SCHEDULE OF DRAWINGS

RING NO. REF. NO.REVISION STATUSDWG. NO. SHT. NO.REF. NO.

1 OF 1T - 1

RING NO. DESCRIPTION OF DRAWINGS

TITLE SHEET

DWG. NO. SHT. NO. DESCRIPTION OF DRAWINGS REVISION STATUS

TITLE SHEET

T-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

E - 1

E - 2

E - 3

ELECTRICAL

E - 4

E - 5

E - 6

E - 7

E - 8

E - 9

PROJECT SITE PLAN

FEWR NO 164139, CAMP CASEY

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

EXAMPLE OF TRANSFORMER DETAILS & HIGH VOLTAGE UNDERGROUND CABLE

RISER DETAILS, GENERAL NOTES & SCOPE OF WORK

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-1

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-2

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-3

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-4

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-5

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-6

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-7

65-A

12 CM

ST

STREAM

S T

S T

P V C

227.5

J-4

ST

CM

.5

.9

W A

L L

W A

L L

W A

L L

WALL

W A

L L

WALL

228.4

ST

GAL27

LAUNDRY

KSC

PEST

647667

WH-1

WH-2

DPW HQ

A

B

651A

833T

808 811

715 726

A B

A

B

1149 1151

A

B

A

BA

B

A

B

2372A

2373T

A

C

A

B

A

B

2609T

2514 2540

8008T

2540T

1991 1963

A B

456A

463Z

549 546

8114T

560G

A

B

86M

48T

A

B

39 55

134 133

202A

258252

1785 235

FOOT BR

VEH BR

FOOT BR

VEH BR

VEH BR

VEH BR

VEH BR

VEH BR 1821

VEH BR

VEH BR

VEH BR

VEH BR

FOOT BR

VEH BR

VEH BR

FOOT BR

FOOT BR

VEH BR

VEH BR

VEH BR

FOOT BR

FOOT BR

VEH BR

VEH BR

VEH BR

VEH BR

FOOT BR

1158A

1158B

.8

.5

S T

R C

6 PVC

ST

T

C M

S T

268.6

STREAM

DISCHARGE TO

65-A

12 CM

ST

STREAM

447A

F

F

497A

497B

458Z

A

B

A B

VEH BR

VEH BR

472?

455?

BARRIER

635A

2002B

A B

48A

A

B

A B

A

B

A

B

A

B

A

B

GRAVES

GRAVES

B A

S K

E T

B A

L L

C O

U R

T

706(707A)

(2298)

1071?

A B

1760?

VEH BR?

VEH BR?

BARRIER

FLAG

FO

O

TBALL

FIELD

(SYN

TH

ETIC

TU

R F

AR

EA)

1919LIFT STATION

VEH BR

BARRIER

O.S.

O.S.

PARKING

TT

B

UTILITY

BLDG

N

L O C A T I O N M A P

NOT TO SCALE

45 1

DONGDUCHON

CAMP CASEY

GATE 2

GATE 1

DPW

#2299

FIRE STATION

N

E A S T S E ACHUNCHON

PYONGTAEK

KUNSAN

KWANGJU

INCHON

S E A

W E S T

MUNSAN

DAEGU

CHINHAE

WAEGWAN

BUSAN

DAEJEON

OSAN

UIJONGBU

SEOUL

TONGYOUNG

MOKPO

SEWAGE PLANT

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMYCONTRACTING OFFICER DURING THE SITE ORIENTATION.

SHALL BE DETERMINED, DESIGNATED AND COORDINATED WITH THE

THE CONTRACTOR'S HAUL ROUTE, STORAGE AND OPERATIONS AREA

NOTE:

PROJECT LOCATION PLAN

SCALE: 1 : 6,000

1:6000

SCALE:

0 60 120 240

PROJECT LOCATION PLAN

ELECTRICAL

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

E-1

: LOCATION OF H-FRAME MOUNTED TRANSFORMER

NOT TO SCALE

300 BEYOND PAD

ON ALL AROUND

A MINIMUM OF

EXTEND GRAVEL FILL

G

AS REQ'D

G

COOLING

150 MIN.

CORRUGATION

150 MIN.

G

G

AS REQ'D GROUND ROD,

19dia x3000mm LG

COPPER CLAD STEEL

W/WELDING CONNECTION

(TYPICAL)

