Starkville_Floor_Plan_-_FIO_-_DRAFT.pdf
PDF 255 KB Posted
- Solicitation number
- W912QR19B0008
About this file
Starkville Floor Plan - DRAFT
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Starkville_Elevation_Plan_-_FIO_-_DRAFT.pdf | ||
| Starkville_Aerial_Site_Plan_-_FIO_-_DRAFT.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REF.
FEC FEC
FE
C
FE
C
FECFEC
FE
C
FE
C
FE
C
FE
C
FEC
FE
C
FEC
FEC
FE
C
FECFECFE
C
FE
C
FEC
932 SF
CORRIDOR
102A
108 SF
296 SF
CHAIR STORAGE
2994 SF
ASSEMBLY
120 SF
OFFICE 1
120 SF
OFFICE 2
120 SF
OFFICE 3
120 SF
OFFICE 4
117 SF
FACILITY
MANAGER
1809 SF
UNIT COMMON
237 SF
TEAM ROOM
237 SF
TEAM ROOM
146 SF
OFFICE 5
120 SF
OFFICE 6
1038 SF
MEN
604 SF
WOMEN
1065 SF
FITNESS
443 SF
CLASSROOM
1617 SF
MAINTENACE BAY
88 SF
TR
289 SF
BREAK ROOM
98 SF
LACTATION
79 SF
FAMILY RR
254 SF
FAMILY SUPPORT
357 SF
ELECTRICAL
426 SF
CLASSROOM
982 SF
MECHANICAL
80 SF
EF
538 SF
ARMS VAULT
189 SF
ARMORER ROOM
140 SF
CONTROL WASTE
83 SF
FLAMMABLE
STORAGE
222 SF
TOOL PARTS /
TOOL STORAGE
143 SF
SHOP OFFICE
150 SF
SUPPLY OFFICE
104 SF
COMPRESSOR
199 SF
STAGING
297 SF
RETENTION
158 SF
ENTRY
245 SF
FAC MAINT
STORAGE
129 SF
TRAINING AIDS
STORAGE
441 SF
SIMULATOR
64 SF
STORAGE
448 SF
CLASSROOM
69 SF
STORAGE
99 SF
JANITOR
193 SF
ALCOVE
89 SF
TER
49 SF
STORAGE
119 SF
FAC CONTROL /
SAFE ROOM
120 SF
OFFICE 7
249 SF
CORRIDOR
106 SF
CORRIDOR
3' - 0" 17' - 4" 3' - 4" 5' - 4" 6' - 0" 5' - 4" 6' - 0" 49' - 4" 6' - 0" 5' - 4" 6' - 0" 5' - 4" 6' - 0" 8' - 8" 26' - 0" 7' - 4" 6' - 0" 10' - 0" 6' - 0"
3'
4" 6'
0"
5'
4" 6'
0"
5'
4" 6'
0"
6'
0"
6'
0"
6'
0"
B1 A-301
A1 A-301
28 SF
STORAGE
139 SF
CORRIDOR
D1 A-201
C1 A-201
A1 A-201
B1 A-201
3' - 4" 8' - 0" 6' - 4" 16' - 0"
3' - 4"
37' - 4" 6' - 4" 5' - 4" 6' - 0" 12' - 0" 6' - 0" 5' - 4" 6' - 4" 44' - 8"
3'
4" 4'
8"
6'
4" 8'
0"
6'
4" 4'
0"
6'
4"
309 SF
LOBBY
101CORRIDOR
102B
CORRIDOR
102C
CORRIDOR
102D
1 2 3 4 5 6 7 8 9 10
A
B
C
D
F
G
E
/2
1/ 2"
3'
1/
4"
0'
0"
12' - 0" 21' - 0" 21' - 0" 28' - 2" 27' - 2" 28' - 0" 35' - 0" 33' - 8" 20' - 0"
226' - 0"
0'
0"
4.1
SAT CANOPY
A3 A-302
KITCHEN TRAILER SLAB
6'
0"
3'
4"
32' - 8" 3' - 4" 6' - 0"
6'
0"
3'
4" 3'
4"11
6'
0"
2.9
D4 A-301
UNIT STORAGE
A1 A-302
M
AT
C H
LI
N
E A-
M
AT
C H
