Plans_Final_5SEP2018.pdf

PDF 2 MB Posted

Attached to
SOLICITATION - Electrical Upgrades at the Thomaston Dam
Solicitation number
W912WJ18B0031
Issued by

About this file

Updated Plans Document

View the file

Other files

File Type Posted
W912WJ18B0031_0002.pdf PDF
W912WJ18B0031-0001.pdf PDF
Specs_Final_4SEP2018.pdf PDF
Plans_W912WJ18B0031.pdf PDF
Specs_W912WJ18B0031.pdf PDF
W912WJ18B0031.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

N E

W E

N G

L A

N D D

IS

T R

IC

T

V

IR

G

IN

IA

R

O A

D

C O

N C

O R

D

M A

-2

S C

A L E

S H

E E

T

D R

A W

IN

G C

O D

E

O F

F Y E

L E

C T

R

IC

A L E

Q U

IP

M E

N T U

P G

R A

D E

T H

O M

A S

T O

N D

A M

T H

O M

A S

T O

N

C O

N N

E C

T

IC

U T

W

W J

B

H O

U -T

H -1

G-001

C O

V E

R S

H E

E T A

N D I

N D

E X

D

N G

U Y

E N

D

N G

U Y

E N

J

C L

IN

E

M J

U R

C

IC

A N

S I

D :1

A U

G U

S T of Engineers

US Army Corps

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

New England District

EXISTING/DEMOLITION SITE PLAN AND DETAIL

GATEHOUSE DEMOLITION PLAN

OPERATORS QUARTERS DEMOLITION PLAN

ELECTRICAL ONE LINE DIAGRAM DEMOLITION

SITE PLAN NEW WORK

GATEHOUSE PLAN NEW WORK

OPERATORS QUARTERS PLAN NEW WORK

ELECTRICAL ONE LINE DIAGRAM INSTALLATION

ELECTRICAL PANEL & FEEDER SCHEDULES INSTALLATION

DESIGN FILESHEET NO.

G-001

INDEX TO DRAWINGS

SHEET TITLE

ED101

ED102

ED103

ED602

E-101

E-102

E-103

E-602

E-603

HOU-TH-120_G-001.DWG COVER SHEET AND INDEX

HOU-TH-120_ED101.DWG

HOU-TH-120_ED102.DWG

HOU-TH-120_ED103.DWG

HOU-TH-120_ED602.DWG

HOU-TH-120_E-101.DWG

HOU-TH-120_E-102.DWG

HOU-TH-120_E-103.DWG

HOU-TH-120_E-602.DWG

HOU-TH-120_E-603.DWG

E-001 HOU-TH-120_E-001.DWG ELECTRICAL ABBREVIATIONS, LEGENDS, AND GENERAL NOTES

FY18 ELECTRICAL EQUIPMENT UPGRADE

THOMASTON DAM

THOMASTON, CONNECTICUT

W912WJ18B0025

AUGUST 2018

NOT TO SCALE

VICINITY MAP

NOT TO SCALE

LOCATION PLAN

NOT TO SCALE

VICINITY MAP

OCEAN

ATLANTIC

NOT TO SCALE

VICINITY MAP

NOT TO SCALE

VICINITY MAP

MASSACHUSETTS

NEW

HAMPSHIRE

MAINE

CANADA

VT.

CONN.

R.I.

HARTFORD

PROV.

CAPE

COD

BOSTON

PORTSMOUTH

CONCORD

PORTLAND

AUGUSTA

BANGOR

N

TORRINGTON

WATERBURY

THOMASTON

NORTHFIELD

BRISTOL

WATERTOWN

B R

A N

C H B

R O

O K

N

PROJECT

LOCATION

THOMASTON

DAM

W912WJ18B0031

05 SEPTEMBER 2018

AutoCAD SHX Text

ATLANTIC OCEAN

E-001

L E

C T

R I C

A L

A

B B

R E

V I A

T I O

N S

L E

G E

N D

S

A N

D

G

E N

E R

A L

N

O T

E S

D

N

G U

Y E

N

D

N

G U

Y E

N

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

A U

G U

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C

N

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

P

F

E

N G

I N

E E

R S

N E

W

E

N G

L A

D

I S

T R

I C

T

V

I R

G I N

A

R

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

AMPERES

AMERICANS WITH DISABILITIES ACT

AMPERE INTERRUPTING CAPACITY

AUTHORITY HAVING JURISDICTION

ABOVE FINISH GRADE

AIR HANDLING UNIT

ABOVE FINISH FLOOR

AMERICAN WIRE GAUGE

CONDUIT

CIRCUIT

COLUMN

CIRCUIT BREAKER

CENTERLINE

BUILDING

COPPER

FAN COIL UNIT

ELECTRICAL CONTRACTOR

EXHAUST FAN

EMERGENCY

FIRE ALARM

ELECTRICAL METALLIC TUBING

GROUND FAULT INTERRUPTER

GROUND OR GROUNDING

FULL LOAD AMPERES

THOUSAND CIRCULAR MILS

GALVANIZED RIGID METALLIC CONDUIT

kcmil

FLA

FT

GFI

GRMC

GND,G

FEET

EM

EMT

F

FCU

FA

FUSE

CU

EC

EF

CB

CKT

COL

CL

AWG

C

BLDG

AHU

AIC

A

ADA

AFG

AFF

AHJ

PHASE

QUANTITY

ROOF TOP UNIT

TELEPHONE

SYMMETRICAL

POLYVINYL CHLORIDE

RIGID METAL CONDUIT

UNIT HEATER

TRANSFORMER

WEATHERPROOF

WATER HEATER

UNLESS OTHERWISE NOTED

UNDERGROUND OR UNDERGRADE

UNDERWRITERS LABORATORIES

WH

XFMR

WP

W

V

DELTA

WYE

WIRE

VOLT

UG

UL

UH

U.O.N.

SP

RTU

TEL

SYM

SPARE

PWR

QTY

PVC

RMC

POWER

KILOWATTS

LIGHTING

MISCELLANEOUS

MAIN LUGS ONLY

KILOVOLT AMPERES

MAIN CIRCUIT BREAKER

ASSOCIATION

NOT TO SCALE

PUSHBUTTON

NATIONAL ELECTRICAL

NATIONAL ELECTRIC CODE

NATIONAL FIRE PROTECTION

NTS

PNL

P

PB

PANEL

POLE

NEC

NEMA

NFPA

MCB

MLO

MISC

kW kVA

LTG

CABINET UNIT HEATERCUH

Ø

Y

LINE TYPE LEGEND

GENERAL NOTES:

MANUFACTURERS ASSOCIATION

ATS

AUTOMATIC TRANSFER SWITCH

PRI

PRIMARY

RCPT RECEPTACLE

RGS RIDGE GALVANIZED STEEL

SEC

S.E.

SERVICE ENTRANCE

SECONDARY

TWR TOWER

FS FUSED SWITCH (DISCONNECT)

ALL NECESSARY ADDITIONS AND ALTERATIONS TO EXISTING WORK SHALL BE INCLUDED IN THE CONTRACT AS REQUIRED TO

PROVIDE AND MAINTAIN A COMPLETE AND PROPER ELECTRICAL INSTALLATION. THIS WORK SHALL INCLUDE BUT NOT BE LIMITED TO:

1. RELOCATION OF EQUIPMENT TO ALLOW FOR WORK.

2. DISCONNECTION/RECONNECTION/REINSTALLATION OF EQUIPMENT TO ALLOW FOR CONTINUED OPERATION DURING THE WORK, TO INCLUDE TEMPORARY WORK.