COMPARTMENTAL TYPE

TRANSFORMER

PAD MOUNTED

BASE COURSE

150 MIN.

CASE GROUND

150 MIN.

EXTEND GRAVEL FILL

A MINIMUM OF

ON ALL AROUND

300 BEYOND PAD

PRIMARY CONDUIT AS REQ'D

GROUND WIRE, AS REQ'D

SECONDARY CONDUIT AS REQ'D

(TYPICAL)

"A" "A"

P L A N

"A-A" SECTION

NFSM

W/END CAP FOR FUTURE)

(1EA:STUB-OUT 1500mm LG

PRIMARY CONDUIT(103 diax2 EA)

OIL LEVEL GUAGE

TYPE BUSHING

NAME PLATE

TAP CHANGER

HIGH-VOLTAGE SECTION

LIMITING FUSES HOLDERS

BAY-O-NET CURRENT

GL

SECONDARY SPADE

LOW-VOLTAGE SECTION

25.4 DRAIN PLUG

PRESSURE RELIEF DEVICE

G

AS REQ'D

G

CONCRETE PAD REINFORCED

(6"x6"-w2.9xw2.9 WIRE MESH)

G

(TYPICAL)

GROUND ROD

19 diax3000mm LG WITH

WELDING CONNECTION

COPPER CLAD STEEL

WITH 150x150x-4.0 dia.x4.0 dia.WWF

SECONDARY STELL CONDUITS

NFSM

SEAL AROUND BASE

W/SEALANT

LOAD BREAK SWITCH

SEE NOTE 1 BELOW

SAFEBREAK BUSHING

GROUND TERMINAL

NEUTRAL AND

PARKING BRACKET

(TYPICAL)

GROUND WIRE, #3/0 "BC"

50 CHAMBER, ALL AROUND

ALL SAFE BREAK BUSHINGS

BEFORE REPLACING FUSES

LABEL ; WARNING-DISCONNECT

FILTERING VALVE

NETURAL TERMINAL

ELBOW TYPE SURGE ARRESTER

CONDUIT COUPLING

SECONDARY PVC CONDUITS

AS REQ'D

EXAMPLE OF TRANSFORMER INSTALL DETAIL

G

"BROWN" (TYPICAL)

PIN TYPE INSULATOR

ANGLE CROSSARM BRACE (TYP)

"P2-8"

STEEL CROSSARM,

CONCRETE POLE, 14M-500Kg

G

GROUND WIRE, #4 "BC" (TYP)

12KV (TYP OF 3EA)

LIGHTNING ARRESTER

#2 "BC" (TYP)

G

G

G

G

1/C, #1, 600V, "XLP"

STEEL BAND (TYPICAL)

1/C, #1, 15KV, "XLP" (TYP.)

STEEL CROSSARM, "P1-8"

CABLE TERMINATION

600V, #1(MAX)x1EA

G.L

CONDUIT

5G

G

CONDUIT COUPLING

CONDUIT (2400mm LG)

#6 "BC" IN 21dia PVC

#6 "BC" IN 21dia STL

G

SEALING BUSHING,

"CSBG 400P(4HOLES)"

AND ADAPTER KIT FOR SINGLE

CONDUCTOR, #1 MAX (TYP OF 3EA)

TERMINATION, 15KV WITH BRACKET

GALV RIGID STEEL

CONDUIT 103dia

19dia x 3000mmLG

W/WELDING CONNECTION

COPPER CLAD STEEL

GROUND ROD,

(MIN)

NOT TO SCALE

POLE KEY

G

"WHITE"

PIN TYPE INSULATOR

FUSE CUTOUT SWITCH, 15KV,

100A WITH 25A FUSES (TYP OF 3)

G

EXIST O/H PRIM LINE

3PH, 4W, 11.4KV,

PIN TYPE INSULATOR

"BROWN" (TYPICAL)

AND PLASTIC COVER (TYPICAL)

HOT LINE W/BAIL CLAMP

60HZ SYSTEM

SYMBOL BY

DESIGNED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

ENVIRONMENT

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENERGY MANAGER

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

DES

164139

REMOVAL OF EXISTING ELECTRICAL EQUIPMENT SHALL INCLUDE EQUIPMENT

INCLUDING CONDUCTORS, CABLES, EXPOSED CONDUIT, SURFACE METAL RACEWAYS,

BOXS, AND FITTINGS, BACK TO EQUIPMENT'S POWER SOURCE.

