A-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

36,224

13,001 16,920 6,303

,6

SCALE: 1/100

GROUND FLOOR PLAN

AREA

ADMIN.

AREA

ADMIN.

RD1

EXST ROLL UP DOOR

TO REMAIN (TYP)

ENGINE ROOM

EXST ROLL UP DOOR

TO REMAIN (TYP)

MANUFACTURES INDICATED.

PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE

COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.

ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).

CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS

FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR

CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE

SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD

8.

FOR APPROVAL.

CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR

OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR

SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE

2.

3.

4.

5.

6.

7.

CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER

IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT. THE GENERAL

AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION

OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE

APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION

9.

10.

11.

BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.

STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003 SHALL

NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD NO. 595b, COLORS.

COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY AND COLOR

ADDITIONAL COST TO THE GOVERNMENT.

EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT

THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,

ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR

THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED

GENERAL NOTES

1.

SCOPE OF WORKS (ARCHITECTURAL WORKS)

REPAIR / MAINTENANCE (K) WORKS

FOR BLDG NO. 803

REPAIR ROOL UP DOORS

CAMP RED CLOUDYI, SC

138583

RD2

OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR

SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE 12.

A-2

AND SCOPE OF WORKS

GROUND FLOOR PLAN, GENARAL NOTES

UP DOOR SLATS AND DOOR GUIDE RAILS AS SHOWN ON FLOOR PLAN, PICTURES AND DETAIL DRAWINGS.

AND CONNECT ELECTRICAL OPERATION SWITCH WITH WIRE-TYPE REMOTE CONTROL WITHOUT ROLL

MANUAL CHAIN, SAFETY SENSING EDGE, CONTROL PUSH BUTTON STATION "OPEN-STOP-CLOSE"

REPAIR BY REPLACE DETERIORATED EXISTING SHAFT, MOTOR, CASING HOOD & FRAME, EMERGENCY

A-2

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

DESCRIPTIONTYPESYMBOL

ROUGH OPENING

WIDTH HEIGHT

EA REMARKS

CASING HOOD

MANUAL CHAIN

EMERGENCY

EXIST WALL

D O

O R

H E

IG

T

M

T C

T O

E X

S T

RD1 4,380 4,160 1

RD2 2,850 4,160 1

SAFETY SENSING EDGE

SCALE:

ELEVATION

N/A

SCALE: N/A

TYPICAL SECTION

(INSIDE OF WALL)

MANUAL CHAIN

EMERGENCY

W/FRAME

CASING HOOD

ROLL UP DOOR SCHEDULE

SCALE:

PICTURE-1

N/A

SCALE:

PICTURE-2

N/A

REPAIR DAMAGED ROLL UP DOORS

WEATHERSTRIP

WITHOUT SLATS, GUIDE RAILS AND

SHAFT, MOTOR, HAND CHAIN, HOOD

REPLACE DAMAGED ALL PARTS INCL.

SCHEDULE AND NOTES

ELEVATION, SECTION, PICTURES,

FOR BLDG NO. 803

REPAIR ROOL UP DOORS

YI, SC CAMP RED CLOUD

138583

1.

2.

ROLL UP DOOR NOTES

MOTOR SHALL MEET UL 325, CSA APPROVAL

1 HP, 230V, 1PH, 60HZ

1 HP, 230V, 1PH, 60HZ

CONTROL PUSH BUTTON STATION ( OPEN-STOP-CLOSE) SHALL MEET NEMA-1

EXST SLAT

GUIDE RAIL

EXST STEEL

EXST SLATS

POWER OPERATORPOWER OPERATOR

SENSING EDGE, SWITCH WITHOUT SLATS, GUIDE RAILS AND WEATHERSTRIP

REPLACE DAMAGED ALL PARTS INCL. SHAFT, MOTOR, HAND CHAIN, HOOD,

SENSING EDGE, SWITCH WITHOUT SLATS, GUIDE RAILS AND WEATHERSTRIP

REPLACE DAMAGED ALL PARTS INCL. SHAFT, MOTOR, HAND CHAIN, HOOD,

138583-Repair roll up door, Bldg803, CRC-A-1
138583-Repair roll up door, Bldg803, CRC-A-2