3. RELOCATION OF PIPING AND DUCTWORK TO ALLOW FOR WORK.

4. VERIFICATION THAT EQUIPMENT TO BE TURNED OVER TO THE CONTRACTING OFFICER'S REPRESENTATIVE SHALL BE CLEAN

AND IN WORKING ORDER.

5. REMOVAL AND DISPOSAL OF UNUSED CONDUIT OR CONDUCTORS.

6. ABANDONMENT IN PLACE OF UNUSED CONDUIT WHERE CONCEALED IN FLOORS OR WALLS.

7. REMOVAL OF UNUSED CONDUIT FROM CEILINGS, EXPOSED AREAS, AND ACCESSIBLE LOCATIONS.

8. REMOVAL AND DISPOSAL OF ALL EQUIPMENT INDICATED TO BE DEMOLISHED.

9. VERIFICATION THAT THE EXISTING EQUIPMENT OF SYSTEM SHALL BE RESTORED TO ITS ORIGINAL OPERATING CONDITION

AFTER THE WORK OF THIS CONTRACT.

10. THE FILLING, SEALING, AND FINISHING OF EXISTING BUILDING PENETRATIONS, EXPOSED FROM DEMOLITION, TO MATCH

EXISTING ADJACENT BUILDING FINISHES.

SWITCH

S

HANDHOLE

UTILITY POLE

TRANSFORMER

SYSTEM GROUND OR EQUIPMENT GROUND

DELTA

GROUNDED WYE

METER

MOTOR STARTER

MOTOR

TRANSFER SWITCH

GENERATOR

FUSED DISCONNECT (SAFETY SWITCH)

CIRCUIT BREAKER

EQUIPMENT LEGEND

GENERAL ABBREVIATIONS

AutoCAD SHX Text

EXISTING CONDUIT/EQUIPMENT TO REMAIN

AutoCAD SHX Text

NEW CONDUIT/EQUIPMENT

EXISTING CONDUIT/EQUIPMENT TO BE DEMOLISHED

GATEHOUSE

E

R

V

I

B

I

D

G

E

HH#3

HH#2

HH#1

PARKING

AREA

S P

I L L W

A Y

S P

IL

L W

A Y

B R

ID

G

E

H

I

L

A

D

H

I

A

D

D

R

I

V

E

W

A

Y

PARKING LOT

LOCATION OF EXISTING

GENERATOR TO BE RELOCATED

OPERATORS

QUARTERS

PROJECT

OFFICE

OPERATORS

QUARTERS

PARKING

LOT

PROJECT

OFFICE

DRIVEWAY

H

I

A

D

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

ED101

E X

I S

T I N

G D

E M

O L I T

I O

N

S

I T

E

P

L A

N

A

T

A I L

D

N

G U

Y E

N

D

N

G U

Y E

N

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

A U

G U

A1

EXISTING SITE PLAN

SCALE: 1/64" = 1'-0"

D1

EXISTING UTILITY POLE ELEVATION

SCALE: NOT TO SCALE

D4

SITE PLAN ENLARGEMENT

SCALE: 3/32" = 1'-0"

GENERAL NOTES:

1. DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EXACT

LOCATIONS, DISTANCES, OR DIMENSIONS. CONTRACTOR IS TO VERIFY

MEASUREMENTS IN THE FIELD.

KEY NOTES:

DEMOLISH MAIN DISTRIBUTION PANEL. DEMOLISH WIRE & CONDUIT FROM THE

MAIN DISTRIBUTION PANEL TO THE 75KVA TRANSFORMER. RETAIN INCOMING

OVERHEAD UTILITY CONDUIT AND WIRES FOR REUSE.

COORDINATE WITH UTILITY TO DEMOLISH POLE-MOUNTED TRANSFORMERS,

METER, WIRE, CONDUIT, AND INDUCTORS ON UTILITY POLE.

COORDINATE WITH UTILITY TO DEMOLISH METER, WIRE, AND CONDUIT BACK

TO THE UTILITY POLE. DEMOLISH WIRE BETWEEN METER AND HOUSE PANEL.

FILL AND SEAL WALL PENETRATION TO MATCH EXISTING FINISH.

DEMOLISH ABANDONED BURIED CONDUIT AND ANY EXISTING WIRES WITHIN.

DEMOLISH CONDUCTORS IN EXISTING BURIED CONDUIT. RETAIN CONDUIT FOR

REUSE WITH NEW CONDUCTORS.

DEMOLISH CLOTHESLINE POSTS.

POLE MOUNTED

TRANSFORMERS

UTILITY METER

MAIN DISTRIBUTION

PANEL

EXISTING BURIED

CONDUITS

75KVA TRANSFORMER

UTILITY METER

PANEL PP

UTILITY METER

MAIN DISTRIBUTION

PANEL

TO 75KVA XFMR

TO GATEHOUSE

FROM UTILITY TRANSFORMERS

UTILITY COMPANY METERING

CURRENT TRANSFORMERS

N

0 8' 32'16'

0 128'64'32'

D

E

D

DOWN

UP

ED102

G A

T E

H O

U S

E

D

E M

O L I T

I O

N

P

L A

N

D

N

G U

Y E

N

D

N

G U

Y E

N

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

A U

G U

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

GENERAL NOTES:

1. DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EXACT

LOCATIONS OR DIMENSIONS. CONTRACTOR IS TO VERIFY LOCATIONS AND

DIMENSIONS IN THE FIELD.

KEY NOTES:

DEMOLISH EXISTING SWITCHBOARD. RETAIN BRANCH CONDUCTORS FROM

PANEL A FOR REUSE. RETAIN INCOMING SERVICE CONDUCTORS FOR REUSE.

RETAIN PANEL B FEEDER CONDUCTORS FOR REUSE. RETAIN 5KVA

TRANSFORMER FOR REUSE.

REMOVE GENERATOR ASSEMBLY AND RETAIN FOR REUSE. DEMOLISH WIRE

AND CONDUIT FROM THE GENERATOR TO TRANSFER SWITCH IN THE EXISTING

SWITCHBOARD ON THE ENTRANCE LEVEL. DEMOLISH COMBUSTION EXHAUST

PIPING. DEMOLISH FUEL SUPPLY TO GENERATOR BUT MAINTAIN DAY TANK

FOR USE WITH EXISTING FURNACE. FILL AND SEAL ROOF PENETRATION AS

NECESSARY.

DEMOLISH RADIATOR EXHAUST DUCT. RETAIN SHEET METAL BOX COVERING

THE WALL OPENING.

REMOVE BATTERY CHARGER AND RETAIN FOR REUSE.

DEMOLISH EXISTING HYDRAULIC PUMP MOTORS, ASSOCIATED STARTERS,

CONDUIT, AND WIRE.

