1 T - 1 1 OF 1 TITLE SHEET

CIVIL

T-1

TITLE SHEET

A

B C D

E F G H

SCHEDULE OF DRAWINGS

RING NO. RING NO.DWG. NO. DWG. NO.SHT. NO. SHT. NO.DESCRIPTION OF DRAWINGS DESCRIPTION OF DRAWINGSREF. NO. REF. NO.REVISION STATUS REVISION STATUS

SYMBOL BY

DESIGNED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR’G DIV

CHK’D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENERGY MANAGER

DEPARTMENT OF THE ARMY

US ARMY INSTALLATION MANAGEMENT COMMAND

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

UNIT #15707, APO AP 96258-5707

ENVIRONMENT

FORCE PROTECTION

CHOE, S M.

AS SHOWN

FEWR NO. 107195

WARRIOR BASE

WARRIOR BASE

107195

LOCATION PLAN

SITE LAYOUT PLAN AND SCOPE OF WORK

MISC. DETAILS

REPAIR PARKING AREA NEAR FIRE STATION AND MOTOR POOL

REPAIR PARKING AREA NEAR FIRE

STATION AND MOTOR POOL

JOINT LAYOUT PLAN

PCC PAVEMENT DETAIL

C - 1

C - 2

C - 3

C - 4

C - 5

C-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR’G DIV

DES

CHK’D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

DEPARTMENT OF THE ARMY

US ARMY INSTALLATION MANAGEMENT COMMAND

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

UNIT #15707, APO AP 96258-5707

CIVIL

WARRIOR BASE

THIS PROJECT

NOTE: THE CONTRACTOR’S HAUL ROUTE, STORAGE AND OPERATION AREA WILL

BE DESIGNATED BY THE DPW DURING THE SITE ORIENTATION.

WARRIOR BASE

WONJU

POHANG

MOKPO

TONGYEONG

SEOUL

DONGDUCHEON

UIJEONGBU

CHUNCHEON

1OSAN

DAEJEON

E A S T S E A

BUSAN

WAEGWAN

JINHAE

DAEGU

MUNSAN

W E S T

S E A

INCHEON

GWANGJU

NOT TO SCALE

L O C A T I O N M A P

GUNSAN

PYEONGTAEK

MASAN

N

- 1

SCALE: 1 / 1200

LOCATION PLAN

LOCATION PLAN

CHOE, S M.

H F/T

F /T

F /T

F /T

2173(LIGHT-16EA)

294 2170

206T

Fire Station

NEW TRASH BIN

Water Tank

33,000 GAL

120,000 GAL

Water Tank

Toilet

Waste Water

Treatment Plant

Water Treatment Plant

MAIN GATE

REPAIR PARKING AREA NEAR FIRE

STATION AND MOTOR POOL

107195

FEWR 107195

REPAIR PARKING AREA NEAR FIRE

STATION AND MOTOR POOL

C-2

AS SHOWN

CHOE, S M.

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR’G DIV

FORCE PROTECTION

CHK’D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

DEPARTMENT OF THE ARMY

US ARMY INSTALLATION MANAGEMENT COMMAND

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

UNIT #15707, APO AP 96258-5707

- 2

SCALE: 1 / 350

SITE LAYOUT PLAN

1:350

0 40M302010

SITE LAYOUT PLAN AND SCOPE OF WORK

- 5

N

- 4

WARRIOR BASE

REPAIR PARKING AREA NEAR FIRE

STATION AND MOTOR POOL

107195

MODIFY ONE(1) M/H TO MATCH

NEW PAVEMENT LEVEL. SEE

SCOPE OF WORK

SCHEDULE #1 (REPAIR/MAINTENANCE)

2. MODIFY ONE(1) M/H TO MATCH NEW

PAVEMENT LEVEL.

F/T

F /T

FUEL

TANK FUEL

TANK

C

70.00

.0

5.00

REPLACE PCC PAVEMENT W/ NEW,

APPROX. 5,120.0 SM. SEE

- 5

274 275 276

1. REPLACE PCC PAVEMENT W/ NEW.

REPLACE CON’C CURB,

APPROX. 63.0 LM. SEE

3. REPLACE CON’C CURB.

AC PAVEMENT AREA

C-3

AS SHOWN

CHOE, S M.