LI
N
E A-
MATCHLINE A-103
MATCHLINE A-103
C1 A-302
MECH
EQUIP
PAD
MECH
EQUIP
PAD
WITHOUT BID
OPTION #13/32" = 1'-0"A1 FIRST FLOOR PLAN
SCALE: = 1'-0"
1 2 3 4 5
A
B
C
D
SHEET OF
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
IS
SU
E
D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
N
BE
R
D
AT
E D
ES
C
R
IP
TI
O
N M
AR
K
US Army Corps of Engineers ® Louisville District
TE
TR
A
TE
C H
, I N
C
W ar rin gt on W ay Lo ui sv ille , K
Y
Ph on e (5
) 5
-5
Fa x
(5
) 5
-5 w w w
.te tra te ch
.c om
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
W
2Q R
-1 7-
D -0
3/32"
0 8 16 248
PLAN NORTH
AREA AAREA B
BID
OPTION
#1
KEY PLAN - COMPOSITE
6/ 4/
:1
6:
A M
BI
M
0-
2-
St ar kv ille A
R C
/S
AR
C _A
_v
.rv t
A-101
FINAL DESIGN SUBMITTAL - NOT
FOR CONSTRUCTION
57 183
C O
M
PO
SI
TE
P
LA
N
PR
O
JE
C
T
P R
O
JE
C T
PN
Q . B
IA
G
I
T.
H
O U
R
IG
AN
W . N
IE
PO
R T
JU
N E
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
ST
AR
KV
IL
LE
A R
C
FLOOR PLAN NOTES
1. REFER TO PARTITION TYPES ON SHEET A-505.
2. REFER TO FINISH SCHEDULE ON INTERIOR DRAWINGS
FOR FLOOR FINISH AND WALL FINISH.
3. REFER TO REFLECTED CEILING PLANS FOR CEILING
TYPES AND CEILING HEIGHTS ON SHEET A-105.
4. REFER TO FRAME TYPES FOR WINDOW & DOOR FRAME
TYPES SHOWN. SEE SHEET A-601.
5. REFER TO MECHANICAL, ELECTRICAL, AND
STRUCTURAL EQUIPMENT FOR DETAILS, EQUIPMENT
SHOWN FOR REFERENCE ONLY.
6. TYPICAL FIRST FLOOR ELEVATION TO BE 0'-0" UNLESS
NOTED OTHERWISE DATUM ELEVATION COORDINATE
WITH ACTUAL ELEVATIONS. REFER TO CIVIL DRAWINGS.
7. REFER TO SIGNAGE TYPES INDICATED ON SHEET
ITERIOR DRAWINGS.
8 ALL GWB PARTITIONS RECEIVE SOUND ATTENUATION
INSULATION UNO.
9 ALL PARTITION WALLS IN RESTROOMS, LOCKER ROOMS,
JANITORS CLOSETS AND AT DRINKING FOUNTAINS
SHALL BE MOISTURE / MOLD RESISTANT GWB.
10 ALL PARTITION WALLS SCHEDULED TO RECEIVE TILE
FINISH SHALL BE CEMENTUOUS BACKER BOARD.
11 PROVIDE PAINTED METAL ACCESS PANELS AT ALL
RESTROOMS AND LOCKER ROOM CHASE WALLS
12 ALL EXPOSED CORNERS ON INTERIOR PARTITION
WALLS TO RECEIVE FLOOR TO CEILING S.S. CORNER
GUARDS (TYPICAL AT ALL LOCATIONS THROUGHOUT)
FI
N
AL
D E S
IG
N
S U
BM
IT
TA
L
J
U N
E 1 9
File details come from the government source that posted it.