W912PP25R0006 Small Arms Storage Facility KAFB - AM 0004.pdf
PDF 18 MB Posted
- Solicitation number
- W912PP25R0006
About this file
This is Amendment 0004 to solicitation W912PP25R0006 for a Design-Bid-Build Small Arms Facility at Kirtland Air Force Base in Bernalillo County, New Mexico, issued by the U.S. Army Engineer District, Albuquerque Corps of Engineers.
The amendment makes two key changes: 1) Revises page 31 of 126 in Section 00 22 16 - Supplementary Instructions to Proposers, and 2) Updates drawing ES101.1 Electrical Site Plan to ES101.2 Electrical Site Plan. The amendment is effective March 5, 2025, and contractors are required to sign and return one copy to acknowledge receipt. The original solicitation date was January 22, 2025. The amendment does not extend the proposal due date.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by o
(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOU PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN RE amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not, is required to sign this document and return
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
FACILITY CODE
9A. AMENDMENT OF SOLICITATION
NO.
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of th
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRAC
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED I
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN IT
IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHA date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, rem
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTR
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract sub
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERIC
(Signature of Con
NSN 7540-01-152-8070
Previous edition unusable
W912PP
Design Bid Build, Small Arms Facility, Kirtland Air Force Base, Bernalillo County, New Me
1.This is Amendment No. 0004 to Solicitation No. W912PP25R0006. The following revisi specifications. All other provisions shall remain unchanged.
U.S. ARMY ENGINEER DISTRICT, ALBUQUERQUE
CORPS OF ENGINEERS
4101 JEFFERSON PLAZA, N.E.
ALBUQUERQUE, NEW MEXICO 87109-3435
See Item 6
J
W912PP25R0006
1 2
03/05/2025
01/22/2025
X ne of the following methods:
R ACKNOWLEDGMENT TO BE RECEIVED AT THE
JECTION OF YOUR OFFER. If by virtue of this telegram or letter makes reference to the solicitation copies to the issuing office.
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA FAR (48 CFR) 53.243 is amendment on each copy of the offer submitted;
TS/ORDERS.
N ITEM 14.
EM 14 ARE MADE IN THE CONTRACT ORDER NO.
NGES (such as changes in paying office, appropriation ains unchanged and in full force and effect.
16C. DATE SIGNED
ACTING OFFICER (Type or print) ject matter where feasible.)
A tracting Officer) xico.
ons shall be incorporated into the
W912PP25R0006
AMENDMENT No. 0004
2. SPECIFICATIONS: Delete the following listed pages and substitute the pages attached hereto. On the revised pages, for convenience, changes are emphasized by STRIKETHROUGH for deletions and UNDERLINE for additions from the previous issue. All portions of the revised (or new) pages shall apply whether or not changes have been indicated.
Delete Page Insert Page
Section 00 22 16 - Supplementary Instructions to Proposers, page 31 of
Section 00 22 16 - Supplementary Instructions to Proposers, page 31 of
3. DRAWING CHANGES: The following drawings have been revised and the sequence number changed to indicate such revision:
Delete Page Insert Page
ES101.1 Electrical Site Plan ES101.2 Electrical Site Plan
////////LAST ITEM////////
E
E
E
E
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE
E
CP
CP
SAN
SAN
SAN
SAN
SANN
SAN
SAN
SAN
SANANAA
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
CP
CP
W W W W W W W W W W W W W W W W W WWW W W W WW W W W W W W W W W
G G G G G G G G G G G G G G G G G G G G G
S S S
G
G G
G G
G
G G G
NN
G G
W W
W W
W W
W W
W W
W W W WW W W W
G G
G G
G
G W
W
WGG
W W
WWGG
ANNNNNNANANANANANNNNAANNNNNAAAAAAAAA
'-6
'-6 "6
'-6666
'-6
""6"""""66"6"66""66""""66""
EE
G
C G
G
E
B FD
A
A
COMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMM
EEEEEEEEEEEEEEEEEEEEEEEE
COMMCOMMCOMMCOMMCOMMCOMMCOMM COMM
COMM
COMM
COMM
COMM
C O
M M
C O
M M
COMM COMM
COMM
1. VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
2. ALL UNDERGROUND CONDUIT TO AND FROM THE NEW
FACILITY SHALL BE PVC COATED RGS, AT LEAST 50 FEET
FROM THE FACILITY. GROUND EACH END OF METALLIC UG
CONDUIT USING A 3/4" X 10' COPPER COATED STEEL
GROUND ROD.
3. ALL CONDUITS RUNNING UNDER ROADS ARE TO BE
CONCRETE ENCASED.
4. TRANSFORMER AND SECTIONALIZER TO BE PAINTED
WITH SHERMAN WILLIAMS #6099 (SAND DOLLAR) PAINT.
GENERAL NOTES
SHEET KEYNOTES
1. INTERCEPT EXISTING UNDERGROUND 4,160V PRIMARY
CONDUCTORS. CONDUCTORS ARE BETWEEN
TRANSFORMER T737 AND TRANSFORMER T733.
