W912QR24R0014_Plans-0003.pdf

PDF 9 MB Posted

Attached to
Camp Arifjan Microgrid
Solicitation number
W912QR24R0014
Issued by

About this file

This document is a set of electrical drawings and schematics for a solar PV and battery energy storage system (BESS) project at Camp Arifjan in Kuwait. The project calls for installing a photovoltaic system and BESS on the roofs of two existing warehouse buildings, as well as associated electrical equipment such as inverters, switchgear, transformers, and underground conduits. The drawings provide detailed plans for the solar array layout, electrical interconnections, and telecommunications/control systems. Key details include the total solar PV capacity of 3,168 panels, a 1,000 kW/2,000 kWh BESS, and a 2,500 kVA step-up transformer. The project is part of a larger solicitation for a new microgrid system at Camp Arifjan, which is being procured by the U.S. Army Corps of Engineers.

View the file

Other files

File Type Posted
W912QR24R0014-0004.pdf PDF
W912QR24R0014_Specs-0003.pdf PDF
Site visit sign in sheet.pdf PDF
Site visit pics_.pdf PDF
W912QR24R0014-0002.pdf PDF
W912QR24R0014-0001.pdf PDF
W912QR24R0014_Plans-0000.pdf PDF
W912QR24R0014_Specs-0000.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

IS

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A R

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-100

E L

E C

T R

IC

A

L S

IT

E

P L

A N

O V

E R

A L

L

N .T

.S

N B4101

SS4101

B2350

B2351

T2091

T516 513

T

T

B4003 B4004

B4001 B4002

T-572

T550

T-788 B4112 T-780

AREA

TIP-C

T

T345

MCF

DPW

MH-01

MH-02

MH-03

MH-04

MH-05

MH-06

MH-07

MH-08

MH-12

MH-11

MH-10

MH-13 MH-14 MH-15

MH-16

MH-18

MH-19

MH-20MH-21MH-22

GENERAL NOTES

BUILDING.

BESS SHALL BE MIN 100 FT AWAY FROM ANY OCCUPIED 15.

AROUND LIGHTING PROTECTON SYSTEM.

CENTERLINE OF THE ROOF. CONTRACTOR SHALL WORK

TERMINALS ARE PLACED ALONG THE EDGE AND

PROTECTION SYSTEM INSTALLED ON THE ROOF. AIR

BOTH WAREHOUSE BUILDINGS HAVE A LIGHTNING 14.

INSTALLED ON CONCRETE PADS.

EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 13.

TYPE USE-2.

CONDUIT AND ARE EXPOSED TO SUNLIGHT WILL BE

FOR WIRES IN CONDUIT. CONDUCTORS NOT IN

600V INSULATION SUITABLE FOR WET & DRY LOCATIONS

WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES C, 12.

SERIES.

PHOTOVOLTAIC STRINGS HAVE 11 SOLAR MODULES IN 11.

SIZES.

REFER TO SINGLE LINE FOR CONDUIT AND CONDUCTOR 10.

FROM DPW AND THROUGH FIELD VERIFICATION.

CONSTRUCTION THROUGH INFORMATION OBTAINED

CONTRACTOR MUST LOCATE UTILITIES PRIOR TO

LOCATIONS OF ADDITIONAL UTILITIES ARE UNKNOWN,

UTILITIES SHOWN ON DRAWING ARE ESTIMATED.

ANY EXISTING UTILITIES. LOCATIONS OF EXISTING

AUTHORITIES (DEPARTMENT PUBLIC WORK) TO AVOID

UNDERGROUND WORK WITH THE APPROPRIATE

CONTRACTOR SHALL COORDINATE AND CONFIRM ALL

VOLTAGE CABLES, AND OTHER UTILITIES IN WORK AREA.

THERE ARE UNDERGROUND WATER LINES, LOW 9.

SPECIFICATIONS.

8.4. RE: AS-BUILT DRAWINGS IN CONTRACT

YIELD STRENGTH. FLANGE THICKNESS IS 8mm.

8.3. EXISTING WIDE FLANGE GIRDERS ARE 250 MPa

AT 7292mm SPACING.

8.2. EXISTING ROOF PURLINS ARE COLD FORM 200Z20

STRENGTH OF 345 MPa.

KIRBY ROOF, 0.6mm THICK STEEL PANELS. YIELD

8.1. EXISTING ROOF PANEL ARE KR-0.6 TYPE 6860,

CONTRACTOR MUST VERIFY EXISTING ROOF ELEMENTS.8.

ARE IDENTICAL FOR BOTH WAREHOUSES.

CAMP ARIFJAN. THE GENERAL LAYOUT AND EQUIPMENT

EQUIPMENT ON THE ROOF OF TWO WAREHOUSES AT

THIS PROJECT CALLS FOR INSTALLING PHOTOVOLTAIC 7.

BRITISH STANDARD 7671.

ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH

DESIGNED IN ACCORDANCE WITH NEC 2020. ALL OTHER

ELECTRICAL INTERCONNECTION WORK HAS BEEN 6.

FUTURE USE. CAP ENDS OF ALL UNUSED CONDUITS.

PLACE PULL CORD IN SPARE UNUSED CONDUITS FOR 5.

BOXES WITH STAINLESS STEEL CABLE TAGS.

IDENTIFY AND LABEL ALL CABLES IN MANHOLES & PULL 4.

ENCASED.

METERS OF ROADWAY EDGE SHALL BE CONCRETE

ROADS, DRIVEWAYS, PARKING AREAS, AND WITHIN 2

PORTIONS OF THE DUCTBANK CROSSING UNDER

CONDUITS WILL BE DIRECT BURIED EXCEPT FOR 3.

2 METERS ALONG ENTIRE ROUTE OF DUCTBANK.

CONTRACTOR SHALL PLACE CONDUIT SPACERS EVERY 2.

SCHEDULE 80 PVC.

UNDERGROUND CONDUITS ARE SIZED 103mm 1.

E-101

SHEET

E-102

SHEET

E-104

SHEET

E-107

SHEET

E-104

SHEET

E-103

SHEET

E-105

SHEET

E-106

SHEET

STATION WEST

SWITCHING

SWITCHGEAR

MOUNTED

EXISTING PAD

LOCATION

TIP-C SWITCHGEAR

PROPOSED

INVERTERS

PV

BESS

LOCATION

PROPOSED UDS

MH-17

ARRAYS

SOLAR

SITE PLAN

OVERALL ELECTRICAL

STREET CROSSING(TYP)

IN CONCRETE UNDER

CONDUITS ENCASED

STREET CROSSING(TYP)

IN CONCRETE UNDER

CONDUITS ENCASED

STREET CROSSING(TYP)

IN CONCRETE UNDER

CONDUITS ENCASED

LOCATION

TRANSFORMER

PROPOSED STEP-DOWN

SHEET SYMBOLS:

DRIVEWAYS, PARKING AREAS, ETC. REF. SHEET E-505.

UNDER ROADS,CONDUITS ENCASED IN CONCRETE

VOLTAGE

UNDERGROUND PVC CONDUITS SCH. 80 MEDIUM

UNDERGROUND PVC CONDUITS SCH. 80 LOW VOLTAGE

MANHOLE, MH-##

POWERPLANT

EXISTING

M

M

M

M

M

M

M

M

M

M

+/-138M+/-143M+/-158M

M

M

M

M

+/-159M +/-143M +/-140M

+/-184M

+/-94M

SCALE: NOT TO SCALE

A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

ARIMS: 200A Disposition: Maintain for 15 yrs after construction.

IS

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-101

S

IT

E P

L A

N O

N E

E L

E C

T R

IC

A

L

N .T

.S

N

GENERAL NOTES

21.7kgSOLAR PANEL WEIGHT

(1024 X 2024 X 40)mmSOLAR PANEL DIMENSIONS

10.47ASHORT CIRCUIT CURRENT

49.3VOPEN CIRCUIT VOLTAGE

9.86AMAX POWER CURRENT

40.6VMAX POWER VOLTAGE

400WSTC WATTAGE RATING

3168TOTAL NUMBER OF PANELS

EQUIPMENT RATING:

SOLAR PANEL BASIS OF DESIGN

2B4

2B5

2B6

2B1

2B2

2B3

2A1

2A2

2A3

2A4

2A6

2A5

1A4

1A6

1A5 1B5

1B4

1B6

1B3

1B2

1B11A1

1A2

1A3

B4001 B4002

B2350

MH-01

MH-02

MH-03

CONSTRUCTION

CURRENTLY UNDER

SWITCHGEAR

MOUNTED

EXISTING PAD

STATION WEST

EXISTING SWITCHING

INVERTERS

PV

BESS

STREET CROSSINGS(TYP)

IN CONCRETE UNDER

CONDUITS ENCASED

ARRAYS

SOLAR

E-104

SHEET

E-104

SHEET

E-105

SHEET

E-103

SHEET

SHEET SYMBOLS:

DRIVEWAYS, PARKING AREAS, ETC. REF. SHEET E-505.