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR’G DIV

FORCE PROTECTION

CHK’D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

DEPARTMENT OF THE ARMY

US ARMY INSTALLATION MANAGEMENT COMMAND

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

UNIT #15707, APO AP 96258-5707

- 3

SCALE: 1 / 350

1:350

0 40M302010

SITE LAYOUT PLAN AND SCOPE OF WORK

N

WARRIOR BASE

REPAIR PARKING AREA NEAR FIRE

STATION AND MOTOR POOL

107195

F/T

F /T

FUEL

TANK FUEL

TANK

C

.0

5.00

274 275 276

5.00

5.00

.0

JOINT LAYOUT PLAN

R

R

R

R

R

R R R R R R R R R R

R

RRR

R R R

R

R

R

R R R R R R

RRR

RR

R R

R R

R R

R R R R R

R R

R

R

LEGEND :

EXPANSION JOINT

REINFORCED PCC

CONTRACTION JOINT

R

R

R

CONTRACTION JOINT,

APPROX. 1,645.0 LM.

EXPANSION JOINT,

APPROX. 222.0 LM

REINFORCED PCC CONCRETE,

APPROX. 885.0 SM.

CONTRACTION JOINT

NOTE; DOWEL DIAMETER AS INDICATED

THIS END OF DOWEL

D13 BARS @ 305 OC

DOWELED CONSTRUCTION JOINT

25mm DIA X 406mmL @ 305 OC

THIS END OF DOWEL

CONSTRUCTION JOINT SEALANT DETAIL

FNSH GRADE

25mm DIA X 400mmL @ 380 OC

THIS END OF DOWEL

EXST PCC PAVEMENT

TACK COAT

SECTION

SLAB REINFORCEMENT DETAIL

(ODD-SHAPED SLAB & MISMATCHED JOINT)

PLAN

NOT TO SCALE

DOWELED

EDGE OF PCC PAVEMENT

FOR PCC REINFORCED PAVEMENT ONLY

JOINT SEALANT

PAINT AND OIL

203 203

OR CONSTRUCTION JOINT

D13 BARS @ 305 OC EW

OR 300mm X 300mm X

13mm DIA WELDED WIRE FABRIC

OR 300mm X 300mm X

13mm DIA WELDED WIRE FABRIC

NOT TO SCALE

THICKENED EDGE EXPANSION JOINT

19mm PREFORMED JOINT FILLER

NOT TO SCALE

JOINT SEALANT

JOINT SEALANT

PAINT AND OIL

EXPANSION JOINT SEALANT DETAIL

NOT TO SCALE

BOND BREAKING TAPE OR

SEPARATING MATERIAL

(3mm WIDER THAN NOMINAL WIDTH OF JOINT)

19mm PREFORMED JOINT FILLER

POURED JOINT SEALANT

203 203

CAST-IN-PLACE OR

DRILL & GROUT DOWEL

NEW PCC PAVEMENT

NOT TO SCALE

POURED JOINT SEALANT

BOND BREAKING TAPE OR

SEPARATING MATERIAL

(3mm WIDER THAN

NOMINAL WIDTH OF JOINT)

BUTTED JOINT

BLDG & MANHOLES OR

OTHER STRUCTURES

203203

240mm THK PCC

SURFACE COURSE

JOINT SEALANT

NOT TO SCALE

TRANSITION FOR

THICKENED EDGE

EXST AC SURFACE COURSE

EXST BASE COURSE

EXST SUBBASE COURSE

240mm THK PCC PAVEMENT

350mm THK 100%%% COMPACTION BASE COURSE

THICKENED EDGE

NEW PCC/ EXST AC PAVEMENT JOINT

NOT TO SCALE

TYPICAL-PCC PAVEMENT SECTION

AND THICKENED EDGE

NOTE: 1. SEALANT DEPTH MUST BE 1.0 TO 1.5 TIMES THE WIDTH.

