W912QR20B0019Plans-0003.pdf

PDF 5 MB Posted

Attached to
Rebuild Test Structures at Lima, OH Federal contract opportunity
Solicitation number
W912QR20B0019
Issued by
Department of the Army Corps of Engineers Engineering District Louisville

About this file

This document provides details for an Invitation for Bid for the Rebuild Test Structures project at Lima, Ohio. The project includes construction of a new concrete mobility test slope that is 108' long by 80' wide with a 20' center path and 24' high, and a new water fording pit that is 152' long by 26'6" wide with a 16' path for tanks. The project also includes new access drives, grading, drainage, domestic water and sanitary sewer utilities. Demolition of existing structures is required. The bid due date is TBD and will be awarded as a firm-fixed-price contract to a small business. The selected contractor must be registered in the Joint Certification Program and have a SAM registration as an eligible U.S. company with U.S. citizen employees. The point of contact is provided for any questions.

View the file

Other files for this federal contract opportunity

Other files attached to Rebuild Test Structures at Lima, OH, newest first.
File Type Posted
Bid Opening Results.pdf PDF
W912QR20B0019-0004.pdf PDF
W912QR20B0019Specs-0003.pdf PDF
W912QR20B0019-0002.pdf PDF
US Certification Letter.docx DOCX document
W912QR20B0019Specs-0001.pdf PDF
Site Visit Roster Sheet.pdf PDF
W912QR20B0019Plans-0000.pdf PDF
W912QR20B0019Specs-0000.PDF PDF
US Certification Letter.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T

P

T

P

E

V.P.

CONC. PVMT.

CONC.

PVMT.

A

S

P

H

A

L

T

P

V

M

T

A

S

P

H

A

L

P

V

M

T

CONC. PVMT.

ASPHALT PVMT.

CONC. PVMT.

CONC. PVMT.

CONC. PVMT.

GRAVEL PVMT.

CONC.

PVMT.

B.M. #2

LP 8

LP 9

LP 10

LP 12

LP 13

LP 14

LP

LP 16

LP 17

LP 18

LP 20

LP21

LP22

TRAV PT.

#102

S D

S D

E x

C

E x

C

M P

GRAVEL PVMT.

GRAVEL

PVMT.

GAS PUMPS

AND CAT

WALK

A S

P H

A

M

T

SOIL BORING #1

SOIL BORING #2

SOIL BORING #3

INV: 868.71

B O

R I N

G

L A

Y O

U

A

N

U S

A

R M

Y

C

O R

S

O

F

E

N G

I N

E E

R S

J U

N E

T S

S T

B d w g

B-111

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

M

A N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

R

O

J E

C T

S

R E

B U

I

D

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T I

T H

K

N

G

J

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C

C A

T E

G O

Y

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s G e o t e c h T

S S

T B d w g u g a m

US Army Corps of Engineers

BORING LOCATION

30' 15' 0 30' 60' 90'

GRAPHIC SCALE: 1" = 30'

N

LEGEND

COORDINATE CHART

BORING # NORTHING EASTING

380,196.35 1,516,308.81

380,343.16 1,516,304.31

380,244.11 1,516,175.91

GENERAL BORING NOTES

1. REFER TO SHEET B-301 FOR BORING LOGS.

R

E V

I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

P

T

P

T

P

E

V.P.

T

P

C

O

E

T

P

E

EE

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

CONC. PVMT.

CONC. PVMT.

CONC.

PVMT.

A

S

P

H

A

L

T

P

V

M

T

C

O

N

M

T

A

S

P

H

A

L

T

P

V

M

T

A

S

P

H

A

M

T

CONC. PVMT.

C

O

N

M

T

A

S

P

H

A

M

T

A

S

P

H

A

M

T

A

S

P

H

A

M

T

C

O

N

M

T

ASPHALT PVMT.

CONC. PVMT.

CONC. PVMT.

CONC. PVMT.

GRAVEL PVMT.

CONC.

PVMT.

A

S

P

H

A

M

T

C

O

N

M

T

A

S

P

H

A

L T

P

V

M

T

C

O

N

M

T

B.M. #2

D

E

L

E

C

T

R

I

C

P

A

N

E

L

V

A

U

L

T

E

I

L

LP 2

LP4

LP5

LP6

LP

LP 8

LP 9

LP 10

LP 11

LP 12

LP 13

LP 14

LP

LP 16

LP 17

LP 18

LP

LP 20

LP21

LP22

LP23

W

W

E

X

W

A

T

A

N

TRAV PT.

#102

TRAV PT. #200

W

D

C

B

C

B

D

D

CO

D

C

B

C

B

S

D

S

D

S

D

GRAVEL PVMT.

GRAVEL

PVMT.

GAS PUMPS

AND CAT

WALK

C

O

N

M

T

C

O

N

M

T

A S

P H

A

M

T

C

O

N

M

T

M

P

C

M

P

C

M

P

C

SOIL BORING #1

SOIL BORING #2

SOIL BORING #3

O V

E R

A L L

D

E M

O L I T

I O

N

P

L A

N

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

D d w g

CD101

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

D d g a m

US Army Corps of Engineers

80' 40' 0 80' 160' 240'

GRAPHIC SCALE: 1" = 80'

N

CD112

CD111

A

LEGEND

CONCRETE PAVEMENT REMOVAL.

PHOTOGRAPH ID AND DIRECTION. REFER

TO SHEET CD701 FOR PHOTOGRAPHS.

GRAVEL PAVEMENT REMOVAL.

CONSTRUCTION LIMITS.

STEAM LINE REMOVAL.

MPC

GENERAL DEMOLITION NOTES

1. REFER TO SPECIFICATIONS FOR INFORMATION

REGARDING ASBESTOS, LEAD AND OTHER

CONTAMINANTS AND FOR INFORMATION REGARDING ANY

RECORD OF ENVIRONMENTAL CONSIDERATION (REC) OR

FINDING OF NO SIGNIFICANT IMPACT (FONSI).