PANEL A

TRANSFER SWITCH

5KVA TRANSFORMER

PANEL B

A5

GATEHOUSE ENTRANCE LEVEL EL. 517.50'

SCALE: 3/8" = 1'-0"

D1

GATEHOUSE UPPER LEVEL EL. 530.50'

SCALE: 3/8" = 1'-0"

A1

GATEHOUSE LOWER LEVEL EL. 507.67'

SCALE: 3/8" = 1'-0"

D5

EXISTING SWITCHBOARD ELEVATION

SCALE: NOT TO SCALE

N

4'0 2' 8'

N

4'0 2' 8'

N

4'0 2' 8'

DAY TANK

D5

ED102

FLOOR HATCH

FLOOR HATCH

ED103

O P

E R

A T

O R

S

Q

U A

R T

E R

S

D

E M

O L I T

I O

N

P

L A

N

D

N

G U

Y E

N

D

N

G U

Y E

N

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

A U

G U

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

E2

NORTH FACE ELEVATION

SCALE: 1/2" = 1'-0"

GENERAL NOTES:

1. DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EXACT

LOCATIONS OR DIMENSIONS. CONTRACTOR IS TO VERIFY LOCATIONS AND

DIMENSIONS IN THE FIELD.

KEY NOTES:

COORDINATE WITH UTILITY CO TO DEMOLISH METER, WIRE, AND CONDUIT

BACK TO THE UTILITY POLE. DEMOLISH WIRE BETWEEN METER AND HOUSE

PANEL. FILL AND SEAL WALL PENETRATION TO MATCH EXISTING FINISH.

DEMOLISH AND REPLACE HOUSE PANEL IN SITU, SEE SHEET E-103.

DEMOLISH PUMP PANEL, DISCONNECT SWITCH, AND ASSOCIATED

CONDUCTORS BACK TO SOURCE PANEL PP. RETAIN CONDUIT FOR REUSE.

REMOVE SWITCH AND RETAIN FOR RELOCATION PER SHEET E-103.

DEMOLISH WALL-MOUNTED SHELVING.

DEMOLISH 240V RECEPTACLE AND WIRE BACK TO SOURCE. RECEPTACLE IS

LOCATED DIRECTLY BENEATH THE EXISTING HOUSE PANEL.

DISCONNECT, INSULATE, AND ABANDON WIRE IN PLACE.

LABEL "TO FORMER 240V RECEPTACLE IN KITCHEN".

HOUSE PANEL

A1

OPERATORS QUARTERS BASEMENT FLOOR PLAN

SCALE: 3/8" = 1'-0"

NORMAL

LOCATION: BASEMENT, NORTH WALL

CKT# AMPS POLES DESCRIPTION

CKT# AMPS POLES DESCRIPTION

HOUSE PANEL

100A MCB

15 1

120/240V 1-PHASE 3-WIRE

REMARKS:SERVICE ENTRANCE PANEL

NOT LABELED

HALL LIGHT SWITCH BY PHONE

WASHER

20 1

PLUGMOLD

BATHROOM HEATER

FED FROM: UTILITY METER

GENERAL ELECTRIC

20 1

120 NOT LABELED

NOT LABELED

15 1

NEAR WASHER KITCHEN COLD REFRI

NOT LABELED

DINING RM LIGHTS & CLOCK

SPACE

SPACE

SPACE

RANGE50 230 2 DRYER

SPACE

SPACE

SPACE

A7

EXISTING HOUSE PANEL SCHEDULE

SCALE: NOT TO SCALE

N

4'0 2' 8'

0 2' 4'1'

E

E D

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

ED602

E L E

C T

R I C

A L

O N

E

L I N

E

D

I A

G R

A M

D E

M O

L I T

I O

N

B

H

E A

D

B

H

E A

D

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

N T

S

A U

G U

A1

ONE LINE DIAGRAM DEMOLITION

SCALE: NOT TO SCALE

KEY NOTES:

CONTRACTOR SHALL HIRE UTILITY TO DEMOLISH EXISTING POLE MOUNTED

OPEN DELTA TRANSFORMERS AND METER SOCKET.

CONTRACTOR SHALL HIRE UTILITY TO DEMOLISH EXISTING UTILITY SERVICE

INCLUDING BUT NOT LIMITED TO METER, METER SOCKET, TRANSFORMER,

DEDICATED CONDUCTORS, AND DEDICATED POLES.

DEMOLISH PANELBOARD AND ASSOCIATED CONDUIT AND WIRE BACK TO

UTILITY METER.

RETAIN FEEDER FOR REUSE.

DEMOLISH SWITCHBOARD AND ASSOCIATED CONDUIT AND WIRE BACK TO

GENERATOR. RETAIN FEEDER NORMAL POWER SOURCE. DEMOLISH

GENERATOR BACK FEED CONDUCTORS RUNNING BACK TO THE MAIN

SWITCHBOARD AT THE UTILITY POLE. RETAIN TRANSFORMER MOUNTED

WITHIN SWITCHBOARD AND DEMOLISH ASSOCIATED CONDUIT AND WIRE.

DEMOLISH HYDRAULIC PUMP MOTORS AND ASSOCIATED STARTER, CONDUIT

AND WIRE BACK TO SOURCE.

RETAIN LOAD AND ASSOCIATED BRANCH CIRCUIT FOR CONNECTION TO NEW

ELECTRICAL EQUIPMENT INSTALLED PER SHEET E-602.

RETAIN PANEL B AND ASSOCIATED FEEDER FOR CONNECTION TO NEW

ELECTRICAL EQUIPMENT.

DEMOLISH WELL CONTROL PANEL. RETAIN FEEDER AND BRANCH CIRCUITS

FOR CONNECTION TO NEW PANEL.

DEMOLISH HOUSE PANEL. RETAIN FEEDER AND BRANCH CIRCUITS FOR

CONNECTION TO NEW PANEL.

DEMOLISH BURIED FEEDER FROM PANEL DEMOLISHED PER KEYED NOTE 3 TO

EXISTING TRANSFORMER.

66 7

GENERAL NOTES:

1. CONDUIT LENGTHS SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED BY

THE CONTRACTOR IN THE FIELD.

2. KEY NOTES GIVE A GENERAL OVERVIEW OF THE WORK RELATIVE TO THE FULL

ELECTRICAL SYSTEM. SEE PLAN VIEWS FOR DETAILED DEMOLITION NOTES.

AutoCAD SHX Text

MDP

AutoCAD SHX Text

PANEL PP

AutoCAD SHX Text

WELL CNTRL PNL

AutoCAD SHX Text

HOUSE PANEL

AutoCAD SHX Text

GENSET

AutoCAD SHX Text

PANEL A

AutoCAD SHX Text

PANEL B

AutoCAD SHX Text

MTS

AutoCAD SHX Text

HDP-1

AutoCAD SHX Text

15 HP

AutoCAD SHX Text Induction

AutoCAD SHX Text 16.7%

AutoCAD SHX Text

HDP-2

AutoCAD SHX Text

15 HP

AutoCAD SHX Text Induction

AutoCAD SHX Text 16.7%

AutoCAD SHX Text

SUMP PUMP

AutoCAD SHX Text

5 HP

AutoCAD SHX Text Induction

AutoCAD SHX Text 16.7%

AutoCAD SHX Text

CRANE

AutoCAD SHX Text

20 HP

AutoCAD SHX Text Induction

AutoCAD SHX Text 16.7%

AutoCAD SHX Text

GEN-1

AutoCAD SHX Text 78 kVA

AutoCAD SHX Text 9%

AutoCAD SHX Text 15%

AutoCAD SHX Text 20%

AutoCAD SHX Text

UTILITY-1

AutoCAD SHX Text

UTILITY-2

AutoCAD SHX Text

UTILITY-TX

AutoCAD SHX Text 50 kVA

AutoCAD SHX Text

13.8 - 0.48 kV

AutoCAD SHX Text 1.5%

AutoCAD SHX Text

P.O. XFMR

AutoCAD SHX Text 75 kVA

AutoCAD SHX Text

0.48 - 0.208 kV

AutoCAD SHX Text 4.8%

AutoCAD SHX Text

UTILITY-TX2

AutoCAD SHX Text 30 kVA

AutoCAD SHX Text

13.8 - 0.208 kV

AutoCAD SHX Text 1.7%

AutoCAD SHX Text

G.H. XFMR

AutoCAD SHX Text 5 kVA

AutoCAD SHX Text

0.48 - 0.208 kV

AutoCAD SHX Text 1.5%

AutoCAD SHX Text

1-1/C-3/0 AWG

AutoCAD SHX Text CU, 55', [Conduit]

