A27_Drawing_files___138983___ELEC___RLFC.pdf

PDF 2 MB Posted

Attached to
Repair Sewage Plants
Solicitation number
W91QVN17R0130
Issued by

About this file

Drawing Elec RLFC

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G E

N E

R A

L N

O T

E S A

N D S

C O

P E O

F W

O R

K

L E

G E

N D

A B

B R

E V

IA

T

IO

N

E-001

(NEW WORK)

1. LIGHTING SYSTEM:

INSTALL NEW PENDENT MOUNTED TYPE LIGHT FIXTURES AND EMERGENCY

LIGHT FIXTURES.

2 INSTALL NEW WALL MOUNTED LIGHT SWITCHES.

2. POWER SYSTEM:

INSTALL NEW POWER CONNECTION WIRES, SAFETY SWITCH

AND MOTOR STARTER FOR MECHANICAL EQUIPMENT.

2 INSTALL NEW SURFACE MOUNTED PANELBOARDS.

3 INSTALL NEW GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE.

SECONDARY LINE.

EXTERIOR

L E G E N D

MINIMUM OR MINUTEMIN

SAFETY SWITCH

FLEXIBLE CONDUIT W/CONNECTORS

CONTROL CIRCUIT

FOR LIGHTING, POWER & AUXILIARY CIRCUIT

WIRING EXPOSED

FOR LIGHTING, POWER & AUXILIARY CIRCUIT

WIRING CONCEALED IN CEILING, WALL & FLOOR

DENOTES +1350 ABOVE FINISHED FLOOR OR GRADE

19diax3000mmLG W/WELDING CONNECTION

GROUND ROD, COPPER CLAD STEEL

JUNCTION BOX WITH BOX COVER

NEWEXISTREMOVAL DESCRIPTION

NORMALLY CLOSED

NORMALLY OPEN

TOXIC FREE AREA

KILO VOLT AMPERE

LIGHTNING ARRESTER

GROUND FAULT PROTECTION

UNDERGROUND

WEATHERPROOF

XFMR

W/

TRANSFORMER

WITH

AND

V

VA

WP

W

TFA

U/G

VOLT

VOLT AMPERE

WATT

REQUIREDREQ'D

STD

SW

TEL

SPEC

SEC

STANDARD

SWITCH

TELEPHONE

SECONDARY

SPECIFICATION

Q'TY

RCPT

GFP

PNLBD

PWR

PRIM

QUANTITY

RECEPTACLE

POWER

PRIMARY

PANELBOARD

N.O.

N.C.

O/H

PH

NO

MTG

OVERHEAD

PHASE

NUMBER

MOUNTING

MAG

MAX

LTG

KV

LA

KVA

MAGNETIC

MAXIMUM

LIGHTING

KILO VOLT

KILO CIRCULAR MIL

ALTERNATING CURRENT

CIRCUIT BREAKER

BARE COPPER

AMERICAN WIRE GAUGE

AMPERE FRAME/AMPERE TRIP

CURRENT TRANSFORMER

HORSE POWER

INCANDESCENT

JUNCTION BOX

ABBREVIATION

FLUORESCENTFLUOR

INSTL

KCMIL

J-BOX

K

INCAND

HZ

INSTALLATION

KILO

HERTZ

FXTR

GND GROUND

FIXTURE

DRAWING(S)DWG(S)

EXIST

ENCL

EA

EM

EXISTING

EMERGENCY

ENCLOSURE

EACH

DIST

DISC

DET(S)

CONN

CT

DISCONNECT

DISTRIBUTION

DETAIL(S)

CONNECTION

AWG

C

CKT

CB

BLDG

BRKR

BC

CONDUIT

CIRCUIT

BUILDING

BREAKER

AF/AT

A

AC

AMPERE

HP

ABOVE FINISHED FLOORAFF

PULL BOX

"4" INDICATED CIRCUIT NUMBER

"M" INDICATED PANELBOARD NAME

HOMERUN CIRCUIT TO PANELBOARD

M-4

CONTROL PANEL (UNDER CIVIL ITEM)