2. GPS MONUMENTATION FOUND WITHIN CONSTRUCTION

LIMITS ARE NOT REQUIRED TO BE RELOCATED.

3. TEMPORARY CONSTRUCTION FENCING NOT REQUIRED

FOR ENTIRE CONSTRUCTION AREA. CONTRACTOR SHALL

PROVIDE TEMPORARY FENCING TO SECURE

CONTRACTOR LAYDOWN AREA. CONTRACTOR SHALL

PROVIDE SAFETY FENCING AT ANY OPEN EXCAVATION OR

AREA IN ACCORDANCE WITH SPECIFICATIONS.

4. CONTRACTOR TO DISPOSE OF ALL CONSTRUCTION

WASTE, DEMOLITION MATERIAL OR SPOIL MATERIAL OFF

PROPERTY AT NO ADDITIONAL COST TOT HE

GOVERNMENT. NO SPOIL AREA FOR SOILS OR MATERIALS

IS AVAILABLE AT JSMC. NO LANDFILL IS AVAILABLE FOR

CONTRACTOR USE AT JSMC. ALL CONSTRUCTION AND

DEMOLITION DEBRIS AND WASTE, INCLUDING ALL

REMOVED CONCRETE, MUST BE REMOVED AND DISPOSED

OF BY CONTRACTOR AT NO ADDITIONAL COST TO THE

GOVERNMENT, AND IN ACCORDANCE WITH ALL DISPOSAL

REGULATIONS.

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

P

T

P

E

V.P.

CONC. PVMT.

CONC.

PVMT.

A

S

P

H

A

L

T

P

V

M

T

A

S

P

H

A

M

T

CONC. PVMT.

ASPHALT PVMT.

CONC. PVMT.

CONC. PVMT.

CONC. PVMT.

GRAVEL PVMT.

CONC.

PVMT.

B.M. #2

LP 8

LP 9

LP 10

LP 12

LP 13

LP 14

LP

LP 16

LP 17

LP 18

LP 20

LP21

LP22

TRAV PT.

#102

S D

S D

E

C

E x

C

M P

GRAVEL PVMT.

GRAVEL

PVMT.

GAS PUMPS

AND CAT

WALK

A S

P H

A

M

T

SOIL BORING #1

SOIL BORING #2

SOIL BORING #3

INV: 868.71

N 379904.18

E 1516008.08

N 380504.32

E 1516314.90

N 380345.51

E 1516494.20

N 379904.18

E 1516494.20

N 380275.11

E 1516008.08

N 380119.83

E 1516417.13

N 380216.27

E 1516416.66

N 380119.83

E 1516288.02

N 380087.24

E 1516288.02

N 380087.23

E 1516255.93

N 379996.05

E 1516437.54

N 379995.67

E 1516307.51

N 379916.03

E 1516437.62

N 379915.65

E 1516307.51

N 380434.41

E 1516251.67

N 380401.81

E 1516276.06

N 380458.85

E 1516352.54

N 380491.73

E 1516328.29

N 380264.70

E 1516026.21

N 380232.10

E 1516050.60

N 380286.40

E 1516122.28

N 380318.72

E 1516097.81

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

D d w g

CD111

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

D d g a m

US Army Corps of Engineers

SHEET KEYNOTES

30' 15' 0 30' 60' 90'

GRAPHIC SCALE: 1" = 30'

N

LEGEND

MPC

GENERAL DEMOLITION NOTES

D E

M O

L I T

I O

N

P

L A

N

1. EXISTING CONCRETE TEST RAMP TO BE REMOVED.

REMOVE TO GRADE.

2. EXISTING CONCRETE PAVEMENT TO BE REMOVED.

3. EXISTING PVC STORM PIPE TO BE REMOVED.

4. EXISTING HEADWALL TO BE REMOVED.

5. EXISTING GRAVEL PAVEMENT TO BE REMOVED.

6. EXISTING LIGHT POLE TO BE REMOVED.

7. EXISTING BITUMINOUS PAVEMENT TO BE REMOVED.

PROVIDE CLEAN STRAIGHT SAW CUT PRIOR TO REMOVAL.

8. REMOVE TEST RAMP. REFER TO GRADING PLANS.

H

D

G

F

E

A

CONCRETE PAVEMENT REMOVAL.

PHOTOGRAPH ID AND DIRECTION. REFER

TO SHEET CD701 FOR PHOTOGRAPHS.

BITUMINOUS PAVEMENT REMOVAL.

CONSTRUCTION LIMITS.

STEAM LINE REMOVAL.

1. REFER TO SPECIFICATIONS FOR INFORMATION

REGARDING ASBESTOS, LEAD AND OTHER

CONTAMINANTS AND FOR INFORMATION REGARDING ANY

RECORD OF ENVIRONMENTAL CONSIDERATION (REC) OR

FINDING OF NO SIGNIFICANT IMPACT (FONSI).

2. GPS MONUMENTATION FOUND WITHIN CONSTRUCTION

LIMITS ARE NOT REQUIRED TO BE RELOCATED.

3. TEMPORARY CONSTRUCTION FENCING NOT REQUIRED

FOR ENTIRE CONSTRUCTION AREA. CONTRACTOR SHALL

PROVIDE TEMPORARY FENCING TO SECURE

CONTRACTOR LAYDOWN AREA. CONTRACTOR SHALL

PROVIDE SAFETY FENCING AT ANY OPEN EXCAVATION OR

AREA IN ACCORDANCE WITH SPECIFICATIONS.

4. CONTRACTOR TO DISPOSE OF ALL CONSTRUCTION

WASTE, DEMOLITION MATERIAL OR SPOIL MATERIAL OFF

PROPERTY AT NO ADDITIONAL COST TOT HE

GOVERNMENT. NO SPOIL AREA FOR SOILS OR MATERIALS

IS AVAILABLE AT JSMC. NO LANDFILL IS AVAILABLE FOR

CONTRACTOR USE AT JSMC. ALL CONSTRUCTION AND

DEMOLITION DEBRIS AND WASTE, INCLUDING ALL

REMOVED CONCRETE, MUST BE REMOVED AND DISPOSED

OF BY CONTRACTOR AT NO ADDITIONAL COST TO THE

GOVERNMENT, AND IN ACCORDANCE WITH ALL DISPOSAL

REGULATIONS.

