W912QR22R0035_Specs_Vol2-0000.pdf
PDF 4 MB Posted
- Attached to
- Transient Training Brigade Headquarters, Ft. McCoy, WI Federal contract opportunity
- Solicitation number
- W912QR22R0035
About this file
This document provides specifications for construction of a Transient Training Brigade Headquarters at Fort McCoy, Wisconsin. The project involves construction of facilities including barracks, headquarters, dining facilities, and other supporting structures. Divisions of the specifications cover areas such as concrete, masonry, metals, wood, thermal and moisture protection, doors and windows, finishes, equipment, furnishings, special construction, conveyance systems, utilities, and electrical systems. The specifications include requirements for products and materials, submittal procedures, quality assurance, delivery and storage, and execution. The Army Corps of Engineers is the contracting agency for this project.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912QR22R0035_Plans-0002.pdf | ||
| W912QR22R0035_Specs-0002.pdf | ||
| W912QR22R0035 AMDT 0001 - Final.pdf | ||
| Pre-Bid Site Visit Sign-in Sheet.pdf | ||
| W912QR22R0035_Plans-0000.pdf | ||
| W912QR22R0035_Specs_Vol1-0000.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation For Transient Training Brigade HQ Ft McCoy, WI
P2: 481860
Design-Bid-Build
Specifications - Vol. 1 of 2 (Div. 10-48) Certified Final Design
04 March 2022
W912QR22R0035
ARIMS: 200A
Disposition: Maintain for 15yrs after construction
W912QR22R0035_Specs_Vol2-0000
481860 Transient Training Brigade HQ Fort McCoy, WI
PROJECT TABLE OF CONTENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
00 80 00.00 06 SPECIAL PROVISIONS
DIVISION 01 - GENERAL REQUIREMENTS
01 32 01.00 06 PROJECT SCHEDULE
01 33 00 SUBMITTAL PROCEDURES
01 33 29.00 06 SUSTAINABILITY REPORTING
01 35 26.00 06 GOVERNMENT SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.15 10 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM)
01 45 04.10 06 CONTRACTOR QUALITY CONTROL
01 45 35 SPECIAL INSPECTIONS
01 46 00.00 06 TOTAL BUILDING COMMISSIONING
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19.00 06 TEMPORARY ENVIRONMENTAL CONTROLS AND PERMITS
01 74 19 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL
01 78 23 OPERATION AND MAINTENANCE DATA
DIVISION 03 - CONCRETE
03 30 00 CAST-IN-PLACE CONCRETE
DIVISION 04 - MASONRY
04 20 00 UNIT MASONRY
04 72 00.00 48 CAST STONE
DIVISION 05 - METALS
05 05 23.16 STRUCTURAL WELDING
05 12 00 STRUCTURAL STEEL
05 30 00 STEEL DECKS
05 40 00 COLD-FORMED METAL FRAMING
05 50 13 MISCELLANEOUS METAL FABRICATIONS
05 51 00 METAL STAIRS
05 52 00 METAL RAILINGS
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
06 61 16 SOLID SURFACING FABRICATIONS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS
07 13 53 ELASTOMERIC SHEET WATERPROOFING
07 21 13 BOARD AND BLOCK INSULATION
07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
07 27 19.01 SELF-ADHERING AIR BARRIERS
07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS
07 60 00 FLASHING AND SHEET METAL
07 61 14.00 20 STEEL STANDING SEAM ROOFING
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
PROJECT TABLE OF CONTENTS Page 1
CERTIFIED FINAL
DIVISION 08 - OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 11 16 ALUMINUM DOORS AND FRAMES
08 51 13 ALUMINUM WINDOWS
08 71 00 DOOR HARDWARE
08 81 00 GLAZING
08 91 00 METAL WALL LOUVERS
DIVISION 09 - FINISHES
09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 GYPSUM BOARD
09 30 10 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 ACOUSTICAL CEILINGS
09 62 38.00 06 STATIC-CONTROL FLOORING
09 65 00 RESILIENT FLOORING
09 90 00 PAINTS AND COATINGS
DIVISION 10 - SPECIALTIES
10 11 00.00 06 VISUAL DISPLAY UNITS
10 14 00.10 06 EXTERIOR SIGNAGE
10 14 00.20 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 22 39 FOLDING PANEL PARTITIONS
10 26 00 WALL PROTECTION
10 28 00.00 48 TOILET AND BATH ACCESSORIES
DIVISION 12 - FURNISHINGS
12 21 00 WINDOW BLINDS
DIVISION 14 - CONVEYING EQUIPMENT
14 24 23 HYDRAULIC PASSENGER ELEVATORS
DIVISION 21 - FIRE SUPPRESSION
21 13 13 WET PIPE SPRINKLER SYSTEMS, FIRE PROTECTION
DIVISION 22 - PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC
23 09 23.02 BACNET DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING
CONTROL SYSTEMS
23 11 25 FACILITY GAS PIPING
23 23 00 REFRIGERANT PIPING
23 30 00 HVAC AIR DISTRIBUTION
23 52 00 HEATING BOILERS
23 64 26 HOT WATER PIPING SYSTEMS
23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT
PROJECT TABLE OF CONTENTS Page 2
DIVISION 25 - INTEGRATED AUTOMATION
25 05 11.01 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS - FIRE
ALARM
25 05 11.02 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS - HVAC
DIVISION 26 - ELECTRICAL
26 08 00 APPARATUS INSPECTION AND TESTING
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 28 01.00 10 COORDINATED POWER SYSTEM PROTECTION
26 41 00 LIGHTNING PROTECTION SYSTEM
26 51 00 INTERIOR LIGHTING
26 56 00 EXTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 05 28.36 48 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
27 05 29.00 10 PROTECTIVE DISTRIBUTION SYSTEM (PDS) FOR SIPRNET
COMMUNICATION SYSTEMS
27 10 00.00 48 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM,
ADDRESSABLE
DIVISION 31 - EARTHWORK
31 00 00.00 06 EARTHWORK
31 05 22 GEOTEXTILES USED AS FILTERS
31 11 00 CLEARING AND GRUBBING
31 21 13 RADON MITIGATION