UNDER ROADS,CONDUITS ENCASED IN CONCRETE

80 MEDIUM VOLTAGE

UNDERGROUND PVC CONDUITS SCH.

80 LOW VOLTAGE

UNDERGROUND PVC CONDUITS SCH.

MANHOLE, MH-##

BUILDING.

BESS SHALL BE MIN 100 FT AWAY FROM ANY OCCUPIED 14.

AROUND LIGHTING PROTECTON SYSTEM.

CENTERLINE OF THE ROOF. CONTRACTOR SHALL WORK

TERMINALS ARE PLACED ALONG THE EDGE AND

PROTECTION SYSTEM INSTALLED ON THE ROOF. AIR

BOTH WAREHOUSE BUILDINGS HAVE A LIGHTNING 13.

INSTALLED ON CONCRETE PADS.

EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 12.

TYPE USE-2.

CONDUIT AND ARE EXPOSED TO SUNLIGHT WILL BE

FOR WIRES IN CONDUIT. CONDUCTORS NOT IN

600V INSULATION SUITABLE FOR WET & DRY LOCATIONS

WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES C, 11.

SERIES.

PHOTOVOLTAIC STRINGS HAVE 11 SOLAR MODULES IN 10.

SIZES.

REFER TO SINGLE LINE FOR CONDUIT AND CONDUCTOR 9.

DRAWING ARE ESTIMATED.

LOCATIONS OF EXISTING UTILITIES SHOWN ON

AUTHORITIES TO AVOID ANY EXISTING UTILITIES.

UNDERGROUND WORK WITH THE APPROPRIATE

CONTRACTOR SHALL COORDINATE AND CONFIRM ALL

VOLTAGE CABLES, AND OTHER UTILITIES IN WORK AREA.

THERE ARE UNDERGROUND WATER LINES, LOW 8.

ARE IDENTICAL FOR BOTH WAREHOUSES.

CAMP ARIFJAN. THE GENERAL LAYOUT AND EQUIPMENT

EQUIPMENT ON THE ROOF OF TWO WAREHOUSES AT

THIS PROJECT CALLS FOR INSTALLING PHOTOVOLTAIC 7.

BRITISH STANDARD 7671.

ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH

DESIGNED IN ACCORDANCE WITH NEC 2020. ALL OTHER

ELECTRICAL INTERCONNECTION WORK HAS BEEN 6.

FUTURE USE. CAP ENDS OF ALL UNUSED CONDUITS.

PLACE PULL CORD IN SPARE UNUSED CONDUITS FOR 5.

BOXES WITH STAINLESS STEEL CABLE TAGS.

IDENTIFY AND LABEL ALL CABLES IN MANHOLES & PULL 4.

ENCASED.

METERS OF ROADWAY EDGE SHALL BE CONCRETE

ROADS, DRIVEWAYS, PARKING AREAS, AND WITHIN 2

PORTIONS OF THE DUCTBANK CROSSING UNDER

CONDUITS WILL BE DIRECT BURIED EXCEPT FOR 3.

2 METERS ALONG ENTIRE ROUTE OF DUCTBANK.

CONTRACTOR SHALL PLACE CONDUIT SPACERS EVERY 2.

103mm SCHEDULE 80 PVC.

UNDERGROUND ELECTRICAL CONDUITS ARE SIZED 1.

SEE E-503(TYP)

PULLBOX

COMMUNICATIONS

SCALE: NOT TO SCALE

SITE PLAN ONE

ELECTRICAL 1150mm BELOW BOTTOM OF DITCH

SHALL INSTALL ELECTRIC LINE CONDUIT A MINIMUM

EXISTING AGGREGATE LINED DITCH CONTRACTOR

SEE NOTE 15

M

M

M

M

M

A M

E N

D M

E N

T

/0

/0

MH-04

MH-05

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

A M

E N

D M

E N

T

E-102

S

IT

E P

L A

N T

W O

E L

E C

T R

IC

A

L

N .T

.S

N

MH-07

MH-10

MH-11

MH-12

MH-13 MH-14 MH-15

MH-18

MH-19

MH-20

MH-21MH-22

MH-17

STREET CROSSINGS(TYP)

IN CONCRETE UNDER

CONDUITS ENCASED

STREET CROSSINGS(TYP)

IN CONCRETE UNDER

CONDUITS ENCASED

STREET CROSSINGS(TYP)

IN CONCRETE UNDER

CONDUITS ENCASED

LOCATION

MCF UDS

PROPOSED

E-106

SHEET

E-107

SHEET

TRANSFORMER LOCATION

PROPOSED STEP-DOWN

MH-16

SHEET SYMBOLS:

DRIVEWAYS, PARKING AREAS, ETC. REF. SHEET E-505.

UNDER ROADS,CONDUITS ENCASED IN CONCRETE

VOLTAGE

UNDERGROUND PVC CONDUITS SCH. 80 MEDIUM

UNDERGROUND PVC CONDUITS SCH. 80 LOW VOLTAGE

MANHOLE, MH-##

MCF

T780

T786

T788

T787

T784

B4112

SEE E-503(TYP)

PULLBOX

COMMUNICATIONS

LOCATION

SWITCHGEAR

PROPOSED TIP-C

MH-08 MH-06

SEE E-503 (TYP)

PULLBOX

COMMUNICATIONS

SEE E-503 (TYP)

PULLBOX

COMMUNICATIONS

SEE E-503 (TYP)

PULLBOX

COMMUNICATIONS

ELECTRICAL SITE PLAN TWO

SEE ASPHALT PAVING SHEET S-502

CONDUIT AND REPAVE ASPHALT ROAD,

ROAD, INSTALL NEW CONCRETE ENCASED

CONTRACTOR SHALL SAW CUT ASPHALT

SEE ASPHALT PAVING SHEET S-502

CONDUIT AND REPAVE ASPHALT ROAD,

ROAD, INSTALL NEW CONCRETE ENCASED

CONTRACTOR SHALL SAW CUT ASPHALT

+/-184M +/-159M +/-143M +/-140M

M

M

M

M

+/-138M+/-143M+/-158M

M

M

M

M

SCALE: NOT TO SCALE

/0

/0

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-103

S

IT

E P

L A

N P

V E

L E

C T

R

IC

A L

N .T

.S

N

MH-04

MH-05

1A1

1A2 1B2

1B1 2A1 2B1

2B22A2

B4001 B4002

1A3 1B3 2A3 2B3

1A4 1B4 2A4 2B4

1A5 1B5 2A5 2B5

1A6 1B6 2A6 2B6

INVERTERS

PV

BESS

(TYP)

PV ARRAY

E-104

SHEET

E-105

SHEET

E-104

SHEET

SEE NOTE 10

12 ON EACH WAREHOUSE

EXISTING ROOF VENTS

ID (TYP)

PV ARRAY

GENERAL NOTES

D.

C.

EACH SIDE.

WAREHOUSE AND THREE SIGNS EQUALLY SPACED ON

DETAIL #15. PLACE ONE SIGN ON EACH END OF

TO ONLY (2) PERSONS AT A TIME", SEE E-625, SIGN

WAREHOUSES TO INDICATE "ROOF ACCESS IS LIMITED

PLACE SIGNAGE ON EXTERIOR WALLS OF

UPON PROJECT COMPLETION CONTRACTOR SHALL B.

0.6kN/m2).

LOAD USED IN THE BUILDING ROOF DESIGN (12psf, & MATERIAL STACKING TO BE LESS THAN THE LIVE

CONTRACTOR SHALL LIMIT PERSONNEL, EQUIPMENT, A.

INSTALL MINIMUM FOUR FASTENERS PER PANEL.

CAN DAMAGE THEM. WALK ALONG THE PURLINS.