PUMP (UNDER CIVIL ITEM)

SCOPE OF WORK

P

INTERIOR

LIGHTING

NEWEXISTREMOVAL DESCRIPTION

WIRING

FLUORESCENT LIGHT FIXTURE,

RATED WATT & TYPE OF MTG ON LTG SCHEDULE

FLUORESCENT LIGHT FIXTURE, RATED WATT & TYPE OF MTG

ON LTG SCHEDULE W/EMERGENCY BATTERY & SUPPLY UNIT

SINGLE FACE WALL MOUNTED EXIT LIGHT FIXTURE

TOGGLE SWITCH, 1POLE-15A-125V S

POWER

WALL MOUNTED METAL HALIDE LIGHT FIXTURE

DRY TYPE TRANSFORMERDTR

PANELBOARD

PUMP (UNDER MECH ITEM)P

2P-3W-20A-125V

GROUND FAULT PROTECTED DUPLEX RECEPTACLE,

CONCRETE ENCASEMENT DUCT

P

SEPARATE GROUNDING CONDUCTORS SHALL BE PROVIDED FOR ELECTRICAL

EQUIPMENT AND RECEPTACLES UNLESS OTHERWISE INDICATED ON THE DRAWING.

USE OF RIGID STEEL CONDUIT SHALL BE ALSO USED WITHIN 1500mm PRIOR TO PENETRATING

THE CONDUIT SHALL BE INSTALLED 1219mm BELOW GRADE.

ALL UNDERGROUND CONDUITS UNDER PAVED ROAD SHALL BE ENCASED WITH CONCRETE UNLESS

INDICATES 5#12 AWG & 1#12(G) IN 21C

INDICATES 4#12 AWG & 1#12(G) IN 16C

INDICATES 3#12 AWG & 1#12(G) IN 16C

OTHERWISE INDICATED ON THE DRAWING.

ALL CONDUITS FOR INTERIOR ELECTRICAL WIRES SHALL BE RIGID STEEL CONDUIT UNLESS

OTHERWISE INDICATED ON THE DRAWING.

ALL ELECTRICAL MATERIAL AND WORKMANSHIP SHALL COMPLY WITH ALL THE REQUIREMENTS OF

NATIONAL ELECTRICAL CODE 2017 EDITION AND NATIONAL ELECTRICAL SAFETY CODE IEEE C2- 2012.

ENERGY EFFICIENT FLUORESCENT LIGHTING FIXTURES SHALL BE UTILIZED FOR MOST INTERIOR

SPACES. 1200mm(4 FEET) FULL SIZE LINEAR FLUORESCENT LIGHTING FIXTURES SHALL BE EQUIPPED

WITH ENERGY SAVING LAMP(S) 28WATT(T-5) WITH A MINIMUM CRI OF 70 AND 3500K.

INDICATES 6#12 AWG & 1#12(G) IN 21C

THE GOVERNMENT RESERVES THE RIGHT TO POSTPONE THE REQUESTED POWER OUTAGE UP TO

14 DAYS PRIOR TO THE ANY SCHEDULED POWER OUTAGE.

THE CONTRACTOR SHALL NOTIFY CONTRACTING OFFICE, AND DPW IN WRITING A MINIMUM OF

8 HOURS PRIOR TO REQUESTED POWER OUTAGE.

AUTHORIZED PERSONNEL DURING FINAL INSPECTION IN FINISHED STATE PER NEC 300.23 AND 314.29

ALL ELECTRICAL JUNCTION BOXES, PULL BOXES, WIRING TRAYS, AND etc. SHALL BE ACCESSIBLE TO

GENERAL NOTES

ANY NEW CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES 2#12AWG WIRES AND 1#12(G) IN 16C

A GREATER NUMBER OF WIRES ARE INDICATED AS FOLLOWS:

A-1.

