4._Drawings_J1-00572-5J_TOTAL_rv1.PDF

PDF 21 MB Posted

Attached to
Conversion of Barrack to SEQ (Senior Enlisted Quarters), Bldg. #575, Camp Walker
Solicitation number
W91QVN16R0045
Issued by

About this file

Drawing_W91QVN16R0045

View the file

Other files

File Type Posted
W91QVN16R0045_Final.docx DOCX document
6._Submittal_Register_J1-00572-5J.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

R-11SHEET OF

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

O & M

HOUSING DIV.

REVIEWED BY

AS SHOWN

UNITED STATES ARMY GARRISON DAEGU

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

DIRECTORATE OF PUBLIC WORK

HGFEDCBA

T I T L E S H E E T

D - 15 - 30

O, KI TAL

CHON, HYON TAE

DESIGN REVIEW SIGNATURE

ORGANIZATION

USING AGENCY

36TH SIGNAL

MASTER PLN.

ENVIRONMENTAL

NAME SIGNATURE

O&M DIV.

FIRE DEPT.

SAFETY OFFICE

DPTMS(AT/FP)

188TH MP COM.

IND. HYGENIST

J1-00572-5J

UNIT #15746, APO AP 96218-5746

C - 1

R - 1

DRAWING NO.DATE: 29 JUL 15

C - 23

CHIEF,

DESIGN & TECH. REVIEW Br.

E - 1653

AE - 1

AE - 58

ARCHITECTURAL

AE - 710

AE - 811

AE - 912

E - 1

ELECTRICAL

CAMP WALKER

CIVIL

52 OF 52AE - 6

LOCATION PLAN

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

PROJECT NO. J1-00572-5J, CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. 575

CONVERSION OF BARRACK TO SEQ

AE - 25 4 OF 52

AE - 36 5 OF 52

AE - 47 6 OF 52

13 12 OF 52

14 13 OF 52

15 14 OF 52

16 15 OF 52

M - 1

MECHANICAL

19 18 OF 52

M - 220 19 OF 52

M - 321 20 OF 52

M - 422 21 OF 52

M - 523 22 OF 52

M - 624 23 OF 52

M - 725 24 OF 52

M - 826 25 OF 52

M - 927 26 OF 52

M - 1028 27 OF 52

M - 1129

M - 1230 29 OF 52

M - 1331

M - 1432 31 OF 52 NEW WET TYPE FIRE SPRINKLER SYSTEM PALN

M - 1533 32 OF 52

M - 1634 33 OF 52 ELEVATION, SECTION AND CONTROL DIAGRAM

M - 1735 34 OF 52

M - 1836 35 OF 52

M - 1937 36 OF 52

E - 239 38 OF 52 LIGHTING PLAN

E - 340 39 OF 52

E - 441

E - 542 41 OF 52

E - 643 42 OF 52

E - 744 43 OF 52

E - 845 44 OF 52

E - 946 45 OF 52

E - 1047 46 OF 52

E - 1148 47 OF 52

E - 1249 48 OF 52

E - 1350 49 OF 52

E - 1451 50 OF 52

E - 1552 51 OF 52

AE - 10

AE - 11

AE - 12

AE - 13

AE - 14

SITE LAYOUT PLAN

INTERIOR FINISH SCHEDULE AND EXTERIOR FINISH SCHEDULE

DOOR / WINDOW DETAILS (TYP)

GYPSUM BOARD CEILING DETAILS, SPLAYED WIRE BRACING DETAILS AND CEILING ACCESS DETAILS

LEGEND AND ABBREVIATIONS

EQUIPMENT SCHEDULE

SCOPE OF WORK

EXISTING HVAC REMOVAL PLAN

NEW HVAC PIPING PLAN

NEW HVAC PIPING ISOMETRIC DIAGRAM

NEW VENTILATING SYSTEM PLAN

NEW SEWER SYSTEM PLAN

NEW SEWER LINE ISOMETRIC DIAGRAM

NEW PLUMBING PLAN

1st FLOOR ENLARGED PLAN

2nd FLOOR ENLARGED PLAN

NEW MECH ROOM PARTIAL PLAN

DETAIL DRAWINGS

DETAIL DRAWINGS

DETAIL DRAWINGS

LEGEND, NOTES AND SCOPE OF WORKS

LIGHTING FIXTURE SCHEDULE, LIGHTING FIXTURE DETAILS AND EXTERIOR LTG. CONTROL DIAGRAM

POWER PLAN1

POWER PLAN2

ELECTRICAL POWER SINGLE LINE DIAGRAM AND ELECTRICAL POWER SITE PLAN

COMMUNICATION PLAN AND COMMUNICATION OUTLET DETAILS

COMMUNICATION SYSTEM SINGLE LINE DIAGRAM

COMMUNICATION SITE PLAN

CATV PLAN

FIRE ALARM PLAN

CCTV AND MNS PLAN

MECHNICAL ROOM ENLARGED PLAN AND PANEL SCHEDULE "MDP"

PANEL SCHEDULE "LS" AND PANEL SCHEDULE "LF"

PANEL SCHEDULE "K1", "K2", "MD"’ AND "LT"

TITLE SHEET

NEW PLUMBING ISOMETRIC DIAGRAM

FIRE ALARM SINGLE LINE DIAGRAM AND CATV SYSTEM SINGLE LINE DIAGRAM

18 AE - 15 17 OF 52

REMOVAL / EXISTING FLOOR PLAN, BLDG #575, NOTE, GENERAL NOTES, REMOVAL WORK AND LEGEND

NEW FLOOR PLAN BLDG #575, NOTE, SCOPE OF WORK AND LEGEND

ELEVATION, BLDG #575, ABBREVIATION, KEY PLAN, BLDG #575

CROSS SECTION, BLDG #575, TYPICAL WALL SECTIONS, AND KEY PLAN, BLDG #575

WALL SECTION DETAIL, AND KEY PLAN, BLDG #575

ENLARGED UNIT FLOOR PLAN, AND LEGEND

ENLARGED PARTIAL FLOOR PLAN, AND LEGEND

CABINET ELEVATIONS, SHOWER SOAP HOLDER DETAIL & HOOK DETAIL AND NOTE

2F BATH, FLOOR STRUCTURAL REINFORCEING PLAN, BATH & LAVATORY CABINET PLAN, BATH & LAVATORY

MOUNTING LOCATION OF SIGNAGE AND NOTE

KITCHEN CABINET ELEVATION, INSULATION / SIGNAGE / STRUCTURAL STEEL LOCATION PLAN, SIZE &

STAIR HANDRAIL DETAIL AND NOTE

EXISTINT STRUCTURAL STEEL COLUMN COVER DETAIL, CAGE DETAIL, 2ND FLOOR CORRIDOR GUARD RAIL DETAIL, DOOR AND WINDOW ELEVATIONS, SCHEDULE AND NOTE

CABINET DETAIL(TYP), UPPER CABINET DETAIL(TYP), AND DETAILS(TYP)