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

P

C

O

E

T

P

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

A

S

P

H

A

M

T

C

O

N

M

T

A

S

P

H

A

M

T

C

O

N

M

T

A

S

P

H

A

L T

P

V

M

T

C

O

N

M

T

D

V

A

U

L

T

E

I

L

LP 2

LP4

LP5

W

W

W

W

W

W

W

E

X

W

A

T

A

N

TRAV PT. #200

W

W

W

W

D

C

B

C

B

D

D

CO

D

C

B

C

B

S

D

S

D

S

D

S

D

S

D

S

D

S

D

S

D

S

D

S

D

S

D

S D

S D

EX ST MH #3

TOP 864.15

12" SW INV 859.81

4" NE INV 862.01

EX CB #2

TOP 864.67

12" SW INV 862.32

4" E INV 863.07

EX CB #3

TOP 864.24

30" SE INV 858.29

24" NW INV 856.94

30" NE INV 856.84

EX ST MH #4

TOP 864.14

6" E INV 857.84

4" NW INV 859.09

EX ST MH #2

TOP 864.02

27" SE INV 858.92

12" SE INV 860.10

30" NW INV 858.87

EX CB #1

TOP 863.79

24" SW INV 860.54

12" NE INV 860.69

EX ST MH #1

TOP 863.74

21" SE INV 859.84

24" NE INV 859.69

27" NW INV 859.54

EX CB #4

TOP 860.26

12" N INV 859.16

EX CB #5

TOP 858.94

12" S INV 857.84

12" NE INV 857.84

8" NW INV 859.24

E

P

E

P

E

P

E

P

E x

C

P

P

E

A

Y

E

P

E

C

E

C

E x

C

E

C

E

P

E

P

E x

C

P S

L P

E

S

L

P

E

S

L

P

C

O

N

M

T

M

P

C

M

P

C

M

P

C

M

P

C

M

P

C

M

P

C

M

P

C

M

P

C

M

P

C

N 381296.39

E 1515922.19

N 381195.39

E 1516083.33

N 381163.42

E 1516113.85

N 381054.42

E 1516071.66

N 381015.14

E 1516018.40

N 380968.85

E 1516034.24

N 381079.71

E 1516038.55

N 381054.83

E 1516004.83

N 381265.94

E 1515837.30

N 381008.17

E 1515943.26

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

D d w g

CD112

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

D d g a m

US Army Corps of Engineers

SHEET KEYNOTES

1. EXISTING TEST PIT TO BE REMOVED. REMOVE

STRUCTURES, EQUIPMENT AND APPURTENANCES. CAP

ALL UTILITY LINES INCLUDING UTILITY LINES CONNECTING

TEST PIT AND EFV PIT.

2. EXISTING CONCRETE PAVEMENT TO BE REMOVED.

PROVIDE NEAT SAWCUT AT PAVEMENT TO REMAIN.

3. LIMITS OF REMOVAL.

4. HYDRANT AND BOLLARDS TO REMAIN.

5. EXISTING SIGN TO BE REMOVED.

6. EXISTING OVERHEAD STEAM LINE TO BE REMOVED TO

BUILDING 147. CAP AND DRIP BACK TO CONDENSATE AT

THE BUILDING. STEAM LINE SUPPORT STRUCTURES THAT

ARE NOT SERVING ANY OTHER UTILITIES SHALL ALSO BE

REMOVED. LOCATION OF STEAM LINE TO BE FIELD

VERIFIED PRIOR TO DEMOLITION.

7. OPTION: EXISTING EFV TEST PIT TO BE REMOVED.

REMOVE ALL STRUCTURES, EQUIPMENT AND

APPURTENANCES. REMOVE ALL UTILITY LINES

CONNECTING EFV TEST PIT AND OTHER TEST PIT TO BE

REMOVED. CAP ALL OTHER UTILITIES. REMOVE EXISTING

CONCRETE PAVEMENT AT EFV TEST PIT. PROVIDE NEAT

SAWCUT AT PAVEMENT TO REMAIN. OPTION TO BE

EXERCISED WITHIN 120 DAYS.

8. ALL EXISTING ELECTRICAL WIRING, CONDUIT AND

DEVICES FOR THE TEST PIT PUMP AND PUMP

CONTROLLER SHALL BE REMOVED. EXISTING ELECTRICAL

WIRING AND CONDUIT FEEDING THE PUMP CONTROLLER

SHALL BE DEMOLISHED BACK TO THE SPLICE LOCATION

ON THE POLE, LEAVING THE EXISTING LIGHTING CIRCUIT

IN PLACE.

30' 15' 0 30' 60' 90'

GRAPHIC SCALE: 1" = 30'

N

A

LEGEND

D E

M O

L I T

I O

N

P

L A

N

A

B

C

CONCRETE PAVEMENT REMOVAL.

PHOTOGRAPH ID AND DIRECTION. REFER

TO SHEET CD701 FOR PHOTOGRAPHS.

GRAVEL PAVEMENT REMOVAL.

CONSTRUCTION LIMITS.

STEAM LINE REMOVAL.

MPC

AREA OF EXISTING TEST PIT AND AREA OF EXISTING EFV TEST PIT IF

OPTION TO REMOVE EFV TEST PIT IS AWARDED SHALL BE BACKFILLED

TO MATCH SURROUNDING GRADE AFTER DEMOLITION. COMMON

EXCAVATIONS MAY BE USED FOR FILL MATERIAL. AREA SHALL BE

SEEDED AFTER BACKFILLING. REFER TO SPECIFICATIONS 31 00 00.00

06 EARTHWORK AND 32 92 19 SEEDING FOR MORE INFORMATION.

GENERAL DEMOLITION NOTES

1. REFER TO SPECIFICATIONS FOR INFORMATION

REGARDING ASBESTOS, LEAD AND OTHER

CONTAMINANTS AND FOR INFORMATION REGARDING ANY

RECORD OF ENVIRONMENTAL CONSIDERATION (REC) OR

FINDING OF NO SIGNIFICANT IMPACT (FONSI).