HIGH RIBS OF THE PANELS. STEPPING ON THE HIGH RIBS

WHEN WALKING ON THE ROOF DO NOT STEP ON THE

PLAN NOTES

NOTE A

SEE PLAN

NOTE A

SEE PLAN

PULL BOXES (TYP)

ROOF-MOUNTED

NEW

(TYP)

COMBINERS

NEW

SCALE: NOT TO SCALE

PV ELECTRICAL SITE PLAN

(TYP)

RECOMBINER

MASTER

NOTE B

SEE PLAN

IN CONCRETE

ENCASE CONDUITS

SEE E-503(TYP)

PULLBOX

COMMUNICATIONS

(TYP)

PULLBOX

ELECTRICAL

TRANSFORMER

STEP-UP

PAD MOUNTED

SWITCHBOARD

AC COMBINER

(TYP)

PV DISCONNECT

SHEET SYMBOLS:

COMMUNICATION CONDUCTOR

DRIVEWAYS, PARKING AREAS, ETC. REF. SHEET E-505.

UNDER ROADS,CONDUITS ENCASED IN CONCRETE

VOLTAGE

UNDERGROUND PVC CONDUITS SCH. 80 MEDIUM

UNDERGROUND PVC CONDUITS SCH. 80 LOW VOLTAGE

MANHOLE, MH-##

BUILDING.

BESS SHALL BE MIN 100 FT AWAY FROM ANY OCCUPIED 13.

AROUND LIGHTING PROTECTON SYSTEM.

CENTERLINE OF THE ROOF. CONTRACTOR SHALL WORK

TERMINALS ARE PLACED ALONG THE EDGE AND

PROTECTION SYSTEM INSTALLED ON THE ROOF. AIR

BOTH WAREHOUSE BUILDINGS HAVE A LIGHTNING 12.

INSTALLED ON CONCRETE PADS.

EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 11.

TYPE USE-2.

CONDUIT AND ARE EXPOSED TO SUNLIGHT WILL BE

FOR WIRES IN CONDUIT. CONDUCTORS NOT IN

600V INSULATION SUITABLE FOR WET & DRY LOCATIONS

WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES C, 10.

SERIES.

PHOTOVOLTAIC STRINGS HAVE 11 SOLAR MODULES IN 9.

SIZES.

REFER TO SINGLE LINE FOR CONDUIT AND CONDUCTOR 8.

DRAWING ARE ESTIMATED.

LOCATIONS OF EXISTING UTILITIES SHOWN ON

AUTHORITIES TO AVOID ANY EXISTING UTILITIES.

UNDERGROUND WORK WITH THE APPROPRIATE

CONTRACTOR SHALL COORDINATE AND CONFIRM ALL

VOLTAGE CABLES, AND OTHER UTILITIES IN WORK AREA.

THERE ARE UNDERGROUND WATER LINES, LOW 7.

ARE IDENTICAL FOR BOTH WAREHOUSES.

CAMP ARIFJAN. THE GENERAL LAYOUT AND EQUIPMENT

EQUIPMENT ON THE ROOF OF TWO WAREHOUSES AT

THIS PROJECT CALLS FOR INSTALLING PHOTOVOLTAIC 6.

FUTURE USE. CAP ENDS OF ALL UNUSED CONDUITS.

PLACE PULL CORD IN SPARE UNUSED CONDUITS FOR 5.

BOXES WITH STAINLESS STEEL CABLE TAGS.

IDENTIFY AND LABEL ALL CABLES IN MANHOLES & PULL 4.

ENCASED.

METERS OF ROADWAY EDGE SHALL BE CONCRETE

ROADS, DRIVEWAYS, PARKING AREAS, AND WITHIN 2

PORTIONS OF THE DUCTBANK CROSSING UNDER

CONDUITS WILL BE DIRECT BURIED EXCEPT FOR 3.

2 METERS ALONG ENTIRE ROUTE OF DUCTBANK.

CONTRACTOR SHALL PLACE CONDUIT SPACERS EVERY 2.

SCHEDULE 80 PVC.

UNDERGROUND CONDUITS ARE SIZED 103mm 1.

21.7kgSOLAR PANEL WEIGHT

(1024 X 2024 X 40)mmSOLAR PANEL DIMENSIONS

10.47ASHORT CIRCUIT CURRENT

49.3VOPEN CIRCUIT VOLTAGE

9.86AMAX POWER CURRENT

40.6VMAX POWER VOLTAGE

400WSTC WATTAGE RATING

3168TOTAL NUMBER OF PANELS

EQUIPMENT RATING:

SOLAR PANEL BASIS OF DESIGN

SEE E-503(TYP)

PULLBOX

COMMUNICATIONS

I.

ACCORDANCE TO IEC 62305-3.

THE DC AND AC SIDE THE INVERTER(S) IN

APPLY TYPE 1+2 SPDs (SURGE PROECTION DEVICE) ON H.

IEC 62561-1.

MUST MEET THE REQUIREMENTS IN ACCORDANCE TO

THE PV-SYSTEM AND COMBINATION WITH THE CLAMPS

OF THE PV-SYSTEM. THE MOUNTING STRUCTURE OF

BETWEEN THE LPS AND THE MOUNTING STRUCTURE

USE APPROVED CLAMPS TO MAKE THE CONNECTION G.

BONDING, USING 16mm2 CU.

CONNECTED FOR LIGHTNING EQUIPOTENTIAL

OF THE PV-SYSTEM AND THE LPS MUST BE

DISTANCE IS NOT KEPT (S<50cm): THE SUBSTRUCTURE

PROTECTION AREA OF THE LPS AND THE SEPARATION

IN CASE THE PV-SYSTEM IS PLACED WITHIN THE F.

6mm2 CU IN ACCORDANCE TO EN 62305-3.

BONDING OF THE PV-SYSTEM IS REQUIRED, USING

CONNECTED. ONLY FUNCTIONAL EQUIPOTENTIAL

THE PV-SYSTEM AND THE LPS SHOULD NOT BE

SYSTEM IS KEPT (S>50CM): THE SUBSTRUCTURE OF

DISTANCE BETWEEN THE PV-SYSTEM AND THE LPS-

PROTECTION AREA OF HTE LPS AND THE SEPARATION

IN CASE THE PV-SYSTEM IS PLACED WITHIN THE E.

SHALL BE DESIGNED AND INSTALLED PER IEC 62305

THAT PROVIDES ADEQUATE PROTECTION. THE LPS

SOLAR PANELS, PROVIDE AND INSTALL A NEW LPS

AGAINST A PROBABLE LIGHTNING STRIKE TO THE

PROVIDE AN ADEQUATE ZONE OF PROTECTION

ON THE EXISTING LPS. IF THE EXISTING LPS DOES NOT

PERFORM A ZONE OF PROTECTION ANALYSIS BASED

LIGHTNING NOTES

M

A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-104

IN

V

E R

T E

R E

Q U

IP

M

E N

T L

A Y

O U

T B

U

IL

D

IN

G S

N .T

.S

N

SCALE: NOT TO SCALE

BUILDINGS 4001 & 4002 INVERTER EQUIPMENT LAYOUT

GATE

PEDESTRIAN

CHAIN-LINK FENCE(TYP)

(INV-1)

INVERTER

630KW

(RCBN-1)

RECOMBINER

MASTER

(RCBP-1)

RECOMBINER

MASTER

(D-1N)

DISCONNECT

(D-1P)

DISCONNECT

SEE S-502

CONCRETE PAD

EQUIPMENT

SEE E-503 (TYP)

PULL BOX #1

ELECTRICAL

SEE E-503 (TYP)

PULL BOX

COMMUNICATIONS

FROM BUILDING 4001

DOWN CONDUITS

REF. E-601

BUILDING 4001

CONDUITS TO

BUILDING 4001

M

+/-8M

+/-1M

M

BUILDING 4002

CHAIN-LINK FENCE(TYP)

SEE S-502

CONCRETE PAD

EQUIPMENT

SEE E-503 (TYP)

PULL BOX

COMMUNICATIONS

SEE E-503 (TYP)

PULL BOX #1

ELECTRICAL

(INV-2)

INVERTER

630KW

(RCBP-2)

RECOMBINER

MASTER

(RCBN-2)

RECOMBINER

MASTER

(D-2N)

DISCONNECT

(D-2P)

DISCONNECT

GATE

PEDESTRIAN

REF. E-601

BUILDING 4002

CONDUITS TO

FROM BUILDING 4002

DOWN CONDUITS

M

+/-8M

M

+/-1M

BUILDING.

BESS SHALL BE MIN 100 FT AWAY FROM ANY OCCUPIED 9.

ON SHEET E-500.

GROUNDED. REFERENCE FENCE GROUNDING DETAIL 8

SHEET. ENSURE FENCE AND GATES ARE BONDED AND

ELECTRICAL CONCRETE PADS AS SHOWN ON THIS

INSTALL CHAIN LINK FENCE AND GATES AROUND 8.

APPROXIMATE.

