
E F
A
IL
IN
G H .V .A .C S
Y S
T E
M
F Y
1 INDOOR HEAT PUMP UNIT INSTALLATION DETAIL
SECTION
REMOTE CONTROL
FULL BOX
ELECTRICAL CONC. BOX
CEILING
ROOM
(CEILING CASETTE 4-WAY TYPE)
INDOOR HEAT PUMP
ENLARGED SECTION
ROOM
R.L/R.G
DRAIN PIPE
CEILING
PUMP
HEAT
(TYP)
HANGERMIN 300
FOR SERVICE
ACCESS DOOR
600x600 CEILING
CABLE
POWER
CEILING
R.L/R.G
DRAIN PIPE
DRRAIN HOSE
(CEILING CASETTE 4-WAY TYPE)
INDOOR HEAT PUMP
MAX.700
(TYP.)
HANGER
SLOPE
1/50-1/100
SEE
TYPICAL REFRIGERANT PIPING DIAGRAM
FILTER DRIER
LIQUID LINE
CONDENSATE DRAIN
DRAIN PUMP
CONDENSATE
THERMOSTAT
SWITCH
DISCONNECT
FUSED
VAPOR LINE
Y JOINT DETAIL
LIQUID PIPE 6.35A/ 9.52A
TAPE
Y-JOINT
INLET
INSULATION REFRIGERANT LIQUID/ GAS PIPE
COVER
OUTLET
SECTION
GAS PIPE 12.7/ 15.88
PIPE INSULATION:19T
EPDM
PIPE INSULATION:19T
EPDM
VCTF-SB1.25x2C
CABLE LINE
CONCRETE PAD DETAIL3
(OUTDOOR UNIT)
DUCT-FREE HEAT PUMP
(INDOOR UNIT)
DUCT-FREE HEAT PUMP
M E
C H
A N
IC
A L D
E T
A
IL
S
SWITCH
FUSED DISCONNECT
WEATHERPROOF
EQUIPMENT INSTALLATION5
ISOLATORS
SPRING
HANGER ROD
HANGER PLATE
VENTILATOR
ENERGY RECOVERY
FIN. GRADE
150 150
SECTIONPLAN
N F S M
150150ACTUAL EQUIPMENT SIZE
#4 @300 O.C.
50 CLR
CONC. PAD
150 150 150150ACTUAL EQUIPMENT SIZE
A C
T U
Q
U I
P M
E
Z E
EQUIPMENT UNIT
WITH MANUFACTURER.
FINAL PAD SIZE SHALL BE CORDINATED
6" (150mm) LARGER THAN UNIT SIZE AND
ALL EQUIPMENT CONC PAD SIZE SHALL BE
NOTE :
OFFICE
STORAGE
TRAINING RM
HP
HP
HP
HP
JJ
JJ J
E1 SCALE = 1:50
N
Sheet of
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
NUMBER
IDENTIFICATION
SHEET
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
D A
T E
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
P L
O T S
C A
L E
S E
O U
L ,K
O R
E A
F
IL
E N
A M
E
IS
S
U E D
A T
E
IM
C
O M
D E
P A
R T
M E
N T O
F T
H E A
R M
Y
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
U S
A G -Y
O N
G S
A N
D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
YU
AS -G
F
O
O
D I
IC
C E
ET
T R
R
R K
S W
LA
PUBO
OF PUBLIC WORKS
DIRECTORATE
IMCOM
A P
P R
O V
E D B
Y
C K
D B
Y
P W
O /P
R O J E
C T N
O
U S
IN
G A
G E
N C
Y
EP101
I
N T
S
E P
D G
N
J
U
J
U L
Y
K I
H
A N
O N
G S
A N
K O
R E
A
W
IT
H H
E A
T P
U M
P S
Y S
T E
M
B
R E
P L
A C
E F
A
IL
IN
G H .V .A .C S
Y S
T E
M
F Y
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
E X
IS
T /N
E W E
L E
C T
R
IC
A L P
O W
E R P
L A
N
EXIST/NEW ELECTRICAL POWER PLAN
** ADDITIONAL LEGEND (THIS SHEET ONLY)
SPLIT HEAT PUMP SYSTEM INDOOR UNIT.
4" OCTAGON OUTLET BOX,FOR DUCT-FREE
SINGLE RECEPTACLE(2P-3W-20A-250V),J :
2PST-3W-240V-60A, NEMA 3R ENCL
: EXST SAFETY SWITCH NON FUSIBLE TYPE
2-#12 & 1-#12(G) IN 16C
TO EXST PANEL "A" SPACE
2-#4 & 1-#12(G) IN 27C
2PST-3W-240V-60A, NEMA 3R ENCL
EXST SAFETY SWITCH NON FUSIBLE TYPE
2-#12 & 1-#12(G) IN 16C
TO EXST PANEL "A" SPACE
(FOR INDOOR HEAT PUMP UNITS & ERV)
2P-20A-10000AIC-240VAC
PROVIDE TWO(2EA) CIRCUIT BREAKER
EXST PANEL "A"
U
T
T T
T T
ERV
VENTILATOR UNIT
ENERGY RECOVERY
EH
(CEILING MOUNTED TYPE)
ELECTRIC HEATER
C C
J
J
J
HPO
(OUTDOOR UNIT)
DUCT-FREE HEAT PUMP
HP
HP
(TYP OF 3)
CEILING MOUNTED, 4-WAY
DUCT-FREE HEAT PUMP
(TYP OF 3)
CEILING MOUNTED, 4-WAY
DUCT-FREE HEAT PUMP
| 2017-07-18T10:24:48+0900 | |
| KIM.SONG MIN.1395327050 |
| 2017-07-18T14:36:21+0900 | |
| YI.TONG.CHOL.1288574037 |
| 2017-07-18T10:26:19+0900 | |
| KIM.SONG MIN.1395327050 |
| 2017-07-19T12:54:03+0900 | |
| CHANG.PYONG SANG.1401610487 |
| 2017-07-25T10:28:13+0900 | |
| SON.TAK KUN.1402670793 |
| 2017-07-19T13:14:42+0900 | |
| YANG.PONG KI.1363924480 |
| 2017-07-19T12:54:38+0900 | |
| CHANG.PYONG SANG.1401610487 |
| 2017-07-18T14:33:42+0900 | |
| YI.TONG.CHOL.1288574037 |
| 2017-07-18T10:29:45+0900 | |
| KIM.SONG MIN.1395327050 |
| 2017-07-18T10:30:37+0900 | |
| KIM.SONG MIN.1395327050 |
| 2017-07-18T14:34:23+0900 | |
| YI.TONG.CHOL.1288574037 |
| 2017-07-25T10:29:26+0900 | |
| SON.TAK KUN.1402670793 |
| 2017-07-18T14:44:53+0900 | |
| U.YONG MYONG.1288986793 |
| 2017-07-18T14:15:18+0900 | |
| KIM.SONG MIN.1395327050 |
| 2017-07-18T14:17:25+0900 | |
| KIM.SONG MIN.1395327050 |
| 2017-07-18T14:37:37+0900 | |
| YI.TONG.CHOL.1288574037 |
| 2017-07-18T14:20:42+0900 | |
| KIM.SONG MIN.1395327050 |
| 2017-07-18T14:35:06+0900 | |
| YI.TONG.CHOL.1288574037 |
File details come from the government source that posted it. Updated .