AutoCAD SHX Text

1-1/C-1/0 AWG

AutoCAD SHX Text CU, 1180', [Conduit]

AutoCAD SHX Text

1-1/C-3/0 AWG

AutoCAD SHX Text CU, 70', [Conduit]

AutoCAD SHX Text 1-1/C-250 kcmil

AutoCAD SHX Text CU, 30', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 120', [Conduit]

AutoCAD SHX Text 1-1/C-350 kcmil

AutoCAD SHX Text CU, 100', [Conduit]

AutoCAD SHX Text

1-1/C-1/0 AWG

AutoCAD SHX Text CU, 65', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 40', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 40', [Conduit]

AutoCAD SHX Text

1-1/C-12 AWG

AutoCAD SHX Text CU, 200', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 65', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 10', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 30', [Conduit]

AutoCAD SHX Text

GE SGH

AutoCAD SHX Text 600/150

AutoCAD SHX Text

GE THFK

AutoCAD SHX Text 225/225

AutoCAD SHX Text

GE SGH

AutoCAD SHX Text 600/200

AutoCAD SHX Text

SQD

AutoCAD SHX Text

SQD

AutoCAD SHX Text Siemens FXD6

AutoCAD SHX Text 250/100

AutoCAD SHX Text Siemens FXD6

AutoCAD SHX Text 250/100

AutoCAD SHX Text Siemens ED4

AutoCAD SHX Text 125/40

AutoCAD SHX Text Siemens ED4

AutoCAD SHX Text 125/40

AutoCAD SHX Text Siemens ED4

AutoCAD SHX Text 125/20

AutoCAD SHX Text Siemens ED4

AutoCAD SHX Text 125/70

AutoCAD SHX Text Siemens ED4

125/15

GATEHOUSE

E

R

V

I

B

I

D

G

E

HH#3

HH#2

HH#1

PARKING

AREA

S P

I L L W

A Y

S P

IL

L W

A Y

B R

ID

G

E

H

I

A

D

H

I

A

D

D

R

I

V

E

W

A

Y

PARKING LOT

LOCATION OF EXISTING

GENERATOR TO BE RELOCATED

OPERATORS

QUARTERS

PROJECT

OFFICE

OPERATORS

QUARTERS

PARKING

LOT

PROJECT

OFFICE

DRIVEWAY

H

I

A

D

E-101

S I T

E

P

L A

N

N E

W

W

O R

K

D

N

G U

Y E

N

D

N

G U

Y E

N

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

A U

G U

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

GENERAL NOTES:

1. DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EXACT

LOCATIONS OR DISTANCES. CONTRACTOR IS TO VERIFY LOCATIONS

DISTANCES IN THE FIELD.

2. CONDUITS ABOVE GROUND MUST BE GALVANIZED RIGID STEEL. CONDUITS

BELOW GROUND MUST BE SCHEDULE 40 PVC. CONVERSION FROM PVC TO

STEEL MUST OCCUR UNDERGROUND BEFORE DAYLIGHTING.

KEY NOTES:

SEE SHEET E-103 FOR INSTALLATION OF CONCRETE SLAB, GENERATOR, AND

ASSOCIATED EQUIPMENT.

PROVIDE CONDUIT AND WIRE AS INDICATED ON SHEETS E-602 AND E-603 FROM

GENERATOR SET TO ATS.

PROVIDE CONDUIT AND WIRE FROM THE GENERATOR TO THE OPERATORS

QUARTERS. THIS LINE TO PROVIDE 120V POWER FROM THE HOUSE PANEL TO

THE ENGINE BLOCK HEATER AND BATTERY CHARGER.

PROVIDE UTILITY METER PER SHEET E-602. PROVIDE CONDUIT TO INTERFACE

EXISTING UTILITY WIRE AND CONDUIT INTO THE NEW METER.

PROVIDE CONDUIT AND WIRE AS INDICATED ON E-600 SHEETS FROM UTILITY

METER TO ATS.

PROVIDE CONDUIT AND WIRE AS INDICATED ON E-600 SHEETS FROM PANEL

MDP TO JUNCTION BOX.

PROVIDE A JUNCTION BOX TO BE MOUNTED TO THE POLE. PROVIDE A TAP KIT

IN JUNCTION BOX TO INTERFACE EXISTING CONDUCTORS RUNNING TO THE

GATEHOUSE.

PROVIDE NEW CONDUCTORS IN EXISTING CONDUIT AS INDICATED ON SHEETS

E-602 AND E-603.

REPLACE CIRCUIT BREAKER IN PANEL PP PER SHEET E-603 TO FEED THE NEW

HOUSE PANEL IN THE OPERATORS QUARTERS.

PROVIDE CONDUIT AND WIRE AS INDICATED ON E-600 SHEETS FROM PANEL

MDP TO TRANSFORMER.

PROVIDE CONDUIT AND WIRE BETWEEN THE ATS AND THE GENERATOR TO

INTERFACE THE ATS REMOTE START WITH THE GENERATOR STARTING

CIRCUIT.

PROVIDE NEW GROUND WIRE TO RUN ALONGSIDE EXISTING CONDUCTORS

PER SHEET E-603.

D4

SITE PLAN ENLARGEMENT

SCALE: 3/32" = 1'-0"

A1

NEW SITE PLAN

SCALE: 1/64" = 1'-0"

EXISTING BURIED

CONDUIT

75KVA TRANSFORMER

PANEL PP

D1

UTILITY POLE ELEVATION

SCALE: NOT TO SCALE

TO GATEHOUSE

FROM UTILITY

TO AUTOMATIC TRANSFER SWITCH (ATS)

TO PANEL MDP IN BASEMENT

M

I N

B

E L O

W

F I N

I S

H

G

R A

D E

6" MINIMUM

3/4" CRUSHED STONE

EXISTING BASE

BACKFILL

PROVIDE LANDSCAPING OR SIDEWALK

AS NECESSARY TO MATCH EXISTING

SAND

LOCATOR TAPE

D8

TYPICAL ELECTRICAL TRENCH DETAIL

SCALE: NOT TO SCALE

REFER TO SHEET E-103

FOR WORK IN THIS AREA

N

0 8' 32'16'

0 128'64'32'

E

D

C L A

R I F

I C

A T

I O

N

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

S

UP

DOWN

E-102

G A

T E

H O

U S

E

P

L A

N

N E

W

W

O R

K

D

N

G U

Y E

N

D

N

G U

Y E

N

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

A U

G U

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

A5

GATEHOUSE ENTRANCE LEVEL EL. 517.50'

SCALE: 3/8" = 1'-0"

A1

GATEHOUSE LOWER LEVEL EL. 507.67'

SCALE: 3/8" = 1'-0"

D5

NEW UNISTRUT ELEVATION

SCALE: NOT TO SCALE

GENERAL NOTES:

1. DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EXACT

LOCATIONS OR DIMENSIONS. CONTRACTOR IS TO VERIFY LOCATIONS AND

DIMENSIONS IN THE FIELD.