EQUIPMENT INSTALLED. DIMENSIONS SHOWN ARE

PADS SHALL BE SIZED TO ACCOMODATE ACTUAL

SHALL BE INSTALLED ON CONCRETE PADS. CONCRETE

ELECTRICAL EQUIPMENT PLACED AT GROUND LEVEL 7.

ALL USE-2 STRING WIRING TO BE OPEN FREE AIR.6.

BE TYPE USE-2.

NOT IN CONDUIT AND ARE EXPOSED TO SUNLIGHT WILL

LOCATIONS FOR WIRES IN CONDUIT. CONDUCTORS

600V INSULATION SUITABLE FOR WET & DRY

WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES C, 5.

NEMA 4 OR HAVE AN IP 65 RATING.

ELECTRICAL ENCLOSURE CABINETS SHALL BE RATED 4.

CONDUCTOR SIZES.

REFER TO SINGLE LINE DIAGRAMS FOR CONDUIT AND 3.

INDICATED AS EXISTING.

ALL EQUIPMENT ON THIS SHEET IS NEW UNLESS 2.

AUTHORITIES TO AVOID ANY EXISTING UTILITIES.

UNDERGROUND WORK WITH THE APPROPRIATE

SHALL COORDINATE AND CONFIRM ALL

VOLTAGE CABLES IN WORK AREA. CONTRACTOR

THERE ARE UNDERGROUND WATER LINES AND LOW 1.

GENERAL NOTES

REF. E-101 & E-600

SWITCHBOARD

TO AC COMBINER

BOX

STATION CONTROL

CABLE TO WEATHER

COMMUNICATIONS

CONDUITS

ENCASED

CONCRETE

CONDUITS

ENCASED

CONCRETE

SEE E-503 (TYP)

PULL BOX #1

ELECTRICAL

SEE E-503 (TYP)

PULL BOX

COMMUNICATIONS

SEE E-503 (TYP)

PULL BOX

COMMUNICATIONS

+/-1.5M

+/-1.5M A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-105

A N

D B

E S

S L

A Y

O U

T A

C C

O M

B

IN

E R

S W

IT

C

H B

O A

R D

N .T

.S

N

BOX

CONTROL

HMI

PAD, SEE S-502

CONCRETE

GATE

PEDESTRIAN

NEW

AREA

FROM WAREHOUSE

COMM CONDUIT

REF. E-101 & E-600

INVERTERS

FROM SOLAR

TRANSFORMER

3-PH, 415/240-11KV, 50HZ

2500 KVA STEP-UP

PAD-MOUNTED

MANHOLE, MH-05

TO ELECTRICAL

+/-4M

M

+/-2M

+/-10M

M

M

+/-1M +/-14M

DIMENSION CONCRETE PAD SLAB AS SHOWN.

THE CANOPY SIZE OF AC COMBINER SWITCH BOARD TO MATCH 13.

EQUIPMENT AND EQUIPMENT CLEARANCES.

SHOWN. HEIGHT OF CANOPY TO BE COORDINATED WITH HEIGHT OF

THE BUILDING SIZES TO MATCH DIMENSION CONCRETE PAD SLAB AS 12.

FACILITY COMPONENTS.

OPERATED TO VIEW DATA FROM INVERTERS AND OTHER SOLAR

A HUMAN MACHINE INTERFACE (HMI) CONTROL BOX WILL BE 11.

BESS SHALL BE MIN 100 FT AWAY FROM ANY OCCUPIED BUILDING.10.

USING ASTM A780 ZINC RICH PAINT.

PER ASTM A153/A153M. REPAIR DAMAGE TO GALVANIZED COATINGS

9.7. ALL FASTENERS AND ACCESSORIES TO BE HOT DIPPED GALVANIZED

AFTER ERECTION AS NECESSARY.

ZINC BASED PRIMER, SHOP PAINTED, AND REPAIRED IN THE FIELD

9.6. ALL STEEL MUST BE SHOP CLEANED PER SSPC SP3, PRIMED WITH A

BURNING WILL NOT BE PERMITTED.

DRILLED. THE MARKING OF HOLES OR ENLARGEMENTS OF HOLES BY

BOLTED. HOLES FOR BOLTING MUST BE SHOP PUNCHED OR FIELD

9.5. STRUCTURAL STEEL CONNECTIONS TO BE SHOP WELDED AND FIELD

SERIES LOW HYDROGEN ELECTRODES.

PERMITTED. ALL WELDING MUST BE PERFORMED USING E70XX

(LATEST EDITIONS). "NON-PREQUALIFIED JOINTS" ARE NOT

9.4. USE PREQUALIFIED WELDED JOINTS PER AISC 360 AND AWS D1.1

TO ASTM F1554 250 MPa [GRADE 36].

C.2. ANCHOR RODS MUST BE HEAVY HEX-HEAD TYPE CONFORMING

NUTS.

GRADE A325 BOLTS W/ MATCHING WASHER AND HEAVY HEX HEAD

C.1. BOLTED CONNECTIONS MUST BE BEARING TYPE, ASTM F3125,

9.3. BOLTS AND ANCHORS:

EN10025-2 250MPa YIELD STRENGTH [36 KSI].

9.2. STEEL SHAPES, PLATES, CHANNELS, AND ANGLES MUST CONFORM TO

STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES”.

STRUCTURAL STEEL BUILDINGS" (THIRD EDITION) AND THE “CODE OF

BUILDINGS" (FIFTEENTH EDITION), "SEISMIC PROVISIONS FOR

CONSTRUCTION (AISC) "SPECIFICATIONS FOR STRUCTURAL STEEL

ACCORDANCE W/ THE AMERICAN INSTITUTE OF STEEL

9.1. STRUCTURAL STEEL WORK IS TO BE DETAILED AND CONSTRUCTED IN

9. CANOPY STRUCTURAL STEEL NOTES:

PROVIDE DESIGN SUBMITTAL TO GOVERNMENT FOR APPROVAL.

SEISMIC DESIGN CATEGORY: "D"

Ss=0.57 ; S1 = 0.27

PARAMETERS

MAPPED SPECTRAL RESPONSE ACCELERATION

RISK CATEGORY=II

3. EARTHQUAKE LOADS (KUWAIT CITY)

WIND SPEED=161 KMPH

RISK CATEGORY=II

2. WIND LOADS (KUWAIT CITY)

SELF-WEIGHT

1.2 DEAD LOADS:

CANOPY ROOF = 20PSF

1.1 LIVE LOADS:

1. GRAVITY LOADS:

WITHSTANDING THE FOLLOWING DESIGN LOADS:

STRUCTURAL ENGNINEERING. THE CANOPY MUST BE CAPABLE OF

EQUIPMENT. DESIGN MUST BE IN ACCORDANCE WITH UFC 3-301-01

DIMENSIONS MEET CLEARANCES AS REQUIRED BY THE ELECTICAL

CONCRETE PAD AND A MINIUMUM OF 2.5M TALL. ENSURE CANOPY

PAD. THE CANOPY MUST EXTEND TO THE FULL LIMITS OF THE

THE AC COMBINER SWITCHBOARD AND BESS EQUIPMENT CONCRETE

CONTRACTOR SHALL DESIGN AND CONSTRUCT A CANOPY TO COVER 8.

INSTALLATION MANUAL.

BESS SYSTEM TO BE INSTALLED PER MANUFACTURER'S 7.

SHEET E-500.

AND GROUNDED. REFERENCE FENCE GROUNDING DETAIL 8 ON

SHOWN ON THIS SHEET. ENSURE FENCE AND GATES ARE BONDED

INSTALL CHAIN LINK FENCE AND PEDESTRIAN ACCESS GATE AS

PLACE NEW FENCE TO ENCLOSE THE MICROGRID EQUIPMENT. 6.

SHOWN ARE APPROXIMATE.

TO ACCOMODATE ACTUAL EQUIPMENT INSTALLED. DIMENSIONS

INSTALLED ON CONCRETE PADS. CONCRETE PADS SHALL BE SIZED

ELECTRICAL EQUIPMENT PLACED AT GROUND LEVEL SHALL BE 5.

AN EQUIVALENT IP RATING.

ELECTRIAL ENCLOSURE CABINETS SHALL BE RATED NEMA 4 OR HAVE 4.

SIZES.

REFER TO SINGLE LINE DIAGRAMS FOR CONDUIT AND CONDUCTOR 3.

EXISTING.

ALL EQUIPMENT ON THIS SHEET IS NEW UNLESS INDICATED AS 2.

AUTHORITIES TO AVOID ANY EXISTING UTILITIES.

UNDERGROUND AND CONFIRM ALL WORK WITH THE APPROPRIATE

CABLES IN WORK AREA. CONTRACTOR SHALL COORDINATE ALL

THERE ARE UNDERGROUND WATER LINES AND LOW VOLTAGE 1.

