DWG_AE101.pdf

PDF 2 MB Posted

Attached to
Repair Roll-Up Doors
Solicitation number
W91QVN-17-R-0164
Issued by

About this file

Drawing

View the file

Other files

File Type Posted
SBMTL-RGTR-DFT.xlsx XLSX spreadsheet
W91QVN-17-R-0164.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

NUMBER

IDENTIFICATION

SHEET

D A

T E

M A

R K

D E

S C

R I P

T I O

N A

P P

R

D A

T E

D E

S I G

N

B Y

D A

T E

S I Z

E

P L

O T

S C

A L

E

F I L

N A

M E

I S

S U

T E

I M

C O

M

D E

P A

R T

M E

F

H

R

M Y

E N

G I N

E E

R I

G

I V I S I O

N

U S

A G

Y O

N G

S A

N

D I R

E C

T O

R A

P

B L

W

R K

S

I

YU

AS -G

F

O

O

D I

IC

C E

ET

T R

R

R K

S W

LA

PUBO

OF PUBLIC WORKS

DIRECTORATE

IMCOM

A P

P R

O V

C K

P W

O

P R

O J

E

U S I

E N

C Y

Sheet of

AE101

SCOPE OF WORK

M

A E

A. REPAIR/ MAINTENANCE WORK

01 01

K I

M

Y

K

H A

N

C

H

M

Y

SCALE : 1 / 200AE101

COMMENCING ANY CONSTRUCTION OR RENOVATION.

ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO

1. THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING

AS DIRECTED BY THE CONTRACTING OFFICER.

THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS

OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED BY

2. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT

AND SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS

SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE

MAY NOT MATCH FIELD CONDITIONS EXACTLY,

3. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS

INSTALLATION.

APPROVED BY THE C.O.R. BEFORE FABRICATION AND

ALL DOOR AND WINDOW DETAILS AND DRAWING SHALL BE

THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR

SPECIFICATIONS AND MANUFACTURES INSTRUCTIONS.

5. ALL DOORS AND WINDOWS SHALL BE FABRICATED I.A.W.

GENERAL NOTES

SHOP DRAWINGS FOR APPROVAL BY GOVERNMENT.

4. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION

TO THE PROJECT CONTRACT.

ARCHITECTURAL SCOPE OF WORK AT NO ADDITIONAL COST

NOVEMBER 2015) WILL BE UTILIZED TO ACCOMPLISH THE

O & MA STANDARD DETAILED DRAWINGS, 2014 (DATED 30

6. THE ARCHITECTURAL STANDARD DRAWINGS SHOWN IN THE

WALL - - - - U=0.092 (R=10.86)

ROOF - - - - U=0.052 (R=19.23)

7. MAXIMUM U-FACTORS AND R-VALUE HEAT TRANSMISSION

NOTE FOR ROLL-UP DOOR

D2D1 D1 D1

D1 D1 D1 D1

EXST. FLOOR PLAN (S-523)

7,700W x 5,700H

OPENING SIZE

ROLL-UP DOOR

INDEFINITE DELIVERY INDEFINITE QUANTITY (MA IDIQ) DOCUMENT.

(INCLUDING NEW CONSTRUCTION WORK UNDER $ 750K) MULTIPLE AWARD

REQUIREMENTS AS SPECIFIED ON KOREA-WIDE GENERAL CONSTRUCTION

CLASS ACHITECTURAL ENGINEER LICENSE AND SHOULD MEET OTHER

3. FOR THIS PROJECT, THE PROJECT MANAGER SHOULD BE A FIRST

WITH ROLL-UP DOOR OPERATION AS SHOWN ON DWG. (D1:7EA.)

INCLUDING FRAMES AND ALL ELECTRICAL DEVICES CONCERNED

1. REPLACE EXISTING DETERIORATED ROLL-UP DOORS WITH NEW

K

K O

R E

A

B L

D G

N O

S

R E

P A

O R

S

F Y

A

N E

R

T E

S

F L

O

A N

S C

O

W

R K

N O

T

BAY 1BAY 2BAY 3BAY 4

BAY 5BAY 6BAY 7BAY 8

INCLUDING REPLACEMENT OF PNEUMATIC SAFETY EDGE DEVICE.

2. CHECK AND REPAIR DOOR "D2" (BAY 5) FOR SMOOTH OPERATION

3,0103,010

43,98043,980 25,203

69,18369,183

* OR APPROVED EQUAL

- COLOR/ FINISH : SELECTION BY USING AGENCY

PHOTO LASER SENSOR (MANUFACTURE : LIFT MASTER)

- SAFETY EDGE DEVICE : AIR WAVE EDGE DEVICE AND

- GUIDES : MINIMUM 4.8mm THK.

- WIND LOAD : 20 LBS OR 45M/S

- THICKNESS : 18-GAUGE

(WIND LOCK : ONE INSTALL PER TEN SLAT)

- SLAT TYPE : INSULATED SLAT TYPE

(ANTI-CORROSION LONG LASTING COATING PROCESS)

FINISH : EGYPTIAN COATING

- OIL TEMPER TORTION SPRINGS (RICHARD WILCOX, CANADA) :

- COUNTER BALANCE SYSTEM

VOLTAGE : 208, PHASE : THREE

- OPERATOR : 2HP (CERTIFICATED BY UL)

- OPERATION : MANUAL AND AUTOMATIC

www.shinbondoor.com

- LOCAL COMPANY : SHINBON CORPORATION

- MANUFACTURE : RAYNOR. (www.raynor.com)

FRONT VIEW REAR VIEW

INSIDE VIEW PHOTO LASER SENSOR

2017-06-01T14:01:24+0900
KIM.YONG KYU.1288268459
2017-06-01T14:20:14+0900
HAN.CHIN HO.1276924890
2017-06-08T11:11:16+0900
CHANG.PYONG SANG.1401610487
2017-06-05T08:52:48+0900
CHO.SONG.SAM.1288700750

File details come from the government source that posted it. Updated .