2. GPS MONUMENTATION FOUND WITHIN CONSTRUCTION

LIMITS ARE NOT REQUIRED TO BE RELOCATED.

3. TEMPORARY CONSTRUCTION FENCING NOT REQUIRED

FOR ENTIRE CONSTRUCTION AREA. CONTRACTOR SHALL

PROVIDE TEMPORARY FENCING TO SECURE

CONTRACTOR LAYDOWN AREA. CONTRACTOR SHALL

PROVIDE SAFETY FENCING AT ANY OPEN EXCAVATION OR

AREA IN ACCORDANCE WITH SPECIFICATIONS.

4. CONTRACTOR TO DISPOSE OF ALL CONSTRUCTION

WASTE, DEMOLITION MATERIAL OR SPOIL MATERIAL OFF

PROPERTY AT NO ADDITIONAL COST TOT HE

GOVERNMENT. NO SPOIL AREA FOR SOILS OR MATERIALS

IS AVAILABLE AT JSMC. NO LANDFILL IS AVAILABLE FOR

CONTRACTOR USE AT JSMC. ALL CONSTRUCTION AND

DEMOLITION DEBRIS AND WASTE, INCLUDING ALL

REMOVED CONCRETE, MUST BE REMOVED AND DISPOSED

OF BY CONTRACTOR AT NO ADDITIONAL COST TO THE

GOVERNMENT, AND IN ACCORDANCE WITH ALL DISPOSAL

REGULATIONS.

5. CONTRACTOR TO COORDINATE REMOVAL OF STEAM LINE

SUPPORT POLES, STRUCTURES AND ELECTRIC SERVICE LINES TO

TEST PITS AND TEST PIT AREA WITH CONTRACTING OFFICER

PRIOR TO REMOVAL. ELECTRICAL SERVICE LINES SHALL BE

REMOVED BACK TO EXISTING CONTROL AND/OR ELECTRICAL

PANEL. SITE LIGHTING POLES AND ELECTRIC SERVICE TO AREA

LIGHTS TO REMAIN.

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

P

T

P

T

P

E

V.P.

T

P

C

O

E

T

P

E

EE

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

CONC. PVMT.

CONC. PVMT.

A

S

P

H

A

L

T

P

V

M

T

C

O

N

M

T

A

S

P

H

A

L

T

P

V

M

T

CONC. PVMT.

C

O

N

M

T

A

S

P

H

A

M

T

A

S

P

H

A

M

T

A

S

P

H

A

M

T

C

O

N

M

T

ASPHALT PVMT.

CONC. PVMT.

CONC. PVMT.

GRAVEL PVMT.

CONC.

PVMT.

A

S

P

H

A

M

T

C

O

N

M

T

A

S

P

H

A

L T

P

V

M

T

E

L

E

C

T

R

I

C

P

A

N

E

L

E

I

L

LP 2

LP4

LP5

LP6

LP

LP 8

LP 9

LP 10

LP 11

LP 12

LP 13

LP 14

LP 16

LP 17

LP 18

LP

LP 20

LP21

LP22

LP23

D

C

B

C

B

D

D

CO

D

C

B

C

B

GRAVEL

PVMT.

GAS PUMPS

AND CAT

WALK

C

O

N

M

T

C

O

N

M

T

A S

P H

A

M

T

N

W

M

P

N

T

BIORETENTION

AREA

O V

E R

A L L

G

R A

A

I N

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

G d w g

CG101

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

G d g a m

US Army Corps of Engineers

80' 40' 0 80' 160' 240'

GRAPHIC SCALE: 1" = 80'

N

CG112

CG111

GENERAL GRADING NOTES

STORM SEWER MANHOLE.

CONCRETE HEADWALL.

STORM SEWER PIPE.

STORMWATER OUTLET STRUCTURE.

MAJOR CONTOUR.

MINOR CONTOUR.

CONSTRUCTION LIMITS.

LEGEND

1. EXISTING UTILITIES SHALL BE FIELD VERIFIED PRIOR TO

BEGINNING CONSTRUCTION.

2. CONTRACTOR TO DEVELOP AND PROVIDE SWPPP IN

ACCORDANCE WITH SPECIFICATION 01 57 19.00 06.

CONTRACTOR SHALL OBTAIN AND AND ALL NECESSARY

PERMITS AND INSTALL ALL REQUIRED BMPS PRIOR TO

GROUND DISTURBANCE ACTIVITIES.

18" SD

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

T

P

T

P

E

V.P.

CONC. PVMT.

A

S

P

H

A

L

T

P

V

M

T

CONC. PVMT.

ASPHALT PVMT.

CONC. PVMT.

CONC. PVMT.

GRAVEL PVMT.

CONC.

PVMT.

LP 8

LP 9

LP 10

LP 12

LP 13

LP 14

LP 16

LP 17

LP 18

LP 20

LP21

LP22

S D

S D

E x

C

M P

GRAVEL

PVMT.

GAS PUMPS

AND CAT

WALK

A S

P H

A

M

T

INV: 868.71

BIORETENTION

AREA

SD MH-02

TOP: 876.36

INV: 869.90

CB-01

TOP: 875.63

INV: 871.61

SD MH-01

TOP: 875.12

INV: 869.50

BIO-RET OUTLET

TOP: 874.06

INV: 870.20

HW-01

INV: 870.50

HW-02

INV: 870.50

SD MH-03

TOP: 877.47

INV: 874.64

SD MH-04

TOP: 877.69

INV: 874.23

SD MH-05

TOP: 877.91

INV: 874.57

SW TRENCH DRAIN

START INV: 876.16

END INV: 875.97

NE TRENCH DRAIN

START INV: 876.16

END INV: 875.97

I

N

N

M

P

N

T

G R

A D

E

A

A

A

N

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

G d w g

CG111

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

G d g a m

US Army Corps of Engineers

SHEET KEYNOTES

1. PROVIDE STORM SEWER PIPE. REFER TO DETAIL 2, SHEET

CU501.