GENERAL NOTES

1 SCALE: NOT TO SCALE

AC COMBINER SWITCHBOARD AND BESS LAYOUT

SWITCHBOARD

AC COMBINER

STORAGE SYSTEM (BESS)

1000KW/2000KWh BATTERY ENERGY

STREET (TYP)

IN CONRETE UNDER

ENCASE DUCTBANK

SEE E-503(TYP)

PULLBOX

COMMUNICATIONS

SEE E-503(TYP)

PULLBOX

COMMUNICATIONS

SEE E-503(TYP)

PULLBOX

COMMUNICATIONS

FENCE

CHAIN-LINK

NEW

FENCE

CHAIN-LINK

NEW

PAD, SEE S-502

CONCRETE

GATE

SWING GATE

NEW

M

.6

M

+/-23M

M

A M

E N

D M

E N

T

/0

/0

M

+/-4M+/-10M

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-106

E L

E C

T R

IC

A

L S

IT

E

P L

A N

T

IP

-C A

R E

A

N .T

.S

N

MH-07

T780

SCALE: NOT TO SCALE

TIP-C AREA ELECTRICAL SITE PLAN

LOCATION

TIP-C SWITCHGEAR

CONTAINERIZED

PROPOSED

LOCATION

TRANSFORMER

STEP-DOWN

PROPOSED

MH-06

MH-08

T786

T788

T784

B4112

SHEET SYMBOLS:

DRIVEWAYS, PARKING AREAS, ETC. REF. SHEET E-505.

UNDER ROADS,CONDUITS ENCASED IN CONCRETE

VOLTAGE

UNDERGROUND PVC CONDUITS SCH. 80 MEDIUM

UNDERGROUND PVC CONDUITS SCH. 80 LOW VOLTAGE

MANHOLE, MH-##

GENERAL NOTE

PURCHASED STEP-DOWN TRANSFORMER.

SIZE OF THE CONCRETE PAD BASED ON THE

CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE 4.

EQUIPMENT.

COORDINATION WILL BE REQUIRED WITH FUTURE

CONSTRUCTION OF THIS PROJECT'S SCOPE OF WORK.

BY OTHERS. TIP-C SWITCHGEAR WILL BE IN PLACE TO

CONTAINERIZED TIP-C SWITCHGEAR IS FUTURE WORK 3.

LOCATION TO BE VERIFIED ON THE SITE WALK.

EQUIPMENT LOCATION IS DIAGRAMATIC. THE ECACT 2.

BRITISH STANDARD 7671.

ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH

DESIGNED IN ACCORDANCE WITH NEC 2020. ALL OTHER

ELECTRICAL INTERCONNECTION WORK HAS BEEN 1.

POI

BY OTHERS

GENERATORS,

BY OTHERS

CONTAINER,

BY OTHERS

TRANSFORMER,

BY OTHERS

CONTAINER,

BY OTHERS

FUEL TANK,

SEE E-503 (TYP)

PULLBOX

COMMUNICATIONS

SEE E-503 (TYP)

PULLBOX

COMMUNICATIONS

SEE E-503 (TYP)

PULLBOX

COMMUNICATIONS

SEE E-503 (TYP)

PULLBOX

COMMUNICATIONS

A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-107

E L

E C

T R

IC

A

L S

IT

E

P L

A N

M C

F A

R E

A

N .T

.S

N

MH-18

LOCATION

UDS

PROPOSED

MCF

SCALE: NOT TO SCALE

MCF AREA ELECTRICAL SITE PLAN

(TYP)

STREET CROSSING

IN CONRETE UNDER

ENCASE CONDUITS

MH-17

GAIN ACCESS INTO BUILDING

CONDUITS CAN BE USED TO

AVAILABLE UNDERGROUND

INTO BUILDING

TUNNEL ACCESS

SHEET SYMBOLS:

DRIVEWAYS, PARKING AREAS, ETC. REF. SHEET E-505.

UNDER ROADS,CONDUITS ENCASED IN CONCRETE

VOLTAGE

UNDERGROUND PVC CONDUITS SCH. 80 MEDIUM

UNDERGROUND PVC CONDUITS SCH. 80 LOW VOLTAGE

MANHOLE, MH-##

INSIDE BUILDING

EXISTING SGB

LOCATION OF

INSIDE BUILDING

EXISTING SGA

LOCATION OF

PURCHASED BY THE CONTRACTOR.

CONCRETE PAD BASED UPON THE UDS EQUIPMENT

CONTRACTOR SHALL DETERMINE THE SIZE OF 3.

COMM UTILITIES.

CONTRACTOR NEED TO DIB BENEATH THE EXISTING

THERE ARE SEVERAL COMM DUCT BANK IN THE AREA. 2.

SHALL VERIFY THE BEST ROUTE ON THE SITE.

THE DUCT BANK ROUTE IS DIAGRAMATIC. CONTRACTOR 1.

NOTES:

SEE NOTES 1 & 2

SEE ASPHALT PAVING SHEET S-502

CONDUIT AND REPAVE ASPHALT ROAD,

ROAD, INSTALL NEW CONCRETE ENCASED

CONTRACTOR SHALL SAW CUT ASPHALT

A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-600

O N

E -L

IN

E

D

IA

G R

A M

O V

E R

A L

L E

L E

C T

R

IC

A L

N .T

.S

LOAD BUS

RATED

100%

1000AT

3P, GFP

RATED

100%

1000AT

3P, GFP

RATED

100%

1600AT

1600AF

3P, GFP

20A

3P

DEMANDS EXCEED MICROGRID AND ZONE 4.

13. EXISTING MCF GENERATORS SHALL KICK IN AS LOAD

DEMANDS EXCEED MICROGRID POWER.

12. ZONE 4 POWER PLANT SHALL KICK WHEN LOAD

CIRCUIT BREAKERS IN TIC-C IS 400/230V.

THE CONTROL POWER VOLTAGE RATING FOR THE MV 11.

OUTAGE AND/OR AS PROGRAMMED.

ISLANDING MODE WILL BE ACTIVATED DURING POWER 10.

FENSE.

CONTRACTOR WITHIN THE PERIMETER OF THE BESS

MICROGRID CONTROL SYSTEM MUST BE INSTALLED PER

OPERATOR INTERFACE FOR CONTROL OF THE

LOCATION OF MICROGRID CONTROLLER HARD AND MAIN 9.

AND AC SIDE OF THE INVERTER(S).

8. APPLY SPDs (SURGE PROTECTION DEVICE) ON THE DC

CIRCUIT BREAKER TRIP SETTING ACCORDING TO THE FLA.

7. CONTRACTOR SHALL PROVIDE, INSTALL, AND SET THE

BACKFEED TO SSW DURING GRID POWER OUTAGE.

UDS MV SWITCH (A) AND (B) TO BE SET TO PREVENT 6.

MODULE.

PROVIDE NEW MV WALK-IN SWITCHGEAR CONTAINER 5.

THE BUS OF THE 11KV SWITCHGEAR.

INTERCONNECT TO CIRCUIT BREAKER AT THE END OF

LOADSIDE CONNECTION: CONTRACTOR TO 4.

LOAD SIDE INTERCONNECTION.

2020 NATIONAL ELECTRIC CODE (NEC), SECTION 705.12,

SHALL COMPLY WITH ALL RELEVANT SECTIONS OF THE

NEW SWITCHGEAR, SWITCHBOARD, AND INVERTERS 3.

RATED NEMA 4.

ALL NEW EXTERIOR ELECTRICAL ENCLOSURES SHALL BE 2.

CONTROLS EQUIPMENT.

RELAYS, PT'S, CT'S AND OTHER REQUIRED SYSTEM

CONTRACTOR SHALL PROVIDE ALL NEW METERS, 1.

NOTES

NEEDED.

DURING BOTH DAYLIGHT AND NIGHT TIME HOURS AS

DAYLIGHT HOURS. THE BESS SHALL SUPPORT THE LOAD

THE PV SYSTEM SHALL SUPPORT THE LOAD DURING

POWER.

HOST NATION UTILITY SHALL BE THE PRIMARY SOURCE OF

AND BY THE UTILITY DURING THE NIGHT AS NEEDED.

BESS SHALL BE CHARGED BY THE PV SYSTEM DURING DAY, d.

PEAK HOURS.

THE BESS SHALL BE UTILIZED FOR PEAK SHAVING DURING c.

b.

a.