ALL MEASUREMENTS ARE METRIC "mm" UNLESS OTHERWISE INDICATED ON THE DRAWING.

AND PASSING THROUGH BLDG CONCRETE SLAB SHALL BE RIGID STEEL CONDUIT.

ALL UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC CONDUITS EXCEPT ANY PENETRATING

CONCRETE SLAB.

DEVICES. THE CHANGES SHALL BE APPROVED BY THE CONTRACTING

PROVIDE THE REQUIRED WIRING AND OVER CURRENT PROTECTION

THEN THE CONTRACTOR SHALL BE RESPONSIBLE TO RESIZE AND

IF EQUIPMENT OTHER THAN INDICATED ON THE PLANS ARE PROVIDED,

NOTED ON THE DRAWINGS.

MOUNTING HEIGHTS ABOVE THE FINISHED FLOOR SHALL BE AS FOLLOWS UNLESS OTHERWISE

LIGHT FIXTURE

RCPT

MOTOR CONTROLLER

SAFETY SWITCH

WALL SWITCH

PANELBOARD 1976 mm (6-FEET 6-INCH) TO THE HIGHEST HANDLE

1219mm (4-FEET) TO THE BOTTOM OF ENCL.

457mm (18-INCH) TO THE BOTTOM OF ENCL.

1524mm (5-FEET) TO CENTER OF THE ENCL.

1524mm (5-FEET) TO CENTER OF THE ENCL.

SEE LIGHTING FIXTURE SCHEDULE

OF CIRCUIT BREAKER OF PANELBOARD (MAXIMUM).

DURING THE CONSTRUCTION WHEN CONTRACTOR FOUND UNKNOWN EXISTING UNDERGROUND

WITH BCE AND ELEC UTILITY SHOP.

POWER CABLES IN THE PROJECT SITE, ANY REMOVAL OR RELOCATION WORK SHALL BE COORDINATED

ALL CONDUIT AND CONDUCTORS PENETRATING FIRE RATED WALLS SHALL BE FIRESTOPPED.

CONTRACTOR SHALL VERIFY ELECTRICAL REQUIREMENT OF EQUIPMENT

PRIOR TO INSTALLING THE ASSOCIATED CIRCUIT BREAKER, CONDUIT &

A-2.

A-3.

A-4.

A-5.

A-6.

A-7.

A-8.

A-9.

B-1.

C-1.

D-2.

D-3.

D-4.

A. GENERAL SYSTEM

B. GROUNDING SYSTEM

C. LIGHTING SYSTEM

D. POWER SYSTEM

SHOWING ROOM NUMBER PER CIRCUIT AFTER COMPLETE INSTALLATION.

THE CONTRACTOR SHALL PROVIDE EACH PANELBOARD SCHEDULE D-7.

FOR ANY CONTROL WIRINGS AND DEVICE LOCATIONS, SEE MECHANICAL

ALL EQUIPMENT CONTROL WIRING SHALL BE #14 AWG "TW" IN 16C UNLESS

OTHERWISE INDICATED.

D-8.

REMOVAL OF EXISTING ELECTRICAL DISTRIBUTION SYSTEM EQUIPMENT SHALL INCLUDE EQUIPMENT'S

ASSOCIATED WIRING, INCLUDING CONDUCTORS, CABLES, EXPOSED CONDUIT, SURFACE METAL

RACEWAYS, BOXS, AND FITTINGS, BACK TO EQUIPMENT'S POWER SOURCE.

D-1.

THE GRADING LINE OF NEW DUCTS WILL BE LIMITED TO THE WIDTH OF DUCT EXCAVATION.

SODDING, UTILITIES, STRUCTURES, ANY EXTERIOR WALLS/FLOORS TO THEIR ORIGINAL CONDITION

THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED AREA INCLUDING

AND OPERATION DURING AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.

A-11.