AC PAVED

A

C

R O

A D

W I

S C

O N

S I

N

S T

R E

E T

A

A D

H

F/T

T R

A S

H

S H

E D

T-158

GEORGIA STREET

A.C PAVED

RHODE ISLAND STREET

A

A D

APSAN OVERHEAD BRIDGE

X

X X

X

X

X

X

X

A.C ROAD

CONC PAD

S A

D

V

L L

E Y

B A

L L

LIMITED AREA

SHED

APSAN OVER BRIDGE

S H

E D

S H

E D

SHED

A

F

A N

C I

S

R E

E T

A

A N

C I

S

R E

E T

A S

N

F

R A

N C I S

C O

S

T R

E E

T

A S

N

F R

A N C I S C

O

S T R E E T

P

V E

D

A D

U T

A H

S

T R

E E

T

W I S

C O

N S I

N

S

T R

E E

T

U T

A H

S

T R

E E

T

U T

A H

S

T R

E E

T

T

TK

C

TK

C

C

TK

ETC

ETC

ETC

ETC

ETC

ETC

ETC

ETC

ETC

ETC

ETC

ETC

ETC

COVERE

D

BI

CYCL

E

RACK

BUS ONLY

STOP

S T O P

S

W

F A

M

IL

Y

H

U S

IN

G

W E

R

F F E

E L

.4

P A R

K

IN

G

S

T R

U C

T U

R E

B

IC

Y C

L E

SHED

F/H

F/H

E

CB

SP

S

SP

SP

SP

SP

SP

E

CB

CB

C B

C B

SP

C B

S

SP

E

E

PAD

CB

S

S

S

T E

X A S S

T R

E E

T

W

IS

C O

N S

IN

S

T R

E E T

IN

DI

ANA

STREET

S-398

S-363

S-373

S-372 S-367

S-409

T-392

T-391 T-390

T-235 Golf Course

S-468

T-445

S

T

S

S

T 9 S-470

S-457 T-465

T-466

S-450T-706

GATE 2

S-324

S-422

S-335

S-320

R H

O D

E

IS

L A

R

E E T

S-338

S 15S-200

S-216T-213

S-452

T-720 T-721

T-722

T-235 Golf Course

T-235 Golf Course

S-357

GATE 6

S-403

TMP Washrack

188TH MP S-431

S-430

T-433

S-441

GOLAN 10

T-442

S-414

S-411

S -416S

-410

T

S-440

S-711

T-712

S-358 T-364

S-356

T-355

S-349

S-408 T-421

S -420

S-353 S-399

S-350

S-352

T-342

T-387

S-701

S-348

T-235 Golf Course

W

IS

C O

N

IN

R

E E

T KELLY FIELD

S-252

S-283

S

S-205

S-208

S -2

S-261

S

S-260

S-202

S-217

S-212

S

S-222

S-382

S-362

T

T

S-360

S-368

S-386

S-38

S-

S-

S

S-

S

T-235 Golf Course

S-

S

S

S-

S-

S-

S-

S

S-

S

GEORGIA STREET

S-2

S-142

S

S-

S-

S-

S-

S

S-

S-148

S-149 S-163

T-164

S-165

S-166

S-565

U T A H

S T R E E T

R H

O D

E

IS

L A

N D

S T R E E T

TE

XAS

S

TR

EE

T

S

S

S-161

T-158

S-617

STREET

WASHINGTON

S-556

S-

S-5

S-57

S-57

S-574

S-585

S

S-557

S-182 S-555

S-556

S

S 1S-566

S

S

S

S-315

S

T-569

S-57

S-616

S-57

S-584

T-614

S-226

S-316

S

S -602

S-601

S

S

S

S

S-

S-

S

S

S

S-221

T-573

C A L

IF

O R

N

IA

S T R E E T

S

S-267

S-228

S

S-232

S-230

S-245

S-244

S-248

S-227

S-246

S-314

S-303

S-304

S-305

S-309

S-327

S-328

S-334

S-312

S-318

S

S-592

T-594

C A L

IF

O R

N

IA

S T R E E T

S

S

S-379

S-374

T

S-310

T-340

S-330

S-237

T-341

SUBSTATION

CDC

MIDDLE / HIGH SCHOOL

S-321

S-359

S-363

S-409

STOOP

WALL W/FENCE

WALL W/FENCE

WALL W/FENCE

WALL W/FENCE

TK

TK

C

TK

ETC

ETC

T-462

S-36

S-38 S-8

S-1

S-32

S-21 S-22

T-20

KU, HUN MO

CIVIL

AS SHOWN

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

YI, CHONG SON

LOCATION PLAN

1- SCALE : 1 / 3000

CAMP WALKER

D - 15 - 30

1 52 C-1

29 JUL 15

LOCATION PLAN

T

GRAPHIC SCALE

(IN METERS)

0 60 120

THIS PROJECT

2-

1SEE SITE LAYOUT PLAN

N

SCALE: 1 : 3000

J1-00572-5J

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

KU, HUN MO

CIVIL

AS SHOWN

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

YI, CHONG SON

C-2

GRAPHIC SCALE

LEGEND:

ELEC. POLE

E/P

ITEMS TO BE REMOVED

N

CAMP WALKER

J1-00572-5J

REMOVE EXISTING CONCRETE PAD

S/P REMOVE EXISTING SUMP

118.008BLDG

117.686S-WALK

117.291S-WALK

114.803GRATING

111.674GRATING

118.743GRATING

117.726GRATING

114.726AC

115.021AC

115.907AC

113.494AC

116.301AC

117.963HW

117.661SMH

118.273WALL

118.925MH

117.711TRANSFE

117.39EMH

EP

EP

EP

EP

EP

EP

BLDG#576

BLDG#575

SITE LAYOUT PLAN

SITE LAYOUT PLAN

117.977BLDG

117.728BLDG

117.936BLDG

118.007S-WALK

118.112S-WALK

117.919AC

117.888AC

117.84AC

117.856HW

117.963HW

118.003FENCE

118.194RETAINWALL

~A.C~

S/P

S/P

EP

WW

W

S

W

W

W

REMOVE EXISTING FUEL LINES

REMOVE EXISTING SUMP

REMOVE EXISTING SUMP

CONCRETE PAD

LEAK DETECTION SYSTEM AND

REMOVE EXISTING FUEL OIL TANK,

EXISTING WATER LINE (D=200)

SEE STANDARD DETAIL DRAWING C0420

INSTALL POST INDICATOR VALVE

SIDEWALK.

REMOVE/REPLACE EXISTING CONCRETE

GRATING COVERED CONCRETE DITCH

REMOVE/REPLACE EXISTING STEEL

SIDEWALK.

REMOVE/REPLACE EXISTING CONCRETE

SIDEWALK.

REMOVE/REPLACE EXISTING CONCRETE

TEMPORARY BENCH MARK

WATER LINE (ASSUMED)

EXISTING DOMESTIC

AND SUBBASE COURSE SAME AS EXIST

CONCRETE PAVEMENT, BASE COURSE

REMOVE/REPLACE EXISTING ASPHALT

AND SUBBASE COURSE SAME AS EXIST

CONCRETE PAVEMENT, BASE COURSE

REMOVE/REPLACE EXISTING ASPHALT

AND SUBBASE COURSE SAME AS EXIST

CONCRETE PAVEMENT, BASE COURSE

REMOVE/REPLACE EXISTING ASPHALT

AROUND SUMP

REMOVE EXISTING CONCRETE

F O

L

EXISTING STONE RETAINING WALL

C O

N

TAIN

ER

C O

N

TAIN

ER

REMOVE/REPLACE EXISTING CONCRETE SIDEWALK

PAVEMENT, BASE COURSE AND SUBBASE COURSE

REMOVE/REPLACE EXISTING ASPHALT CONCRETE

SCOPE OF WORK

#1 (CONSTRUCTION/ALTERATION)

C O

N C P A D

GRATING COVERED CONCRETE DITCH

REMOVE/REPLACE EXISTING STEEL

4000 8000

D

SEE STANDARD DETAIL DRAWINGS C0407,C0408

NECESSARY FITTINGS AND THRUST BLOCKS

INSTALL WATER LINE (D=150, PVC) INCLUDING

1.

SCALE : 1 / 200

SCALE: 1 : 200

S

S

S

S

E

E

E

F/H

F/H

SEWER MANHOLE

TREE

FIRE HYDRANT

GAS MARKER

TOP OF NATURAL

EL=117.954

TBM

,2

M

IN

CONCRETE DITCH.

REMOVE/REPLACE EXISTING STEEL GRATING COVERED

BASE COURSE AND SUBBASE COURSE SAME AS EXIST.

REMOVE/REPLACE EXISTING ASPHALT CONCRETE PAVEMENT,

REMOVE/REPLACE EXISTING CONCRETE SIDEWALK.

REMOVE EXISTING CONCRETE AROUND SUMP.

REMOVE EXISTING SUMPS.

SYSTEM AND CONCRETE PAD.

REMOVE EXISTING FUEL OIL TANK, FUEL LINES, LEAK DETECTION

INSTALL POST INDICATOR VALVE.

THRUST BLOCKS.

INSTALL WATER LINE INCLUDING NECESSARY FITTINGS AND

3.

2.

7.

6.

5.

4.

8.

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

29 JUL 15

D - 15 - 30

2 52

FROST DEPTH UNLESS OTHERWISE NOTED.

9. WATER AND SEWER LINE SHOULD HAVE A MINIMUM COVER OF

WITHOUT ANY ADDITIONAL COST.

INCLUDING FALSEWORK SUCH AS FORMWORKS AND SHORING

10. CONTRACTOR SHOULD PROVIDE ANY NECESSARY RESOURCES

LOCAL LAWS AND REGULATIONS.

GOVERNMENT LEASED PROPERTY IN ACCORDANCE WITH

11. DISPOSAL OF WASTE MATERIALS SHOULD BE OUTSIDE U.S

SPEC. AT THE LOCATION APPROVED/INDICATED BY C.O.R.

CONTRACTOR’S TEMPORARY FACILITIES ACCORDING TO O&MA

12. CONTRACTOR SHOULD PROVIDE AND MAINTAIN THE

SUBMISSION OF CONTRACT PROPOSAL.

AND DIMENSIONS AT THE PROJECT SITE ORIENTATION PRIOR TO

1. THE CONTRACTOR SHOULD VERIFY ALL EXISTING CONDITIONS

CONTRACTING OFFICER.

CONTRACTORS EXPENSE TO THE SATISFACTION OF THE

DAMAGED BY DISMANTLING, DEMOLISHING, OR REMOVING AT THE

RESTORATION TO THEIR ORIGINAL CONDITIONS OF THE ITEMS

3. THE CONTRACTOR SHOULD BE RESPONSIBLE FOR REPAIR/

BE COVERED WITH SOLID SODDING.

4. ALL UNPAVED AREAS WITHIN THE GRADING LIMIT LINE SHOULD

OPERATIONS.

ITEMS WHICH WILL INTERFERE WITH THE CONSTRUCTION

UNDER GROUND ROCK BASE, EXISTING UTILITY LINES, AND OTHER

CLEARED/REROUTED OF ALL NATURAL OBSTRUCTIONS, SUCH AS

5. THE SITE INDICATED ON THE DRAWING SHOULD BE GRADED AND

GENERAL NOTES :

COR PRIOR TO COMMENCING WORK ON THE PROJECT.

INDICATED BY THE COR AND SHOULD BE APPROVED BY THE

UNDETAILED PORTION OF THE JOB INCLUDING OTHER AREAS

2. THE CONTRACTOR SHOULD SUBMIT SHOP DRAWINGS FOR ANY

SCOPE OF WORK.

THE DETAILS WILL BE UTILIZED TO ACCOMPLISH THE CIVIL

AGENCY, KOREA REGION OFFICE FORM A PART OF THIS PROJECT.

2003, DEPARTMENT OF THE ARMY INSTALLATION MANAGEMENT

DETAIL DRAWINGS, FOR O & MA PROJECT, KOREA, OCTOBER 1,

8. THE CIVIL STANDARD DRAWINGS SHOWN IN THE "STANDARD

AND OTHER UTILITY MARKERS IN THE PROJECT LIMIT.

7. CONTRACTOR SHALL RESTORE/RE-ESTABLISH SURVEY MOUMENTS

PERIOD IF REQUIRED.

AND DETOUR ROAD FOR VEHICLES DURING CONSTRUCTION

6. CONTRACTOR SHOULD PROVIDE TEMPORARY ACCESS ROAD

THE PUBLIC AND/OR MILITARY TRAFFIC AND OPERATIONS.