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 11 23 AGGREGATE BASE COURSE
32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 92 19 SEEDING
DIVISION 33 - UTILITIES
33 11 00 WATER UTILITY DISTRIBUTION PIPING
33 30 00 SANITARY SEWERAGE
33 40 00 STORM DRAINAGE UTILITIES
33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
33 82 00.00 48 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
DIVISION 48 - ELECTRICAL POWER GENERATION
48 14 00 SOLAR PHOTOVOLTAIC SYSTEMS
-- End of Project Table of Contents --
PROJECT TABLE OF CONTENTS Page 3
SECTION TABLE OF CONTENTS
DIVISION 10 - SPECIALTIES
SECTION 10 11 00.00 06
VISUAL DISPLAY UNITS
08/17
PART 1 GENERAL
1.1 REFERENCES
1.2 DEFINITIONS OR ADMINISTRATIVE REQUIREMENTS
1.3 SUBMITTALS
1.4 CERTIFICATIONS
1.4.1 Indoor Air Quality
1.4.1.1 Indoor Air Quality for Visual Display Products
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 WARRANTY
PART 2 PRODUCTS
2.1 MATERIALS
2.1.1 Glass Markerboards
2.1.2 Cork
2.1.2.1 Natural Cork
2.1.3 Aluminum
2.1.4 Glass
2.2 MARKERBOARD
2.3 TACKBOARDS
2.3.1 Cork
2.4 PROJECTION SCREEN
2.5 COLOR
PART 3 EXECUTION
3.1 PLACEMENT SCHEDULE
3.2 INSTALLATION
3.3 CLEANING
-- End of Section Table of Contents --
SECTION 10 11 00.00 06 Page 1
SECTION 10 11 00.00 06
VISUAL DISPLAY UNITS
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
ASTM INTERNATIONAL (ASTM)
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM C1048 (2018) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
ASTM F152 (1995; R 2009) Tension Testing of Nonmetallic Gasket Materials
CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)
CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS) Indoor Advantage
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
1.2 DEFINITIONS OR ADMINISTRATIVE REQUIREMENTS
The term visual display board when used herein includes presentation boards, marker boards, tackboards, board cases, display track system and horizontal sliding units; submit manufacturer's descriptive data and catalog cuts plus manufacturer's installation instructions, and cleaning and maintenance instructions. Visual display boards must be from
SECTION 10 11 00.00 06 Page 2 manufacturer's standard product line. Submit certificate of compliance signed by Contractor attesting that visual display boards conform to the requirements specified.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29.00 06 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-03 Product Data
Visual Display Board; G , RO
Projection Screen; G, RO
SD-04 Samples
Aluminum; G , RO
Porcelain Enamel; G , RO
Materials; G , RO
SD-07 Certificates
Indoor air quality for markerboards; S
Indoor air quality for tackboards; S
Indoor air quality for projection screen; S
1.4 CERTIFICATIONS
1.4.1 Indoor Air Quality
1.4.1.1 Indoor Air Quality for Visual Display Products
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party program that products meet the requirements of this Section. Provide current product certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver materials to the building site in the manufacturer's original unopened containers and store them in a clean dry area with temperature maintained above 50 degrees F. Stack materials according to manufacturer's recommendations. Visual display boards must be allowed to acclimate to the building temperature for 24 hours prior to installation.
SECTION 10 11 00.00 06 Page 3
1.6 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a one year period.
PART 2 PRODUCTS
2.1 MATERIALS
Submit section of core material showing the lamination of colored cork, natural cork, woven fabric, non-woven fabric, and vinyl wall covering.
Submit sample of hardwood and plastic laminate finish, and glass type.
Samples must be minimum 4 by 4 inches and show range of color.
2.1.1 Glass Markerboards
Provide marker board writing surface composed of glass 1/4 inch thick low iron tempered safety glass. Writing surface must be capable of supporting paper by means of magnets. Submit section showing glass color and mounting information.
2.1.2 Cork
Cork must be a continuous resilient sheet made from soft, clean, granulated cork relatively free from hardback and dust and bonded with a binder suitable for the purpose intended. The wearing surface must be free from streaks, spots, cracks or other imperfections that would impair its usefulness or appearance. The material must be seasoned, and a clean cut made not less than 1/2 inch from the edge must show no evidence of soft sticky binder.
2.1.2.1 Natural Cork
Material must be a single layer of pure grain natural cork without backing or facing. The color must be light tan. The cork sheet must have a tensile strength of not less than 40 psi when tested in accordance with
ASTM F152.
2.1.3 Aluminum
Aluminum frame extrusions must be alloy 6063-T5 or 6063-T6, conform to ASTM B221, and be a minimum 0.06 inches thick. Exposed aluminum must have an anodized, satin finish. Straight, single lengths must be used wherever possible. Joints must be kept to a minimum. Corners must be mitered and must have a hairline closure. Submit sections of frame, map rail, and chalktray, and two map hooks.
2.1.4 Glass
Glass must be comprised of tempered glass in accordance with ANSI Z97.1 and must conform to ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type I, Class I (clear), thickness as specified.
2.2 MARKERBOARD
Markerboard must have a glass writing, magnetic, surface and frameless.