PROVIDE ARC FLASH WARNING LABELS ON ELECTRICAL EQUIPMENT

ENERGIZED. PROVIDE LABELS IN ACCORDANCE WITH THE FORMAT

LIKELY TO REQUIRE EXAMINATION, SERVICING OR MAINTENANCE WHILE

D-5.

SHOCK, ARC FLASH, AND ARC BLAST HAZARD APPROPRIATE

INJURY OR DEATH.

PPE REQUIRED FAILURE TO COMLPLY CAN RESULT IN

WARNING!

REFER TO UFC 3-560-01

ON CONC SLABS SHALL NOT BE OVERLAPPED. CONDUITS EMBEDDED IN CONCRETE WALLS AND

CONDUITS LARGER THAN 27mm(1") SHALL NOT BE INSTALLED IN CONC FLOOR OR WALL. CONDUITS

CONCRETE FLOOR SLAB.

ELECTRICAL CONDUITS SIZES 27mm(1") DIAMETER OR SMALLER ARE ALLOWED TO BE EMBEDED INA-10.

FLOORS SHALL NOT HAVE MORE THAN TWO(2) 90 DEGREE BENDS BETWEEN PULL BOXES.

ENTRY CONDUITS SHALL EXTEND BETWEEN FOUR TO SIX INCHES ABOVE THE

FINISHED FLOOR TO AID IN PULLING CABLES AND SHALL BE PLACED WITHIN

THREE INCHES OF THE WALL.

A-15.

CONTRACTOR SHALL INSTALL ALL ELECTRICAL WALL BOXES FLUSH OR RECESSED .A-16.

FLUSH-MOUNTED PANELBOARDS, PROVIDE SPACE CONDUITS EXTENDING

UP ABOVE THE CEILING AND DOWN BELOW RAISED FLOORS WHEN

APPLICABLE. PROVIDE ONE CONDUIT, MINIMUM OF 3/4 INCH, FOR EVERT

D-6.

AFTER COMPLETE INSTALLATION OF THE INTERIOR ELECTRICAL SYSTEM,

INSPECT THE SYSTEM VISUALLY AND PERFORM THE TEST OF EACH

ELECTRICAL SYSTEM AND ITS MAJOR EQUIPMENT. THEN PROVIDE THE

TESTING RESULTS WITH AT LEAST A COUPLE OF A4 SIZE PAPER BRIEFLY

OPERATION OF SYSTEM, INSULATION OF MAIN FEEDERS, CIRCUIT

BREAKER & RELAY SETTINGS AND GROUND FAULT PROTECTION IN THE

TO THE DPW (OR BCE) OR USING AGENCY. THE TEST SHALL INCLUDE THE

D-9.

AFTER COMPLETE INSTALLATION OF THE EXTERIOR ELECTRICAL SYSTEM,

INSPECT THE SYSTEM VISUALLY AND PERFORM THE TEST OF

UNDERGROUND ELECTRICAL SYSTEM AND ITS MAJOR POWER EQUIPMENT.

SIZE PAPER BRIEFLY TO THE DPW (OR BCE) OR USING AGENCY.

UNDERGROUND CABLES, FUSE OR BREAKER SETTINGS IN THE

THE TEST SHALL INCLUDE THE OPERATION OF SYSTEM, INSULATION OF

D-10.

SWITCHGEAR, RELAY SETTINGS ON THE POWER DISTRIBUTION LINES, etc.

FOR FLUORESCENT LIGHTING FIXTURE, IN THE LOCATIONS OTHER THEN DWELLINGS, PROVIDE

REQUIREMENT OF NEC 410. 130(G)

C-2

DOUBLE-ENDED LAMPS AND INTERNAL OR EXTERNAL DISCONNECT SWITCHTO MEET THE

UNDERGROUND SECONDARY LINE

THEN PROVIDE THE TESTING RESULTS WITH AT LEAST A COUPLE OF A4

MAIN SWITCHBOARD, etc.

DRAWINGS.

THREE EMPTY SPACE.

SHOWN IN FIGURE BELOW.

