W912PM23Q0032 - Cape Hattaras - Questions and Responses.xlsx

XLSX spreadsheet 16 KB Posted

Attached to
Cape Hatteras Piling Clusters Replacement
Solicitation number
W912PM24Q0032
Issued by

About this file

This document is a Questions and Responses sheet related to a forthcoming federal solicitation for the Cape Hatteras Piling Clusters Replacement project, Solicitation Number W912PM24Q0032.

The key details are as follows:

  • The project involves the replacement of piling clusters at Cape Hatteras.
  • A site visit is scheduled for 06/25/2024 at 9:00 a.m. ET, with RSVPs required by 06/21/2024.
  • Questions must be submitted by 2:00 p.m. ET on 06/25/2024.
  • The solicitation closing date is 07/08/2024 at 2:00 p.m. ET.
  • The contract will be awarded by the U.S. Army Corps of Engineers, Engineering District Wilmington.
  • The Questions and Responses sheet provides clarification on items such as required submittals, laydown and staging areas, handling of broken pilings, GPS coordinates, and requirements for marking the work area.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Site Visit Question's and Responses
7-Apr-23
Solicitation Number: W912PM24Q0032
Cape Hattaras Piling Clusters Replacement
Question #QuestionResponse
1Please clarify, is ITEM NO 0001 - Develop Engineering Plan, required for this projectProvide a Shop Drawing of the Pilings to be installed.
2Can the concrete area next to Pile Cluster 2 and adjacent grassed area be used as laydown area, work truck parking and temporary piling debris storageYes.
3Please designate a barge staging area for times not in use.The Coast Guard mentioned the use of the seawall to tie up a barge while not in use as long it is out of the way from any current Coast Guard operations.
4If piles break while removing, can they be cut off at mudline?Yes.
5Are there GPS coordinates for the locations where the new pile are to be driven? If the designated locations are where existing pile were cut off, what is the tolerance for placement?No. GPS Available Pilings are to be placed as close as possible to the current Center of the Piling Clusters.
6Will the contractor be required to place bouys or floating barrier to alert boaters of work area?Yes, due to the boat traffic in the area.
7Is there any riprap or other known obstructions in the anticipated new pile locations that may impact driving the new pile?We are not aware of any, but we cant be positive on that.
8
9
10
11
12
13