Markerboard must be a factory assembled unit complete in one piece, without joints whenever possible. When markerboard dimensions require delivery in separate sections, components must be prefit at the factory, SECTION 10 11 00.00 06 Page 4 disassembled for delivery and jointed at the site. Frame must be invisible wall mounted. Dry erase markings must be removable with a felt eraser or dry cloth without ghosting. Each unit must come complete with an eraser and four different color compatible dry erase markers. The size must be as shown in the drawings . Provide markerboards that meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type).
2.3 TACKBOARDS
Provide tackboards that meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type).
2.3.1 Cork
Tackboard must consist of a minimum 1/4 inch thick natural cork laminated to a minimum 1/4 inch thick hardboard, and must have an aluminum frame.
The size must be as shown in the drawings .
2.4 PROJECTION SCREEN
Recessed mount motorized projection screen must have 120V motor that is lubricated for life, quick reversal type, has overload protector, integral gears, and preset accessible limit switches. Recessed mount projection screens must have an operable closure door and access panel. Screen must be flame retardant, mildew resistant, and white matte . Bottom of screen fabric must be weighted with metal rod. Roller must be a rigid metal at least 5 inches in diameter mounted on sound absorbing supports. Motor will be end mounted or motor-in-roller design. Screen must have a 3 position control switch to stop or reverse screen at any point. The switch must be installed in a flush electrical box with cover plate, location(s) as shown on the electrical drawings. All conduit and wiring from the control switch to the projection screen must be furnished and installed by the Contractor. Ceiling recessed case must be extruded aluminum . Ceiling mounted case must be aluminum . Screen must be UL listed. The size must be as shown in the drawings . Provide projection screens that meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type).
2.5 COLOR
Finish colors for required items must be as indicated.
PART 3 EXECUTION
3.1 PLACEMENT SCHEDULE
Location and mounting height of visual display boards must be as shown on the drawings.
Mounting height is defined as distance from finished floor to top of the display board frame.
SECTION 10 11 00.00 06 Page 5
3.2 INSTALLATION
Do not install items that show visual evidence of biological growth.
Perform installation and assembly in accordance with manufacturer's printed instructions. Use concealed fasteners. Visual display boards must be attached to the walls with suitable devices to anchor each unit.
furnish and install trim items, accessories and miscellaneous items in total, including but not limited to hardware, grounds, clips, backing materials, adhesives, brackets, and anchorages incidental to or necessary for a sound, secure, complete and finished installation. Installation must not be initiated until completion of room painting and finishing operations. Visual display boards must be installed in locations and at mounting heights indicated. Visual display boards must be installed level and plumb, and if applicable doors must be aligned and hardware must be adjusted. Damaged units must be repaired or replaced as directed by the Contracting Officer.
3.3 CLEANING
Writing surfaces must be cleaned in accordance with manufacturer's instructions.
-- End of Section --
SECTION 10 11 00.00 06 Page 6
SECTION TABLE OF CONTENTS
DIVISION 10 - SPECIALTIES
SECTION 10 14 00.10 06
EXTERIOR SIGNAGE
08/17
PART 1 GENERAL
1.1 REFERENCES
1.2 GENERAL REQUIREMENTS
1.2.1 Character Proportions and Heights
1.3 SUBMITTALS
1.4 QUALIFICATIONS
1.5 DELIVERY AND STORAGE
1.6 WARRANTY
PART 2 PRODUCTS
2.1 GRAPHICS FOR EXTERIOR SIGNAGE SYSTEMS
2.1.1 Graphics
2.1.2 Messages
2.2 VINYL SHEETING FOR GRAPHICS
2.3 SHOP FABRICATION AND MANUFACTURE
2.3.1 Factory Workmanship
2.3.2 Dissimilar Materials
2.3.3 Shop Painting
2.4 COLOR, FINISH, AND CONTRAST
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Anchorage
3.1.2 Protection and Cleaning
3.2 FIELD PAINTED FINISH
-- End of Section Table of Contents --
SECTION 10 14 00.10 06 Page 1
SECTION 10 14 00.10 06
EXTERIOR SIGNAGE
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN WELDING SOCIETY (AWS)
AWS D1.1/D1.1M (2015; Errata 1 2015; Errata 2 2016) Structural Welding Code - Steel
ASTM INTERNATIONAL (ASTM)
ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
ASTM A653/A653M (2018) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM A924/A924M (2018) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
ASTM E84 (2018a) Standard Test Method for Surface Burning Characteristics of Building Materials
1.2 GENERAL REQUIREMENTS
All exterior signage must be provided by a single manufacturer. Exterior signage must be of the design, detail, sizes, types, and message content shown on the drawings, must conform to the requirements specified, and must be provided at the locations indicated. Submit exterior signage schedule in electronic media with spread sheet format. Spread sheet must include sign location, sign type, and message. Signs must be complete with lettering, framing as detailed, and related components for a complete installation. Each sample must consist of a complete sign panel with letters and symbols. Samples may be installed in the work, provided each sample is identified and location recorded. Submit three color samples for each material requiring color and 12 inch square sample of sign face color sample.
1.2.1 Character Proportions and Heights
Letters and numbers on indicated signs for handicapped-accessible buildings must have a width-to-height ratio between 3:5 and 1:1 and a
SECTION 10 14 00.10 06 Page 2 stroke-width-to-height ratio between 1:5 and 1:10. Characters and numbers on indicated signs must be sized according to the viewing distance from which they are to be read. The minimum height is measured using an upper case letter "X". Lower case characters are permitted.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29.00 06 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Approved Detail Drawings; G , RO
SD-03 Product Data
Modular Exterior Signage System
Installation
Exterior Signage; G , RO
Wind Load Requirements
SD-04 Samples
Exterior Signage; G , RO
SD-10 Operation and Maintenance Data
Protection and Cleaning; G , RO
1.4 QUALIFICATIONS
Signs, plaques, and dimensional letters must be the standard product of a manufacturer regularly engaged in the manufacture of the products. Items of equipment must essentially duplicate equipment that has been in satisfactory use at least 2 years prior to bid opening.