KEY NOTES:

PROVIDE UNISTRUT FIXTURE SIZED TO ACCOMMODATE EQUIPMENT SHOWN

BELOW. POSITION THE FIXTURE ABOVE OR IN PROXIMITY TO EXISTING STUB

UP CONDUITS. PROVIDE MOUNTING EQUIPMENT NECESSARY.

PROVIDE SERVICE ENTRANCE PANELBOARD AS SPECIFIED IN 26 20 00 AND AS

INDICATED ON SHEET E-603. LABEL "PANEL A". PROVIDE ASSOCIATED SURGE

PROTECTIVE DEVICE AS SPECIFIED IN 26 20 00.

INSTALL EXISTING 5KVA TRANSFORMER ONTO THE UNISTRUT FIXTURE.

PROVIDE WIRE AND CONDUIT TO CONNECT TO PANEL A BRANCH CIRCUIT AND

LINE SIDE OF DISCONNECT SWITCH.

PROVIDE ENCLOSED CIRCUIT BREAKER AS INDICATED ON SHEET E-602.

CONNECT EXISTING PANEL B FEEDERS TO LOAD SIDE OF SWITCH.

PROVIDE HYDRAULIC PUMP MOTORS PER SPEC 26 20 00. PROVIDE

CONNECTIONS TO EXISTING ELECTRICAL CIRCUIT.

PROVIDE MATCHING SHEET METAL TO COVER VOID LEFT BY GENERATOR

DUCT REMOVAL.

PROVIDE COMBINATION STARTER/DISCONNECT AS SPECIFIED IN 26 20 00.

PROVIDE CONDUIT AND WIRE BACK TO SOURCE AND TO HYDRAULIC PUMP

MOTORS. DO NOT EXCEED DRILLING DEPTH OF 3" INTO CONCRETE WALL.

D1

GATEHOUSE UPPER LEVEL EL. 530.50'

SCALE: 3/8" = 1'-0"

PANEL B

EXISTING CONDUITS

N

4'0 2' 8'

N

4'0 2' 8'

N

4'0 2' 8'

D5

E-102

FLOOR HATCH

#4 @ 8" O.C. EA WAY

TOP AND BOTTOM, TYP.

4" THICK CAPILLARY

WATER BARRIER

GRADE/PAVEMENT

EDGE OF EQUIPMENT

SEE EQUIP SHOP DWGS

FOR EQUIP ANCHOR

BOLT SIZE AND SPACING

2 - #4 EACH FACE (TYP.)

VAPOR BARRIER

E-103

O P

E R

A T

O R

S

Q

U A

R T

E R

S

P

L A

N

N E

W

W

O R

K

D

N

G U

Y E

N

D

N

G U

Y E

N

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

A U

G U

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

A1

OPERATORS QUARTERS BASEMENT FLOOR PLAN

SCALE: 3/8" = 1'-0"

GENERAL NOTES:

1. DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EXACT

LOCATIONS OR DIMENSIONS. CONTRACTOR IS TO VERIFY LOCATIONS AND

DIMENSIONS IN THE FIELD.

2. PULL BOXES MUST BE PROVIDED ALONG CONDUIT ROUTES AS REQUIRED

SUCH THAT NO MORE THAN (4) 90 DEGREE BENDS OCCUR BETWEEN PULL

BOXES OR DEVICES. PULL BOXES MUST BE SIZED IN ACCORDANCE WITH THE

NATIONAL ELECTRICAL CODE ARTICLE 314.

3. SIDEWALK MUST BE REPAIRED TO MATCH EXISTING.

KEY NOTES:

PROVIDE CONCRETE SLAB PER SPECIFICATION 03 30 53 SIZED TO FIT THE

SUBBASE FUEL TANK. PROVIDE A SUBBASE FUEL TANK AND ENCLOSURE PER

SPECIFICATION 26 32 14. INSTALL THE GENERATOR ASSEMBLY RELOCATED

FROM THE GATEHOUSE. INSTALL BATTERY CHARGER RELOCATED FROM THE

GATEHOUSE. PROVIDE NECESSARY EQUIPMENT TO ENSURE A COMPLETE AND

SECURE INSTALLATION.

PROVIDE SERVICE ENTRANCE RATED FUSED DISCONNECT SWITCH. PROVIDE

WIRE AND CONDUIT FROM DISCONNECT TO WALL PENETRATION AND

INTERFACE WITH INCOMING POWER FEEDERS AND EXISTING CONDUIT FROM

PANEL PP IN PROJECT OFFICE.

REPLACE HOUSE PANEL IN SITU PER SPECIFICATION 26 20 00 AND E-600

SHEETS. PROVIDE WIRE AND CONDUIT TO SERVICE ENTRANCE DISCONNECT

SWITCH TO RUN ABOVE NEW ATS AND PANEL MDP. PROVIDE CONDUIT AND

WIRE OUT TO EXISTING LOADS. PROVIDE WIRE AND CONDUIT OUT TO LOADS

PREVIOUSLY FED FROM PUMP PANEL DEMOLISHED PER SHEET ED103 KEYED

NOTE 1.

PROVIDE WIRE AND CONDUIT FROM HOUSE PANEL TO THE GENERATOR

BLOCK HEATER AND BATTERY CHARGER. SEE PANEL SCHEDULE SHEET E-603.

PROVIDE CORE DRILLING AND TRENCHING AS REQUIRED.

PROVIDE HANDHOLE PER SPECIFICATION 26 20 00.

PROVIDE SERVICE ENTRANCE ATS PER SHEET E-602.

PROVIDE WIRE AND CONDUIT BETWEEN ATS AND UTILITY METER. PROVIDE

WALL PENETRATION.

PROVIDE WIRE AND CONDUIT BETWEEN THE ATS AND GENERATOR POWER.

PROVIDE WALL PENETRATION.

PROVIDE WIRE AND CONDUIT BETWEEN THE ATS AND THE GENERATOR TO

INTERFACE THE ATS REMOTE START WITH THE GENERATOR STARTING

CIRCUIT.

PROVIDE PANELBOARD AS SPECIFIED IN 26 20 00 AND AS INDICATED ON SHEET

E-603. LABEL "MDP". PROVIDE ASSOCIATED SURGE PROTECTIVE DEVICE AS

SPECIFIED IN 26 20 00.

PROVIDE WIRE AND CONDUIT BETWEEN PANEL MDP AND THE JUNCTION BOX

MOUNTED ON THE UTILITY POLE. PROVIDE WALL PENETRATION.

PROVIDE WIRE AND CONDUIT BETWEEN PANEL MDP AND 75KVA PAD-MOUNTED

TRANSFORMER. PROVIDE WALL PENETRATION.

INSTALL SWITCH TO BE RELOCATED PER SHEET ED103. PROVIDE WIRE AND

CONDUIT AS NECESSARY.