SYSTEM OPERATION

3P

200A

ONE-LINE DIAGRAM

80% RATED

4000AT

4000AF

3P, GFP

GND IN 129C

(3) 95mm2 (MV105) +(1) 16mm2

& 120mm2 GND IN 129C)

4 SETS OF (4C - 240mm2

& 70mm2 GND in 129C)

4 SETS OF (4C - 240mm2

& 70mm2 GND in 129C)

4 SETS OF (4C - 240mm2

20A

3P

20A

3P

& 240mm2 GND IN 129C)

8 SETS OF (4C - 400mm2

L < 880 M_

L < 12 M_

L < 90 M_

L < 38 M

L < 4 M_

SHEET E-602

SEE

SHEET E-601

SEE

INVERTER (INV-1)

PROPOSED 630KW

100% RATED

1000AT

3P

100% RATED

1000AT

3P

PROPOSED 1000KW/2000KWh BESS

TRANSFORMER - T1

11kV-415/240V, 5.3% IMPED

PROPOSED 2500kVA

SECONDARY

TRANSFORMER

FAULT AMPS AT

65.6k AVAILABLE

PROPOSED AC COMBINER SWITCHBOARD 415/240V, 4W, 4000A, 3PH, 100kAIC, NEMA 4

INVERTER

2000KWh

1000KW/

LITHIUM-ION

BATTERY STORAGE

INVERTER (INV-2)

PROPOSED 630KW

TYPE

VACUUM

12kV RATED

25kA

200AT

800AF

11KV-415/240V, 3PH, 50HZ

2500KVA TRANSFORMER

PROPOSED MCF UDS

PROPOSED TIP-C 11KV SWITCHGEAR (TIP-C) 11KV, 800A, 3PH, 3W, 50HZ, 25kAIC, NEMA 4

SEE NOTE 4

INTERCONNECTION (POI)

LOADSIDE POINT OF

20A

3P

SPARE

TYPE

VACUUM

12kV RATED

25kA

200AT

800AF

TYPE

VACUUM

12kV RATED

25kA

200AT

800AF

TYPE

VACUUM

12kV RATED

25kA

200AT

800AF

TYPE

VACUUM

12kV RATED

25kA

200AT

800AF

T2

TIP-C SPARE

TYPE

VACUUM

12kV RATED

25kA

200AT

800AF

TYPE

VACUUM

12kV RATED

25kA

200AT

800AF

POWER PLANT

ZONE 4

TO EXISTING

EXISTING SSW (B2350)

S2 S3

S1

SWITCHGEAR

MOUNTED

EXISTING PAD

& 35mm2 GND IN 129C

3-300mm2 (MV105)

L < 1560 M_

L < 1262 M_ L < 393 M_

TYPE

VACUUM

12kV RATED

25kA

200AT

800AF

SPARE

3P

200A

5.3% Z, TRANSFORMER

11kV-415/240V, 3-PHASE

PROPOSED 3000kVA

SECONDARY

TRANSFORMER

FAULT AMPS AT

78.8k AVAILABLE

BUS DUCT

SG-TIE

SWITCHGEAR SGA, 415/240, 6300A, 3PH, 4W, 100KAIC (MCF) BUILDING

EXISTING

S G

A

S G

A

S G

A

S G

A

S G

A

S G

A

S G

B

S G

A

S G

A

S G

A

S G

A

S G

A

S G

A

S G

A

S G

A

S G

A

S G

A

S G

A

S G

A

SGB

SWITCHGEAR

PARALELLING

GENERATOR

EXISTING

3200AF

G3G2G1

GENERATORS

EXISTING

SWITCH

FUSED

A

4000AF

3P

B

ARRESTORS

SURGE

12KV

3PH, 4W, 50HZ

11KV-415/240V

SUBSTATION

UNIT DISTRIBUTION

2500 KVA

4000AT

4000AF

3200AT

3P

RATED

800A

3-PH, 4W, 50HZ

4000A, 415/240V

SEE NOTE 6

SEE NOTE 7

& 240mm2 GND IN 129C)

7 SETS OF (4-300mm2

SEE NOTE 5

& 35mm2 GND IN 129C

3-300mm2 (MV105)

& 35mm2 GND IN 129C

3-300mm2 (MV105)

T1

TIP-C

PROPOSED BESS

95mm2 GEC

103C

& 16mm2 GND IN

3-95mm2 (MV105)

L < 3 M

L < 1502 M

A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-610

O N

E -L

IN

E

D

IA

G R

A M

D

A T

A M

O N

IT

O

R

IN

G T

E L

E C

O M

M U

N

IC

A T

IO

N

S

N .T

.S

SCALE: NO SCALE

TELECOMMUNICATIONS & DATA MONITORING ONE-LINE DIAGRAM

GENERAL NOTES:

MANUFACTURER RECOMMENDATION.

THE WEATHER STATION TO THE SENSOR PER

CONTRACTOR SHALL PROVIDE C3 AND C4 CABLE FROM 5.

CABLE SHALL BE GEL FILLED AND WATERPROOF.

WITH MEDIA CONVERTER. EXTERIOR COMMUNICATIONS

CATEGORY 6 CABLE, OTHERWISE USE FIBER OPTIC CABLE

THAN 100 METERS OF CABLE SHALL CONSIDER USING

COMMUICATIONS BETWEEN EQUIPMENT REQUIRING LESS 4.

MICROGRID CONTROLS AND SOFTWARE PACKAGE.

CONTRACTOR SHALL PROVIDE A COMPLETE FUNCTIONAL 3.

AS EXISTING.

ALL EQUIPMENT ON THIS SHEET IS NEW UNLESS LABELED 2.

APPROVAL.

CONDUITS AND EQUIPMENT SHALL BE SUBJECT TO

TO AVOID CONFLICTS. ALL FINAL LOCATIONS OF NEW

WITH JOB CONDITIONS AND SHALL ARRANGE ALL WORK

EQUIPMENT. CONTRACTOR SHALL BECOME FAMILIAR

EXACT ROUTES OF WIRING AND EXACT LOCATION OF

THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW 1.

MASTER CONTRPLLER. (SPECS PER MANUFACTURER)

COMPATIBLE WITH THE INSTALLED EQUIPMENT.

MODULE SHALL BE THE SAME NAME BRAND AND FULLY

PROVIDE COMMUNICATION MODULE. COMUNICATION

KEYED NOTES:

WEATHER STATION TO SENSOR100mm CONDUITPER MANUFACTURER RECOMMENDATONSENSORC4

WEATHER STATION TO SENSOR100mm CONDUITPER MANUFACTURER RECOMMENDATIONSENSORC3

BETWEEN EQUIPMENT100mm CONDUIT1 - 12 STRAND SM FOCCOMC2

BETWEEN EQUIPMENT100mm CONDUITCAT-6COMC1

DESCRIPTION OF RUNRACEWAY TYPECONDUCTOR SIZESERVICECABLE ID

NEW CABLE SCHEDULE

BESS INVERTER BESS BATTERY

630KW INVERTER (INV-1)

630KW INVERTER (INV-2)

1 1

C1

C1

C1 C1

C1

C2

SWITCHGEAR AT TIP-C

PROPOSED MV

A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-625

S

IG

N A

G E

P

V S

Y S

T E

M N

.T .S

D-1N

INV-1

NEGATIVE ARRAY

DISCONNECT SWITCH

PHOTOVOLTAIC MAINTENANCE DC

D-1P

INV-1

POSITIVE ARRAY

DISCONNECT SWITCH

PHOTOVOLTAIC MAINTENANCE DC

DC DISCONNECT SIGNAGE

DC DISCONNECT SIGNAGE

D-2N

INV-2

NEGATIVE ARRAY

DISCONNECT SWITCH

PHOTOVOLTAIC MAINTENANCE DC

DC DISCONNECT SIGNAGE

D-2P

INV-2

POSITIVE ARRAY

DISCONNECT SWITCH

PHOTOVOLTAIC MAINTENANCE DC

DC DISCONNECT SIGNAGE

WARNING

PV ARRAY WARNING

IN OVERVOLTAGE ON ARRAY OR INVERTER

GROUNDED CONDUCTORS MAY RESULT

DISCONNECTION OF NEUTRAL OR

PHOTOVOLTAIC ARRAY.

CAUTION: SOLAR CIRCUIT

CAUTION! SOLAR CIRCUIT

REQUIREMENT)

REQUIRED (DURABLE ADHESIVE MATERIALS MUST MEET THIS

FOR WEATHER RATING. UL LISTING OF MARKINGS NOT

THE ENVIRONMENT. UL 696 SHALL BE USED AS A STANDARD

REFLECTIVE WEATHER RESISTANT MATERIALS SUITABLE FOR

WHITE LETTERING, ARIAL OR SIMILAR FONT, NON-BOLD.