CONTACTOR SHALL VERIFY ELECTRICAL REQUIREMENT OF EQUIPMENT PRIOR TO

ALL ELECTRICAL MATERIAL AND WORKMANSHIP SHALL COMPLY WITH ALL THE

REQUIREMENTS OF NATIONAL ELECTRICAL CODE LATEST EDITION AND NATIONAL

ELECTRICAL SAFETY CODE LATEST EDITION.

THE GOVERNMENT RESERVE THE RIGHT TO POSTPONE THE REQUESTED POWER

MINIMUM OF 14 DAYS PRIOR TO THE ANY SCHEDULED POWER OUTAGE.

THE CONTRACTOR SHALL NOTIFY CONTRACTING OFFICE, AND DPW IN WRITING A

OUTAGE UP TO 8 HOURS PRIOR TO REQUESTED POWER OUTAGE.

GRADING LINE OF NEW DUCTS WILL BE LIMITED TO THE WIDTH OF DUCT EXCAVATION.

OPERATION DURING AND AFTER INSTALLATION OF ELECTRICAL SYSTEM. THE

INCLUDING SODDING, UTILITIES, STRUCTURES TO THEIR ORIGINAL CONDITION AND

THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED AREA

GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

SCOPE OF WORK

1.

E-2

TAK, YS

ELECTRICAL

TO INSTALLING THE ASSOCIATED CONDUIT & WIRING.

(REPAIR/MAINTENANCE WORKS)

REPLACE EXISTING H-FRAME POLE MOUNTED TRANSFORMERS WITH

CONTACTOR SHALL BE RESPOSIBLE TO RELOCATE EXIST EXTERIOR LIGHTING FIXTURES,

ACCESSORIES TO MEET SITE ADAPT CONDITION.

CATV BEFORE CONSTRUCTION.

CONTRACTOR SHALL COORDINATE WITH AREA MP, NEC, SIGNAL BRIGADE,

PRIMARY, SECONDARY LINE, SIGNAL CABLE AND CONTROL PANELS WITH NECESSARY

2.

LINES, CONCETE ELECTRIC POLE WITH NECESSARY ACCESSORIES.

HIGH VOLTAGE CABLE RESER SETS, PRIMARY & SECONDARY

NEW PAD MOUNTED TRANSFORMER INCLUDING UNDERGROUND

RELOCATE LIGHTING FIXTURES, SIGNAL LINES WITH NEW NESSARY ACCESSORIES.

CABLE RISER DETAIL

EXAMPLE OF HIGH VOLTAGE UNDERGROUND

8.

SHOP DRAWING FOR EXTERIOR POWER DISTRIBUTION PLAN AND CABLE RISER SET.

BIDING PURPOSE ONLY. CONTRACTOR SHALL VERIFY EXSTING SITE CONDITION AND SUBMIT

SIZE AND COUNT OF POWER DISTRIBUTION LINES ON THE DRAWINGS IS ESTIMATED FOR

CAMP CASEY

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

DETAILS, GENERAL NOTES & SCOPE OF WORK

VOLTAGE UNDERGROUND CABLE RISER

EXAMPLE OF TRANSFORMER DETAILS & HIGH

ELECRICAL

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE: 1/300

EXIST O/H PRIM. LINE

3PH, 4W, 11.4KV, 60HZ SYSTEM

(TYPICAL)

EXIST POLE (TYPICAL)

PROVIDE NEW PAD MOUNTED

DEAD-FRONT TYPE, LOAD BREAK SW,

W/BUILT-IN PROTECTIVE DEVICES (25A FUSE)

METAL ENCL, OIL-FILLED, SELF-COOLED,

RADIAL TYPE TRANSFORMER

BE DETERMINED BY COORDINATING WITH DPW.