2. PROVIDE AND INSTALL A 4-WAY, 15KV, 200A,
SECTIONALIZER AT APPROXIMATE LOCATION SHOWN.
SECTIONALIZER MUST BE 50' MIN. FROM STORAGE
FACILITY. CONNECT NEW CONDUCTORS FROM T2 (T733)
TO SECTIONALIZER. CONNECT NEW CONDUCTORS FROM
T1 (T737) TO SECTIONALIZER. CONDUCTORS SHALL BE
15KV, 133% INSULATION, MV90. NEW CONDUCTOR AWG
TO MATCH EXISTING. PROVIDE NEW CONDUIT TO MATCH
EXISTING. FOR CONDUIT THAT WAS REMOVED TO INSTALL
CONDUCTORS.
3. PROVIDE AND INSTALL A DUAL FEED 45KVA 12,470V/4,160V
PRIMARY 208Y/120V SECONDARY, TRANSFORMER (T1) AT
APPROXIMATE LOCATION SHOWN. TRANSFORMER SHALL
BE 5 ' (MIN.) FROM FACILITY.
4. ROUTE (3), #1/0 AWG, 15KV, 133% INSULATION, MV90 FROM
SECTIONALIZER TO T3 AT NEW SMALL ARMS STORAGE
FACILITY. ROUTE, UNDERGROUND, IN 5", SCH-40 PVC
COATED, RGS WITH SCH-40 PVC COATED RSC ELBOWS.
SEE ES501 FOR DUCT BANK DETAILS.
5. REMOVE EXISTING DUCTBANK AND REINSTALL BETWEEN
HANDHOLES. INSTALL TOP OF CONCRETE ENCASEMENT
AT 36" (MIN.) BELOW FINISHED GRADE BETWEEN THESE
KEYED NOTES. PROVIDE HANDHOLES AND SPLICE
EXISTING CONDUCTORS BETWEEN INTO HANDHOLES.
6. DISCONNECT AND REMOVE EXISTING COMM LINE(S) FROM
BET AT BOTH ENDS. ABANDON EXISTING DIRECT BURIED
COMM LINE IN PLACE.
7. INSTALL NEW COMM LINES, AROUND NEW FACILITY.
MATCH EXISTING COMM LINE TYPE. RECONNECT TO BET.
DIRECT BURY 36" MIN. BELOW FINISHED GRADE. PROVIDE
CONCRETE ENCASED CONDUIT FOR COMM LINES UNDER
ROADS. MAINTAIN 12" OR GREATER DISTANCE FROM
POWER LINES FOR ENTIRE LENGTH OF CABLE.
8. PROVIDE AND INSTALL NEW SPLICE BOX FOR COMM
LINES. PROVIDE COMM LINE SURGE PROTECTION
DEVICES INSIDE SPLICE BOX.
9. PROVIDE TELEPHONE CONNECTION ON EXTERIOR OF
BUILDING. COORDINATE CONNECTION TYPE REQUIRED
WITH PHONE MANUFACTURER.
10. TELECOMM LINE IS TO CONNECT TO THE TELECOMM
CONNECTION FEEDING BUILDING 737. PENETRATE
THROUGH EXISTING WALL TO COMM ROOM. COORDINATE
CONNECTION AFTER FIELD VERIFICATION.
20' 40'0SCALE: 1"=20'
ELECTRICAL SITE PLANE1
PLAN
NORTH
1 2
KIRTLAND AMMO
BLDG. 737
BLDG. 733
5 5
~180 FEET
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
5/
/2
:3 6:
A
M
ES101.2
EL
EC
TR
IC
AL
S
IT
E
PL
AN
KI
R
TL
AN
D A
FB
A
LB
U
Q U
ER
Q
U E, N
EW
M
EX
IC
O
AL
BU
Q U
ER
Q
U E
D
IS
TR
IC
T
J
EF
FE
R
SO
N P
LA
ZA
N E
AL
BU
Q U
ER
Q
U E, N M
J.
G
EA
R
J.
P
R O
SP
ER
R . M
O G
H
AD
AM
JA
N
U
AR
Y
W
2P P2
5R
SO
LI
C
IT
AT
IO
N D
R
AW
IN
G
S
- N
O T
FO
R
C O
N
ST
R U
C
TI
O N
SM
AL
L
AR
M S
FA
C
IL
IT
Y
M H
M V2
K:
\k af b\
KA
\P ro je ct
D at a\ C
AD
_B
IM
\1
5_ El ec \K
A9 0E
S1
_2 .d w g
W
2P P-
XX
-X
-X
XX
X
U
SA
C E
SP
A
AM
C
LA
R
IF
IE
D C
O M
M C
O N
N
EC
TI
O
N P
O
IN
T, N
O
TE
S, A
D D
ED
H
AN
D
H O
LE
S.
2 2
AM
AD
D
ED
C
LA
R
IF
IC
AT
IO
N S
TO
K
EY
N
O
TE
S, R
EM
O
VE
D
F
LO
AT
IN
G E
LE
M
EN
TS
File details come from the government source that posted it. Updated .