HOUSE PANEL

CONCRETE NOTES:

1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS

OF THE AMERICAN CONCRETE INSTITUTE (ACI) "SPECIFICATIONS FOR STRUCTURAL

CONCRETE" (ACI 301)

2. CAST-IN-PLACE CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM 28-day

COMPRESSIVE STRENGTH (f'c):

ALL CONCRETE 4000 PSI

3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT UNLESS SPECIFICALLY OTHERWISE

NOTED.

4. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM

A615/A615M, GRADE 60 UNLESS OTHERWISE NOTED.

5. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE

INDICATED. CONTINUOUS REINFORCING STEEL SHALL BE LAPPED IN ACCORDANCE

WITH THE REQUIREMENTS OF ACI 318.

6. MINIMUM CONCRETE COVER (INCHES) FOR REINFORCING STEEL SHALL BE AS INDICATED.

IN NO CASE SHALL REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF

ACI 301.

A. CONCRETE DEPOSITED AGAINST THE GROUND 3

B. CONCRETE EXPOSED TO EARTH OR WEATHER 2

C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:

i. BEAMS AND COLUMNS 1.5

ii. SLABS AND WALLS 0.75

7. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A

90-DEGREE HOOK UNLESS OTHERWISE NOTED. STIRRUP, TIES AND 180-DEGREE

HOOKS AND 90-DEGREE HOOKS SHALL CONFORM TO THE REQUIREMENTS OF ACI

318.

8. PROVIDE 0.5 INCH THICK JOINT FILLER MATERIAL WHERE SLABS ON GRADE ABUT

VERTICAL SURFACES.

9. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED, AND

MAINTAINED SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.

10. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, TIEBACKS RECESSES AND

OTHER EMBEDDED ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL

NOT BE CUT TO FACILITATE PLACEMENT OF EMBEDDED ITEMS.

11. NO CONCRETE SHALL BE PLACED UNTIL THE CONTRACTING OFFICER OR THE

CONTRACTING OFFICER'S DESIGNATED REPRESENTATIVE HAS INSPECTED ALL

EMBEDDED WORK, INCLUDING REINFORCEMENT.

12. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 0.75 INCHES OR AS INDICATED.

13. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS

EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION

AND ELECTROLYTIC ACTION BETWEEN ALUMINUM AND STEEL.

14. WHEN A SPECIFIED REINFORCING BAR IS NOT AVAILABLE, THE NEXT LARGER

(DIAMETER) SIZE BAR MAY BE SUBSTITUTED.

15. TOP SURFACE OF PAD TO BE LEVEL.

COORD BASE SIZE WITH ACTUAL EQUIPMENT REQUIREMENTS

0'-8" 0'-4"

M

I N

C O

O R

D

W

E

Q U

I P

M

I N

6" MIN

F5

TYPICAL EQUIPMENT SLAB DETAIL

SCALE: NOT TO SCALE

WATER PIPE 83" AFF

WATER PIPE

85" AFF

MOUNT ALONG CEILING

EXISTING BURIED CONDUIT

REFER TO SHEET E-101 FOR

CONTINUATION OF WORK

4'0 2' 8'

N

M

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

E-602

E L E

C T

R I C

A L

O N

E

L I N

E

D

I A

G R

A M

I N

S T

A L L A

T I O

N

B

H

E A

D

B

H

E A

D

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

N T

S

A U

G U

A1

ONE LINE DIAGRAM INSTALLATION

SCALE: NOT TO SCALE

16 16 17 17

KEY NOTES:

CONTRACTOR SHALL HIRE UTILITY TO INSTALL POLE MOUNTED 75 KVA

TRANSFORMER BANK WITH A GROUNDED WYE 480/277V SECONDARY. UTILITY

SHALL PROVIDE CONDUCTORS FROM TRANSFORMER TO METER SOCKET

INSTALLED PER KEYED NOTE 2. UTILITY SHALL PROVIDE METER AND

TERMINATIONS ON THE LINE SIDE OF THE METER SOCKET.

PROVIDE METER SOCKET AS SPECIFIED IN 26 20 00.

RELOCATE GENERATOR SET AS INDICATED ON SHEETS ED101 AND E-101.

PROVIDE FOUNDATION, CONCRETE PAD, ANCHORS, ETC AS REQUIRED TO

MAKE THE INSTALLATION COMPLETE. PROVIDE WEATHERPROOF SOUND

ATTENUATING ENCLOSURE AS SPECIFIED IN 26 32 14.

PROVIDE BURIED FEEDER PER TRENCHING DETAIL ON SHEET E-101 BETWEEN

GENERATOR SET AND AUTOMATIC TRANSFER SWITCH (ATS).

PROVIDE BURIED FEEDER PER TRENCHING DETAIL ON SHEET E-101 BETWEEN

METER SOCKET INSTALLED PER KEYED NOTE 2 AND AUTOMATIC TRANSFER

SWITCH (ATS).

PROVIDE AUTOMATIC TRANSFER SWITCH (ATS) AS SPECIFIED IN 26 20 00.

PROVIDE CONDUIT AND WIRE FROM THE LOAD SIDE TO THE PANELBOARD

INSTALLED PER KEYED NOTE 7.

PROVIDE PANELBOARD MDP AS SPECIFIED IN 26 20 00. PROVIDE ASSOCIATED

SURGE PROTECTIVE DEVICE AS SPECIFIED IN 26 20 00.

NOT USED.

NOT USED.

PROVIDE BURIED FEEDER PER TRENCHING DETAIL ON SHEET E-101 BETWEEN

PANELBOARD INSTALLED PER KEYED NOTE 7 AND JUNCTION BOX INSTALLED

PER KEYED NOTE 11.

PROVIDE JUNCTION BOX AND SPLICE KIT PER SPECIFICATION 26 20 00. SPLICE

CONDUCTORS INSTALLED PER KEYED NOTE 10 TO CONDUCTORS RETAINED

PER KEYED NOTE 4 SHEET ED602.

PROVIDE PANELBOARD PER SPECIFICATION 26 20 00. PROVIDE CONDUIT AND

WIRE AS REQUIRED TO RESTORE POWER TO BRANCH CIRCUITS. PROVIDE

ASSOCIATED SURGE PROTECTIVE DEVICE AS SPECIFIED IN 26 20 00.

TERMINATE FEEDER RETAINED PER SHEET ED602 KEYED NOTE 4 ON THE LINE

SIDE OF THE MAIN BREAKER.

INSTALL TRANSFORMER RETAINED PER SHEET ED602 AND PROVIDE CONDUIT

AND WIRE BACK TO PANEL-A. SEE SHEET E-102.

PROVIDE ENCLOSED CIRCUIT BREAKER PER SPECIFICATION 26 20 00.

PROVIDE CONDUIT AND WIRE BACK TO TRANSFORMER INSTALLED PER KEYED

NOTE 13. TERMINATE PANEL-B FEEDER RETAINED PER SHEET ED602 KEYED

NOTE 8 ON THE LOAD SIDE OF THE BREAKER. PROVIDE CONDUIT AND WIRE

AS REQUIRED.

PROVIDE NON-FUSED COMBINATION STARTER/DISCONNECT PER

SPECIFICATION 26 20 00. PROVIDE CONDUIT AND WIRE BACK TO SOURCE AND

OUT TO MOTOR INSTALLED PER KEYED NOTE 16.

PROVIDE MOTOR AS SPECIFIED IN 26 20 00.