/ACTUAL LOCATION OF PAD MOUNTED TRANSFORMER SHALL

ACCESSORIES

REMOVE EXIST ELEC POLE

PRIMARY POLE

CUTOUT SWITCHES, LIGHTNING ARRESTERS ON EXIST

PRIMARY LINE CABLE RISER SET, TERMINATION KITS, FUSE

INTERCEPT EXIST O/H PRIM LINE W/ NEW UNDERGROUND

B

A

(TYPICAL)

NEW U/G PRIM. LINE

3PH, 11.4KV-120/208V(DELTA-WYE), 60HZ, 300KVA

S

S P

S

S

S

NEW U/G SEC. LINE

4-AWG#4/0 IN 103C

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-1

O/H

O/H

U /G

O /H

O /H

O /H

O /H

(TYPICAL)

REMOVE EXIST O/H PRIM. & SEC. LINE

NEW O/H SEC. LINE 4-AWG#8

REPLACE W/NEW O/H SEC. LINE

3-1/C, #1, 15KV, "XLP" AND 1/C, #1, 600V, "XLP"

DISTRIBUTION PLAN-1

EXIST/NEW EXTERIOR POWER LINE

AND ASSOCIATED DEVICES

MOUNTED TRANSFORMERS

REMOVE EXIST H-FRAME POLE

TO EXIST ELEC POLE W/ NECESSARY

SECONDARY LINE, COMMUNICATION LINE, EXTERIOR LIGHT

AND RE-ARRANGE/RE-CONNECT EXIST PRIMARY LINE,

P1

P1

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

E-3

ACCESSORIES.

EXIST SECONDARY LINE WITH NEW ASSOCIATED

RECONNECT NEW SECONDARY LINE TO

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE: 1/300

PROVIDE NEW PAD MOUNTED

DEAD-FRONT TYPE, LOAD BREAK SW,

W/BUILT-IN PROTECTIVE DEVICES (10A FUSE)

3PH, 11.4KV-120/208V(DELTA-WYE), 60HZ, 75KVA

REMOVE EXIST ELEC POLES

PRIMARY POLE/

CUTOUT SWITCHES, LIGHTNING ARRESTERS ON EXIST

PRIMARY LINE CABLE RISER SET, TERMINATION KITS, FUSE

INTERCEPT EXIST O/H PRIM LINE W/ NEW UNDERGROUND

A

B

EXIST O/H PRIM. LINE

3PH, 4W, 11.4KV, 60HZ SYSTEM

(TYPICAL)

AND ASSOCIATED DEVICES

MOUNTED TRANSFORMERS

(TYPICAL)

P /S

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-2

O /H

REMOVE EXIST O/H PRIM. & SEC. LINE

3-1/C, #1, 15KV, "XLP" AND 1/C, #1, 600V, "XLP"

(TYPICAL)

NEW U/G PRIM. LINE

4-AWG#3/0 IN 103C

NEW U/G SEC. LINE

DISTRIBUTION PLAN-2

EXIST/NEW EXTERIOR POWER LINE

REMOVE EXIST H-FRAME POLE

P1

P2

P1 P2, TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

E-4

ACCESSORIES, GUY WIRE

ELECRICAL

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE:

1/300

PRIMARY POLE/

CUTOUT SWITCHES, LIGHTNING ARRESTERS ON EXIST

PRIMARY LINE CABLE RISER SET, TERMINATION KITS, FUSE

INTERCEPT EXIST O/H PRIM LINE W/ NEW UNDERGROUND

PROVIDE NEW PAD MOUNTED

DEAD-FRONT TYPE, LOAD BREAK SW,

W/BUILT-IN PROTECTIVE DEVICES (40A FUSE)

ACCESSORIES

REMOVE EXIST ELEC POLE

TO EXIST ELEC POLE

SECONDARY LINE, COMMUNICATION LINE, EXTERIOR LIGHT

AND RE-ARRANGE/RE-CONNECT EXIST PRIMARY LINE,

AND ASSOCIATED DEVICES

MOUNTED TRANSFORMERS

2340 2330

B

H 4-350KCMIL IN 104 C.