AND FORMAT: "CAUTION: SOLAR CIRCUIT" RED BACKGROUND,

ALL PV COMBINER AND JUNCTION BOXES. MARKING CONTENT

AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT

CUTTING THEM. MARKING SHALL BE PLACED EVERY 3 METERS,

JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID

CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND

MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR PV

CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED

CAUTION! SOLAR ELEC. SYS.

MATERIALS MUST MEET THIS REQUIREMENT)

OF MARKINGS NOT REQUIRED (DURABLE ADHESIVE

BE USED AS A STANDARD FOR WEATHER RATING. UL LISTING

MATERIALS SUITABLE FOR THE ENVIRONMENT. UL 696 SHALL

FONT, NON-BOLD. REFLECTIVE WEATHER RESISTANT

LETTER HEIGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR

RED BACKGROUND, WHITE LETTERING, MINIMUM 10mm

CONTENT: "SOLAR ELECTRIC SYSTEM SYSTEM CONNECTED"

THE LOCATION WHERE THE LEVER IS OPERATED. MARKING

SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM

THE MARKING SHALL BE PLACED ADJACENT TO THE MAIN

MAIN SERVICE DISCONNECT. FOR COMMERCIAL APPLICATION,

SHOCK HAZARD WARNING

ELECTRIC SHOCK HAZARD

WARNING!

POSITION.

MAY BE ENERGIZED IN THE OPEN

TERMINAL ON BOTH LINE AND LOAD SIDES

DO NOT TOUCH TERMINALS.

SHOCK HAZARD WARNING

PHOTOVOLTAIC

WARNING!

PERSONNEL ONLY.

OR SOURCES(S). AUTHORIZED

POWER. DO NOT CONNECT ANY LOAD(S)

COMBINER BOX IS FED BY PHOTOVOLTAIC

DC COMBINER BOX

PLACE SIGNAGE ON ALL DC COMBINER BOXES.

SWITCHBOARD

AC COMBINER

WARNING

IN THE OPEN POSITION.

AND LOAD SIDES MAY BE ENERGIZED

TERMINALS. TERMINAL ON BOTH LINE

ELECTRIC SHOCK HAZARD DO NOT TOUCH

AC DISCONNECT SIGNAGE

SERVICE LOCATION SIGNAGE

BACKGROUND WITH WHITE ENGRAVED LETTERS.

MEANS. POINT OF INTERCONNECT SIGNAGE PER NEC 705.12. SIGNAGE SHALL BE RED

PER NEC 690.56B INCLUDE LOCATION OF THE PHOTOVOLTAIC SYSTEM DISCONNECTING

CAUTION!

POWER TO THIS SERVICE IS ALSO SUPPLIED FROM A

PHOTOVOLTAIC AND BESS SYSTEM

WITH DISCONNECTS LOCATED AS SHOWN

V DCxxxMAXIMUM VOLTAGE:

AMPSxxxMAXIMUM CURENT:

V DCxxxOPERATING VOLTAGE:

AMPSxxxOPERATING CURRENT:

V DCxxxMAXIMUM VOLTAGE:

AMPSxxxMAXIMUM CURENT:

V DCxxxOPERATING VOLTAGE:

AMPSxxxOPERATING CURRENT:

V DCxxxMAXIMUM VOLTAGE:

AMPSxxxMAXIMUM CURENT:

V DCxxxOPERATING VOLTAGE:

AMPSxxxOPERATING CURRENT:

V DCxxxMAXIMUM VOLTAGE:

AMPSxxxMAXIMUM CURENT:

V DCxxxOPERATING VOLTAGE:

AMPSxxxOPERATING CURRENT:

DISCONNECT

LOCKABLE

11KV SWITCHGEAR

SWITCHBOARD

AC COMBINER

DISCONNECT

SYSTEM

BUILDING

POWER PLANT

INVERTER SHOCK HAZARD

ELECTRIC SHOCK HAZARD

WARNING!

MAY BE UNGROUNDED AND ENERGIZED.

NORMALLY GROUNDED CONDUCTORS

IF A GROUND FAULT IS INDICATED,

A VISIBLE LOCATION.

THE INSTALLER NEAR THE GROUND-FAULT INDICATOR AT

THE UTILITY INTERACTIVE INVERTER OR BE APPLIED BY

PER NEC 690.5(C) A WARNING LABEL SHALL APPEAR ON

RCBP - "_"

RCBN - "_"

MASTER COMBINER SIGNAGE

INV - "_"

INVERTER BOX SIGNAGE

12 13

PERSONS

ACCESS TO (2)

LIMIT ROOF

(2) PERSONS AT A TIME.

ROOF ACCESS IS LIMITED TO

ROOF ACCESS

NOTES

FOR WEATHER RATING.

FOR ENVIRONMENT. UL 696 SHALL BE USED AS A STANDARD

BOLD, REFLECTIVE WEATHER RESISTANT MATERIALS SUITABLE

HEIGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON-

BACKGROUND, WHITE LETTERING, MINIMUM 10mm LETTER

AND FORMAT MARKING: "CAUTION: SOLAR CIRCUIT" RED

ALL PV COMBINER AND JUNCTION BOXES. MARKING CONTENT

TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT

THEM. MARKING SHALL BE PLACED EVERY 3 METERS, AT

JUNCTION BOXES TO ALERT FIRE SERVICE TO AVOID CUTTING

CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND

MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR PV 5.

AND HAVE A NON-GLARE FINISH. CFC 5-5.1

SYMBOLS AND THEIR BACKGROUND SHALL BE 70% MINIMUM

ARIAL (OR SIMILAR). CONTRAST BETWEEN CHARACTERS,

ALL TEXT SHALL BE CAPITAL LETTERS. FONT TYPE SHALL BE

PRINTED WITH RED LETTERING ON A WHITE BACKGROUND.

SIGNAGE TO BE REFLECTIVE VINYL. SIGNAGE SHALL BE 4.

EQUIPMENT.

CIRCLED NUMBERS SHOW LOCATION OF THE SIGNAGE ON THE 3.

FROM GATE OR DOOR JAMB (STRIKE SIDE).

GLARE FINISH. TOP OF SIGN TEXT 127mm MIN CLEAR SPACE

BACKGROUND SHALL BE 70% MINIMUM AND HAVE A NON-

CONTRAST BETWEEN CHARACTERS, SYMBOLS, AND THEIR 2.

ARIAL (OR SIMILAR).

ALL TEXT SHALL BE CAPITAL LETTERS, FONT TYPE SHALL BE 1.

EXTERIOR SIDE AT 127mm ABOVE BASE OF DOOR.

PLACE ONE SIGN PER EQUIPMENT SHELTER DOOR ON *****

BACKGROUND.

LABEL SHALL BE PRINTED WITH RED LETTERING ON A WHITE ****

BACKGROUND.

SHALL BE PRINTED WITH WHITE LETTERING ON A BLACK

LAMINATE COATING AND OUTDOOR RATED ADHESIVE. LABEL

PRINTED ON ALUMINUM BACKING WITH U-V RATED PLASTIC ***

PRINTED WITH WHITE LETTERING ON A RED BACKGROUND.

MATERIALS MAY MEET THIS REQUIREMENT. LABEL SHALL BE

SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE

ENGRAVED ON REFLECTIVE WEATHER RESISTANT MATERIAL **

BACKGROUND.

SHALL BE PRINTED WITH THE WHITE LETTERING ON A BLACK

ADHESIVE BACKING SUITABLE FOR THE ENVIRONMENT. LABEL

ENGRAVED ON OUTDOOR RATED PLASTIC LAMINATE WITH *

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S. SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S. SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.SCALE: N.T.S.SCALE: N.T.S.SCALE: N.T.S.

SCALE: N.T.S.

A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

T R

IC

T

K

U W

A

IT

T R

A N

S A

T L

A N

T

IC

E X

P E

D

IT

IO

N

A

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

D A

T E

DISTRICT

EXPEDITIONARY

TRANSATLANTIC

of Engineers

US Army Corps

A N

S I

D

P R

O J E

C T

N O

F

IL

E N

A M

E

C K

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D E

S

IG

N E

D B

Y

D W

N B

Y

A T

C A

M P

A R

IF

JA

N K

U W

A

IT

E R

C

IP

F Y

Z

O N

E

M

IC

R O

G R

ID

S

O L

A R

P V a n d B

E S

S

B R

IA

N

R

J O

H N

S O

N

P .E

N O

V

R C

M O

H A

M M

E D

M A

A R

O O

F

P .E

B .R

.J

N O

V E

M B

E R

C E

R T

IF

IE

D F

IN

A

L

E-626

S

IG

N A

G E

B

E S

S N

.T .S

WARNING

OVERCURRENT DEVICE

DO NOT RELOCATE THIS

INVERTER OUTPUT CONNECTION

ENERGY STORAGE

UTILITY LOCKABLE

DISCONNECT SWITCH

WARNING

THIS EQUIPMENT FED BY MULTIPLE SOURCES.