2. PROVIDE STORM SEWER MANHOLE. REFER TO DETAIL 1,

SHEET CG501.

3. PROVIDE STORM SEWER CATCH BASIN. REFER TO SHEET

CG502.

4. PROVIDE CONCRETE HEADWALL. REFER TO DETAIL 2,

SHEET CG501.

5. PROVIDE STORMWATER OUTLET STRUCTURE, REFER TO

DETAIL 2, SHEET CG503.

6. PROVIDE LOW IMPACT BIORETENTION AREA. REFER TO

DETAIL 1, SHEET CG503.

7. PROVIDE STORM SEWER MANHOLE. CONNECT TO

EXISTING 24" STORM LINE. REFER TO DETAIL 1, SHEET

CG501.

8. PROVIDE TRENCH DRAIN. REFER TO DETAIL 1, SHEET

CG504.

9. PROVIDE 6" PERFORATED PIPE UNDERDRAINS. REFER TO

DETAIL 1, SHEET CG503.

STORM SEWER MANHOLE.

CONCRETE HEADWALL.

STORM SEWER PIPE.

STORMWATER OUTLET STRUCTURE.

MAJOR CONTOUR.

MINOR CONTOUR.

CONSTRUCTION LIMITS.

30' 15' 0 30' 60' 90'

GRAPHIC SCALE: 1" = 30'

N

LEGEND

18" SD

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

R.C.PIPE (BELL &

SPIGOT JOINT)

36" ROUND TRASH RACK

CLASS A CONCRETE

CLASS A CONCRETE

36" ROUND TRASH RACK

4" MIN CLASS A

CONCRETE

S

U

R

F

A

O

W

2-3" OF 3/8" GRAVEL

2-3" COVER

OVER PIPE

BIORETENTION AREA SHALL BE

LEVEL AND DEPRESSED A

MINIMUM OF 6" FROM THE

SURROUNDING GRADE

PIPE CATCH BASIN

WITH TRASH RACK.

REFER TO DETAIL

2, THIS SHEET

2" MIN

2" MIN

4'

36"

36" RISER

NON-WOVEN GEOTEXTILE

TO BE WRAPPED AROUND

CONNECTION

CAST IN PLACE

CONCRETE

ENCASEMENT

PERFORATED

PIPE

PROVIDE SPACER TO

MATCH INVERTS

AS NECESSARY

CLASS I BEDDING

TO SUPPORT

CONCRETE COLLAR

FINISH GRADE

V A

R I E

S

RCP PIPE

PERFORATED PIPE TO CONCRETE PIPE CONNECTION

LOW IMPACT BMP

PIPE CATCH BASIN WITH TRASH RACK

LOW IMPACT BMP

BIORETENTION BASIN

SUBGRADE COMPACTED 95%

OF LABORATORY MAXIMUM DENSITY

(ASTM D 1557)

PAVED AREA

12" MIN

NON-WOVEN

GEOTEXTILE

REFER TO

SPECIFICATIONS

#67 CRUSHED ROCK

SODSOD

TIE TO STORMDRAIN

SYSTEM.

4" FOR ALL BASINS

30" MIN. ENGINEERED SOIL

*SEE NOTE BELOW

6" PERFORATED PVC UNDERDRAIN

PIPES *PLACE PIPE WITH

PERFORATIONS AT THE

INVERT*

TIE UNDERDRAIN SYSTEM

PIPES INTO RISER. REFER

TO PLAN SHEETS FOR

LAYOUT

*BIORETENTION “ENGINEERED SOIL” LAYER SHALL BE MINIMUM 30” DEEP. THE SOIL MIX SHOULD BE UNIFORM AND FREE

OF STONES, STUMPS, ROOTS OR OTHER SIMILAR MATERIAL GREATER THAN 2 INCHES. IT SHOULD BE A HOMOGENOUS

SOIL MIX OF 75 TO 85 PERCENT BY VOLUME MEDIUM TO COARSE WASHED SAND (USDA SOIL TEXTURAL

CLASSIFICATION), 8 TO 10 PERCENT FINES (SILT AND CLAY), AND 5 TO 10 PERCENT ORGANIC MATTER (SUCH AS PINE

BARK FINES). ADDITIONALLY, THE PHOSPHORUS CONTENT OF THE SOIL MIX SHOULD BE LOW. IT IS THE

RESPONSIBILITY OF THE CONTRACTOR TO HAVE THE SOIL ANALYZED. THE P INDEX FOR BIORETENTION SOIL MEDIA

SHOULD ALWAYS RANGE BETWEEN 10 AND 30. THE P INDEX IS AN EXTREMELY IMPORTANT DESIGN ELEMENT. CELLS

THAT ARE CONSTRUCTED OF HIGH P-INDEX SOILS CAN EXPORT PHOSPHORUS.

NOTE: CUT SOIL FROM THE PROJECT SITE OR SOIL FROM THE BORROW PIT MAY NOT BE USED FOR THE ENGINEERED

SOIL FOR THE BIORETENTION BASINS

THE MEDIA SHOULD BE TESTED TO DETERMINE AN ACTUAL DRAINAGE RATE AFTER PLACEMENT. THE PERMEABILITY

SHOULD FALL BETWEEN 1 AND 6 INCHES PER HOUR, WITH 1-2 INCHES PER HOUR BEING PREFERRED. AS A RULE OF

THUMB, USING THE ABOVE-SPECIFIED MEDIA, THE INFILTRATION RATES SHOULD BE APPROXIMATELY 2 IN/HR AND 1

IN/HR FOR 8% AND 10% FINES, RESPECTIVELY.

REFER TO PLANS FOR FINISH GRADES.