OFFICE.

WIRING.

P

P

ELEC UNIT HEATER (UNDER MECH ITEM)EUH

EXH FAN (UNDER MECH ITEM)EF

FLUORESCENT LIGHT, WALL MOUNTED,

RATED WATT ON LTG SCHEDULE

MAGNETIC MOTOR STARTER

TELEPHONE MANHOLEH

PAD MOUNTED TRANSFORMER

G GENERATOR

PANELBOARD OR LOADCENTER

WATT HOUR METER AND WIRING IN THE BUILDING.

J

C

+1350

J

PP

J

(REPAIR AND MAINTENANCE WORK)

1. EXTERIOR POWER SYSTEM:

REPLACE PAD MOUNTED TRANSFORMER AND UNDERGROUND

REPLACE POWER SERVICE SYSTEM INCLUDING NEW CT'S BOX,

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

NUMBER

IDENTIFICATION

SHEET

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

C O

N T

R A

C T N

O

Sheet of

S E

T

ID

A

P R

Y I, I

K

IMCOM

E N

G

IN

E E

R

IN

G D

IV

IS

IO

N

D P

W

A R

M Y G

A R

R

IS

O N

R E

D C

L O

U D

H

A D

Q U

A R

T E

R S

U N

IT

E D S

T A

T

S

M A

N A

G E

M E

N T C

O M

M A

N D

U S A

R M

Y I

N S

T A

L L

A T

IO

N

P A

R T

M E

N T O

F T

H E A

R M

Y

D P

W

U S

A G -R

E D C

L O

U D A

R E

A I

K O

R E

A

B L

D G S -1

R L F

C C

P C

A S

E Y

F E

W R

R E

P A

IR

R

E P

L A

C E S

E W

A G

E P

L A

N T

(B L

D G

R L F

C

AND PROVIDE NEW CONCRETE

POLE "P1" (14m-500kg)

INTERCEPT EXIST O/H PRIM LINE

H

WASTE WATER PLANT

TO REMAIN

EXIST PAD MOUNTED TRANSFORMER

3PHASE, 120/208V, 112.5KVA

NEW PANELBOARD "P"

1WAY: 4#1

NEW 2WAY OF U/G 103dia

PVC CONC ENCASED DUCT

1WAY: SPARE W/PULL WIRE

NEW PAD MOUNTED TRANSFORMER METAL ENCL,

OIL-FILLED, LOAD BREAK SWITCH, SELF-COOLED, DEAD FRONT,

LOOP FEED TYPE, 3PH, 4W, 60HZ, 75KVA (4%Z)

22.9KV-120/208V W/BUILT-IN PROTECTIVE DEVICES (6A)

(1200mmx1200mmx1200mmD)

NEW ELECTRICAL HANDHOLE

NEW U/G PRIM. LINE

3-1/C, #1, "XLP", 25KV & 1-1/C, #1 "XLP", 600V

IN 103dia PVC CONC ENCASED DUCT

W H

M

NEW ADVANCED DIGITAL WATTHOUR METER,

FOR 3PH, 4WIRE, 120/208V, 60Hz

AND 15 MINUTES DEMAND REGISTER

TRANSFORMER TYPE, W/CT 100/5Ax3EA

NEMA 3R ENCL

.5

S-1264

S-1263

S-1262

UP

W

C O

A/G

EXIST O/H PRIMARY LINE (TYPICAL)

EXIST CONCRETE POLE

EXIST DOWN GUY

EXIST U/G SECONDARY LINE

1/100SCALE :

NEW EXTERIOR ELECTRICAL DISTRIBUTION PLAN

SCALE: 1:100

0 1000 2000 4000

& SCOPE OF WORK,

FOR ABBREVIATION, LEGEND, GENERAL NOTES

NOTE

SEE SHEET NO. E-001, E-002 & E-003.

1.