1.5 DELIVERY AND STORAGE
Materials must be wrapped for shipment and storage, delivered to the jobsite in manufacturer's original packaging, and stored in a clean, dry area in accordance with manufacturer's instructions.
1.6 WARRANTY
Manufacturer's standard performance guarantees or warranties that extend beyond a one year period must be provided.
SECTION 10 14 00.10 06 Page 3
PART 2 PRODUCTS
2.1 GRAPHICS FOR EXTERIOR SIGNAGE SYSTEMS
2.1.1 Graphics
Signage graphics must conform to the following:
b. Pressure sensitive precision cut vinyl letters must be provided.
2.1.2 Messages
See drawings for message content. Typeface: Helvetica medium . Type size as indicated.
2.2 VINYL SHEETING FOR GRAPHICS
Vinyl sheeting must be 5 to 7 year premium type and must be in accordance with the flammability requirements of ASTM E84 and must be a minimum 0.003 inch film thickness. Film must include a precoated pressure sensitive adhesive backing, Class 1, or positionable pressure sensitive adhesive backing, Class 3.
2.3 SHOP FABRICATION AND MANUFACTURE
2.3.1 Factory Workmanship
Work must be assembled in the shop, as far as practical, ready for installation at the site. Work that cannot be shop assembled must be given a trial fit in the shop to ensure proper field assembly. Holes for bolts and screws must be drilled or punched. Drilling and punching must produce clean, true lines and surfaces. Welding to or on structural steel must be in accordance with AWS D1.1/D1.1M . Welding must be continuous along the entire area of contact. Exposed welds must be ground smooth.
Exposed surfaces of work must have a smooth finish and exposed riveting must be flush. Fastenings must be concealed where practical. Items specified to be galvanized must be by hot-dip process after fabrication if practical. Galvanization must be in accordance with ASTM A123/A123M and ASTM A653/A653M , as applicable. Other metallic coatings of steel sheet must be in accordance with ASTM A924/A924M . Joints exposed to the weather must be formed to exclude water. Drainage and weep holes must be included as required to prevent condensation buildup.
2.3.2 Dissimilar Materials
Where dissimilar metals are in contact, or where aluminum is in contact with concrete, mortar, masonry, wet or pressure-treated wood, or absorptive materials subject to wetting, the surfaces must be protected with a coat of asphalt varnish or a coat of zinc-molybdate primer to prevent galvanic or corrosive action.
2.3.3 Shop Painting
Surfaces of miscellaneous metal work, except nonferrous metal, corrosion
SECTION 10 14 00.10 06 Page 4 resisting steel, and zinc-coated work, must be given one coat of zinc-molybdate primer or an approved rust-resisting treatment and metallic primer in accordance with manufacturer's standard practice. Surfaces of items to be embedded in concrete must not be painted. Upon completion of work, damaged surfaces must be recoated.
2.4 COLOR, FINISH, AND CONTRAST
Color must be selected from manufacturers standard colors. For buildings required to be handicapped-accessible, the characters and background of signs must be eggshell, matte, or other non-glare finish. Characters and symbols must contrast with their background - either light characters on a dark background or dark characters on a light background.
PART 3 EXECUTION
3.1 INSTALLATION
Signs, plaques, or dimensional letters must be installed in accordance with approved manufacturer's instructions at locations shown on the approved detail drawings; submit drawings showing elevations of each type of sign; dimensions, details, and methods of mounting or anchoring; shape and thickness of materials; and details of construction. A schedule showing the location, each sign type, and message must be included.
Circuits installed underground must conform to the requirements of Section 33 71 02.00 06 UNDERGROUND ELECTRICAL DISTRIBUTION. Steel conduits installed underground and illuminated signage mounted directly on buildings must be in conformance with the requirements of Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. Signs must be installed plumb and true at mounting heights indicated, and by method shown or specified. Signs mounted on other surfaces must not be installed until finishes on such surfaces have been completed. Submit manufacturer's installation instructions and cleaning instructions.
3.1.1 Anchorage
Anchorage and fastener materials must be in accordance with approved manufacturer's instructions for the indicated substrate. Anchorage not otherwise specified or indicated must include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood.
3.1.2 Protection and Cleaning
The work must be protected against damage during construction. Hardware and electrical equipment must be adjusted for proper operation. Glass, frames, and other sign surfaces must be cleaned in accordance with manufacturer's instructions. After signs are completed and inspected, cover all project identification, directional, and other signs which may mislead the public. Covering must be maintained until instructed to be removed by the Contracting Officer or until the facility is to be opened for business. Submit six copies of maintenance instructions listing routine maintenance procedures, possible breakdowns and repairs, and troubleshooting guides. The instructions must include simplified diagrams for the equipment as installed. Signs must be cleaned, as required, at time of cover removal.
SECTION 10 14 00.10 06 Page 5
3.2 FIELD PAINTED FINISH
Miscellaneous metals and frames must be field painted in accordance with Section 09 90 00.00 06 PAINTS AND COATINGS. Anodized metals, masonry, and glass must be protected from paint. Finish must be free of scratches or other blemishes.