**#67 CRUSHED ROCK LAYER SHALL BE 24" DEEP FOR ALL BIORETENTION BASINS.

INTERNAL

WATER

STORAGE

** SEE NOTE

BELOW

V A

R I E

S

M

I N

M

I N

DETAIL

NOT TO SCALE

CG111

DETAIL

NOT TO SCALE

TYP

DETAIL

NOT TO SCALE

CG111

G R

A D

E

A

A

T

A I L S

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

G d w g

CG503

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

G d g a m

US Army Corps of Engineers

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

2" (MIN) FOUNDATION ON BASE

10" (MIN)

D + 24" * (MIN.)

SLOTTED TRENCH DRAIN

6"-8" THICK TRENCH WALL

NOTE:

1.

2.

3.

4.

CONCRETE PAVEMENT

(SEE NOTE 4 BELOW)

BACKFILL PER

FAA AC 150/5370-10D,

ITEM D-702

PROVIDE SLOTTED TRENCH DRAIN TO

SUPPORT M1A2 ABRAMS TRACKED VEHICLE.

MAX SLOT WIDTH 2".

TRENCH DRAIN AND GRATE SHALL CONVEY

10 YR. STORM EVENT (0.33 CFS).

REFER TO DETAIL 1, SHEET CS501 FOR ADDITIONAL

INFORMATION ON NEW PAVEMENT SECTION.

DETAIL

NOT TO SCALE

TYP

2"

MIN

MAX 2"

WIDE SLOT

G R

A D

E

A

A

T

A I L S

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

G d w g

CG504

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

G d g a m

US Army Corps of Engineers

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

P

T

P

E

V.P.

CONC. PVMT.

A

S

P

H

A

L

T

P

V

M

T

CONC. PVMT.

ASPHALT PVMT.

CONC. PVMT.

CONC. PVMT.

GRAVEL PVMT.

CONC.

PVMT.

B.M. #2

LP 8

LP 9

LP 10

LP 12

LP 13

LP 14

LP 16

LP 17

LP 18

LP 20

LP21

LP22

TRAV PT.

#102

GRAVEL

PVMT.

GAS PUMPS

AND CAT

WALK

A S

P H

A

M

T

N 380119.83

E 1516417.13

N 379996.05

E 1516437.54

N 379995.67

E 1516307.51

N 379916.03

E 1516437.54

N 379915.65

E 1516307.51

130'

150'

N

M

P

N

T

R

R

R 30'

R

R

R

R

R15'

N 380086.85

E 1516199.81

N 380087.24

E 1516288.02

N 380119.83

E 1516288.02

N 380317.29

E 1516416.17

N 380429.99

E 1516367.31

N 380376.15

E 1516295.18

N 380378.47

E 1516293.39

N 380206.80

E 1516069.67

N 380261.39

E 1516141.22

N 380260.89

E 1516141.60

N 380310.50

E 1516301.53

N 380236.11

E 1516204.84

N 380268.04

E 1516325.88

N 380201.83

E 1516239.82

N 380327.57

E 1516307.32

CONTRACTOR

LAYDOWN

AREA

N 380234.88

E 1516186.85

L A

Y O

A

N

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

S d w g

CS111

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

S d g a m

US Army Corps of Engineers

SHEET KEYNOTES

1. PROVIDE CONCRETE SIDEWALK. REFER TO DETAIL 1,

SHEET CS502.

2. PROVIDE NEW TEST PIT. REFER TO STRUCTURAL

DRAWING S-111.

3. PROVIDE NEW TEST RAMP. REFER TO STRUCTURAL

DRAWING S-112.

4. PROVIDE NEW CONCRETE PAVEMENT. REFER TO DETAIL

1, SHEET CS501.

5. PROVIDE NEW CONCRETE FILLED BOLLARD. REFER TO

DETAIL 8, SHEET CS501.

6. PROVIDE WIND CONE. REFER TO DETAIL 9, SHEET CS501.

7. CONTRACTOR LAYDOWN AREA AND DIMENSIONS ARE FOR

BIDDING PURPOSES ONLY. CONTRACTOR SHALL

COORDINATE LAYDOWN AREA WITH COR.

CONCRETE PAVEMENT.

CONSTRUCTION LIMITS.

30' 15' 0 30' 60' 90'

GRAPHIC SCALE: 1" = 30'

N

LEGEND

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

BOLLARD

18" DIA

M

I N

8" DIA. STEEL PIPE,

CONCRETE FILLED

PAINTED YELLOW

UNLESS OTHERWISE

NOTED

GRADE LINE

CS111

DETAIL

NOT TO SCALE

PROVIDE EXPANSION JOINT AT ALL LOCATIONS

WHERE CONCRETE ABUTS EXISTING OR NEW

CONCRETE STRUCTURES.

PROVIDE CONTRACTION JOINTS AS REQUIRED.

PROVIDE EXPANSION JOINTS AS REQUIRED.

1.

2.

3.

CONCRETE PAVEMENT NOTES:

*ODOT: OHIO DEPARTMENT OF

TRANSPORTATION STANDARD

SPECIFICATIONS CONSTRUCTION

OF TRANSPORTATION SYSTEMS

EXPANSION JOINT

TRANSVERSE

CONTRACTION JOINT

DOWELED CONSTRUCTION JOINT

EXPANSION JOINT CONTRACTION JOINT

CONSTRUCTION JOINT

5/8" 5/8"

16"

D

D

D

D

5' MIN

¼

9"

12" RAW SUBGRADE

COMPACTED TO 90% OF

LABORARY MAXIMUM

DENSITY (ASTM D 1557)

12" AGGREGATE BASE COURSE

CONFORMING TO ODOT

CONSTRUCTION AND MATERIALS

SPECIFICATION SECTION 305 AND

TABLE 703.01-1 FOR NO. 57 OR 67.

PROVIDE #4

REINFORCEMENT

12" O.C.E.W.