N E

W E

X T

E R

IO

R

ES101

E L E

C T

R

IC

A L D

IS

T R

IB

U T

IO

N P

L A

N

N

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

NUMBER

IDENTIFICATION

SHEET

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

C O

N T

R A

C T N

O

Sheet of

S E

T

ID

A

P R

Y I, I

K

IMCOM

E N

G

IN

E E

R

IN

G D

IV

IS

IO

N

D P

W

A R

M Y G

A R

R

IS

O N

R E

D C

L O

A D

Q U

A R

T E

R S

U N

IT

E D S

T A

T

N A

G E

M E

N T C

O M

M A

N D

U S A

R M

Y I

N S

T A

L L

A T

P A

R T

M E

N T O

F T

H E A

R M

Y

D P

W

U S

A G -R

E D C

L O

U D A

R E

A I

K O

R E

A

B L

D G S -1

R L F

C C

P C

A S

E Y

F E

W R

R E

P A

IR

R

E P

L A

C E S

E W

A G

E P

L A

N T

(B L

D G

R L F

W L

IG

H T

IN

G P

L A

N

EL101

NEW LIGHTING PLAN

SCALE : 1/50

N

NS-4b 2/28 6

NS-4a 2/28 6

1/32NS-5FLUOR ABOVE THE DOOR TOP1

PENDENT MOUNTED123 MECH RM

1 ABOVE THE DOOR TOP, SINGLE FACENS-3 4.99 WALL MOUNTED

- EXTERIOR LIGHTS

FLUOR

TYPE

LIGHT FIXTURE SCHEDULE

OCE STD DET 40-06-04ROOM

NO NAME

LAMP

TYPE

MOUNTING METHOD

WATTS

Q'TY REMARKS

EXIT LIGHTS- LEDLED

D E

T A

IL

S A

N D S

C H

E D

U L E

SCALE: 1:50

0 500 1000 2000

FOR ABBREVIATION, LEGEND, GENERAL NOTES1.

& SCOPE OF WORK,

SEE SHEET NO. E-001

NOTE

NS-3 NS-4a & 4b

WITH BATTERY CHARGER DUAL-LITE CAT NO

WHITE HOUSING, RED LETTERS, BATTERY BACK-UP

EXIT LIGHT FIXTURE, 1PH, 120V, 4.99W (MAX.INPUT)

WALL MOUNTED LIGHT EMITTING DIODE(LED)

"LED1EMRWW" OR APPROVED EQUAL.

WALL MOUNTED FLUORESCENT LIGHTS FIXTURE,

1PH, 120V, 1/32WATT LAMP, LITHONIA LIGHTING

CAT NO "VR1B-32TRT-120-LPI" OR APPROVED EQUAL.

NS-5

HOUSING FORMED FROM IMPACT RESISTANT, FIBERGLASS

PENDENT MOUNTED FLUORESCENT LIGHT FIXTURE

(NS-4a) WITH EM UNIT (NS-4b), OR APPROVED EQUAL.

DETAILS

NOT TO SCALE

SCHEDULE

NOT TO SCALE

G R

O U

N D F

L

MH: +6500mm AFF, W/ "EM" UNIT

MH: +6500mm AFF

REINFORCED POLYESTER WITH COLD-ROLLED STEEL

ENCLOSED WIREWAY, 1PH, 120V, 2/28W LAMP

WHM

ROOM

SEDIMENTATION

COAGULATING

CHEMICAL

a b b a a a a aa a a a a a a

C

D

B

A

1 2

P-7

NEW ADVANCED DIGITAL WATTHOUR METER,

FOR 3PH, 4WIRE, 120/208V, 60Hz

AND 15 MINUTES DEMAND REGISTER

TRANSFORMER TYPE, W/CT 100/5Ax3EA

NEMA 3R ENCL

NEW PANELBOARD "P"