TERMINATE EXISTING BRANCH CIRCUITS RETAINED PER SHEET ED602 KEYED

NOTE 7 IN NEW PANEL A. SEE PANEL SCHEDULE, SHEET E-603. PROVIDE

CONDUIT AS REQUIRED.

PROVIDE CONDUIT AND WIRE FROM PANELBOARD MDP INSTALLED PER

KEYED NOTE 7 TO EXISTING TRANSFORMER.

PROVIDE CIRCUIT BREAKER IN EXISTING PANELBOARD. SEE PANEL SCHEDULE

SHEET E-603.

PROVIDE PANELBOARD PER SPECIFICATION 26 20 00. PROVIDE CONDUIT AND

WIRE AS REQUIRED TO RESTORE POWER TO BRANCH CIRCUITS. PROVIDE

BURIED FEEDER BACK TO SOURCE. SEE TRENCHING DETAIL SHEET E-101.

GENERAL NOTES:

1. CONDUIT LENGTHS SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED BY

THE CONTRACTOR IN THE FIELD.

2. KEY NOTES GIVE GENERAL OVERVIEWS OF THE WORK RELATIVE TO THE FULL

ELECTRICAL SYSTEM AND PROVIDE REFERENCES TO RELEVANT

SPECIFICATIONS. SEE PLAN VIEWS FOR DETAILED INSTALLATION NOTES.

AutoCAD SHX Text

UTILITY

AutoCAD SHX Text

UTILITY SEC

AutoCAD SHX Text

PANEL PP

AutoCAD SHX Text

HOUSE PANEL S.E.

AutoCAD SHX Text

GENSET

AutoCAD SHX Text

PANEL A

AutoCAD SHX Text

HDP-1

AutoCAD SHX Text

HDP-2

AutoCAD SHX Text

SUMP PUMP

AutoCAD SHX Text

CRANE

AutoCAD SHX Text

PANEL B

AutoCAD SHX Text

PANEL MDP

AutoCAD SHX Text

HOUSE PANEL

AutoCAD SHX Text

ATS

AutoCAD SHX Text

HDP-1

AutoCAD SHX Text

15 HP

AutoCAD SHX Text Induction

AutoCAD SHX Text 16.7%

AutoCAD SHX Text

HDP-2

AutoCAD SHX Text

15 HP

AutoCAD SHX Text Induction

AutoCAD SHX Text 16.7%

AutoCAD SHX Text

SUMP PUMP

AutoCAD SHX Text

5 HP

AutoCAD SHX Text Induction

AutoCAD SHX Text 16.7%

AutoCAD SHX Text

CRANE

AutoCAD SHX Text

20 HP

AutoCAD SHX Text Induction

AutoCAD SHX Text 16.7%

AutoCAD SHX Text

GEN-1

AutoCAD SHX Text 78 kVA

AutoCAD SHX Text 9%

AutoCAD SHX Text 15%

AutoCAD SHX Text 20%

AutoCAD SHX Text

UTILITY

AutoCAD SHX Text

UTILITY-TX

AutoCAD SHX Text 75 kVA

AutoCAD SHX Text

13.8 - 0.48 kV

AutoCAD SHX Text 1.5%

AutoCAD SHX Text

P.O. XFMR

AutoCAD SHX Text 75 kVA

AutoCAD SHX Text

0.48 - 0.208 kV

AutoCAD SHX Text 4.8%

AutoCAD SHX Text

G.H. XFMR

AutoCAD SHX Text 5 kVA

AutoCAD SHX Text

0.48 - 0.208 kV

AutoCAD SHX Text 1.5%

AutoCAD SHX Text

1-1/C-1/0 AWG

AutoCAD SHX Text CU, 125', [Conduit]

AutoCAD SHX Text

1-1/C-1/0 AWG

AutoCAD SHX Text CU, 1180', [Conduit]

AutoCAD SHX Text 1-1/C-250 kcmil

AutoCAD SHX Text CU, 30', [Conduit]

AutoCAD SHX Text

1-1/C-1 AWG

AutoCAD SHX Text CU, 45', [Conduit]

AutoCAD SHX Text

1-1/C-1 AWG

AutoCAD SHX Text CU, 100', [Conduit]

AutoCAD SHX Text

1-1/C-1 AWG

AutoCAD SHX Text CU, 75', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 40', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 40', [Conduit]

AutoCAD SHX Text

1-1/C-12 AWG

AutoCAD SHX Text CU, 200', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 65', [Conduit]

AutoCAD SHX Text

1-1/C-10 AWG

AutoCAD SHX Text CU, 10', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 10', [Conduit]

AutoCAD SHX Text

1-1/C-1 AWG

AutoCAD SHX Text CU, 10', [Conduit]

AutoCAD SHX Text

1-1/C-1 AWG

AutoCAD SHX Text CU, 85', [Conduit]

AutoCAD SHX Text

1-1/C-8 AWG

AutoCAD SHX Text CU, 30', [Conduit]

AutoCAD SHX Text

SQD KA

AutoCAD SHX Text 250/100

AutoCAD SHX Text

SQD KA

AutoCAD SHX Text 250/100

AutoCAD SHX Text

SQD

AutoCAD SHX Text

SQD QB

AutoCAD SHX Text 250/225

AutoCAD SHX Text ABB Ts3N-150

AutoCAD SHX Text 150/100

AutoCAD SHX Text ABB Ts3N-150

AutoCAD SHX Text 150/100

AutoCAD SHX Text

SQD HD

AutoCAD SHX Text 150/100

AutoCAD SHX Text

SQD HD

AutoCAD SHX Text 150/40

AutoCAD SHX Text

SQD HD

AutoCAD SHX Text 150/40

AutoCAD SHX Text

SQD HD

AutoCAD SHX Text 150/20

AutoCAD SHX Text

SQD KA

AutoCAD SHX Text 250/70

AutoCAD SHX Text

SQD HD

AutoCAD SHX Text 150/25

AutoCAD SHX Text

SQD KA

AutoCAD SHX Text 250/100

AutoCAD SHX Text

SQD HD

AutoCAD SHX Text 150/25

AutoCAD SHX Text

SQD QB

AutoCAD SHX Text 250/100

AutoCAD SHX Text Siemens FXD6

AutoCAD SHX Text 250/125

AutoCAD SHX Text

BUSS FRN-R(RK-5)

100A

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

O F

F Y

E

L E

C T

R I C

A L

E

Q U

I P

M E

G

R A

D E

T H

O M

A S

T O

N

D

A M

T H

O M

A S

T O

N

C

O N

N E

C T

I C

U T

W W

J B

H O

U T

H

E-603

E L

E C

T R

I C

A L

P A

N E

E

D E

R

S

C H

E D

U L

E S

I N

S T

A L

L A

T I O

N

B

H

E A

D

B

H

E A

D

J

C

L I N

E

M

J U

R C

I C

A N

S I

D

N T

S

A U

G U

NORMAL

LOCATION: ENTRY LEVEL

CKT# AMPS POLES DESCRIPTION

70 3

20 3

CKT# AMPS POLES DESCRIPTION

PANEL A

100A MCB 18 KAIC

480/277V 3-PHASE 4-WIRE

REMARKS:SERVICE ENTRANCE PANEL

SWITCHGEAR: UTILITY TRANSFORMER

320 SUMP PUMP

CRANE

SURGE PROTECTIVE DEVICE 40

215 PANEL B VIA 5 KVA TRANSFORMER

HDP-1

HDP-2

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

FED FROM: MTS AT PROJECT OFFICE

SQUARE D I-LINE

NORMAL

LOCATION: ENTRY DOOR

CKT# AMPS POLES DESCRIPTION

CKT# AMPS POLES DESCRIPTION

PANEL PP

225A MCB 18 KAIC

20 1

120/208V 3-PHASE 4-WIRE

REMARKS:SERVICE ENTRANCE PANEL

SWITCHGEAR: C.O.E. PAD MOUNTED TRANSFORMER

LIHTS, OFFICE, STOCK ROOM

COMP NETWORK

HALL LIGHTS, BACK LIGHTS

20 1

OFFICE RCPT/WATER SYSTEM PL.