9" ODOT CONCRETE, SECTION 450*,

CLASS QC 2 (4,500 PSI)

TURN EDGE DOWN WHERE

ABUTTING BITUMINOUS PAVEMENT

AND NO CURB. AT FREE EDGE,

THICKEN EDGE AS SHOWN ON

EXPANSION JOINT DETAIL

JOINT FILLER

BACKER

MATERIAL

POURED

JOINT SEALER

PAVEMENT

SURFACE

POURED

JOINT SEALER

PAVEMENT

SURFACE

BACKER

MATERIAL

JOINT

BOTTOM

INITAL

SAWCUT

OR INSERT

CRACK

PAVEMENT

SURFACE

POURED

JOINT SEALER

BACKER

MATERIAL

BUTTED JOINT

3/4" DIA. SMOOTH

DOWEL @ 24" SPA

PAINT AND OIL

ONE END OF DOWEL

EXISTING

PAVEMENT

DRILL AND

GROUT

CS111

CS501

CS501

CS501

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

CS501

CS501

CS501

CS501

CS501

CS501

CONCRETE PAVEMENT

3,500 PSI

CONCRETE (TYP)

NOTE: TOP TO BE PRECAST

OR CAST IN PLACE. NOT

HAND FORMED.

PROVIDE EXPANSION

JOINT WHEN PLACED

IN RIGID PAVEMENT.

REFER TO DETAIL 3,

SHEET CS501.

12" AGGREGATE BASE COURSE

CONFORMING TO ODOT

CONSTRUCTION AND MATERIALS

SPECIFICATION SECTION 304 AND

703.17.

WIND CONE

1' x 4' ORANGE

FABRIC WIND CONE

2" ALUMINUM POLE

CS111

DETAIL

NOT TO SCALE

RIGID FRAME

3/4" ALUMINUM POLE

M

I N

I M

U M

L A

Y O

T

A I L S

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

S d w g

CS501

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

S d g a m

US Army Corps of Engineers

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

C

E

C

E

CONCRETE SIDEWALK ADJACENT TO WALL

2% MAX.

NOTES:

PROVIDE CONTRACTION (SAWED)

JOINTS AT INTERVALS NOT IN EXCESS

OF 6' O.C.

EXPANSION JOINTS SHALL BE PLACED

AS SHOWN ON THE PLANS OR AT 24'

INTERVALS IF NOT SHOWN.

SIDEWALK ADJACENT TO BUILDING TO

HAVE MINIMUM TRANSVERSE SLOPE OF

1% AWAY FROM BUILDING.

1/2 " EXPANSION JOINT MATERIAL AT ALL

LOCATIONS WHERE NEW CONCRETE ABUTS

EXISTING OR NEW STRUCTURES AND AT

ALL CHANGES IN DIRECTION OF SIDEWALK.

1.

2.

3.

4.

JOINT AND FINISH

CONCRETE SIDEWALK @ TURF OR

FLUSH WITH PAVEMENT AREAS

CONTRACTION JOINTCE EXPANSION JOINT

REFER TO DETAIL 2,

SHEET CS501

REFER TO DETAIL 4,

SHEET CS501

*ODOT: OHIO DEPARTMENT OF

TRANSPORTATION STANDARD

SPECIFICATIONS CONSTRUCTION

OF TRANSPORTATION SYSTEMS

S

I

D

E

W

A

L

K

WIDTH VARIES

SEE PLANS

WIDTH VARIES

SEE PLANS

3/8"

1/8" TO 1/4"

M

I N

4" WIDE, SMOOTH

TROWELED PERIMETER

CONTRACTION JOINT

EXPANSION JOINT

FLUSH AT

PAVED AREAS

12" RAW SUBGRADE COMPACTED

TO 90% OF LABORARY MAXIMUM

DENSITY (ASTM D 1557)

3/4" CHAMFER

IN TURF AREAS

FINISH GRADE

TURF AREAS

6"x6" W2.9xW2.9 WWF

4" ODOT GROUP II GRADED

AGGREGATE BASE, SECTION 815*

3/4" CHAMFER

IN TURF AREAS

FINISH GRADE

TURF AREAS

6"x6" W2.9xW2.9 WWF

4" ODOT GROUP II GRADED

AGGREGATE BASE, SECTION 815*

12" RAW SUBGRADE COMPACTED

TO 90% OF LABORARY MAXIMUM

DENSITY (ASTM D 1557)

1/4" PREMOLDED

JOINT FILLER

PREMOLDED

JOINT FILLER

CS111

DETAIL

NOT TO SCALE

LOOP END CORNER RETURN

MAX. SPACING

BETWEEN POSTS

1'-0"

SPLICE

CORNER ELL

TYPICAL SIDE MOUNT CONNECTION TYPICAL TOP MOUNT CONNECTION

NOTE 7

EXPANSION

JOINT

1 3/8"

STAINLESS STEEL

SIDE-MOUNT BRACKET

WITH FOUR (4) 3/8" DIA

STAINLESS STEEL

ANCHORS

STAINLESS STEEL

BASE FLANGE WITH

FOUR (4) 3/8" DIA

STAINLESS STEEL

ANCHORS

1. GUARDRAILS AND HANDRAILS SHALL BE THE PRODUCT OF A COMPANY NORMALLY ENGAGED IN THE

MANUFACTURE OF PIPE RAILING. RAILING SHALL BE SHOP ASSEMBLED IN LENGTHS NOT TO EXCEED 24

FEET FOR FIELD ERECTION.

2. THE HANDRAIL SHALL BE MADE OF PIPES JOINED TOGETHER WITH COMPONENT FITTINGS. SAMPLES OF

ALL COMPONENTS, BASES, TOE PLATE AND PIPE SHALL BE SUBMITTED FOR APPROVAL AT THE REQUEST

OF THE ENGINEER. COMPONENTS THAT ARE POP-RIVETED OR GLUED AT THE JOINTS WILL NOT BE

ACCEPTABLE. ALL COMPONENTS MUST BE MECHANICALLY FASTENED WITH STAINLESS STEEL

HARDWARE.

3. RAILINGS SHALL BE 1 1/2" SCHEDULE 40 STEEL PIPE CONFORMING TO ASTM A53/A53M. POSTS SHALL BE

1 1/2" SCHEDULE 80 STEEL PIPE OF THE SAME ALLOY. POST SPACING SHALL BE A MAXIMUM OF 6'-0".