NECESSARY PRECAUTIONS FOR THE PROTECTION AND SAFETY OF

AND OTHER PROTECTIVE FACILITIES AND SHALL TAKE ALL

NECESSARY SIGNS, LIGHTS, FLARES, BARRICADES, MARKERS, CONES

14. CONTRACTOR SHALL PROVIDE, INSTALL AND MAINTAIN ALL

APPROVAL PRIOR TO COMMENCING THE WORK.

TO THE DESIGN AND TECHNICAL REVIEW BRANCH FOR

13. THE CONTRACTOR SHOULD PREPARE/SUBMIT MATERIAL REVIEWS

ON THE DRAWING, CONTRACTOR SHALL VERIFY THE LOCATIONS OF UTILITY LINES.

3. UTILITY LINES SUCH AS WATER LINE, SEWER LINE AND FUEL OIL LINE THAT ARE NOT SHOWN

RETURNED TO DPW AFTER CLEANING THE INTERIOR AND EXTERIOR.

2. FUEL OIL TANK AND LEAK DETECTION SYSTEM ARE SALVAGEABLE MATERIALS AND SHALL BE

OF FUEL LINE AND SUMP PUMPS TO THE COR AND ENVIRONMENTAL DIVISION.

1. CONTRACTOR SHOULD REPORT ANY CONTAMINATED SOIL DISCOVERED DURING EXCAVATIONS

NOTES:

RETURNED TO DPW.

15. SALVAGEABLE MATERIAL WITHIN PROJECT LIMIT SHALL BE

MILLIMETERS.

16. UNLESS OTHERWISE NOTED ALL THE DIMENSIONS ARE IN

GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

AREAS AS DIRECTED BY THE CONTRACTING OFFICER.

EXISTING AREAS CAUSED BY THIS PROJECT AND TO MATCH CONDITION TO ADJACENT

THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO

CONTRACTING OFFICER FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE

FIELD CONDITIONS, SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE

SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACTLY

APPROVAL BY THE C.O. OR HIS COR.

CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR

FACTOR).

INSULATION HEAT RESISTANCE VALUE (ROOF - R=38 FACTOR AND WALL - R=15

APPROVED BY THE C.O. OR HIS COR. BEFORE FABRICATION AND INSTALLATION.

DRAWINGS FOR ALL DOOR AND WINDOW DETAILS AND DRAWING SHALL BE

MANUFACTURER’S INSTRUCTIONS. THE CONTRACTOR SHALL PREPARE SHOP

ALL DOORS AND WINDOWS SHALL BE FABRICATED I.A.W. SPECIFICATIONS AND

ROUGH-IN WORK IS ACCOMPLISHED PRIOR TO FINISHING WORK.

FIRE ALARM SYSTEM COORDINATION OF THIS WORK MUST BE DONE TO INSURE

INSTALLATION AND REPLACEMENT OF MECHANICAL, ELECTRICAL, TELEPHONE AND

CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING TO MAKE WAY FOR THE

CAULKING MATERIALS RATED FOR THE FIRE WALL.

ALL PENETRATIONS THROUGH FIRE RATED WALLS MUST BE SEALED WITH APPROVED

UP UP

TO THE PROJECT CONTRACT.

TO ACCOMPLISH THE ARCHITECTURAL SCOPE OF WORK AT NO ADDITIONAL COST

1 OCTOBER 2003" FORM AS A PART OF THIS PROJECT. THE DETAILS WILL BE UTILIZED

CENTER, DEPUTY COMMANDER FOR BASE OPERATIONS AND ENGINEERING,

DRAWINGS FOR O&MA PROJECTS, KOREA, HEADQUARTERS, 19TH THEATER SUPPORT

THE ARCHITECTURAL STANDARD DRAWINGS SHOWN IN THE "STANDARD DETAIL

2ND FLOOR PLAN2ND FLOOR PLAN

DN DN

CORRIDOR

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AE-01

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

AE 01

SCALE : 1 / 100

1ND FLOOR PLAN

N

N

REMOVAL / EXISTING FLOOR PLAN, BLDG #575

REMOVAL WORK

REMOVE AL. WINDOW WITH WOOD TRIM.

REMOVE STEEL DOOR WITH FRAME

3 REMOVE WOOD DOOR WITH FRAME

LAV. LAV. LAV. LAV. LAV.

LAV. LAV. LAV. LAV.

REMOVE WALL TILE, BASE MORTAR WITH METAL LATH.

LAV.

REMOVE FLOOR TILE, BASE MORTAR WITH DECK PLATE.

REMOVE CEILING GYPSUM BOARD WITH SUSPENSION SYSTEM.8

REMOVE GYPSUM WALL BOARD WITH METAL&WOOD FRAME.9

REMOVE EXTERIOR INSULATION AND FINISH SYSTEM.10

REMOVE RAINGUTTER AND DOWNSPOUT.11CORRIDOR

BED RM.

BED RM.

WIC

HALL

AREA

SERV.

BATH

WIC

BATH

WIC

HALL

BED RM.

BED RM.

WIC

AREA

SERV.

BATH

WIC

HALL

BED RM.

BED RM.

BED RM.

WIC

WIC

AREA

SERV.

AREA

SERV.

HALL

CORRIDOR

BATH

WIC

BED RM.

BED RM.

BED RM.

HALL

WIC

BATH

AREA

SERV.

MECH. RM.

BED RM.

WIC

AREA

SERV.

HALL

BED RM.

WIC

BATH

WIC

BATH

HALL

BED RM.

BED RM.

WIC

AREA

SERV.

BATH

HALL

AREA

SERV.

WIC

JAN.

BED RM.

LAUNDRY RM.

HALL

CORRIDOR

WIC

AREA

SERV.

HALL

BATH

WIC

BED RM.

BED RM.

BED RM.

WIC

BATH

HALL

BED RM.

WIC

AREA

SERV.

REMOVE KITCHEN BASE, KITCHEN CABINET AND LAVATORY CABINET.

REMOVE FLOOR DECO TILE WITH FLYWOOD UNDERLAYMENT.

REMAIN EXISTING CMU WALL OR METAL WALL

REMAIN EXISTING CMU WALL OR METAL WALL

13 REMOVE 1F CONCRETE FLOOR FOR MECHANICAL WORK.

REMOVE STAIR HANDRAIL AND 2F CORRIDOR GUARD RAIL.

L E G E N DL E G E N D

EXISTING CMU OR METAL WALL

PARTITIONS WITH FINISH

REPLACE EXIST DRYWALL

REPLACE EXISTING WINDOW

BLOCK-UP WITH EXISTING CMU OR METAL

REMOVE EXISTING WINDOW AND

REPLACE EXISTING CONCRETE FLOOR

REPLACE EXISTING CONCRETE FLOOR

EXISTING SPLASH BLOCK

EXISTING FIRE EXTINGUISHER

NOTES

* NETWORKED ELECTRONIC LOCK SYSTEM (SALTO LOCK SYSTEM)

2. THE CONTRACTOR SHALL PREVENT DEMAGE TO SLATO LOCK SYSTEM INSTALLED ON DOOR SIMBOL "D1, D2, D7" DURING CONSTRUCTION.

1. THE CONTRACTOR SHALL VERIFY WORKING CONDITION OF EXISTING NETWORKED ELECTRONIC LOCK SYSTEM (SLATO LOCK SYSTEM) WITH THE GOVERMENT.

4. THE CONTRACTOR SHALL RETURN DISASSEMBLED SALTO LOCK SYSTEM TO THE GOVERMENT.

3. THE CONTRACTOR SHALL DISASSEMBLE SLATO LOCK SYSTEM INSTALLED ON BED ROOM DOOR AND PACK EACH UNIT IN BOXES WITH WHOLE COMPONENT.

AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION

29 JUL 15

3 52

REMOVAL WORK AND LEGEND

NOTE, GENERAL NOTES,

REMOVAL / EXISTING FLOOR PLAN, BLDG #575,

BED RM.

WIC

BATH

DN DN

REF

LIVING RM.

KITCHEN

D1

D4

D5

PIPE SHAFT

BED RM.

BATH

REF

LIVING RM.

KITCHEN

D1

D4

D5

BED RM.

WIC

BATH

REF

LIVING RM.

KITCHEN

D1

D4

D5

BED RM.

WIC

BATH

REF

LIVING RM.

KITCHEN

D1

D4

D5

BED RM.

WIC

BATH

REF

LIVING RM.

KITCHEN

D1

D4

D5

WIC

FLOOR: 1

BUILDING: 575

BUILDING: 575

FLOOR: 2

UP UP

HALL

JAN.

MECH. RM.

CORRIDOR

STORAGE

DRYER

DRYER

MACHINE

WASHING

MACHINE

WASHING

SINK

LAUNDRY

LAUNDRY RM.

COMM. RM.

D7

D3

D8

BED RM.

WIC

BATH

REF

LIVING RM.

KITCHEN

D1

D4

D5

BED RM.

WIC

BATH

REF

LIVING RM.

KITCHEN

D1

D4

D5

BED RM.

WIC

BATH

REF

LIVING RM.

KITCHEN

D1

D4

D5

BED RM.

WIC

BATH

REF

LIVING RM.

KITCHEN

D1

D4

D5

2861mm

9’-5" m m m m

36461mm

119’-7"

2861mm

9’-5" m m m m

3646mm

12’-0" m m m m

3646mm

12’-0"

3646mm

12’-0"

3646mm

12’-0"

3646mm

12’-0"

3646mm

12’-0"

3646mm

12’-0"

3646mm

12’-0"

3646mm

12’-0"

3646mm

12’-0" m m m m m m m m

" W2 W2 W2 W2

W2 W2 W2 W2

W1 W1 W1 W1 W1 W1 W1 W1

101d

101 101a

101c

101b

102a 102

102c

102b

102d

106a 106

106c

106b

106d

103a

104a

105a105

105d

105b

105c

D2

201a201

201d

201b

201c

202a 202

202c

202b

202d

205a 205

205c

205b

205d

203a 203

203c

203b

203d

204 204a

204d

204b

204c

36824mm

120’-10" m m m m m m m m

W1

CORRIDOR

W1W1W1 W1 W1 W1 W1 W1 W1W1

CEILING ACCESS DOOR.