-- End of Section --
SECTION 10 14 00.10 06 Page 6
SECTION TABLE OF CONTENTS
DIVISION 10 - SPECIALTIES
SECTION 10 14 00.20
INTERIOR SIGNAGE
08/20
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 EXTRA MATERIALS
1.4 QUALITY ASSURANCE
1.4.1 Samples
1.4.2 Detail Drawings
1.4.3 Sign Fabricator
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 WARRANTY
PART 2 PRODUCTS
2.1 ROOM IDENTIFICATION AND DIRECTIONAL SIGNAGE SYSTEM
2.1.1 Modular Sign Systems
2.1.2 Standard Room Signs
2.1.2.1 Tactile Letters, Symbols and Braille
2.1.3 Directional Signs
2.1.4 Message Inserts
2.1.5 Type of Mounting for Signs
2.1.6 Character Proportions and Heights
2.2 STAIR SIGNAGE
2.3 EXIT DOOR TACTILE SIGN
2.4 DOOR TAGS
2.4.1 Engraved Copy
2.5 PRESSURE SENSITIVE LETTERS
2.5.1 Fabrication
2.5.2 Size
2.6 MATERIALS
2.6.1 Aluminum Alloy Products
2.6.2 Anodic Coating
2.6.3 Organic Coating
2.6.4 Plastic Laminate Sheet
2.6.5 Fabrication and Manufacture
2.6.5.1 Factory Workmanship
2.6.5.2 Dissimilar Materials
2.6.6 Typeface
2.7 GRAPHICS
2.7.1 First Surface Copy Direct Print (Non-Tactile)
2.7.2 Photopolymer
2.7.3 Engraved Copy
2.8 COLOR, FINISH, AND CONTRAST
PART 3 EXECUTION
SECTION 10 14 00.20 Page 1
3.1 INSTALLATION
3.1.1 Anchorage
3.1.2 Protection and Cleaning
-- End of Section Table of Contents --
SECTION 10 14 00.20 Page 2
SECTION 10 14 00.20
INTERIOR SIGNAGE
08/20
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
AA PK-1 (2015) Pink Sheets: Designations and Chemical Composition Limits for Aluminum Alloys in the Form of Castings & Ingot
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 2604 (2017a) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels
AMERICAN WELDING SOCIETY (AWS)
AWS D1.2/D1.2M (2014; Errata 1 2014; Errata 2 2020) Structural Welding Code - Aluminum
ASTM INTERNATIONAL (ASTM)
ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM D635 (2018) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position
INTERNATIONAL CODE COUNCIL (ICC)
ICC A117.1 COMM (2017) Standard And Commentary Accessible and Usable Buildings and Facilities
ICC/ANSI A117.1 (2009) Accessible and Usable Buildings and Facilities
SECTION 10 14 00.20 Page 3
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2021) Life Safety Code
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Detail Drawings; G , RO
SD-03 Product Data
Room Identification And Directional Signage System; G , RO
Room Identification Sign with Patient Information; G , RO
Stair Signage; G , RO
Exit Door Tactile Sign; G , RO
Door Tags; G , RO
SD-04 Samples
Interior Signage; G , RO
Software; G , RO
Room Identification And Directional Signage System; G , RO
Room Identification Sign with Patient Information; G , RO
Stair Signage; G , RO
Exit Door Tactile Sign; G , RO
Building Directories; G , RO
SECTION 10 14 00.20 Page 4
Door Tags; G , RO
SD-10 Operation and Maintenance Data
Approved Manufacturer's Instructions; G , RO
Protection and Cleaning; G , RO
1.3 EXTRA MATERIALS
Provide 5 extra frames and extra stock of the following: BB2 and BB3 blank plates of each color and size for all sign types included in project.
Provide 20 paper inserts and laser print templates to support end-user printing copy copy of the software for user produced signs and inserts after project completion and equipment necessary for removal of signage parts and pieces.
1.4 QUALITY ASSURANCE
1.4.1 Samples
Submit interior signage samples of each of the following sign types showing typical quality, workmanship and color: all sign types included in project , Stair Signage, Exit Door Tactile Sign, Door Tags, , , , Pressure Sensitive Letters. Approved samples may be installed in the work, provided each sample is identified and location recorded.
1.4.2 Detail Drawings
Submit detail drawings showing elevations of each type of sign, dimensions, details and methods of mounting or anchoring, mounting height, shape and thickness of materials, and details of construction. Include a schedule showing the location, each sign type, and message.
1.4.3 Sign Fabricator
Sign Fabricator to follow room number strategies created by designer. The room numbering system to be reviewed and approved by the Contracting Officer and command end users during the shop drawing phase, and prior to fabrication.
1.5 DELIVERY, STORAGE, AND HANDLING
Package materials to prevent damage and deterioration during shipment, handling, storage and installation. Deliver products to the jobsite in manufacturer's original packaging and store in a clean, dry area in accordance with manufacturer's instructions.
1.6 WARRANTY
Provide manufacturer's warranty to repair or replace defective interior signage materials and workmanship for a period of 2 years from date of final acceptance of the work.
PART 2 PRODUCTS
2.1 ROOM IDENTIFICATION AND DIRECTIONAL SIGNAGE SYSTEM
Provide signs, plaques, directories, and dimensional building letters that
SECTION 10 14 00.20 Page 5 are standard products of manufacturers regularly engaged in the manufacture of such products that essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening. Obtain signage from a single manufacturer with edges and corners of finished letter forms and graphics true and clean.
2.1.1 Modular Sign Systems
Provide manufactured pre-engineered component-based sign system, consisting of a combination of aluminum extrusions and injection molded parts, pre-engineered and designed to create an updatable sign system that allows for easy and inexpensive updates and changes. Provide system with incremental widths and heights that permit the assembly of multiple inserts of variable size to create a single sign. Provide a tamper-resistant sign which requires a special tool to change inserts composed of rigid plastic for applied graphics . Provide continuous removable endcaps in square thick profile. Sign inserts are required to be side loading.
