Text version
W9132T-15-T-0028
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time has changed from 28-Aug-2015 12:00 PM to 01-Sep-2015 12:00 PM.
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
SPECIFICATIONS
Uniaxial Load Frame Specifications
Requirements:
-Electromechanical, floor mount, dual column load frame, minimum 250kN capacity, speed range: 0.0001-500mm/min.
-Test enclosure to meet international safety standards -500N tension/compression load cell with required mounting hardware and adapters, class 5 accuracy from 1-100% -5kN tension/compression load cell with required mounting hardware and adapters, class 5 accuracy from 1-100% -Tension/compression load cell to match maximum frame load capacity (i.e. 250kN minimum) with required mounting hardware and adapters, class 5 accuracy from 1-100% -Computer with Windows 7 capable of running test software and collecting all test data, including 27” monitor, keyboard, and mouse, -Test software capable of controlling load frame in displacement and load control, 12 months updates and support, English version -Remote Hand set with emergency stop switch -6” diameter compression platens with required mounting hardware, 250kN capacity -2 to 2.5 inch diameter compression platens with required mounting hardware, 5kN capacity -10kN screw grips with required mounting hardware and adapters -Screw grip inserts: rubber, 0-1.00”, 5kN -Screw grip inserts: sawtooth, 0-1.00”, 5kN -4kN Dog Bone grips with 1” serrated inserts with required mounting hardware and adapters -250kN wedge grips with required mounting hardware and adapters -Wedge grip inserts: flat, serrated, 0” to 0.25-0.375”, 250kN -Wedge grip inserts: flat, serrated, 0.25-0.375” to 0.5-0.75”, 250kN -Wedge grip inserts: flat, serrated, 0.5-0.75” to 1.00-1.25”, 250kN -Wedge grip inserts: Vee, serrated, 0-0.25” to 0.375-0.50”, 250kN -Wedge grip inserts: Vee, serrated, 0.375-0.50” to 0.625-1.00”, 250kN -Wedge grip inserts: Vee, serrated, 0.625-1.00”, 250kN -250kN 3 and 4 point bend fixture, lower span 10-600mm, 10mm rollers, with required mounting hardware, adapters, or conversion kits -Quick release adapter to change grips listed quickly -One (1) Axial extensometer, 1” travel, 2” gage length; with all cables, connectors, and required conditioning units -One (1) Axial extensometer, 0.5” travel, 1” gage length; with all cables, connectors, and required conditioning units -Laser extensometer or video extensometer with all required mounting hardware, adapters, cables, and software.
-Laser or video extensometer target applicator for 1-2” gage length with ten (10) units of target tape and ten (10) units of target disks -Environmental chamber: -100 deg F to 600 deg F, +/- 10 deg F temp. control, Liquid Nitrogen cooled, window for laser extensometer use -Pull rods for use with environmental chamber, 250kN minimum -Pull rods for use with environmental chamber, quick release end, 5,000 lbf max -Onsite installation -Onsite calibration, certification, and force/speed/displacement verification -Onsite training for frame and software operation, 1 day, unlimited users -1 year service contract -3 year warranty -Delivery: 10 weeks ARO