WP

WP

S S

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

NUMBER

IDENTIFICATION

SHEET

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

C O

N T

R A

C T N

O

Sheet of

S E

T

ID

A

P R

Y I, I

K

IMCOM

E N

G

IN

E E

R

IN

G D

IV

IS

IO

N

D P

W

A R

M Y G

A R

R

IS

O N

R E

D C

L O

A D

Q U

A R

T E

R S

U N

IT

E D S

T A

T

N A

G E

M E

N T C

O M

M A

N D

U S A

R M

Y I

N S

T A

L L

A T

P A

R T

M E

N T O

F T

H E A

R M

Y

D P

W

U S

A G -R

E D C

L O

U D A

R E

A I

K O

R E

A

B L

D G S -1

R L F

C C

P C

A S

E Y

F E

W R

R E

P A

IR

R

E P

L A

C E S

E W

A G

E P

L A

N T

(B L

D G

R L F

W P

O W

E R P

L A

N A

N D O

N E -L

IN

E D

IA

G R

A M

EP101

NEW POWER PLAN

SCALE : 1/50

N

NEW POWER ONE-LINE DIAGRAM

NOT TO SCALE

EXIST CONC POLE

GND S N

3P

100AF

100AT

#6 "BC" IN 27C

NEW GROUND ROD

19dia x 3000LG WITH WELDING

COPPER CLAD STEEL

CONNECTION

EXT.

(TYPICAL)

NEW CONDUIT COUPLING

(TYPICAL)

EXIST O/H PRIMARY LINE (TYPICAL)

CONDUCTOR, #6(G) IN 27C

NEW GROUNDING

WHM

4#1 IN 103C

SECONDARY LINE

NEMA 3R ENCL

3PH, 4W, 120/208V, 60HZ

SURFACE MOUNTED TYPE,

NEW PANELBOARD "P"

IN 103dia PVC CONC ENCASED DUCT

NEW U/G PRIM. LINE

3-1/C, #1, "XLP", 25KV & 1-1/C, #1 "XLP", 600V

1WAY: 4#1

NEW 2WAY OF U/G 103dia

PVC CONC ENCASED DUCT

1WAY: SPARE W/PULL WIRE NEMA 3R ENCL

TRANSFORMER TYPE, W/CT 100/5Ax3EA

AND 15 MINUTES DEMAND REGISTER

FOR 3PH, 4WIRE, 120/208V, 60Hz

NEW ADVANCED DIGITAL WATTHOUR METER,

NEW PAD MOUNTED TRANSFORMER METAL ENCL,

OIL-FILLED, LOAD BREAK SWITCH, SELF-COOLED, DEAD FRONT,

LOOP FEED TYPE, 3PH, 4W, 60HZ, 75KVA (4%Z)

22.9KV-120/208V W/BUILT-IN PROTECTIVE DEVICES (6A)

BY THE CONTRACTOR FOR FUTURE MANUFACTURER'S CABLING.

BUT EMPTY CONDUITS WITH PULL WIRE SHALL BE PROVIDED

SHALL BE FURNISHED AND INSTALLED BY THE MANUFACTURER.

CONTROL AND POWER CABLES FOR PUMPS2.

FOR ABBREVIATION, LEGEND, GENERAL NOTES

NOTES

1.

& SCOPE OF WORK, SEE SHEET NO. E-001

SCALE: 1:50

0 500 1000 2000

H(1200mmx1200mmx1200mmD)

NEW ELECTRICAL HANDHOLE

NEW CONC. POLE 14M-500Kg

WITH POLEKEY ASSEMBLY

EXIST DOWN GUY

3PHASE, 120/208V, 112.5KVA

EXIST PAD MOUNTED TRANSFORMER

TO REMAIN

3P

100AF

60AT

3P

100AF

20AT

P-3

1P

100AF

20AT

3P

100AF

20AT

P-5

1P

100AF

20AT

1P

100AF

20AT

1P

100AF

20AT

3P

100AF

30AT

P-4 P-6P-1 P-2 P-7

1P

100AF

20AT

1P

100AF

20AT

SPARE SPARE SPARE

B

A

1 2

C

D

P-2

P-1

P-3

P-5

P-5

P-5

P-4

P-4

P-6

P-6

P-6

P-6

P-6

P-6

CP#1

WHM

ROOM

SEDIMENTATION

COAGULATING

CHEMICAL

SLUDGE PUMP

3PH-200V-2HP x 2EA

(UNDER CIVIL ITEM)