350mm THK 100% COMPACTION

BASE COURSE

EXPANSION JOINT BETWEEN

NEW/EXST PCC PAVEMENT

NOT TO SCALE

200 200

EXPANSION CAP SLIP FIT

NEW PCC PAVEMENT

DRILL & GROUT DOWEL

JOINT SEALANT

PAINT AND OIL

25.4mm DIA X 406mmL @ 305mm OC

.7

.4

75 MAX

107.3 +-12.7

T

O

T O

.5

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR’G DIV

FORCE PROTECTION

CHK’D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

DEPARTMENT OF THE ARMY

US ARMY INSTALLATION MANAGEMENT COMMAND

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

UNIT #15707, APO AP 96258-5707

- 4

SCALE: NONE

PCC PAVEMENT DETAIL

CHOE, S M.

CIVIL

C-4

AS SHOWN

PCC PAVEMENT DETAIL

NO.6-150X150 WWF

NO.6-150X150 WWF

NO.6-150X150 WWF

CONTRACTION JOINT

NOT TO SCALE

JOINT SEALANT

WWF #6 X #6 /150 X 150

NOT TO SCALE

CONTRACTION JOINT SEALANT DETAIL

BOND BREAKING TAPE OR

SEPARATING MATERIAL

(3mm WIDER THAN

NOMINAL WIDTH OF JOINT)

COMPRESSIBLE, NONSHRINKING, NONSTAINING,

NONREACTIVE TO SEALANT AND

NON-ABSORPTING FILLER MATERIAL

EXTRUDED BUTYL OR

POLYCHLOROPRENE FOAM RUBBER

3 (MIN)

T

O

T

O

13 TO 16

POURED JOINT SEALANT

4C

4D

4E

4F

4G

4H

4I

4J

4J1

4J2

4G

4G

4I

4H

4H

4J2

4G

4A

4B

REPAIR PARKING AREA NEAR FIRE

STATION AND MOTOR POOL

107195

EXISTING MANHOLE MODIFICATION

E X

S T

P O

R T

IO

N

T O

R E

M A

IN

1200200 200

ALL CONCRETE DUST, & RUST (TYP)

CLEAN EXISTING REBAR TO REMOVE

ROUGHEN, CLEAN &

TO POURING CONCRETE

APPLY EPOXY PRIOR

EXST REINFORCING

D10 BARS @ 300mm OC

NEW TOP OF MANHOLE

CI MANHOLE COVER OR STEEL GRATING COVER

E X

T E

N S

IO

N

L A

P S

P L

IC

E

V A

R

IE

S

TOP OF PAVED

CONC COLLAR

FIN GRADE

300 300

D10 BAR @ 200mm OC

D13 BAR @ 200mm OC

EXST TOP OF MH

- 5

SCALE: NONE

CIVIL

C-5

AS SHOWN

CHOE, S M. WARRIOR BASE

REPAIR PARKING AREA NEAR FIRE

STATION AND MOTOR POOL

107195

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR’G DIV

FORCE PROTECTION

CHK’D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

DEPARTMENT OF THE ARMY

US ARMY INSTALLATION MANAGEMENT COMMAND

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

UNIT #15707, APO AP 96258-5707

MISC. DETAIL

15025

AC PAVEMENT

R=13

10 THICK EXPANSION

JOINT W/ SEALER

SEE PLAN FOR FINISH

R R

NFSM

"C"

"C

CAST IN PLACE

CONCRETE CURB

21 MPa

NOTE ;

1. PROVIDE EXPANSION JOINTS AT MAX. 15.0 M.

INTERVALS (MATCH SIDEWALK)

2. "C" DIMENSION CONSTANT EQUALS PAVEMENT

SECTION MINUS 300.

3. CONCRETE COMPRESSIVE STRENGTH SHALL BE

21 MPa AT 28 DAYS.

EXISTING MANHOLE MODIFICATION1

- 5

SCALE: NONE

107195-1
107195-2
107195-3
107195-4
107195-5
107195-6

File details come from the government source that posted it. Updated .