2.1.2 Standard Room Signs
Provide signs that include tactile letters, symbols and Braille for interior rooms or spaces where the sign is not likely to change over time. Tactile text descriptions are required for pictograms that are provided to identify a permanent room. Examples include interior signs that label restrooms, stairs, room numbers or letters, and room names.
These permanent room signs can include paper inserts for updatable information.
2.1.2.1 Tactile Letters, Symbols and Braille
Provide ADA compliant material per 36 CFR 1191 which is raised 1/32 inch from the first surface, has a minimum 5/8 inch in height and is an ADA acceptable font. The color of the tactile letters is required to contrast with the sign face color per ADA standards. The ADA required Braille has a minimum durometer reading of 90. All raised letters, numbers and symbols are to comply.
2.1.3 Directional Signs
Directional signs provide arrows with messages which point to critical destinations such as departments, offices, or other pertinent destinations. These can be a panel sign system with a series of permanently attached messages or a modular system with updatable inserts.
Directional signs have header panels with applied or direct print messages.
2.1.4 Message Inserts
Provide updatable message inserts covered with a clear matte 0.015 inch vinyl protective overlay. The insert is typeset message laser printed on paper card stock . Provide paper and software with message template for creating text and symbols for computers identified for Government production of paper inserts after project completion. Manufacturer is required to offer online ordering capabilities to facilitate and expedite ordering packages of replacement, color-coated paper inserts. Provide sliding inserts that slide horizontally exposing different graphic information as identified on the drawings.
SECTION 10 14 00.20 Page 6
2.1.5 Type of Mounting for Signs
Provide surface mounted signs mounted with countersunk mounting holes in plaques and mounting screws. Secure inserts in holders when captured by side profiles of extruded aluminum holders. Provide signs with aluminum ceiling/projecting mount attachment extrusion to secure to ceiling or wall surface, along with matting ceiling/projecting mount track extrusion for hanging, projecting, and double-sided signs. Provide mounting for ceiling/projecting mount attachment extrusion by mechanical fasteners, selected based on wall or ceiling conditions. Mount track extrusion hinges over width of mount attachment and secured with 3.5 by 0.06 mm (6-32 inch) by 6 mm (1/4 inch) cone point stainless steel set screws.
2.1.6 Character Proportions and Heights
Letters and numbers on signs conform to 36 CFR 1191 .
2.2 STAIR SIGNAGE
Provide signs on stairs serving three or more stories with special signage within the enclosure at each floor landing conforming to NFPA 101 .
Indicate the floor level, the terminus of the top and bottom of the stair enclosure, and the identification of the stair enclosure. Also, state the floor level of, and the direction to, exit discharge. Locate the signage inside the enclosure in a position that is visible when the door is in the open or closed position and install in conformance with 36 CFR 1191 .
Provide tactile for floor level designation in accordance with
ICC A117.1 COMM .
2.3 EXIT DOOR TACTILE SIGN
Provide tactile sign with the message EXIT at each exit door that requires an exit sign to conform with NFPA 101 . Sign tactile message is to comply with ICC/ANSI A117.1 .
2.4 DOOR TAGS
Provide one door tag plate for each room entry door. In size as indicated on drawings. Provide room number as determined by Contracting Officer.
2.4.1 Engraved Copy
Machine engrave letters, numbers, symbols, and other graphics into panel sign on face to produce precisely formed copy and sharp images, incised to uniform depth. Melamine plastic engraving stock used for ADA compliant graphic is three-ply lamination contrasting color core meeting ASTM D635.
2.5 PRESSURE SENSITIVE LETTERS
2.5.1 Fabrication
Ensure that vinyl letter edges and corners of finished letterforms and graphics are true and clean. Do not use letterforms and graphics with rounded positive or negative corners, nicked, cut, or ragged edges.
2.5.2 Size
Letter size: as indicated.
SECTION 10 14 00.20 Page 7
2.6 MATERIALS
2.6.1 Aluminum Alloy Products
Aluminum extrusions are at least 1/8 inch thick, and aluminum plate or sheet are at least 0.0508 inch thick. Extrusions conform to ASTM B221;
plate and sheet conforms to ASTM B209. Where anodic coatings are specified, alloy conforms to AA PK-1 alloy designation 514.0. Exposed anodized aluminum finishes are as shown. Welding for aluminum products conforms to AWS D1.2/D1.2M .
2.6.2 Anodic Coating
Anodized finish conforms to AA DAF45 as follows:
a. Clear (natural) designation AA-M10-C22-A31, Architectural Class II 0.4 mil or thicker.
b. Integral color anodized designation AA-M10-C22-A32, Architectural Class
0.4 to 0.7 mil.
c. Electrolytically deposited color-anodized designation AA-M10-C22-A34, Architectural Class II 0.4 to 0.7 mil.
2.6.3 Organic Coating
Organic coating conforms to AAMA 2604, with total dry film thickness not less than 1.2 mils.
2.6.4 Plastic Laminate Sheet
ANSI/NEMA LD 3 , general purpose HGS grade, 0.048 inch nominal thickness.
2.6.5 Fabrication and Manufacture
2.6.5.1 Factory Workmanship
Holes for bolts and screws are drilled or punched. Drilling and punching produces clean, true lines and surfaces. Exposed surfaces of work have a smooth finish; exposed riveting is flush. Conceal fastenings where practicable.
2.6.5.2 Dissimilar Materials
Where dissimilar metals are in contact, protect surfaces prevent galvanic or corrosive action.
2.6.6 Typeface
ADA-ABA compliant font for Room Signs.
2.7 GRAPHICS
Provide signage graphics for modular signs to the following:
2.7.1 First Surface Copy Direct Print (Non-Tactile)
Message may be applied to panel using a direct print process. Original art is defined as artwork that is a first generation reproduction of the
SECTION 10 14 00.20 Page 8 specified art. Provide clean edges and corners.