TOTAL RATING OF ALL OVERCURRENT DEVICES,

EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE,

SHALL NOT EXCEED AMPACITY OF BUSBAR.

ENERGY STORAGE DISCONNECT

WARNING ELECTRIC SHOCK HAZARD!

WARNING

ELECTRIC SHOCK HAZARD

DO NOT TOUCH TERMINALS

TERMINALS ON BOTH THE LINE

AND LOAD SIDES MAY BE ENERGIZED

IN THE OPEN POSITION

DO NOT STAND

WARNING

ELECTRICAL HAZARD

AUTHORIZED

PERSONNEL ONLY

WARNING

THIS ENCLOSURE

CONTAINS ENERGIZED

ELECTRICAL

EQUIPMENT

WARNING

THIS ENCLOSURE

CONTAINS ENERGIZED

LITHIUM-ION BATTERY

SYSTEMS

STATIONARY STORAGE COMBINER PANELBOARD

STATIONARY STORAGE COMBINER SWITCHBOARD

WARNING

THIS BATTERY

ELECTROLYTE SOLUTIONS,

WHERE PRESENT, ARE

CORROSIVE LIQUIDS

& BLDG #

ADDRESS

PHYSICAL

WARNING - ELECTRIC SHOCK HAZARD

CONTACT AUTHORIZED REPRESENTATIVE FOR ASSISTANCE

NO USER SERVICEABLE PARTS INSIDE

POINT OF INTERCONNECTION

CAUTION: ENERGY STORAGE SYSTEM CONNECTED

EXTERIOR SIDE AT 127mm ABOVE BASE OF DOOR.

PLACE ONE SIGN PER EQUIPMENT SHELTER DOOR ON *****

BACKGROUND.

LABEL SHALL BE PRINTED WITH RED LETTERING ON A WHITE ****

BACKGROUND.

SHALL BE PRINTED WITH WHITE LETTERING ON A BLACK

LAMINATE COATING AND OUTDOOR RATED ADHESIVE. LABEL

PRINTED ON ALUMINUM BACKING WITH U-V RATED PLASTIC ***

PRINTED WITH WHITE LETTERING ON A RED BACKGROUND.

MATERIALS MAY MEET THIS REQUIREMENT. LABEL SHALL BE

SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE

ENGRAVED ON REFLECTIVE WEATHER RESISTANT MATERIAL **

BACKGROUND.

SHALL BE PRINTED WITH THE WHITE LETTERING ON A BLACK

ADHESIVE BACKING SUITABLE FOR THE ENVIRONMENT. LABEL

ENGRAVED ON OUTDOOR RATED PLASTIC LAMINATE WITH *

WARNING

ELECTRICAL HAZARD

AUTHORIZED

PERSONNEL ONLY

STATIONARY STORAGE COMBINER SWITCHBOARD

STATIONARY STORAGE COMBINER PANELBOARD

WARNING - ELECTRIC SHOCK HAZARD

CONTACT AUTHORIZED REPRESENTATIVE FOR ASSISTANCE

NO USER SERVICEABLE PARTS INSIDE

WARNING

THIS EQUIPMENT FED BY MULTIPLE SOURCES.

TOTAL RATING OF ALL OVERCURRENT DEVICES,

EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE,

SHALL NOT EXCEED AMPACITY OF BUSBAR.

WARNING - ELECTRIC SHOCK HAZARD

CONTACT AUTHORIZED REPRESENTATIVE FOR ASSISTANCE

NO USER SERVICEABLE PARTS INSIDE

ENERGY STORAGE

UTILITY LOCKABLE

DISCONNECT SWITCH

WARNING

OVERCURRENT DEVICE

DO NOT RELOCATE THIS

INVERTER OUTPUT CONNECTION

POINT OF INTERCONNECTION

CAUTION: ENERGY STORAGE SYSTEM CONNECTED

INVERTER "XX"

BESS INVERTER

(FRONT ELEVATION)

AC COMBINER SWITCHBOARD

BATTERY PACK

(FRONT ELEVATION)

UTILITY LOCKABLE

DISCONNECT

POWER PLANT SWITCHGEAR

LOAD SIDE ONLY

SWITCHBOARD

AC COMBMINER

CAUTION: SOLAR CIRCUIT

SHOCK HAZARD LABEL **

POINT OF INTERCONNECTION **

PANELBOARD *

STATIONARY STORAGE COMBINER

SWITCHBOARD *

STATIONARY STORAGE COMBINER

AUTHORIZED PERSONNEL LABEL *

WIREWAY DO NOT STAND *

WARNING LABEL **

ENERGY STORAGE DISCONNECT

DEVICE LABEL *

INVERTER OVERCURRENT

WARNING

WARNING LABEL

ENERGRY STORAGE DISCONNECT

LOCKABLE DISCONNECT SWITCH

ENERGRY STORAGE UTILITY

PANELBOARD OR SWITCH **

STATIONARY STORAGE COMBINER

CAUTION: SOLAR CIRCUIT

ADDRESS PLACARD

SHELTER DOOR PLACARD *****

SHELTER DOOR PLACARD *****

SHELTER DOOR PLACARD *****

BESS

(ONE LABEL PER INVERTER)

INVERTER "XX"

BESS INVERTER LABEL **

BESS

ENERGY STORAGE DISCONNECT

WARNING ELECTRIC SHOCK HAZARD!

WARNING

WARNING

ELECTRIC SHOCK HAZARD

DO NOT TOUCH TERMINALS

TERMINALS ON BOTH THE LINE

AND LOAD SIDES MAY BE ENERGIZED

IN THE OPEN POSITION

16 INVERTER "XX"

BESS

ENERGY STORAGE DISCONNECT

WARNING ELECTRIC SHOCK HAZARD!

WARNING

ENERGY STORAGE DISCONNECT

WARNING ELECTRIC SHOCK HAZARD!

WARNING

NOTES

WEATHER RATING.

ENVIRONMENT. UL 696 SHALL BE USED AS A STANDARD FOR

WEATHER RESISTANT MATERIALS SUITABLE FOR

LETTERS, ARIAL OR SIMILAR FONT, NON-BOLD, REFLECTIVE

LETTERING, MINIMUM 10mm LETTER HEIGHT, ALL CAPITAL

"CAUTION: SOLAR CIRCUIT" RED BACKGROUND, WHITE

BOXES. MARKING CONTENT AND FORMAT MARKING:

PENETRATIONS, AND AT ALL PV COMBINER AND JUNCTION

METERS, AT TURNS AND ABOVE AND/OR BELOW

CUTTING THEM. MARKING SHALL BE PLACED EVERY 3

AND JUNCTION BOXES TO ALERT FIRE SERVICE TO AVOID

CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES,

MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR PV 5.

AND HAVE A NON-GLARE FINISH. CFC 5-5.1

SYMBOLS AND THEIR BACKGROUND SHALL BE 70% MINIMUM

ARIAL (OR SIMILAR). CONTRAST BETWEEN CHARACTERS,

ALL TEXT SHALL BE CAPITAL LETTERS. FONT TYPE SHALL BE

PRINTED WITH RED LETTERING ON A WHITE BACKGROUND.

SIGNAGE TO BE REFLECTIVE VINYL. SIGNAGE SHALL BE 4.

THE EQUIPMENT.

CIRCLED NUMBERS SHOW LOCATION OF THE SIGNAGE ON 3.

FROM GATE OR DOOR JAMB (STRIKE SIDE).

GLARE FINISH. TOP OF SIGN TEXT 127mm MIN CLEAR SPACE

BACKGROUND SHALL BE 70% MINIMUM AND HAVE A NON-

CONTRAST BETWEEN CHARACTERS, SYMBOLS, AND THEIR 2.

ARIAL (OR SIMILAR).

ALL TEXT SHALL BE CAPITAL LETTERS, FONT TYPE SHALL BE 1.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

A M

E N

D M

E N

T

/0

/0

W

2Q R

R

_P la ns -0

E-100
E-101
E-102
E-103
E-104
E-105
E-106
E-107
E-600
E-610
E-625
E-626

File details come from the government source that posted it. Updated .