(UNDER CIVIL ITEM)

1PH-115V-1/4HP x 6EA

CHEMICAL PUMP

MIXING AGITATOR

3PH-200V-1HP x 3EA

(UNDER CIVIL ITEM)

(3EA : STAND-BY)

MH: +1900mm AFF

(TYPICAL)

(1EA : STAND-BY)

MH: +4600mm AFF

NEUTRALIZATION AGITATOR

3PH-200V-1HP

(UNDER CIVIL ITEM)

MH: +4600mm AFF

FLOCCULATION AGITATOR

3PH-200V-1HP

(UNDER CIVIL ITEM)

EUH-1

J

EF-1

HEATING : 3PH-208V-5KW

ELECTRIC UNIT HEATER-1

FAN: 3PH-208V-1/100HP

W/BUILT-IN CONTROLLER

& DISC SW

(UNDER MECH ITEM)

A 3-POSITION SELECTOR SWITCH(H-O-A) AND

2P-120V, NEMA SIZE "0" W/O.L RELAYS

CIRCUIT BREAKER TYPE

COMB. MAGNETIC MOTOR STARTER,

(TYPICAL)

(TYPICAL)

COAGULATION AGITATOR

3PH-200V-1HP

(UNDER CIVIL ITEM)

MH: +4600mm AFF

P-3

P-2

P-4

A P-5

VIA

SEE NOTE 2 BELOW.

(UNDER CIVIL ITEM)

CONTROL PANEL #1

SEE NOTE 2 BELOW.

CONDUIT W/PULL WIRE

PROVIDE NEW 16C EMPTY

P-1

"WP" TYPE, GFCI DUPLEX

RECEPTACLE

(2P-3W-20A-125VAC)

(TYPICAL)

WP

WP

WP

WP

WP

P-6

(UNDER MECH ITEM)

1PH-115V-1/2HP

NEW EXH FAN-1

W/BUILT-IN DISC SW

NEMA 3R ENCL

TRANSFORMER TYPE, W/CT 100/5Ax3EA

AND 15 MINUTES DEMAND REGISTER

FOR 3PH, 4WIRE, 120/208V, 60Hz

NEW ADVANCED DIGITAL WATTHOUR METER,

NEW PANELBOARD "P"

PILOT LAMP(GREEN), NEMA 4X ENCL

(1P-100AF-20AT, 10000 AIC SYM)

4#4 & 1#8 IN 35C

EUH-1

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

NUMBER

IDENTIFICATION

SHEET

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

C O

N T

R A

C T N

O

Sheet of

S E

T

ID

A

P R

Y I, I

K

IMCOM

E N

G

IN

E E

R

IN

G D

IV

IS

IO

N

D P

W

A R

M Y G

A R

R

IS

O N

R E

D C

L O

A D

Q U

A R

T E

R S

U N

IT

E D S

T A

T

N A

G E

M E

N T C

O M

M A

N D

U S A

R M

Y I

N S

T A

L L

A T

P A

R T

M E

N T O

F T

H E A

R M

Y

D P

W

U S

A G -R

E D C

L O

U D A

R E

A I

K O

R E

A

B L

D G S -1

R L F

C C

P C

A S

E Y

F E

W R

R E

P A

IR

R

E P

L A

C E S

E W

A G

E P

L A

N T

(B L

D G

R L F

138983E-001
138983EL101
138983EP101
138983ES101
ELEC-BLDG 883.pdf
150686E-001
150686EL101
150686EP101
150686EP111
150686EP601
150686EP602
150686ES101
150686ES102

File details come from the government source that posted it. Updated .