W91QEX-20-Q-0008-P0001 LRC Forklift Lease (Add PWS).pdf

PDF 413 KB Posted

Attached to
Forklift Lease (3k and 6k)
Solicitation number
W91QEX-20-Q-0008
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0011418514

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to add the Performance Work Statement (PWS). The POC for this action is Catherine Richardson, Contracting Officer, catherine.p.richardson.civ@mail.mil.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 5

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W91QEX20Q0008

X 9B. DATED (SEE ITEM 11)

09-Jan-2020

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

U0001

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

09-Jan-2020

CODE

410TH CSB-MIAMI DIVISION

9301 NW 33RD ST

DORAL FL 33172-1202

W91QEX 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION C - DESCRIPTIONS AND SPECIFICATIONS

The following have been added by full text:

PERFORMANCE WORK STATEMENT

PERFORMANCE WORK STATEMENT

Logistics Readiness Center – Miami

Supply and Services Division, Central Receiving Point

Forklifts Rental with Maintenance Prevention Services

1. GENERAL. The Logistics Readiness Center – Miami (LRC-Miami) has a requirement for the rental, full maintenance and inspection, of two (2) electric-powered 6,000 lbs and 3,000 lbs cushion tire forklifts.

2. SCOPE. The contractor shall provide two (2) electrical rental cushion tire forklifts and perform preventive maintenance and inspections at least once every month or as often as needed on both, a 6,000 lbs forklift and a 3,000 lbs forklift. Forklifts will be housed in the Central Receiving and Distribution Point warehouse located at Westpointe Business Park, LRC

– Miami, Supply and Services Division, 8900 NW 35th Lane, Suite 150, Doral, Florida 33172-1217. The contractor shall perform inspections in accordance with manufacturer’s recommended service procedures.

3. BASIS OF AWARD. This requirement shall be awarded to the Lowest Price – Technically Acceptable quoter. The successful quoter shall have acceptable past performance.

4. SPECIFIC TASKS.

4.1. The contractor shall provide two (2) electric-powered cushion tire forklifts.

The contractor shall provide:

4.1.1. One (1) for 6,000 lbs electric-powered cushion tire forklift with the following salient characteristics:

24 “Load Center 5,500 lbs Net Rated Capacity 187” MFH with Slide-Shifter Attachment 36 Volts System Type E Rated

0.3 Section Hydraulic Valve Power Steering

216” Triplex Mast 87” Overall Lowered Height 62.8” Free Lift with 5 degree Forward tilt and 6 degree Back tilt 90” Wide ITA Class H Carriage 48” High Load Backrest 85” High Overhead Guard 3” Hydraulic Support Group 48” Long Pallet Forks Side Shifter Strobe Lights Audible Back-up Alarm Compliant with OSHA Standards

W91QEX20Q0008

4.1.2 One (1) for 3,000 lbs electric-powered cushion tire forklift with the following salient characteristics:

24 “Load Center 2,500 lbs Net Rated Capacity 154” MFH with Slide-Shifter Attachment 36 Volts System Type E Rated

0.3 Section Hydraulic Valve Power Steering

190” Triplex Mast 87” Overall Lowered Height 35” Free Lift with 5 degree Forward tilt and 5 degree Back tilt 68.5” Wide ITA Class H Carriage 35” High Load Backrest 83” High Overhead Guard 3” Hydraulic Support Group 36” Long Pallet Forks Side Shifter Strobe Lights Audible Back-up Alarm Compliant with OSHA Standards

4.2 The contractor shall provide one (1) industrial battery 1105 AMS, heavy-duty battery charger with the following salient characteristics:

Trickle charge feature Three (3) phase 208/220/240 volts Fully automatic type of charger Capable of charging a 3,000 lbs and/or a 6,000 lbs forklift

4.3 The contractor shall perform monthly preventive maintenance and forklifts inspections at the end of each month. All maintenance, repairs, parts & labor shall be inclusive of the rental agreement price.

4.3.1 If maintenance is need prior to the monthly inspections, the contractor shall have 24 hours to respond and repair the forklift once notified or provide a loaner until forklift is repaired.

4.3.2 Inspections and preventive maintenance shall be performed at the LRC-Miami CRDP (warehouse) located at 8900 NW 35th Lane, Suite 150, Doral, FL 33172-1217.

5. GOVERNMENT POINT OF CONTACT (POC).

5.1 The Government point of contact is Mr. David Rivera-Ortiz, LRC-Miami, Chief, Plans and Operations Division; phone 305-437-2699, email is d avid.rivera-ortiz.civ@mail.mil.

5.2 The Alternate point of contact is Ms. Carla Anderson, LRC-Miami, Chief, Supply and Services Division, phone 305-437-2700, email is c arla.l.anderson15.civ@mail.mil.

W91QEX20Q0008

(End of Summary of Changes)

File details come from the government source that posted it. Updated .