REPLACE ALL EXISTING CEILING SYSTEM WITH NEW INCLUDING

ACCESSORIES.

WINDOW INCLUDING OAK WOOD TRIM, VENETIAN BLIND AND NECESSARY

REPLACE DETERIORATED EXISTING WINDOW WITH NEW BLAST RESISTANT

LAVATORY CABINET, MIRROR, ROBE HOOK AND NECESSARY ACCESSORIES.

REPLACE EXISTING BATHROOM ACCESSORIES WITH NEW INCLUDING

SINK TOP) & WALL CABINETS WITH NEW.

REPLACE EXISTING KITCHEN BASE (BOWL, SOLID SURFACE ARTIFICIAL

WITH NEW.

REPLACE DETERIORATED EXISTING INTERIOR AND EXTERIOR SIGNAGE

INSTALL INTERIOR AND EXTERIOR SIGNAGE.

COVE BASE AND NECESSARY ACCESSORIES.

VINYL COMPOSITION TILE INCLUDING PLYWOOD, WOOD

REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW

NOTE

- CERTIFICATION OF GREEN TECHNOLOGY

- TEST REPORT OF ASTM D6083 (WATERPROOFING)

- TEST REPORT OF SOLAR REFLECTIVITY INDEX(SRI)

MIN 100 OF LEED REQUIREMENTS

- TEST REPORT OF UL 790 CLASS A

- ENERGY STAR QUALIFIED

- CRRC(COOL ROOF COUNCIL RATING) RATED

REFERENCES SECTION 07 14 01

3. ACRYLIC FLUID-APPLIED WATERPROOFING

2. THIS PROJECT DOES NOT INCLUDE THE FURNITURE.

1. BLDG #575: 2 STORY BUILDING.

UFC 4-010-01

ASTM F 2248

ASTM E 1300

ASTM F 1642

4. CODE REFERENCES

FOR BUILDINGS.

DoD MINIMUM ANTITERRORISM STANDARDS

RESISTANT GLAZING FABRICATED WITH LAMINATED GLASS.

3-SECOND DURATION DESIGN LOADING FOR BLAST

STANDARD PRACTICE FOR SPECIFYING AN EQUIVALENT

OF GLASS IN BUILDINGS.

STANDARD PRACTICE FOR DETERMINING LOAD RESISTANCE

SYSTEMS SUBJECT TO AIRBLAST LOADINGS.

STANDARD TEST METHOD FOR GLAZING AND GLAZING

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

4 52

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AE-02

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

SCOPE OF WORK AND LEGEND

NOTE,

NEW FLOOR PLAN BLDG #575,

AE 02

SCALE : 1 / 100

NEW FLOOR, BLDG #575

1st FLOOR PLAN

2nd FLOOR PLAN

FD

FD

20 REMOVE AND REINSTALL EXISTING STEEL DOOR (D1, D2, D7).

FOR MECHANICAL WORK. (WORKING AREA ONLY, SEE MECH. DWG.)

REPLACE EXISTING 1F FLOOR AND MECHANICAL ROOM CONCRETE SLAB.

SCOPE OF WORKSCOPE OF WORK

ACCESSORIES.

NON-SLIP FLOOR TILES WITH NEW INCLUDING NECESSARY

REPLACE DETERIORATED EXISTING CERAMIC WALL TILES AND

METAL FRAME AND NECESSARY ACCESSORIES.

REPLACE DETERIORATED EXISTING DOOR WITH NEW INCLUDING

INCLUDING SPLASH BLOCKS AND NECESSARY ACCESSORIES.

REPLACE EXISTING RAIN GUTTER AND DOWNSPOUTS WITH NEW

WITH NEW INCLUDING METAL LATH. R-VALUE=15.

REPLACE EXISTING EIFS (EXTERIOR INSULATION FINISH SYSTEM)

A. CONSTRUCTION / ALTERATION : L - WORK

INSTALL 10EA STEEL CAGES IN STORAGE WITH NEW.

REMOVE & REINSTALL EXISTING FIRE EXTINGUISHER AND CABINETS.

FLASHING AND NECESSARY ACCESSORIES.

FLOOR CORRIDOR’S CEILING WITH NEW INCLUDING METAL

REPLACE DETERIORATED EXISTING METAL LINER OF 1ST & 2ND

INCLUDING METAL FRAME, INSULATION AND NECESSARY ACCESSORIES.

REPLACE DETERIORATED EXISTING INTERIOR WALL WITH NEW

INCLUDING NECESSARY ACCESSORIES AT WHOLE ROOF AREA.

INSTALL NEW ACRYLIC FLUID-APPLIED WATERPROOFING SYSTEM

AND NECESSARY ACCESSORIES. (#103, COMM ROOM)

BLOCK-UP EXISTING WINDOW WITH GWB, METAL FRAME, INSULATION

CORRIDOR GUARD RAIL WITH NEW INCLUDING NECESSARY ACCESSORIES.

REPLACE DETERIORATED EXISTING STAIR HANDRAIL AND 2ND FLOOR

L E G E N DL E G E N D

EXISTING CMU OR METAL WALL

REPLACE EXISTING WINDOW

50mm THK STUD WALL WITH GWB

100mm THK STUD WALL WITH GWB

150mm THK STUD WALL WITH GWB

90mm THK STUD WALL WITH GCWT

WOOD DOOR WITH FRAME

STEEL DOOR WITH FRAME

LOCATION OF STRUCTURAL STEEL

WITH FIRE EXTINGUISHER

EXISTING FIRE EXTINGUISHER CABINET

EXISTING KITCHEN WINDOW

SEE ENLARGED PLAN

AE 06

SEE ENLARGED PLAN

AE 07

BLAST RESISTANT WINDOW

76mm

3"

TB WC SD

TTD

D6

FD

LAV

SHELF

TBWCSD

TTD

D6

FD

LAV

SHELF

TBWCSD

TTD

D6

FD

LAV

SHELF

TBWCSD

TTD

D6

FD

LAV

SHELF

TB WC SD

TTD

D6

FD

LAV

SHELF

TBWCSD

TTD

D6

FD

LAV

SHELF

TB WC SD

TTD

D6

FD

LAV

SHELF

TBWCSD

TTD

D6

FD

LAV

SHELF

TB WC SD

TTD

D6

FD

LAV

SHELF

SD SD SD SD SD

SDSDSDSD

29 JUL 15

HANDRAIL AS PER SPEC. (MPI)

PAINT ON ENTIRE INTERIOR & EXTERIOR WALLS, METAL DOORS, EXTERIOR

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

5 52

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AE-03

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

AE 03

SCALE : 1 / 100

ELEVATION, BLDG #575

AE 03

E-2

BLDG. S-575

EXIST.MAIN

MECH.RM.

SLOPE

GL.

EXIST CONC.

W-1 W-1 W-1W-1W-1 W-1W-1 W-1 W-1

W-1 W-1 W-1W-1W-1 W-1W-1 W-1 W-1

MTL. ROOF

EXIST PROTECT RIBBED

WATERPROOFING SYSTEM

INSTALL ACRYLIC FLUID-APPLIED

BLDG. S-575

EXIST.MAIN

AE 03

E-3

AE 03

E-4

UP UP

N

HALL

JAN.

MECH. RM.

CORRIDOR

STORAGE

DRYER

DRYER

MACHINE

WASHING

MACHINE

WASHING

SINK

LAUNDRY

LAUNDRY RM.

COMM. RM.

D7

D3

D8

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

KEY PLAN, BLDG #575

E-1

E-2

E-3

E-4

AE04

AE04

AE04

AE04

GWB - GYPSUM WALL BOARD

CMT - CERAMIC MOSAIC TILE

GCWT - GLAZED CERAMIC WALL TILE

VCT - VINYL COMPOSITION TILE

RT - RUBBER TILE

HDR - HARDENER

F.F. - FACTORY FINISH

WIC. - WALK-IN CLOSET

MTL. - METAL

MTL. - METAL

FIN. - FINISH

CLR. - COLOR

HGT. - HEIGHT

CONC. - CONCRETE

WDW. - WINDOW

CMU. - CONCRETE MASONRY UNIT

EIFS. -

FINISH SYSTEM

EXTERIOR INSULATION

N.F.S.M. -

MATERIAL

NON FROST SUSCEPTIBLE

EXP. - EXPANSION

INSULATIONINSUL. -

DWG. - DRAWING

EXISTINGEXIST. -

INT. -

GA. -

INTERIOR

GL. - GROUND

GAGE

NO. - NUMBER

N.I.C. - NOT IN CONTRACT

DETAILDET. -

CONT. - CONTINUOUS

MTL. ROOF

EXIST PROTECT RIBBED

GL.

W/ NEW

REPLACE HANDRAIL

W/ NEW

REPLACE HANDRAIL

R E H S I U G N I T X E

E R I F

R E H S I U G N I T X E

E R I F

INSECT SCREEN (TYPICAL)

REPLACE EXISTING WINDOW

WATERPROOFING SYSTEM

INSTALL ACRYLIC FLUID-APPLIED

W/ NEW

REPLACE METAL LINER

AE 03

E-1

HANDRAIL

REPAINT EXISTING

EXIST CONC.

STAIR.

EXIST CONCHANDRAIL

REPAINT EXISTING

W-2

W-2D-1

D-1

D-1

D-1 W-2

W-2

D-2

W-2

D-1

D-1W-2

W-2 D-1

D-1W-2 D-1

D-1 W-2

W/ NEW.

REPLACE GUARD RAIL

ABBREVIATION

29 JUL 15

KEY PLAN, BLDG #575

ABBREVIATION,

ELEVATION, BLDG #575,

1ND FLOOR PLAN 2ND FLOOR PLAN2ND FLOOR PLAN

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

6 52 AE-04

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

DN DN

N

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

PIPE SHAFT

BED RM.

