A-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
36,224
13,001 16,920 6,303
,6
SCALE: 1/100
GROUND FLOOR PLAN
AREA
ADMIN.
AREA
ADMIN.
RD1
EXST ROLL UP DOOR
TO REMAIN (TYP)
ENGINE ROOM
EXST ROLL UP DOOR
TO REMAIN (TYP)
MANUFACTURES INDICATED.
PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.
ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).
CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS
FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR
CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE
SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD
8.
FOR APPROVAL.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR
OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE
2.
3.
4.
5.
6.
7.
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER
IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT. THE GENERAL
AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION
OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE
APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION
9.
10.
11.
BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.
STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003 SHALL
NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD NO. 595b, COLORS.
COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY AND COLOR
ADDITIONAL COST TO THE GOVERNMENT.
EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT
THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,
ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED
GENERAL NOTES
1.
SCOPE OF WORKS (ARCHITECTURAL WORKS)
REPAIR / MAINTENANCE (K) WORKS
FOR BLDG NO. 803
REPAIR ROOL UP DOORS
CAMP RED CLOUDYI, SC
138583
RD2
OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE 12.
A-2
AND SCOPE OF WORKS
GROUND FLOOR PLAN, GENARAL NOTES
UP DOOR SLATS AND DOOR GUIDE RAILS AS SHOWN ON FLOOR PLAN, PICTURES AND DETAIL DRAWINGS.
AND CONNECT ELECTRICAL OPERATION SWITCH WITH WIRE-TYPE REMOTE CONTROL WITHOUT ROLL
MANUAL CHAIN, SAFETY SENSING EDGE, CONTROL PUSH BUTTON STATION "OPEN-STOP-CLOSE"
REPAIR BY REPLACE DETERIORATED EXISTING SHAFT, MOTOR, CASING HOOD & FRAME, EMERGENCY
A-2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
DESCRIPTIONTYPESYMBOL
ROUGH OPENING
WIDTH HEIGHT
EA REMARKS
CASING HOOD
MANUAL CHAIN
EMERGENCY
EXIST WALL
D O
O R
H E
IG
T
M
T C
T O
E X
S T
RD1 4,380 4,160 1
RD2 2,850 4,160 1
SAFETY SENSING EDGE
SCALE:
ELEVATION
N/A
SCALE: N/A
TYPICAL SECTION
(INSIDE OF WALL)
MANUAL CHAIN
EMERGENCY
W/FRAME
CASING HOOD
ROLL UP DOOR SCHEDULE
SCALE:
PICTURE-1
N/A
SCALE:
PICTURE-2
N/A
REPAIR DAMAGED ROLL UP DOORS
WEATHERSTRIP
WITHOUT SLATS, GUIDE RAILS AND
SHAFT, MOTOR, HAND CHAIN, HOOD
REPLACE DAMAGED ALL PARTS INCL.
SCHEDULE AND NOTES
ELEVATION, SECTION, PICTURES,
FOR BLDG NO. 803
REPAIR ROOL UP DOORS
YI, SC CAMP RED CLOUD
138583
1.
2.
ROLL UP DOOR NOTES
MOTOR SHALL MEET UL 325, CSA APPROVAL
1 HP, 230V, 1PH, 60HZ
1 HP, 230V, 1PH, 60HZ
CONTROL PUSH BUTTON STATION ( OPEN-STOP-CLOSE) SHALL MEET NEMA-1
EXST SLAT
GUIDE RAIL
EXST STEEL
EXST SLATS
POWER OPERATORPOWER OPERATOR
SENSING EDGE, SWITCH WITHOUT SLATS, GUIDE RAILS AND WEATHERSTRIP
REPLACE DAMAGED ALL PARTS INCL. SHAFT, MOTOR, HAND CHAIN, HOOD,
SENSING EDGE, SWITCH WITHOUT SLATS, GUIDE RAILS AND WEATHERSTRIP
REPLACE DAMAGED ALL PARTS INCL. SHAFT, MOTOR, HAND CHAIN, HOOD,
| 138583-Repair roll up door, Bldg803, CRC-A-1 |
| 138583-Repair roll up door, Bldg803, CRC-A-2 |