Question: It seems the specifications are incomplete. Is there any additional documentation? Specifically, mechanical requirements and sensor output requirements are not present.
Answer: Mechanical requirements: Our test applications usually work best with spring-loaded probes. We custom mount sensors to each test frame and specimen using industry standard LVDT mounting blocks and bearing blocks. Sensor output: Our acquisition system is capable of interrogating a wide range of sensors. The simplest case would be a calibrated +/- 10 VDC sensor output.
Question: Would you have additional details of the electrical specifications for these LVDT’s and installation drawings if this has previously manufactured or if not then any dimensional requirements or limitations?
Answer:
Electrical specifications: The simplest case would be a calibrated +/- 10VDC output signal. Our acquisition system is capable of exciting and interrogating a wide range of sensors.
Mechanical/dimensional specifications: Our test applications usually work best with spring-loaded probes. We temporarily custom mount sensors to each test frame and specimen using industry standard LVDT mounting blocks and bearing blocks.