SECONDARY SERVICE ENTRANCE (4SET OF

EXIST MANHOLE/ PROVIDE SPLICING FOR

EXIST O/H PRIM. LINE

3PH, 4W, 11.4KV, 60HZ SYSTEM

(TYPICAL)

3PH, 11.4KV-120/208V(DELTA-WYE), 60HZ, 500KVA

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-3

NEW U/G SEC. LINE

4SET OF 4-350KCMIL IN 103C

NEW U/G SEC. LINE

P S

U /G

P

S U /G

S

O/H

O /H

S

4-AWG#8 IN 53C

ON EXIST POLE

RECONNECT NEW SEC LINE TO EXIST SEC. LINE

NEW O/H 4-AWG#6 "WP"

NEW SEC RACK(4-SPOOLS)

3-1/C, #1, 15KV, "XLP" AND 1/C, #1, 600V, "XLP"

(TYPICAL)

NEW U/G PRIM. LINE

DISTRIBUTION PLAN-3

EXIST/NEW EXTERIOR POWER LINE

REMOVE EXIST H-FRAME POLE

P1

P1

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

E-5

ACCESSORIES.

EXIST SECONDARY LINE WITHNEW ASSOCIATED

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE: 1/300

8008T

2540T

BARRIER

DEAD-FRONT TYPE, LOAD BREAK SW,

W/BUILT-IN PROTECTIVE DEVICES (10A FUSE)

3PH, 11.4KV-120/208V(DELTA-WYE), 60HZ, 75KVA

RADIAL TYPE TRANSFORMER

PROVIDE NEW PAD MOUNTED

PRIMARY POLE/

CUTOUT SWITCHES, LIGHTNING ARRESTERS ON EXIST

PRIMARY LINE CABLE RISER SET, TERMINATION KITS, FUSE

INTERCEPT EXIST O/H PRIM LINE W/ NEW UNDERGROUND

AND ASSOCIATED DEVICES

MOUNTED TRANSFORMERS

(TYPICAL)

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-4

W/ NECESSARY ACCOSSORIES

RE-CONNECT PRIMARY AND SECONDARY LINE ON EXISTING POLE

NEW O/H SEC. LINE

4-AWG#8" "WP"

NEW O/H PRI. LINE

4-AWG#2/0 "WP"

O /H

O /H

P

P

O /H

S

O /H

3-1/C, #1, 15KV, "XLP" AND 1/C, #1, 600V, "XLP"

NEW U/G PRIM. LINE

(TYPICAL)

S O /H

4-AWG#3/0 IN 103C

NEW U/G SEC. LINE

DISTRIBUTION PLAN-4

EXIST/NEW EXTERIOR POWER LINE

REMOVE EXIST H-FRAME POLE

P1

ACCESSORIES

TO EXIST ELEC POLE

SECONDARY LINE, COMMUNICATION LINE, EXTERIOR LIGHT

AND RE-ARRANGE/RE-CONNECT EXIST PRIMARY LINE,

P1REMOVE EXIST ELEC POLE

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

E-6

ACCESSORIES.

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE: 1/300

2373T

DEAD-FRONT TYPE, LOAD BREAK SW,

RADIAL TYPE TRANSFORMER

PROVIDE NEW PAD MOUNTED

PRIMARY POLE/

CUTOUT SWITCHES, LIGHTNING ARRESTERS ON EXIST

PRIMARY LINE CABLE RISER SET, TERMINATION KITS, FUSE

INTERCEPT EXIST O/H PRIM LINE W/ NEW UNDERGROUND

AND ASSOCIATED DEVICES

MOUNTED TRANSFORMERS

EXIST O/H PRIM. LINE

3PH, 4W, 11.4KV, 60HZ SYSTEM

(TYPICAL)

3PH, 11.4KV-120/208V(DELTA-WYE), 60HZ, 300KVA

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-5

P

O /H

P P

O/H

O/H

S

P

P

O/ H

O /H

(TYPICAL)

EXIST O/H SEC. LINE

3-1/C, #1, 15KV, "XLP" AND 1/C, #1, 600V, "XLP"

NEW U/G PRIM. LINE

(TYPICAL)

4-AWG#4/0 IN 103C

NEW U/G SEC. LINE

DISTRIBUTION PLAN-5

EXIST/NEW EXTERIOR POWER LINE

REMOVE EXIST H-FRAME POLE

TO EXIST ELEC POLE

SECONDARY LINE, COMMUNICATION LINE, EXTERIOR LIGHT

AND RE-ARRANGE/RE-CONNECT EXIST PRIMARY LINE,

P1REMOVE EXIST ELEC POLE

ACCESSORIES

P1

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

E-7

ACCESSORIES.