COMFORT STATION MOTION LIGHT

RCPT NORTH END ATTIC

FED FROM: SERVICE ENTRANCE MTS

SQUARE D NQOD

BLANK

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

350 WELDING RCPT

3 HOUSE PANEL

320 WELL 5 VISTA

320 WELL 3 PIT

215 AIR COMPRESSOR RCPT

PREPARE SPACE

20 1

WORKSHOP LIGHTS

RRCPT/ WORKSHOP/MOTION

WORKSHOP LIGHTS

20 1

MICRO FRIDGE

SPARE

OFFICE RCPT

20 1

SPARE

SPARE

SPARE

20 1

BOILER/MOTION LIGHT/RCPTS

UNIT HEATER

SPARE

20 1

RCPT PM OFFICE

NORTH BAY GARAGE DOOR

RCPT PM OFFICE

20 1

SOUTH BAY HEAT FAN

SOUTH BAY GARAGE DOOR

ATTIC LIGHTS

20 1

SPARE

SPARE

SPARE

NORMAL

LOCATION: ENTRY DOOR

CKT# AMPS POLES DESCRIPTION

CKT# AMPS POLES DESCRIPTION

HOUSE PANEL

225A MCB 18 KAIC

15 1

120/208V 3-PHASE 4-WIRE

REMARKS: SERVICE ENTRANCE PANEL

SWITCHGEAR: C.O.E. PAD MOUNTED TRANSFORMER

NOT LABELED

HALL LIGHT SWITCH BY PHONE

WASHER

20 1

PLUGMOLD

BATHROOM HEATER

FED FROM: SERVICE ENTRANCE MTS

SQUARE D NQOD

20 1

120 NOT LABELED

REFEED FROM PUMP PANEL

NOT LABELED

15 1

NEAR WASHER KITCHEN COLD REFRI

NOT LABELED

DINING RM LIGHTS & CLOCK

REFEED FROM PUMP PANEL

REFEED FROM PUMP PANEL

REFEED FROM PUMP PANEL

REFEED FROM PUMP PANEL

REFEED FROM PUMP PANEL

SPARE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

20 1

REFEED FROM PUMP PANEL

REFEED FROM PUMP PANEL

SPARE120

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

NOTE:

1. CKT #11-18: LOAD IS REFED FROM PUMP PANEL. INSTALL NEW CIRCUIT BREAKERS TO MIMIC AMP RATINGS, POLES, AND CONFIGURATION OF EXISTING

PUMP PANEL. LABEL NEW PANEL SCHEDULE TO CORRESPOND TO PUMP PANEL CIRCUITS.

NOTE 1

NOTE 1

NOTE 1

NOTE 1

NOTE 1

CONDUIT AND CABLE SCHEDULE

VOLTAGE NUMBER

OF

CONDUCTORS

WIRE

SIZE

(AWG)

GROUND

SIZE

(AWG)

CONDUIT

SIZE -TYPE

APPROX.

LENGTH

CONDUIT AND CABLE SCHEDULE NOTES

SOURCE LOAD

1.5"-PVC

GENERATOR SET

75'

480/277V

10'

480/277V EXISTING

480V 8 0.75"-RGS

3 6 150'

PANELBOARD MDP PROJECT OFFICE TRANSFORMER

480V 1 1.5"-PVC

UTILITY METER SOCKET AUTOMATIC TRANSFER SWITCH (ATS)

480/277V 1/0 6

125'

SEE NOTE 3

AUTOMATIC TRANSFER SWITCH (ATS) PANELBOARD MDP

PANELBOARD MDP JUNCTION BOX

JUNCTION BOX

PANEL A

PANEL A

HDP-1

480/277V

480/277V

480V

1/0 1.5"-PVC

1.5"-RGS

1/0 1.5"-PVC

1/0

40'

1180'

PANEL A

PANEL A

HDP-2

G.H. TRANSFORMER

125'

2 10 10 0.75"-RGS

10'

120/208V 3 8 8 0.75"-RGS

10'

G.H. TRANSFORMER SECONDARY PROTECTIVE DEVICE

3 8120/208V

SECONDARY PROTECTIVE DEVICE

30'

PANEL B

8 0.75"-RGS

1. LENGTH ON THIS SCHEDULE IS APPROXIMATE, CONTRACTOR SHALL CONFIRM LENGTH IN THE FIELD.

2. REFEED CIRCUITS SHOWN ON PANEL SCHEDULE, SEE SHEET E-601.

3. PROVIDE NEW GROUND WIRE TO RUN ALONGSIDE EXISTING CONDUCTORS PER SHEET E-101.

3 108 0.75"-RGS 40'480V

50 WELL CONTROL

PREPARE SPACE PREPARE SPACE

PREPARE SPACE PREPARE SPACE

NOTE 1

NOTE 1 NOTE 1

AUTOMATIC TRANSFER SWITCH (ATS)

NORMAL

LOCATION: BASEMENT

CKT# AMPS POLES DESCRIPTION

CKT# AMPS POLES DESCRIPTION

MDP

225A MLO 18 KAIC

480/277V 3-PHASE 4-WIRE

REMARKS:

SWITCHGEAR: UTILITY TRANSFORMER

3100 PANEL-A GATE TOWER3

FED FROM: SERVICE ENTRANCE ATS

SQUARE D I-LINE

3100 PROJECT OFFICE TRANSFORMER

PREPARE SPACE PREPARE SPACE

PREPARE SPACE PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

PREPARE SPACE

4 8 100'

PANELBOARD PP OPERATOR'S QUARTERS S.E. DISCONNECT

120/208V 1 1.5"-PVC

2 12 45'

AUTOMATIC TRANSFER SWITCH (ATS) GENERATOR SET (STARTING CIRCUIT)

480V 12 0.75"-RGS

4 8

OPERATOR'S QUARTERS S.E. DISCONNECT

HOUSE PANEL

120/208V 45'1.5"-RGS

20 3 SURGE PROTECTIVE DEVICE

C L A

R I F

I C

A T

I O

N

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

S

HOU-TH-120_G-001-ANSI D
HOU-TH-120_E-001-ANSI D
HOU-TH-120_ED101-ANSI D
HOU-TH-120_ED102-ANSI D
HOU-TH-120_ED103-ANSI D
HOU-TH-120_ED602-ANSI D
HOU-TH-120_E-101-ANSI D
HOU-TH-120_E-102-ANSI D
HOU-TH-120_E-103-ANSI D
HOU-TH-120_E-602-ANSI D
HOU-TH-120_E-603-ANSI D

File details come from the government source that posted it.