2.7.2 Photopolymer
Integral graphics and Braille achieved by photomechanical stratification processes. Provide photopolymer used for ADA compliant graphics of the type that has a minimum durometer reading of 90. Tactile graphics are raised 1/32 inch from the first surface of plaque by photomechanical stratification process.
2.7.3 Engraved Copy
Machine engrave letters, numbers, symbols, and other graphics into panel sign on face to produce precisely formed copy and sharp images, incised to uniform depth. Melamine plastic engraving stock used for ADA compliant graphic is three-ply lamination contrasting color core meeting ASTM D635.
2.8 COLOR, FINISH, AND CONTRAST
Provide color as indicated; colors listed are not intended to limit the selection of equal colors from other manufacturers. Finish of eggshell, matte, or other non-glare finish for all signs as required in handicapped-accessible buildings.
PART 3 EXECUTION
3.1 INSTALLATION
Install signs plumb and true and in accordance with approved manufacturer's instructions at locations shown on the detail drawings .
Submit operating instructions outlining the step-by-step procedures required for system operation. The instructions include simplified diagrams for the system as installed, the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. Provide each set permanently bound with a hard cover. The following identification must be inscribed on the covers: "OPERATING AND MAINTENANCE INSTRUCTIONS", name and location of the facility, name of the Contractor, and contract number. Submit in accordance with Section 01 78 23 OPERATING AND MAINTENANCE DATA. Mounting height and mounting location complies with 36 CFR 1191 . Install required blocking. Do not install signs on doors or other surfaces until finishes on such surfaces have been installed. Signs installed on glass surfaces are installed with matching blank back-up plates in accordance with manufacturer's instructions.
Do not install items that show visual evidence of biological growth.
3.1.1 Anchorage
Provide anchorage in accordance with approved manufacturer's instructions. Anchorage not otherwise specified or shown includes slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood. Provide exposed anchor and fastener materials compatible with metal to which applied with matching color and finish.
a. Signs mounted to painted gypsum board surfaces must be removable for painting maintenance.
SECTION 10 14 00.20 Page 9
b. Mount signs to lay-in ceiling grids with clip connections to ceiling tees.
c. Install signs mounted on metal surfaces with magnetic tape.
d. Install signs mounted on fabric surfaces with hook and loop tape or pin mount.
e. Install signs to workstation panels with panel clips.
3.1.2 Protection and Cleaning
Protect the work against damage during construction. Adjust hardware and electrical equipment for proper operation. Clean glass, frames, and other sign surfaces at completion of signage installation in accordance with the manufacturer's written instructions.
-- End of Section --
SECTION 10 14 00.20 Page 10
SECTION TABLE OF CONTENTS
DIVISION 10 - SPECIALTIES
SECTION 10 21 13
TOILET COMPARTMENTS
08/20
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 CERTIFICATIONS
1.3.1 Indoor Air Quality
1.3.1.1 Laminated Plastic and Solid Phenolic Products
1.4 REGULATORY REQUIREMENTS
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 WARRANTY
PART 2 PRODUCTS
2.1 SYSTEM REQUIREMENTS
2.2 MATERIALS
2.2.1 Solid Polyethylene Panels (Finish 5)
2.2.2 Homogenous Filled Acrylic (Finish 6)
2.2.3 Sound-Deadening Cores
2.2.4 Anchoring Devices and Fasteners
2.2.5 Brackets
2.2.6 Hardware and Fittings
2.2.6.1 General Requirements
2.2.6.2 Finishes
2.2.7 Door Hardware
2.2.7.1 Hinges
2.2.7.2 Latch and Pull
2.2.7.3 Coat Hooks
2.3 PARTITION PANELS AND DOORS
2.3.1 Toilet Enclosures
2.3.2 Urinal Screens
2.4 CEILING-HUNG PARTITIONS
2.5 FLOOR-ANCHORED PARTITIONS
2.6 OVERHEAD-BRACED PARTITIONS
2.7 PILASTER SHOES
2.8 HARDWARE
2.9 COLORS AND FINISHES
2.9.1 Colors
2.9.2 Finishes
2.9.2.1 Finishes No. 4, No 4A and No. 5
2.9.2.2 Finish No. 6
PART 3 EXECUTION
3.1 PREPARATION
3.2 METAL PARTITION FABRICATION
3.3 INSTALLATION
SECTION 10 21 13 Page 1
3.4 CEILING-HUNG PARTITIONS
3.5 FLOOR-ANCHORED PARTITIONS
3.6 OVERHEAD-BRACED PARTITIONS
3.7 FINAL ADJUSTMENT
3.8 CLEANING
-- End of Section Table of Contents --
SECTION 10 21 13 Page 2
SECTION 10 21 13
TOILET COMPARTMENTS
08/20
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
ASTM INTERNATIONAL (ASTM)
ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
ASTM A167 (2011) Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip
ASTM A336/A336M (2018) Standard Specification for Alloy Steel Forgings for Pressure and High-Temperature Parts
ASTM A385/A385M (2020) Standard Practice for Providing High-Quality Zinc Coatings (Hot-Dip)
ASTM B36/B36M (2018) Standard Specification for Brass Plate, Sheet, Strip, and Rolled Bar
ASTM B86 (2018) Standard Specification for Zinc and Zinc-Aluminum (ZA) Alloy Foundry and Die Castings
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM D570 (1998; E 2010; R 2010) Standard Test Method for Water Absorption of Plastics
ASTM D638 (2014) Standard Test Method for Tensile Properties of Plastics
ASTM D696 (2016) Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30 degrees C and 30
SECTION 10 21 13 Page 3 degrees C With a Vitreous Silica Dilatometer
ASTM D2583 (2013a) Indentation Hardness of Rigid Plastics by Means of a Barcol Impressor
ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM G21 (2015) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
CSA GROUP (CSA)
CSA B45.5-17/IAPMO Z124 (2017; Errata 2017; Errata 2018) Plastic Plumbing Fixtures
INTERNATIONAL CODE COUNCIL (ICC)
ICC A117.1 COMM (2017) Standard And Commentary Accessible and Usable Buildings and Facilities
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates
NSF INTERNATIONAL (NSF)
NSF/ANSI 51 (2012) Food Equipment Materials
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS) Indoor Advantage
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
CID A-A-60003 (Basic) Partitions, Toilet, Complete
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification
SECTION 10 21 13 Page 4 identifies the office that will review the submittal for the Government.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Fabrication Drawings
Installation Drawings; G , RO
SD-03 Product Data
Cleaning and Maintenance Instructions
Colors And Finishes
Painted Metal
Sound-Deadening Cores
Anchoring Devices and Fasteners
Hardware and Fittings
Brackets
Door Hardware
Pilaster Shoes
Finishes; G, _____
SD-04 Samples
Colors and Finishes; G RO
Hardware and Fittings
Anchoring Devices and Fasteners
SD-07 Certificates
Warranty
Indoor air quality for solid phenolic, black core partitions and screens; S
1.3 CERTIFICATIONS
1.3.1 Indoor Air Quality
1.3.1.1 Laminated Plastic and Solid Phenolic Products
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party program that products meet the requirements of this Section. Provide current product
SECTION 10 21 13 Page 5 certification documentation from certification body.