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

1/300

SCALE:

W/BUILT-IN PROTECTIVE DEVICES (20A FUSE)

DEAD-FRONT TYPE, LOAD BREAK SW,

METAL ENCL, OIL-FILLED, SELF-COOLED,

RADIAL TYPE TRANSFORMER

PROVIDE NEW PAD MOUNTED

PRIMARY POLE/

CUTOUT SWITCHES, LIGHTNING ARRESTERS ON EXIST

PRIMARY LINE CABLE RISER SET, TERMINATION KITS, FUSE

INTERCEPT EXIST O/H PRIM LINE W/ NEW UNDERGROUND

AND ASSOCIATED DEVICES

MOUNTED TRANSFORMERS

3PH, 11.4KV-120/208V(DELTA-WYE), 60HZ, 150KVA(TYPICAL)

3PH, 4W, 11.4KV, 60HZ SYSTEM

EXIST O/H PRIM. LINE

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-6

P

O/H

O /H

O /H

S

S

4-AWG#4/0 IN 103C

NEW U/G SEC. LINE

3-1/C, #1, 15KV, "XLP" AND 1/C, #1, 600V, "XLP"

NEW U/G PRIM. LINE

(TYPICAL)

DISTRIBUTION PLAN-6

EXIST/NEW EXTERIOR POWER LINE

REMOVE EXIST H-FRAME POLE

TO EXIST ELEC POLE

SECONDARY LINE, COMMUNICATION LINE, EXTERIOR LIGHT

AND RE-ARRANGE/RE-CONNECT EXIST PRIMARY LINE,

ACCESSORIES

P1REMOVE EXIST ELEC POLE

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

E-8

P1

ACCESSORIES AND GUY WIRE.

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE: 1/300

DEAD-FRONT TYPE, LOAD BREAK SW,

METAL ENCL, OIL-FILLED, SELF-COOLED,

RADIAL TYPE TRANSFORMER

PROVIDE NEW PAD MOUNTED

ACCESSORIES.

EXIST SECONDARY LINE WITH ASSOCIATED

RECONNECT NEW SECONDARY LINE TO

PRIMARY POLE/

CUTOUT SWITCHES, LIGHTNING ARRESTERS ON EXIST

PRIMARY LINE CABLE RISER SET, TERMINATION KITS, FUSE

INTERCEPT EXIST O/H PRIM LINE W/ NEW UNDERGROUND

AND ASSOCIATED DEVICES

MOUNTED TRANSFORMERS

3PH, 11.4KV-120/208V(DELTA-WYE), 60HZ, 300KVA

(TYPICAL)

3PH, 4W, 11.4KV, 60HZ SYSTEM

EXIST O/H PRIM. LINE

EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN-7

O /H

S

U/G

P

S O /H

S O/H

S O /H

4-AWG#4/0 IN 103C

NEW U/G SEC. LINE

NEW O/H SEC. LINE

3-1/C, #1, 15KV, "XLP" AND 1/C, #1, 600V, "XLP"

NEW U/G PRIM. LINE

(TYPICAL)

S

REPLACE W/ NEW O/H SEC. LINE

(TYPICAL)

O /H

DISTRIBUTION PLAN-7

EXIST/NEW EXTERIOR POWER LINE

W/NECESSARY ACCESSORIES

4-AWG#4/0

RE-ARRANGE EXIST SIGNAL LINE

REMOVE EXIST O/H PRIM. LINE/

REMOVE EXIST H-FRAME POLE

TO EXIST ELEC POLE

SECONDARY LINE, COMMUNICATION LINE, EXTERIOR LIGHT

AND RE-ARRANGE/RE-CONNECT EXIST PRIMARY LINE,

ACCESSORIES

P1 P2,REMOVE EXIST ELEC POLES

P2 P1

NEW SEC. CON'C POLE(10M)

TRANSFORMERS ON FEEDER NO.1 WITH NEW

REPLACE DETERIORATED H-FRAME MOUNTED

CAMP CASEYTAK, YS

164139

E-9

ACCESSORIES.

T-1
E-1
E-2
E-3
E-4
E-5
E-6
E-7
E-8
E-9