4. GUARDRAILS AND HANDRAILS SHALL BE DESIGNED TO WITHSTAND A 200 LB CONCENTRATED LOAD

APPLIED IN ANY DIRECTION AND AT ANY POINT ON THE TOP RAIL. GUARDRAILS AND HANDRAILS SHALL

ALSO BE DESIGNED TO WITHSTAND A UNIFORM LOAD OF 50 LB/FT APPLIED HORIZONTALLY TO THE TOP

RAIL. UNIFORM LOADS ARE NOT TO BE APPLIED SIMULTANEOUSLY WITH THE CONCENTRATED LOADS.

5. THE MANUFACTURER SHALL SUBMIT CALCULATIONS FOR APPROVAL AT THE REQUEST OF THE

ENGINEER. TESTING OF BASE CASTINGS OR BASE EXTRUSIONS BY AN INDEPENDENT LAB OR

MANUFACTURER'S LAB (IF MANUFACTURER'S LAB MEETS THE REQUIREMENTS OF THE ALUMINUM

ASSOCIATION) WILL BE AN ACCEPTABLE SUBSTITUTE FOR CALCULATIONS. CALCULATIONS WILL BE

REQUIRED FOR APPROVAL OF ALL OTHER DESIGN ASPECTS.

6. POSTS SHALL NOT INTERRUPT THE CONTINUATION OF THE TOP RAIL AT ANY POINT ALONG THE RAILING, INCLUDING CORNERS AND END TERMINATIONS (OSHA 1910.23). THE TOP SURFACE OF THE TOP RAILING

SHALL BE SMOOTH AND SHALL NOT BE INTERRUPTED BY PROJECTED FITTINGS.

7. THE MID-RAIL AT A CORNER RETURN SHALL BE ABLE TO WITHSTAND A 200 LB LOAD WITHOUT

LOOSENING. THE MANUFACTURER IS TO DETERMINE THIS DIMENSION FOR THEIR SYSTEM AND PROVIDE

PHYSICAL LABORATORY TESTS TO CONFIRM COMPLIANCE.

8. CONCRETE ANCHORS SHALL BE STAINLESS STEEL TYPE 303 OR 304 AND SHALL BE FURNISHED BY THE

HANDRAIL MANUFACTURER. THE ANCHOR DESIGN SHALL INCLUDE THE APPROPRIATE REDUCTION

FACTORS FOR SPACING AND EDGE DISTANCES IN ACCORDANCE WITH THE MANUFACTURER'S

PUBLISHED DATA.

9. THE PIPE SHALL BE PLASTIC-WRAPPED. THE PLASTIC WRAP IS TO BE REMOVED AFTER ERECTION.

10. SURFACES IN CONTACT WITH CONCRETE, GROUT OR DISSIMILAR METALS WILL BE PROTECTED WITH A

COAT OF BITUMINOUS PAINT, MYLAR ISOLATORS OR OTHER APPROVED MATERIAL.

11. RAILINGS AND POSTS SHALL BE PAINTED SAFETY YELLOW.

6'-0" 1'-0"

TYPICAL HANDRAIL

CS502

CS502

CS502

CS502

CS111

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

L A

Y O

T

A I L S

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

C

S d w g

CS502

W Q

R B

M M

A Y

E R

M S

O U

T H

J L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s C i v i l T

S S

T C

S d g a m

US Army Corps of Engineers

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

N T

R A

C T

Y D

O W

N

A

R E

A

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

J U

T S

S T

G d w g

G-202

W Q

R B

M

M

A Y

E R

M

S

O U

T H

J

L O

C K

W F

O Y

A N

S I

D

CERTIFIED FINAL

J O

I N

T

S

Y S

T E

N

U F

A C

T U

R I N

G

C

E N

T E

R

L I M

A

O

H I O

L I M

A

S

O

J E

C T

S

R E

B U

I

S

T

S

T R

U C

T U

R E

S

P

D

R

M

A R

T

T H

N

G

A

C E

L O

U I S

V I L L E

K

Y

L O

U I S

V I L

S

T R

I C

T

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s T e s t

S t r u c t u r e s

C

A D

B

I M

S h e e t s G e n T

S S

T G d g a m

US Army Corps of Engineers

CONTRACTOR

LAYDOWN AREA

NOTES:

1. CONTRACTOR SHALL COORDINATE SIZE AND LOCATION OF CONTRACTOR LAYDOWN AREA WITH

CONTRACTING OFFICER.

2. CONTRACTOR RESPONSIBLE FOR SECURING CONTRACTOR LAYDOWN AREA.

3. CONTRACTOR SHALL RESTORE CONTRACTOR LAYDOWN AREA TO PRE-CONSTRUCTION

CONDITIONS AT END OF PROJECT.

R E

V I S

C

O R

D A

N C

E

W

I T

H

A

M E

N D

M E

W

2Q R

B0

9-

2Q R

B0

9-

2Q R

B0

9-

2Q R

B0

9-

B-111.pdf
Sheets and Views
B-111 BORING LAYOUT PLAN
CD101.pdf
Sheets and Views
CD101 OVERALL DEMOLITION PLAN
CD111.pdf
Sheets and Views
CD111 DEMOLITION PLAN
CD112.pdf
Sheets and Views
CD112 DEMOLITION PLAN
CG101.pdf
Sheets and Views
CG101 OVERALL GRADE AND DRAIN
CG111.pdf
Sheets and Views
CG111 GRADE AND DRAIN PLAN
CG503.pdf
Sheets and Views
CG503 GRADE AND DRAIN DETAILS
CG504.pdf
Sheets and Views
CG504 GRADE AND DRAIN DETAILS
CS111.pdf
Sheets and Views
CS111 LAYOUT PLAN
CS501.pdf
Sheets and Views
CS501 LAYOUT DETAILS
CS502.pdf
Sheets and Views
CS502 LAYOUT DETAILS
G-202.pdf
Sheets and Views
G-202 CONTRACTOR LAYDOWN AREA
Test Structure As-built drawings.pdf
20
34
40

File details come from the government source that posted it. Updated .