1.4 REGULATORY REQUIREMENTS
Comply with to ICC A117.1 COMM code for access for the handicapped operation of toilet compartment door and hardware.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver materials in the manufacturer's original unopened packages with the brand, item identification, and project reference clearly marked.
Store components in a dry location that is adequately ventilated; free from dust, water, other contaminants, and damage during delivery, storage, and construction.
1.6 WARRANTY
Provide manufacturer's warranty to repair or replace defective materials and workmanship for a period of 25 years from date of final acceptance of the work.
PART 2 PRODUCTS
2.1 SYSTEM REQUIREMENTS
Provide a complete and usable toilet partition system, including toilet enclosures, room entrance screens, urinal screens, system of panels, hardware, and support components. Furnish the partition system from a single manufacturer, with a standard product as shown in the most recent catalog data. Submit Fabrication Drawings for toilet partitions and urinal screens consisting of fabrication and assembly details to be performed in the factory. Submit manufacturer's Cleaning and Maintenance Instructions in accordance with Section 01 78 23 OPERATIONS AND
MAINTENANCE DATA.
2.2 MATERIALS
2.2.1 Solid Polyethylene Panels (Finish 5)
Provide high density polyethylene (HDPE) suitable for exposed application.
Waterproof, non-absorbent and graffiti resistant textured surface with a Flame Spread Index of 75 or less, and a Smoke Developed Index of 450 or less.
2.2.2 Homogenous Filled Acrylic (Finish 6)
Cast, 100 percent acrylic solid polymer material composed of acrylic polymer, mineral fillers, and pigments that meets the following minimum performance requirements.
PROPERTY REQUIREMENT
(min. or max.)
TEST PROCEDURE
Tensile Strength 4000 psi (max.) ASTM D638
Hardness 55-Barcol Impressor (min.) ASTM D2583
SECTION 10 21 13 Page 6
PROPERTY REQUIREMENT
(min. or max.)
TEST PROCEDURE
Thermal Expansion .000023 in/in/degrees F (max.) ASTM D696
Boiling Water Surface Resistance
No Change ANSI/NEMA LD 3
High Temperature Resistance
No Change ANSI/NEMA LD 3
Impact Resistance (Ball Drop) ANSI/NEMA LD 3
1/4 inch sheet 36 inches, 1/2 lb ball, no failure
1/2 inch sheet 140 inches, 1/2 lb ball, no failure
3/4 inch sheet 200 inches, 1/2 lb ball, no failure
Mold and Mildew Growth No growth ASTM G21
Bacteria Growth No growth ASTM G21
Liquid Absorption (Weight in 24 hrs.)
0.1 percent max. ASTM D570
Flammability ASTM E84
Flame Spread 25 max.
Smoke Developed 30 max.
Sanitation "Food Contact" approval NSF/ANSI 51
2.2.3 Sound-Deadening Cores
Provide sound deadening consisting of treated kraft paper honeycomb cores with a cell size of not more than 1 inch. Provide resin-material content weighing not less than 11 percent of the finished core weight. Face expanded cores on both sides with kraft paper.
2.2.4 Anchoring Devices and Fasteners
Provide steel anchoring devices and fasteners hot-dipped galvanized after fabrication, in conformance with ASTM A385/A385M and ASTM A123/A123M .
Conceal all galvanized anchoring devices.
2.2.5 Brackets
Provide two-ear panel wall brackets, T-style, 1 inch stock. Provide stirrup style panel-to-pilaster brackets.
2.2.6 Hardware and Fittings
2.2.6.1 General Requirements
Provide hardware for the toilet partition system that complies with CID A-A-60003 for the specified type and style of partitions. Provide hardware finish highly resistant to alkalis, urine, and other common
SECTION 10 21 13 Page 7 toilet room acids. Comply with 36 CFR 1191 of latching devices and hinges for handicap compartments; provide stainless steel devices and hinges with door latches that operate without either tight grasping or twisting of the wrist of the operator. Submit three samples of each item, including anchoring devices and fasteners. Approved hardware samples may be installed in the work if properly identified.
Material…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .