Technical Data Packet for ASC# FY18-2958 Security Hardware
Quantity and Description needed are as follows:
Quantity Item Description
15 HES Electronic Strike, Heavy Duty, 12/24VDC, Part # 1006CLB or equal. Technical Specifications: Electric Strike, For Use With Cylindrical Locks and Mortise Locks Without a Deadbolt, Performance Heavy‐Duty, Failure Mode Fail Secure, Input Voltage Electric Strike, Heavy‐Duty,12/24VDC, Door Frame Type Metal/Wood, Faceplate Width 1‐1/4", Faceplate Height 4‐7/8", Faceplate Depth 1‐11/16", Pull Force 3070 lb., Grade 1, Fire Rated 3 hr., Finish 630 Dull Stainless Steel, Material Stainless Steel, Bolt Throw Up to 1", Strikes Exceeds 1,000,000 Cycles, Features Non‐Handed, Internally Mounted Solenoid, Plug In Connector, Full Keeper Shims for Horizontal Adjustment, Standards UL 10C Listed, Can4‐S104, ANSI A250.13‐2003, UL 1034 Listed, ANSI/BHMA A156.31,ASTM‐E152 Includes Strike Body, (3) Face Plates and Mounting Hardware
6 V‐Station 4G(MIFARE & DESFIRE) Part # SWH‐4GSTSG or equal. Technical Specifications:
Large Template Storage Capacity (10,000 in 1:N; 100,000 in 1:1, or 50,000 in 1:N with bins), Single‐,Two‐Factor or Three Factor Authentication Integrated Card Reader
(MIFARE/DesFire), Field Replaceable Sensors, Backwards Compatible, Remote Device
Management, IP Connectivity (LAN, POE), Flush Mounted, ''Quick ‐ Tilt'' Access for easy maintenance, Time & Attendance Ready, Standalone Door Access Control (SDAC)
Capabilities, Length: 159 mm (6.27"), Width: 165 mm (6.47"), Depth: 82 mm (3.24")
15 SENTROL High Security Armored SPST 3/16 Part # 2707A or equal. Technical
Specifications: High Security Contacts w/Armored Cable, Triple Biased, SPDT, 3/16” to
5/8” Gap, Size, Single Pole‐Double Throw, 3’ Stainless Steel Armored Cable, Voltage 30V
AC/DC maximum, Current 0.25A maximum, Power 3.0W maximum, Dimensions (LxWxH)
4.25 x 1.50 x .75 in. (10.80 x 3.81 x 1.91 cm), Material Brushed anodized aluminum, Listing UL‐634
10 Allegion Readers & Cards Part # MTK15‐B or equal. Technical Specifications: Proximity‐‐
Up to 5", MIFARE‐‐Up to 4", MIFARE DESFire EV1‐‐Up to 2", PIV Credential‐‐Up to 2.5", Weight: 9.1 oz, Dimensions: 5.1" x 3.25" x 1.9", Accommodates interior, exterior, metal, and non‐metal installation environments, Recognizes most proximity, aptiQ MIFARE
Classic, and aptiQ MIFARE DESFire EV1 credentials in one multi‐technology reader, FIPS
201‐1 Compliant, NFC Compatible, Quick‐connect cable for easy installation, Easy‐to‐ install mounting bracket, Tri‐state LED (red, green, amber) visual indicator and audio feedback representing status and activity information, easily discernible for the audibly or visually impaired, Wiegand output for simple interface with most access control panels, Multiple color options, Anti‐bacterial keypad
2 MORPHOTRAK MSO 300U Part # SWH‐MSO‐300 or equal. Technical Specifications:
Authentication < 0.7 sec (including detection, encoding and matching), Identification <
0.9 sec in 1:1000 mode (including detection, encoding and matching), meets and exceeds requirements of FIPS 201, false acceptance rate (FAR) is configurable down to 10‐8, , Versatile terminal that carries out both enrollment and comparison operations, Choice of fingerprint template formats: ANSI/INCITS 378, ISO 19794‐2 or Morpho proprietary, CE, FCC and RoHS compliant, Smartcard reader, Fake finger detection
10 LENEL Intelligent System Controller‐12 Part # LNL‐3300 or equal. Technical
Specifications: Lenel Compatible, On‐board high‐speed Ethernet 10/100Base‐T upstream port provides up to 8 times higher throughput than serial‐to‐Ethernet converters. DHCP and fixed IP addressing supported, DNS device naming through DHCP extended commands, Host dual path communication enabled ‐ on‐board Ethernet, TCP/IP, direct wire (RS‐485, 2‐wire multidrop capable), or dialup communications, 15 MB of available on‐board, non‐volatile flash memory, Battery‐backed, non‐volatile storage of
50,000 events, Firmware stored in flash memory, background download of firmware updates supported, 12 or 24 VDC input power, Supports up to 16 different formats (8 card formats and 8 asset formats), Biometric template storage support for Schlage
Recognition Systems®, Bioscrypt®,and Identix®, Enhanced anti‐passback capabilities, Up to 32,000 access level permissions, 255 holidays with grouping, 255 timezones, each with
6 intervals, Elevator control support for up to 128 floors, Alarm masking, Individual extended held open and strike times (ADA required), Up to 9‐digit user PIN codes, Status
LEDs for heartbeat & battery status, upstream and downstream communication, and memory write status, Two dedicated inputs for tamper and power failure status, Advanced Encryption Standard (AES) 128‐bit algorithm for communications, Primary
Power (DC or AC) * The LNL‐3300 is for use in low voltage, power‐limited, class 2 circuits only. DC input: 12 or 24 VDC ± 15%. 500 mA maximum, AC input: 12 VAC ± 15%. 400 mA
RMS, Memory and Clock backup 3 V lithium, type BR2325, BR2330, CR2330, Communication Ports Primary (Ethernet) Port 0: 10/100Base‐T Ethernet high‐speed port, Secondary Upstream Port 1: RS‐485 (2‐wire) or RS‐232 9600 to 115.2 Kbps async, optional Ethernet serial server, Downstream Ports 2‐3: RS‐485 (2‐wire) 9600 to 38.4 Kbps async, Inputs: Cabinet Tamper Monitor: Unsupervised, dedicated, Power Fault Monitor:
Unsupervised, dedicated, Wire Requirements: Power: 1 twisted pair, 18 AWG, RS‐485:
24 AWG twisted pair(s) with shield, 4000 ft.,(1219 m) maximum, RS‐232: 24 AWG, 25 ft.
(7.6 m) maximum, Inputs: Twisted pair, 30 ohms maximum, Environmental:
Temperature: Operating: 32° to 158° F (0° to +70° C), Storage: ‐67° to 185° F (‐55° to +85°
C), Humidity: 0 to 95% RHNC, Mechanical: Dimensions: 5 x 6 x 1 in. (127 x 152.4 x 25 mm), Weight: 4 oz. (115 g) nominal, Approvals: FCC Part 15, CE, RoHS, UL 294, UL 294, UL 1076, ULC CSA‐C22.2, CAN/ULC‐S319‐05, cUL/ORD‐C1076
12 LENEL Dual Reader Interface Module Part # LNL‐1320 or equal. Technical Specifications:
Lenel Compatible, 12 or 24 VDC power supply, Supports Data1/Data0, Clock/Data and
Lenel OSDP‐compatible RS‐485 readers and keypads, Downloadable firmware, Six Form‐C
5 A at 28 VDC relay outputs, Up to 16 different formats (8 card formats and 8 asset formats), Issue code support for magnetic and Wiegand formats, Door contact supervision (open/closed), REX push‐button monitor, Strike control output, Bicolor reader status LED support and 2‐wire LED support, Beeper control, Dedicated tamper and power failure circuits, Support for offline reader access mode, On‐board jumpers for termination, On‐board regulator allows 12 VDC reader support from 24 VDC power source, DIP switch‐selectable addressing, Primary Power 12 to 24Vdc ±10%, 550mA maximum (plus reader current), 12Vdc @ 450mA (plus reader current) nominal, 18.41
BTUs, 24Vdc @ 270mA (plus reader current) nominal, 22.09 BTUs, Outputs: 6 outputs, Form‐C, 5A @ 28Vdc, resistive,Inputs: 8 unsupervised/supervised, standard EOL: 1k/1k ohm, 1% 1/4 watt 2 unsupervised, dedicated for cabinet tamper and UPS fault monitoring, Reader Interface Reader power: 12Vdc ±10% regulated, 125mA maximum each reader (jumper selectable and input voltage (VIN) must be 20Vdc minimum) or 12 to 24Vdc ±10% (input voltage passed through) 125mA maximum each reader, Reader
Port Compatibility Wiegand Data 1/Data 0 Magnetic Clock/Data, F/2F Single Wire, Open
Supervised Device Protocol, Mechancial Dimension: 6” (152mm)W x 8” (203mm)L x 1”
(25mm)H Weight: 11 oz. (312g) nominal, Environmental Temperature Operating: 32°F to
158°F (0°C to +70°C), Storage: ‐67°F to 185°F (‐55°C to +85°C), Humidity 0% to 95% RHNC, Compliance Approvals FCC Part 15, CE, RoHS, UL 294, UL 1076, ULC CSA‐C22.2, CAN/ULC‐
S319‐05, cUL/ORD‐C1076
WARRANTY: Contractor shall provide a manufacturer's warranty guaranteeing materials and workmanship performed against defects for a period of time that is common industry standard or better. This period shall begin upon the date of acceptance by the authorized Government representative. Contractor shall submit a written copy of the applicable warranty prior to final acceptance by the Government. All components shall be free from defects in materials and workmanship at the time of final acceptance by the Government.
POC: SCJ2-Justin Lewis
HQ USSOUTHCOM
9301 NW 33rd St Doral, Fl 33172
15 BOSCH DS151l Motion Sensor‐10 Part # DS151l‐C or equal. Technical Specifications:
Minimum Motion Sensing Distance 96", Maximum Motion Sensing Distance 10 ft , Power
Description: Input Voltage 24 V DC, Physical Characteristics: Color Black, Height 1.5", Width 6.3", Depth 1.5", Single or double door use, internal vertical pointability, Wrap‐ around coverage pattern, Selectable relay trigger mode, Selectable fail safe/fail secure modes, Wall or ceiling mountable, Externally visible activation LED
3 PELCO 16 Rack Encoder US Part # NET5516‐US or equal. Technical Specifications: Pelco Endura Compatability, Open Standards‐Based Architecture, MJPEG and H.264 Baseline, Main, or High Profile Compression, Dual‐Stream at up to D1; 30/25 Images per Second
(ips) per Stream, Analytics: Motion and Sabotage, Integrated Coaxitron and Pelco D and
Pelco P PTZ Protocols, Rack Mount design, ONVIF Profile‐S Conformance, COM Ports RS‐
422 RS‐485