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

WIC

UP UP

N

HALL

JAN.

MECH. RM.

CORRIDOR

STORAGE

DRYER

DRYER

MACHINE

WASHING

MACHINE

WASHING

SINK

LAUNDRY

LAUNDRY RM.

COMM. RM.

D7

D3

D8

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

KEY PLAN, BLDG #575

AE04

AE04

AE04

AE04

REPLACE EXIST. FLOOR (PLYWOOD). W/NEW

1600mm

5’-3"

2183mm

7’-2"

2108mm

6’-11"

4626mm

15’-2"

9293mm

30’-6" m m m m m m m m m m m m m m m m m m m m m m m m m m

GL

GL

1st FLOOR

2nd FLOOR

X X X X X X X X X

FL.

BATH RM.

BATH RM.

WIC

WIC

BED RM.

BED RM.

W-1

W-1

CORRI.

CORRI.

EXIST ROOF

EXIST WALL

EXIST WALL

100 MM WD.BASE

COVE.BASE W/ NEW

REPLACE EXIST.

EXIS

T S

TL.R

AFT

ER EXIST STL.RAFTER

FD

100 MM WD.BASE

COVE.BASE W/ NEW

REPLACE EXIST.

1- MEMBRANE

METAL LATH /

GCWT. W/ MORTAR BED/

REPLACE

1- MEMBRANE

METAL LATH /

GCWT. W/ MORTAR BED/

REPLACE

CMT W/ NEW

REPLACE EXIST

WATER BARRIER

150MM THK. CAPILLARY

(RUBBER TYPE)

1 - VAPOR BARRIER

2nd FLOOR

1st FLOOR

100 MM WD.BASE

COVE.BASE W/ NEW

REPLACE EXIST.

E X

IS

T

E X

T

EXIST. FLOOR.

W.W.F. (TYP.)

CONC. FL.W/ 150X 150 / 2.0WX2.0W

50MM DEPRESSED 100MM THK.

AIR INTAKE SEE MECH DWG.

X X X X X

EXIST FLOOR.

REMAIN

MORTAR FIN.

FLOOR SURFACES W/ CONC

CHIPPING/ REMOVE EXIST.

APPROX. 50 DEPTH

EXIST COLUMN

EXIST FDN.

REMAIN

REPLACE EXIST DOWNSPOUT

WATERPROOFING SYSTEM

INSTALL ACRYLIC FLUID-APPLIED

(ONLY AT GCWT)

@ 300 MM OC.

50 MM MTL. STUD

@ 300MM O.C.

METAL STUD

100MM

GWB.

NEW 15MM THK.

GWB.LINING W/

REPLACE EXIST

@ 450MM O.C.

METAL STUD

150MM

THK.GWB

NEW 15MM

LINING W/

REPLACE EXST

(ONLY AT GCWT)

@ 300 MM OC.

50 MM MTL. STUD

GWB.

NEW 15MM THK.

GWB.LINING W/

REPLACE EXIST

@ 300MM O.C.

METAL STUD

100MM

450MM OC.

MTL.STUD @

STUD W/ 100

REPLACE EXIST

W/ NEW

REPLACE EXISTING VCT

@ 450MM O.C.

METAL STUD

150MM

THK.GWB

NEW 15MM

LINING W/

REPLACE EXST

@ 400MM O.C.

6MM DIA EXP.BOLT

BASE CHANNEL W/

150MM MTL.

@ 400MM O.C.

D6 EXP.BOLT

BASE CHANNEL W/

150MM MTL.

@ 400MM O.C.

D6 EXP.BOLT

BASE CHANNEL W/

50MM WIDE METAL

C L G .H

G T

C L G .H

G T

EXIST FDN.

E X

T

C L G .H

G T

E X

T

C L G .H

G T

SEE MECH DWG.

AIR INTAKE

FD

REPLACE EIFS

TYPE

12.5 THK.WATER RESISTANT

GWB.CLG.W/ NEW GWB.

REPLACE EXIST

TYPE

12.5 THK.WATER RESISTANT

GWB.CLG.W/ NEW GWB.

REPLACE EXIST

GWB. / FRAME

FRAME W/ NEW 12.5MM THK.

W/ NEW / MTL. CLG. HANGER

GWB.CLG. BOARD

REPLACE EXIST

GWB CLG / MTL.FRAME

W/ NEW 12.5 MM THK.

REPLACE EXIST CLG.

REPLACE EXISTING VCT W/ NEW

AE 04

SCALE : 1 / 40

CROSS SECTION, BLDG #575

GL

FL.

2nd FLOOR

1st FLOOR

BED RM.

BED RM.

EXIST WALL

WOOD BASE

25X100

EXIST FDN.

m m m m m m

C L G .H

G T m m m m

EXIST ROOF

MTL.CASING TRIM

MTL.CASING TRIM

25 X 100 WD. BASE

MORTAR FIN.

FLOOR SURFACES W/ CONC

CHIPPING/ REMOVE EXIST.

APPROX. 50 DEPTH

& TERMINATIONS.

TAPE ALL SEAMS, PENETRATIONS

1 - LAYER VAPOR BARRIER

R = 38

NEW GREEN ENVIRONMENTAL

W/ REPLACE EXIST INSUL.

@ 450 MM OC.

50 MM MTL. STUD

15 MM GWB.LINING

THK.GWB. / FRAME

FRAME W/ NEW 15MM

GWB./ MTL. CLG. HANGER

REPLACE EXIST

THK.GWB. / FRAME

FRAME W/ NEW 15MM

GWB./ MTL. CLG. HANGER

REPLACE EXIST

@ 450 MM OC.

50 MM MTL. STUD

15 MM GWB.LINING

VCT FIN.

@ 400MM O.C.

D6 EXP.BOLT

BASE CHANNEL W/

50MM MTL.

@ 400MM O.C.

6MM DIA EXP.BOLT

BASE CHANNEL W/

50MM WIDE METAL

C L G .H

G T . E

X

V

R

IO

U S

REPLACE EXIST VCT FIN.

AE 04

SCALE : 1 / 40

TYPICAL WALL SECTIONS

AND KEY PLAN, BLDG #575

TYPICAL WALL SECTIONS,

CROSS SECTION, BLDG #575,

29 JUL 15

WATERPROOFING SYSTEM

INSTALL ACRYLIC FLUID-APPLIED

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

7 52 AE-05

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

1ND FLOOR PLAN 2ND FLOOR PLAN2ND FLOOR PLAN

DN DN

N

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

PIPE SHAFT

BED RM.

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

WIC

UP UP

N

HALL

JAN.

MECH. RM.

CORRIDOR

STORAGE

DRYER

DRYER

MACHINE

WASHING

MACHINE

WASHING

SINK

LAUNDRY

LAUNDRY RM.

COMM. RM.

D7

D3

D8

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WCSD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

BED RM.

WIC

BATH

LAV

WC SD

TB

REF

SD

SHELF

TTD

LIVING RM.

KITCHEN

D1

D4

D5

D6

KEY PLAN, BLDG #575

AE 05

SCALE : 1 / 25

WALL SECTION DETAIL

m m m m m m m m m m

350mm

1’-2"

300mm

1’-0" m m m m

300mm

1’-0"

350mm

1’-2" m m m m m m m m m m m m

EXST CMU OR

METAL WALL

15MM THK

GWB LINING

300X300X7

GCWT. W/ MORATAR

BED, MTL. LATH / 1-PLY

MEMBRANE

LAUNDRY RM.

12.5MM THK.GWB

WATER RESISTANT

W/ MTL. FRAME

50MM DEPRESSED

100MM THK. CONC.

FL.W/ 150X150

/#8X#8 W.W.F. (TYP.)

REPLACE EXIST BASE

SHT. W/ NEW VAPOR

BARRIER SHEET

(RUBBER TYPE)

150MM THK.

CAPILLARY

WATER BARRIER

VCT FIN.

VCT FIN.

15MM THK GWB LINING

EXST CMU OR

METAL WALL

12.5MM THK GWB.

CLG. W/ MTL. FRAME

12.5MM THK GWB.

CLG. W/ MTL. FRAME

LIVING RM.

50MM MTL

STUD @ 450MM O.C.

W/ 50MM MINERAL FIBER

BLANKET INSULATION

50MM MTL

STUD @ 450MM O.C.

W/ 50MM MINERAL FIBER

BLANKET INSULATION

50MM MTL

STUD @ 450MM O.C.

W/ 50MM MINERAL FIBER

BLANKET INSULATION

300 X 300 X 6

QUARRY TILE

(NONSLIP TYPE)

KITCHEN

BATH

STORAGE

VCT FIN.

50MM MTL

STUD @ 450MM O.C.

15MM THK

GWB LINING

KITCHEN

VCT FIN.

300X300X7

GCWT.

15MM THK

GWB LINING

WATER RESISTANT

OR FIRE RESISTANT

50MM MTL

STUD @ 450MM O.C.

W/ 50MM MINERAL FIBER

BLANKET INSULATION

12.5MM THK.GWB

W/ MTL. FRAME

VCT FIN.

300X300X7

GCWT.

15MM THK

GWB LINING

WATER RESISTANT

OR FIRE RESISTANT

50MM MTL

STUD @ 450MM O.C.

W/ 50MM MINERAL FIBER

BLANKET INSULATION

12.5MM THK.GWB

W/ MTL. FRAME

12.5MM THK.GWB

WATER RESISTANT

W/ MTL. FRAME

300X300X7

GCWT. W/ MORATAR

BED, MTL. LATH / 1-PLY

MEMBRANE

15MM THK

GWB LINING

1-PLY MEMBRANE

50MM MTL

STUD @ 450MM O.C.

W/ 50MM MINERAL FIBER

BLANKET INSULATION

300 X 300 X 6

QUARRY TILE

(NONSLIP TYPE)

LIVING RM. LIVING RM.

BED RM. BED RM.

15MM THK

GWB LINING

VCT FIN.VCT FIN.

VCT FIN.

LIVING RM.

LIVING RM.

15MM THK GWB LINING

15MM THK

GWB LINING

VCT FIN.VCT FIN.

VCT FIN.

LIVING RM.

LIVING RM.

15MM THK GWB LINING

WIC

WIC

150MM MTL.

BASE CHANNEL W/ D6

EXP.BOLT @ 450MM O.C.

150MM MTL.

BASE CHANNEL W/ D6

EXP.BOLT @ 450MM

O.C.

19MM THK.

PLYWD. SHELF

D30 STAINLESS

STEEL ROD AND

FLANGE

25MM THK.

HARDWOOD BRACKET

25MM THK.

HARDWOOD BRACKET

D30 STAINLESS

STEEL ROD AND

FLANGE

19MM THK.

PLYWD. SHELF

EXIST FL.

1stFL.

SLOPE

25X100

WOOD BASE

12.5MM THK GWB.

CLG. W/ MTL. FRAME

2nd FL.

EXP.JOINT

25X100

WOOD BASE

12.5MM THK GWB.

CLG. W/ MTL. FRAME

MTL. CASING TRIM

W/SEALANT

1stFL.

2nd FL.

EXP.JOINT

BED ROOM

C L G

H G

T

C L G

H G

T

25X100

WOOD BASE

1stFL.

2nd FL.

12.5MM THK GWB.

CLG. W/ MTL. FRAME

150MM MTL.

STUD @450MM O.C.

150MM MTL.

BASE CHANNEL W/ D6

EXP.BOLT @ 300MM

O.C.

EXIST FL.

150MM MTL.

BASE CHANNEL W/ D6

EXP.BOLT @ 300MM O.C.

150MM MTL.

STUD @450MM O.C.

BED ROOM

12.5MM THK GWB.

CLG. W/ MTL. FRAME

25X100

WOOD BASE

C L G

H G

T

C L G

H G

T

25X100

WOOD BASE

1stFL.

2nd FL.

12.5MM THK GWB.

CLG. W/ MTL. FRAME

150MM MTL.

STUD @450MM O.C.

EXIST FL.

150MM MTL.

STUD @450MM O.C.

25X100

WOOD BASE

12.5MM THK GWB.

CLG. W/ MTL. FRAME

S-1

AE05

S-1

AE05

S-1

AE05

S-2

AE05

S-2

AE05

S-3

AE05

S-3

AE05

S-3

AE05

S-2

AE05

S-4

AE05

S-4

AE05

S-4

AE05

AND KEY PLAN, BLDG #575

WALL SECTION DETAIL,

29 JUL 15

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

8 52 AE-06

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

BED RM.

202a 202

LIVING RM.

D4

D5

202c

WIC

D6

202b

BATH

SD

SHELF

FD

WC

TTD

REF

D1

W1 W1

W2

202d

KITCHEN

3405mm

11’-2" m m

3405mm

11’-2"

4810mm

15’-9"

1970mm

6’-6" m m

1825mm

6’-0"

2000mm

6’-7" m m m m m m

W

W

W

W

W

W

W150 W150 W150

W

W

W

W

W

W

W

W

W

W

W

W

W50

W

W100

W100

W100

W

W

WITH NEW BLAST RESISTANT WINDOW

REPLACE DETERIORATED EXISTING WINDOW

15mm THK. GWB

100mm METAL STUD @ 450mm O.C.

15mm THK. GWB

T Y P E

’G

W B

15mm THK. GWB

50mm METAL STUD @ 300mm O.C.

15mm THK. GWB (FIRE RESISTANT TYPE)

GCWT

F

IR

S

IS

T A

N T

T

Y P E

W A T

S

IS

T A

N T

T

Y P E m m m m

15mm THK. GWB

150mm METAL STUD @ 450mm O.C.

15mm THK. GWB

15mm THK. GWB

150mm METAL STUD @ 450MM O.C.

15mm THK. GWB

150mm METAL STUD @ 450MM O.C.

15mm THK. GWB

150mm METAL STUD @ 450mm O.C.

15mm THK. GWB

AE 06

SCALE : 1 / 25

ENLARGED UNIT FLOOR PLAN

W50 W50 W50W50 W50 W50 m m m m

685mm

2’-3"

EXISTING CMU WALL OR METAL WALL

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm METAL STUD @ 450MM O.C.

(FLOOR TO FLOOR(1F) OR ROOF(2F))

15mm THK. GWB

EXISTING CMU WALL OR METAL WALL

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm METAL STUD @ 450MM O.C.

(FLOOR TO FLOOR(1F) OR ROOF(2F))

15mm THK. GWB

EXISTING CMU WALL OR METAL WALL

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm METAL STUD @ 450mm O.C.

(FLOOR TO FLOOR(1F) OR ROOF(2F),

15mm THK. GWB

EXISTING CMU WALL OR METAL WALL

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm METAL STUD @ 300mm O.C.

(FLOOR TO FLOOR(1F) OR ROOF(2F), USE NORMAL TYPE ABOVE CEILING)

15mm THK. GWB (FIRE RESISTANT TYPE)

GCWT

REMOVE / RECOVER EXISTING CMU OR METAL WALL FOR MECHANICAL WORK

L E G E N DL E G E N D

EXISTING CMU OR METAL WALL

REPLACE EXISTING WINDOW

50mm THK STUD WALL WITH GWB

100mm THK STUD WALL WITH GWB

150mm THK STUD WALL WITH GWB

90mm THK STUD WALL WITH GCWT

WOOD DOOR WITH FRAME

STEEL DOOR WITH FRAME

LOCATION OF STRUCTURAL STEEL

EXISTING KITCHEN WINDOW

BLAST RESISTANT WINDOWLAV

AE 08

SEE DETAIL

EXISTING CMU WALL OR METAL WALL

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm METAL STUD @ 300mm O.C.

15mm THK. GWB (WATER RESISTANT TYPE)

GCWT WITH BOND COAT

15mm THK. GWB

50mm METAL STUD @ 300mm O.C.

15mm THK. GWB (WATER RESISTANT TYPE)

GCWT WITH BOND COAT

EXISTING CMU WALL OR METAL WALL

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm METAL STUD @ 300mm O.C.

(FLOOR TO FLOOR(1F) OR ROOF(2F), USE NORMAL TYPE ABOVE CEILING)

15mm THK. GWB (WATER RESISTANT TYPE)

GCWT WITH BOND COAT

W A T

S

IS

T A

N T

T

Y P E m m

N O

R M

A L

T

Y P E

SD

GCWT WITH BOND COAT

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

50mm METAL STUD @ 300mm O.C.

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

GCWT WITH BOND COAT ON LIQUID WATERPROOFING CEMENT

EXISTING CMU WALL OR METAL WALL

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm METAL STUD @ 300mm O.C.

(MEMBRANE SHEET-FLOOR TO FLOOR(1F) OR ROOF(2F))

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

GCWT WITH BOND COAT ON LIQUID WATERPROOFING CEMENT

GCWT WITH BOND COAT ON LIQUID WATERPROOFING CEMENT

(MEMBRANE SHEET-FLOOR TO FLOOR(1F) OR ROOF(2F))

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

(FLOOR TO FLOOR(1F) OR ROOF(2F))

100mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

100mm METAL STUD @ 300mm O.C.

WATER RESISTANT TYPE, FLOOR TO FLOOR(1F) OR ROOF(2F))

15mm THK. GWB, (USE NORMAL TYPE ABOVE CEILING, GCWT WITH BOND COAT

GCWT WITH BOND COAT ON LIQUID WATERPROOFING CEMENT

(MEMBRANE SHEET-FLOOR TO FLOOR(1F) OR ROOF(2F))

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

(FLOOR TO FLOOR(1F) OR ROOF(2F))

100mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

100mm METAL STUD @ 300mm O.C.

15mm THK. GWB

EXISTING CMU WALL OR METAL WALL

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm MINERAL FIBER BLANKET INSULATION

(FLOOR TO FLOOR(1F) OR ROOF(2F))

50mm METAL STUD @ 300mm O.C.

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

GCWT WITH BOND COAT ON LIQUID WATERPROOFING CEMENT

AE09

A

B

AND LEGEND

ENLARGED UNIT FLOOR PLAN,

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

9 52 AE-07

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

AE 07

SCALE : 1 / 25

m m

5586mm

18’-4" m m

1215mm

4’-0" m m m m m m

3415mm

11’-2"

3405mm

11’-2"

COMM. RM.

LAUNDRY RM.

2085mm

6’-10"

1330mm

4’-4" m m

130mm

5" m m

1775mm

5’-10"

104a

JAN.

D8

D2D7

103a

STORAGE

WITH NEW BLAST RESISTANT WINDOW

REPLACE DETERIORATED EXISTING WINDOW

W1

WITH EXISTING CMU OR METAL

BLOCK-UP EXISTING WINDOW OPENING

SEE DETAIL DWG

STEEL CAGE

SEE DETAIL DWG

STEEL CAGE

AE04

AE04

DRYER

DRYER

MACHINE

WASHING

MACHINE

WASHING

SINK

LAUNDRY

S.S.

FD

FD

W150 W150 W150W150

W

W

W

W

W

W

W100 W100

W

W

W

W

W

D3

W

W

W

W150 W150

W90 W90

W

ENLARGED PARTIAL FLOOR PLAN

15mm THK. GWB

50mm METAL STUD @ 450mm O.C.

15mm THK. GWB

50mm METAL STUD @ 450mm O.C.

(FLOOR TO FLOOR)

15mm THK. GWB

(FLOOR TO FLOOR)

150mm METAL STUD @ 450mm O.C.

(FLOOR TO FLOOR)

15mm THK. GWB

(FLOOR TO FLOOR)

50mm METAL STUD @ 450mm O.C.

15mm THK. GWB

(FLOOR TO FLOOR)

100mm METAL STUD @ 450mm O.C.

(FLOOR TO FLOOR)

15mm THK. GWB

L E G E N DL E G E N D

EXISTING CMU OR METAL WALL

REPLACE EXISTING WINDOW

50mm THK STUD WALL WITH GWB

100mm THK STUD WALL WITH GWB

150mm THK STUD WALL WITH GWB

90mm THK STUD WALL WITH GCWT

WOOD DOOR WITH FRAME

STEEL DOOR WITH FRAME

LOCATION OF STRUCTURAL STEEL

EXISTING KITCHEN WINDOW

BLAST RESISTANT WINDOW

(FLOOR TO FLOOR)

15mm THK. GWB

(FLOOR TO FLOOR)

150mm METAL STUD @ 300mm O.C.

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

GCWT ON LIQUID WATERPROOFING CEMENT(GWB ABOVE CEILING)

50mm METAL STUD @ 300mm O.C.

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

GCWT ON LIQUID WATERPROOFING CEMENT

EXISTING CMU OR METAL

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

GCWT ON LIQUID WATERPROOFING CEMENT

GCWT

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

90mm METAL STUD @ 300mm O.C.

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

GCWT ON LIQUID WATERPROOFING CEMENT

GCWT

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

50mm METAL STUD @ 300mm O.C.

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

GCWT ON LIQUID WATERPROOFING CEMENT

GCWT ON LIQUID WATERPROOFING CEMENT

MORTAR BED ON MEMBRANE SHEET AND METAL LATH

150mm METAL STUD @ 300mm O.C.

AND LEGEND

ENLARGED PARTIAL FLOOR PLAN,

AE 08

SCALE : 1 / 100

2F BATH, FLOOR STRUCTURAL REINFORCEING PLAN

A B

V A

R

V A

R

V A

R

C-100 x 50 x 20 x 3.2T @ 300mm (MIN. 8EA PER EACH BATH)

FULLY WELDED TO EXISTING PURLIN WITH 5T L-BRACKET

EXISTING PURLIN EXISTING STRUCTURAL STEEL

V A

R

V A

R

V A

R

- 100 x 50 X 3.2T

FULLY WELDED TO DECK PLATE

ON WELDED WIRE FABRIC, WELED TOGETHER

DECK PLATE (1.6T, H=50mm, WELDED TO EXISTING STEEL STRUCTURE)

202b

BATH

202b

BATH

102b

BATH

AEA

B

C

E

F

AE

D

08 08

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

10 52 AE-08

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

AE 08

SCALE : 1 / 25

AE 08

SCALE : 1 / 25

BATH & LAVATORY CABINET PLAN

12.5mm GYPSUM BOARD

(WATER RESISTANT TYPE)

12.5mm GYPSUM BOARD

(WATER RESISTANT TYPE)

12.5mm GYPSUM BOARD

SD

MG

TB

RH

SMHD

SMHD

TB

RH

SD

TTDTTD

WC WC WC

GCWT-1

GCWT-1

GCWT-1GCWT-1

GCWT-2

GCWT-2

(CURVED TYPE, SST 32mm DIA.)

SLOPE

MARBLE TOP

ARTIFICAL

(CURVED TYPE, SST 32mm DIA.)

BATH & LAVATORY CABINET ELEVATIONS

1.

2.

3.

4.

NOTE

O / MA SPECIFICATION, DISTANCE DIMENSION AS O/MA STD. DETAIL BOOK.

BATH ROOM ACCESSORIES SIZES AND QUALITY FOLLOW TO ASTM AND

NON-SLIP CERAMIC TILES, SIZE 200mm X 200mm

FLOOR FINISH MATERIALS OF BATHROOM & LAUNDRY ROOM SHALL BE

GLAZED CERAMIC TILES, SIZE 400mm X 250mm

WALL FINISH MATERIALS OF BATHROOM & LAUNDRY ROOM SHALL BE

RECESSED TYPE

W/ 2-3 DIA

BRASS HOOK

@ 500 OC

FHWS

A B C D E F

WATERPROOFING

METAL LATH

MEMBRANE ON

SOAP HOLDER

PORCELAIN

ON LIQUID WATERPROOFING CEMENT

GCWT WITH BOND COAT

(COLOR-MATCH WITH FEILD TILE)

MORTAR BED

6mm DIA. EXP BOLT

20x90 WOOD

STRIP WITH 2mm THK

STAINLESS STEEL

COVER

BRASS HOOK

WITH 3mm DIA.

FLAT HEAD MACHINE SCREW

SMHD (SHELF METAL HEAVY DUTY) LENGTH AS SHOWN ON PLAN.

m m m m

5.

AE 08

NONSLIP CERAMIC TILE NONSLIP CERAMIC TILE

LIGHT

(SEE ELEC DWG)

SHOWER CURTAIN WITH RODSHOWER CURTAIN WITH ROD

MIRROR GLASS

(1000mm X 1000mm

WITH FRAME)

LAVATORY CABINET

6.

CAULK AT ALL THE INCORNER OF TILE FINISHED WALL AND JOINT.

CORNER BEAD SHALL BE INSTALLED AT ALL THE OUTCORNER OF TILE FINISHED WALL.

SHOWER SOAP HOLDER DETAIL (TYP)

AE 08

5 HOOK DETAILS (TYP)

NOT TO SCALENOT TO SCALE

& HOOK DETAIL AND NOTE

CABINET ELEVATIONS, SHOWER SOAP HOLDER DETAIL

BATH & LAVATORY CABINET PLAN, BATH & LAVATORY

2F BATH, FLOOR STRUCTURAL REINFORCEING PLAN,

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

11 52 AE-09

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

DN DN

FLOOR: 1

BUILDING: 575

BUILDING: 575

FLOOR: 2

UP UP

MECH. RM.

CORRIDOR

1st FLOOR PLAN

2nd FLOOR PLAN

FIN FL

EQ.EQ.

INSERT

MODULE

WINDOWS

INSERT

2 STRIP

"2 -11

9"

9"

(SEE NOTE)

WHITE LETTERS

BACKGROUND

STANDARD BROWN

7"

EQ.7"EQ.

"2 -11

12"

ROOM IDENTIFICATION

TYPE "A"

MISC IDENTIFICATION

TYPE "B"

EXISTING DOOR VIEWER

FIN FL

EQ.EQ.

TYPE "C"

12"

VIEWER

DOOR

EXISTING

Storage

4" Min. 4" Min.

4’-0"

202 203 204 205

101 105 106102 Laundry

Coom Rm

Jan

Storage

AE 09

2 INSULATION / SIGNAGE / STRUCTURAL STEEL LOCATION PLAN

NOT TO SCALE

BUILDING IDENTIFICATION

NOTES

NOTES

2. NOS. ARE TWO PLACES PER EACH BUILDING.

COLOR AND HGT OF LOCATION WITH DPW.

- CONTRACTOR SHALL VERIFY NUMBER, SIZE,

1. BUILDING IDENTIFICATION NUMBER.

AE 09

NOT TO SCALE

SIZE & MOUNTING LOCATION OF SIGNAGE

1. ROOM NUMBERS SHALL BE AS SHOWN SIGNAGE PLAN.

2. LETTER TYPE SHALL BE "HELVETICA MEDIUM"

3. SIGN MESSAGE COPY, LETTER TYPE & LOCATION WILL BE CORDINATED WITH THE CONTRACTING OFFICER AND USING AGENCY BY THE CONTRACTOR.

100mm THK INSULATION

100mm STUD WITH

INSULATION

50mm THK

INSULATION

50mm THK

INSULATION

50mm THK

INSULATION

50mm THK

100mm THK INSULATION 100mm THK INSULATION100mm THK INSULATION

50mm THK INSULATION

50mm THK INSULATION

INSULATION

50mm THK

INSULATION

50mm THK

100mm THK INSULATION 100mm THK INSULATION

INSULATION

50mm THK

INSULATION

50mm THK

INSULATION

50mm THK

INSULATION

50mm THK

INSULATION

50mm THK

NOTES

1. - LOCATION OF STRUCTURAL STEEL

AE 10

SEE DETAIL DWG

2. INSULATION

- MINERAL FIBER BLANKET INSULATION

ASTM C665, TYPE "III" or KS L 9102 (ALUMINUM FOIL FACED TYPE)

ATYPE BTYPE CTYPE

AE 09

SCALE : 1 / 25

KITCHEN CABINET ELEVATION

AE09

A

B

12.5mm GYPSUM BOARD

MARBLE TOP

ARTIFICAL

GCWT-1

GCWT-1GCWT-1

BOARD

GYPSUM

15mm

BOARD

GYPSUM

15mm C

L G H

LOCATION OF SIGNAGE AND NOTE

STEEL LOCATION PLAN, SIZE & MOUNTING

INSULATION / SIGNAGE / STRUCTURAL

KITCHEN CABINET ELEVATION,

A B

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AS SHOWN

ARCHITECTURAL

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

12 52 AE-10

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

WIRE FABRIC

#10Ga. WOVEN

WIRE FABRIC

#10Ga. WOVEN

L-50 X 50 X 4 THK

STL. FRAME

L-50 X 50 X 4 THK

STL. FRAME

DOUBLE SWINING DOOR

1 - HASP HINGE A83231

4 - HINGES A8381

PLYWOOD

12 THK

PLYWOOD

12 THK

L-50 X 50 X 4 THK

STL. FRAME

DOUBLE SWINING DOOR

1 - HASP HINGE A83231

4 - HINGES A8381

ALL JOINT SHOULD BE WELED1.

2.

NOTE

AE 10

2 CAGE DETAIL

SCALE : NOT TO SCALEAE 10

SCALE : NOT TO SCALE

EXISTINT STRUCTURAL STEEL COLUMN COVER DETAIL

1 1/2" DIA

SST PIPE

AE 10

SCALE : NOT TO SCALE

STAIR HANDRAIL DETAIL

" DIA EXP BOLTS AT 1208

33-

APART (PROVIDE 3#8" DIA BOLTS

DIA BOLTS WITH EXP ARE FILLED)

" THK16

1" DIA. 2

SST PIPE RAILING

CHROME FINISH STL FLANGE

WITH FASTENERS

A

END WALL RAILING

"2

12" EXP. BOLT8

@ EA. BRACKET

STL. BRACKET

& HANDRAIL

B

WALL BRACKET

T O

F

IN

F L R

T R

E

C

HANDRAIL DETAIL

AE 10

SCALE : NOT TO SCALE

2ND FLOOR CORRIDOR GUARD RAIL DETAIL

IR

S

IN

G

A

CORRIDOR SECTION (TYP)

B

GUARD RAIL DETAIL

EXISTING COLUMN

STEEL PIPE GUARD RAIL

42.7mm DIA. 2T

42.7mm DIA. 2T STEEL PIPE POST

27.2mm DIA. 2T STEEL PIPE

" O.C.(TYP)2

1BALUSTER @ 3

42.7mm DIA. 2T STEEL PIPE

STEEL FLANGE WITH

" DIA. EXP BOLTS4

G U

A R

D R

A

IL

H

G T

(M A

X

(M A

X

(M A

X

4’-1"

(1254mm)

(1630mm)

5’-4"

(100mm)

4"

(146mm)

6"

(100mm)

4" 1"

(30mm)

EXSTING

STAIR WALL

REPL EIFS

& PAINT

EXST WALL

(76.2mm)

3"

375mm

EXISTING COLUMN

STEEL PIPE GUARD RAIL

42.7mm DIA. 2T

WELDED TO EXST COLUMN

42.7mm DIA. 2T STEEL PIPE

27.2mm DIA. 2T STEEL PIPE

" O.C.(TYP)2

1BALUSTER @ 3

STEEL FLANGE WITH

" DIA. EXP BOLTS4

42.7mm DIA. 2T STEEL PIPE POST

@ 4’-0" OC(MAX)

@ 4’-0" OC(MAX)

G U

A R

D R

A

IL

H

G T

(M A

X

(M A

X

(M A

X

C

RAILING ANCHOR

2EA

SCREWS

FLANGE

STEEL

42.7mm DIA. 2T

STEEL PIPE POST

WELDED TO PIPE POST

STEEL PLATE 5T

(150mm X 150mm)

D

GUARD RAIL DETAIL

PRODUCT : HIT-HY 150

STEEL PIPE GUARD RAIL

42.7mm DIA. 2T

42.7MM DIA 2T STEEL PIPE

WELDED BOTH SIDE

EXST FLOOR EXISTING COLUMN

NOTES

* MANUFACTURE SHALL BE "HILTI" OR APPROVED EQUAL STANDARD

1. DESCRIPTION FOR GROUTING CHEMICAL

2. THE CONTRACTOR SHALL COMPLY WITH THE MANUFACTURER’S GUIDE.

FILLED WITH GROUTING CHEMICAL

FILLED WITH

GROUTING CHEMICAL

STAIR HANDRAIL DETAIL AND NOTE

GUARD RAIL DETAIL,

DETAIL, CAGE DETAIL, 2ND FLOOR CORRIDOR

EXISTINT STRUCTURAL STEEL COLUMN COVER

CAGE TOTAL : 10 EA

D - 15 - 30J1-00572-5J

KIM, CHI SOP

MUN, SON KI

13 52

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

SHEET OF

UNITED STATES ARMY GARRISON DAEGU

DIRECTORATE OF PUBLIC WORKS

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

UNIT #15746, APO AP 96218-5746

DATE:

AE-11

CAMP WALKER

(SENIOR ENLISTED QUARTERS), BLDG. #575

CONVERSION OF BARRACK TO SEQ

MM

STOOP / LAMP

CONC.

SURFACES MATERIAL FINISH COLOR REMARKS

FOUNDATION

*WALL

ROOF

CANOPY EXST METAL

EXIST CONC.

STAIR EXST CONC

HANDRAILS

GUARDRAILS ’’

PAINT *

F.F. *NEW ALUM

CLG. HTG.

CEILING

CLRFNSHMATCLRFNSHMAT

WALL

HGTCLR

WAINSCOT

REMARKS

FNSHMATCLRFNSHMAT

BASE

CLR

FLOOR

FNSHMAT

ROOM NAMEROOM NO.

NEW METAL

PAINT *

PAINT *

WINDOW / FRAME

DOOR / FRAME

S E

C O

L O

NEW METAL

F.F.

INSUL.)

EIFS (WITH

: SELECT BY COR OR USING AGENCY

EXIST

EXST CONC

WHOLE BUILGING OF BLDG #575 AND MECH ROOM.

ACRYLIC FLUID-APPLIED WATERPROOFING SYSTEM

NEW SST. F.F.

F.F.

CORRIDOR CEILING

1ST & 2ND

NEW METAL

: SELECT BY COR OR USING AGENCY

* *GWB

NEW

*F.F. GWB

NEW

LIVING ROOM105-106

101-102

*F.F. BED ROOM105a-106a

101a-102a

*BATH ROOM F.F. F.F.

GCWT

NEW

* *GWB

NEW

105b-106b

101b-102b

CLOSET

WALK-IN

*F.F. 105c-106c

101c-102c

KITCHEN

105d-106d

101d-102d

STORAGE

COMM ROOM103

103a

JANITOR ROOM

F.F. LAUNDRY 104

104a

CONC.

EXST.

ROOM

MECHANICAL

VARIOUS

F

IR

S T

F L O

201-205 LIVING ROOM

BED ROOM201a-205a

BATH ROOM201b-205b

CLOSET

WALK-IN 201c-205c

INTERIOR FINISH SCHEDULE (S-575) EXTERIOR FINISH SCHEDULE

AND EXTERIOR FINISH SCHEDULE

INTERIOR FINISH SCHEDULE

(DECO) TILE

NEW VCT

(DECO) TILE

NEW VCT

WOOD

NEW

PAINT

VARNISH

OAK

WOOD

NEW

PAINT

VARNISH

OAK GWB

NEW

* GWB

NEW

FLOOR TILE

NEW NON-SLIP

RESISTANT TYPE

12.5MM THK. GWB WATER

(DECO) TILE

NEW VCT

WOOD

NEW

PAINT

VARNISH

OAK GWB

NEW

* GWB

NEW

(DECO) TILE

NEW VCT

WOOD

NEW

PAINT

VARNISH

OAK GCWT

NEW

F.F. * GWB

NEW

*F.F. *

F.F. *(DECO) TILE

NEW VCT

WOOD

NEW

PAINT

VARNISH

OAK GWB

NEW

* GWB

NEW

(DECO) TILE

NEW VCT

F.F. * WOOD

NEW

PAINT

VARNISH

OAK GWB

NEW

* GWB

NEW

FLOOR TILE

NEW NON-SLIP

GCWT

NEW

F.F. * GWB

NEW

GCWT

NEW

F.F. * GWB

NEW

EXST EXST

KITCHEN201d-205d

* *GWB

NEW

*F.F. GWB

NEW

*F.F.

*F.F. F.F.

GCWT

NEW

* *GWB

NEW

*F.F.

(DECO) TILE

NEW VCT

(DECO) TILE

NEW VCT

WOOD

NEW

PAINT

VARNISH

OAK

WOOD

NEW

PAINT

VARNISH

OAK GWB

NEW

* GWB

NEW

FLOOR TILE

NEW NON-SLIP

(DECO) TILE

NEW VCT

WOOD

NEW

PAINT

VARNISH

OAK GWB

NEW

* GWB

NEW

(DECO) TILE

NEW VCT

WOOD

NEW

PAINT

VARNISH

OAK GCWT

NEW

F.F. * GWB

NEW

*F.F. *

RESISTANT TYPE

12.5MM THK. GWB WATER

PT-2

PAINT

PT-2

PAINT

PT-2

PAINT

PT-2

PAINT

PT-2

PAINT

PT-2

PAINT

PT-2

PAINT

PT-2

PAINT

PT-3

PAINT

PT-3

PAINT

PT-4

PAINT

PT-3

PAINT

PT-3

PAINT

PT-3

PAINT

PT-3

PAINT

PT-3

PAINT

PT-3

PAINT

PT-3

PAINT

PT-3

PAINT

PT-4

PAINT

PT-3

PAINT

PT-3

PAINT

PT-1

MISC MATERIAL & COLORFLOOR MATERIAL & COLOR

WALL / BASE MATERIAL & COLOR

PT-2

OR APPROVED EQUAL

BY BENJAMIN MOORE

COLOR: MARITIME WHITE 963

LATEX / EGGSHELL

PAINT

PT-3

CFT-1

WCB-1

OR APPROVED EQUAL

BY BENJAMIN MOORE

COLOR: SILVER GRAY #2131-60

SEMI-GLOSS

PAINT

OR APPROVED EQUAL

BY BENJAMIN MOORE

COLOR: DISTANT GRAY #OC-68

SEMI-GLOSS

PAINT

CS-1

OR APPROVED EQUAL

DUR-A-SHIELD

PRIMER & SEALER

DUR-A-FLEX

CONCRETE FLOOR SEALER

GCWT-1

OR APPROVED EQUAL

BY DALTILE

CANALETTOGIALLO

325 X 325 X 7MM THK,

GLAZED CERAMIC WALL TILE

GCWT-2

OR APPROVED EQUAL

BY DALTILE

LA COSTA, GOLD #LC03

300 X 300 X 7MM THK

GLAZED CERAMIC WALL TILE

SSM-1

OR APPROVED EQUAL

This is the start of the file's text. The full file is on GovTribe.