W912PM20B0011-0004-SF00012_drawings_20200811.pdf

PDF 20 MB Posted

Attached to
Renovate specified areas within the gym located at Ft Bragg, NC
Solicitation number
W912PM20B0011
Issued by

About this file

This solicitation is for renovation work at a gym located at Fort Bragg, North Carolina. The contractor shall demolish an existing wall and stairs to construct a new full second floor, including two enclosed spaces for storage and office/equipment. Windows will be installed on the south walls of the first and second floors. Modifications will be made to electrical, communications, HVAC and fire protection systems as needed. New LED light fixtures and fire alarm devices will be installed in the new spaces. The work must comply with ADA regulations to the greatest extent practical. Nearby occupied areas must be protected during construction.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FORT BRAGG, NORTH CAROLINA

DPW PROJECT NO: SF-00012-17

SOLICITATION NO:

CONTRACT NO:

100% SUBMITTAL

A N

S I

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L

E N

A M

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C T

N

O

C A

T E

G O

R Y

D

E

D E

S

I P

T I O

N

J O

N E

S

F

R A

N K

L

D

S

E

R A

L E

I G

H

N

C

F

A X

L I C

E N

F

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

R E

N O

V A

P

H Y

S I C

A L

T

H E

R A

A

E

A

B U

I L D

I N

G

O

M

S

O T

F

F O

B

A

G G

N

O R

R

O L I N

A

D E

P A

R T

M E

T

M

Y

F O

A

G G

N

O R

R

O L I N

A

D I R

E C

T O

R A

P

U B

L

W

R

K S

J U

L

INDEX OF DRAWINGS

SECTION SYMBOLS

BASIC DESIGN DATA

SHEET

NUMBER

SHEET

NUMBER

TITLE TITLE

SHEET

NUMBER

TITLE

ARCHITECTURAL

AD101 FIRST AND SECOND FLOOR PLANS - DEMOLITION

AD102 FIRST AND SECOND FLOOR REFLECTED CEILING PLANS - DEMOLITION

AE101 FIRST AND SECOND FLOOR PLANS - NEW WORK

AE102 FIRST AND SECOND FLOOR ENLARGED DIMENSION PLANS

AE103 FIRST AND SECOND FLOOR REFLECTED CEILING PLANS - NEW WORK

AE401 ENLARGED PLANS, STAIR PLANS, SECTIONS AND DETAILS

AE402 STAIR AND INTERIOR DETAILS

AE601 DOOR SCHEDULE, TYPES AND FRAMES

AE602 WINDOW TYPES AND FRAME DETAILS

AF601 ROOM FINISH SCHEDULE AND FINISH KEY

AQ601 FIRST AND SECOND FLOOR FURNITURE/EQUIPMENT PLANS

GENERAL

G-001 COVER SHEET

G-002 VICINITY MAP AND PROJECT LOCATION MAP

G-003 GENERAL CONSTRUCTION NOTES

G-004 GENERAL CONSTRUCTION NOTES

RENOVATE PHYSICAL THERAPY AREA,

BUILDING O190M, SOTF

MECHANICAL

M-001 MECHANICAL - GENERAL NOTES AND LEGENDS

MD101 MECHANICAL - FIRST FLOOR PLAN - DEMOLITION

MD102 MECHANICAL - SECOND FLOOR PLAN - DEMOLITION

MH101 MECHANICAL - FIRST FLOOR PLAN - NEW WORK

MH102 MECHANICAL - SECOND FLOOR PLAN - NEW WORK

M-501 MECHANICAL - DETAILS & SCHEDULES

ELECTRICAL

E-001 ELECTRICAL - GENERAL NOTES AND LEGENDS

E-002 ELECTRICAL - GENERAL NOTES AND LEGENDS

ED101 ELECTRICAL - FIRST FLOOR PLAN - DEMOLITION

ED102 ELECTRICAL - SECOND FLOOR PLAN - DEMOLITION

EP101 ELECTRICAL - FIRST FLOOR PLAN - POWER

EP102 ELECTRICAL - SECOND FLOOR PLAN - POWER

EL101 ELECTRICAL - FIRST FLOOR PLAN - LIGHTING

EL102 ELECTRICAL - SECOND FLOOR PLAN - LIGHTING

LIFE SAFETY

LS101 FIRST FLOOR LIFE SAFETY PLAN - CONSTRUCTION PHASE

LS102 SECOND FLOOR LIFE SAFETY PLAN - CONSTRUCTION PHASE

LS103 FIRST AND SECOND FLOOR PLANS - NEW WORK

STRUCTURAL

S001 GENERAL NOTES & DESIGN DATA

S002 SPECIAL INSPECTIONS

S003 SPECIAL INSPECTIONS

S101 FOUNDATION PLAN

S102 SECOND FLOOR PLAN

S201 ELEVATIONS

S501 TYPICAL FOUNDATION DETAILS

S502 TYPICAL CMU DETAILS

S520 TYPICAL FLOOR DETAILS

PLUMBING

P-001 PLUMBING - GENERAL NOTES AND ABBREVIATIONS

P-002 PLUMBING - SCHEDULE AND LEGEND

PD101 PLUMBING - FIRST FLOOR PLAN - DEMOLITION

PL121 PLUMBING - FIRST FLOOR PLAN - WASTE & VENT

PL122 PLUMBING - SECOND FLOOR PLAN - WASTE & VENT

PL131 PLUMBING - FIRST FLOOR PLAN - WATER

PL132 PLUMBING - SECOND FLOOR PLAN - WATER

G-001

C O

V E

R

S

H E

E T

M A

B

M A

B

T F

T F

FIRE PROTECTION

F-001 FIRE PROTECTION - GENERAL NOTES AND ABBREVIATIONS

FD101 FIRE ALARM - FIRST FLOOR PLAN - DEMOLITION

FD102 FIRE ALARM - SECOND FLOOR PLAN - DEMOLITION

FA101 FIRE ALARM - FIRST FLOOR PLAN

FA102 FIRE ALARM - SECOND FLOOR PLAN

FX101 FIRE PROTECTION - FIRST FLOOR PLAN - SPRINKLERS

FX102 FIRE PROTECTION - SECOND FLOOR PLAN - SPRINKLERS

F-501 FIRE PROTECTION - DETAILS

F-502 FIRE ALARM - DETAILS

F-601 FIRE ALARM - RISER DIAGRAM

EY101 ELECTRICAL - FIRST FLOOR PLAN - COMMUNICATIONS

EY102 ELECTRICAL - SECOND FLOOR PLAN - COMMUNICATIONS

E-501 ELECTRICAL - DETAILS

E-502 ELECTRICAL - DETAILS

E-503 ELECTRICAL - DETAILS

E-504 ELECTRICAL - DETAILS

E-601 ELECTRICAL - RISERS

E-602 ELECTRICAL - SCHEDULES

E-603 ELECTRICAL - SCHEDULES

E-604 TELECOMMUNICATIONS - RISER DIAGRAM

E-605 ACCESS CONTROLS - RISER DIAGRAM

SOLID WASTE

TRANSFER STATION

FORT BRAGG CANTONMENT

NOT TO SCALE

A N

S I

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L

E N

A M

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

P

T I O

N

J O

N E

S

F

R A

N K

L

S

R A

L E

I G

H

N

C

F

A X

L I C

E N

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

R E

N O

V A

Y

S I C

A L

T

H E

R A

E

A

B U

I L D

I N

G

O

M

S

O T

F

F O

A

G G

N

O R

R

O L I N

A

D E

P A

R T

M E

T

M

Y

F O

A

G G

N

O R

R

O L I N

A

D I R

E C

T O

R A

P

U B

L

R

K S

L

PROJECT LOCATION

G-002

V I C

I N

I T

Y

M

D

P R

O J E

L

C A

T I O

N

M

A P

M A

B

M A

B

T F

T F

CONTRACTOR

STAGING AREA

ACCESS TO

STAGING AREA

THRU SPINE

CORRIDOR

PROJECT

LOCATION

NOTE: ACTUAL STAGING

AREA LOCATION TO BE

COORDINATED W/ THE

GOVERNMENT

S I

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L

E N

A M

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

P

T I O

N

J O

N E

S

F

R A

N K

L

S

R A

L E

I G

H

N

C

F

A X

L I C

E N

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

R E

N O

V A

Y

S I C

A L

T

H E

R A

E

A

B U

I L D

I N

G

O

M

S

O T

F

F O

A

G G

N

O R

R

O L I N

A

D E

P A

R T

M E

T

M

Y

F O

A

G G

N

O R

R

O L I N

A

D I R

E C

T O

R A

P

U B

L

R

K S

L

G-003

G E

N E

R A

L

C

O N

S T

R U

C T

I O

N

N

O T

E S

M A

B

M A

B

T F

S I

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L

E N

A M

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

P

T I O

N

J O

N E

S

F

R A

N K

L

S

R A

L E

I G

H

N

C

F

A X

L I C

E N

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

R E

N O

V A

Y

S I C

A L

T

H E

R A

E

A

B U

I L D

I N

G

O

M

S

O T

F

F O

A

G G

N

O R

R

O L I N

A

D E

P A

R T

M E

T

M

Y

F O

A

G G

N

O R

R

O L I N

A

D I R

E C

T O

R A

P

U B

L

R

K S

L

G-004

G E

N E

R A

L

C

O N

S T

R U

C T

I O

N

N

O T

E S

M A

B

M A

B

T F

DESIGN CRITERIA – CODES AND SPECIFICATIONS

ALL CONSTRUCTION SHALL COMPLY AS APPROPRIATE WITH THE

FOLLOWING UNIFIED FACILITIES CRITERIA:

1. INTERNATIONAL BUILDING CODE 2015.

2. ACI318-14-BUILDING CODE REQUIREMENTS FOR STRUCTURAL

CONCRETE.

3. ACI301-16–SPECIFICATIONS FOR STRUCTURAL CONCRETE

FOR BUILDINGS.

4. ANSI/AISC 360-10–SPECIFICATION FOR STRUCTURAL STEEL

BUILDINGS.

5. ASCE/SEI 7-10–MINIMUM DESIGN LOADS FOR BUILDINGS AND

OTHER STRUCTURES.

7. SDI DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS,

AND ROOF DECKS–NO31

8. SDI DIAPHRAGM DESIGN MANUAL THIRD EDITION.

9. SJI STANDARD SPECIFICATIONS, LOAD TABLES AND WEIGHT

TABLES FOR STEEL JOISTS AND JOISTS GIRDERS 42ND

EDITION 2005.

10. UFC-3-301-01-STRUCTURAL ENGINEERING - 2012.

11. ACI 530-08 BUILDING CODE REQUIREMENTS FOR MASONRY

STRUCTURES.

DESIGN LOADS

DEAD LOAD

THE WEIGHT OF ALL PERMANENT CONSTRUCTION INCLUDING WALLS,

FLOORS, CEILINGS, ROOF CLADDING.

2ND FLOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 PSF

LIVE LOAD

2ND FLOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 PSF STAIR LANDING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 PSF

GEOTECHNICAL

THE DESIGN OF FOUNDATIONS IS BASED ON AN ALLOWABLE SOIL

BEARING PRESSURE OF 2,000 PSF.

A QUALIFIED GEOTECHNICAL ENGINEER SHALL VERIFY CONDITION

AND/OR ADEQUACY OF ALL SUBGRADES, FILLS AND BACKFILLS BEFORE

PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS, WALLS, FILLS,

BACKFILLS, ETC.

FOUNDATION DESIGN DATA

ALLOWABLE SOIL BEARING PRESSURE = 2,000 PSF

UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL

WEIGHT AND HAVE THE FOLLOWING MINIMUM 28-DAY COMPRESSIVE

STRENGTHS:

f'c W/C RATIO

FOUNDATIONS . . . . . . . . . . . . . 3,000 PSI 0.51 MAX

SLABS-ON-GRADE . . . . . . . . . . 4,000 PSI 0.45 MAX

SUSPENDED FLOOR SLAB . . . . . . . 3,500 PSI 0.46 MAX

ABBREVIATIONS

ARCH.

B/

BRG.

BOTT.

C/C C.J.

CLR.

COL.

CONC.

CONN.

CONT.

COORD.

CMU

DIM.

DIA.

DIST.

DWGS.

EL.

E.F.

EMBED.

ENG.

E.O.R.

EQ.

E.S.

E.W.

EXP.

EXT.

FABR.

F.F.

FFE

FTG.

GA.

GALV.

ARCHITECT

BOTTOM OF

BEARING

BOTTOM

CENTER-TO-CENTER

CONTROL JOINT

CLEAR

COLUMN

CONCRETE

CONNECTION

CONTINUOUS

COORDINATE

CONCRETE MASONRY UNIT

DIMENSION

DIAMETER

DISTANCE

DRAWINGS

ELEVATION

EACH FACE

EMBEDMENT

ENGINEER

ENGINEER OF RECORD

EQUAL

EACH SIDE

EACH WAY

EXPANSION

EXTERIOR

FABRICATOR

FINISHED FLOOR

FINISHED FLOOR ELEVATION

FOOTING

GAUGE

GALVANIZED

HORIZ.

H.S.

IN.

INFO.

INT.

K

KSI

LLH

LLV

L.W.

MANUF.

MAX.

MECH.

MIN.

PL.

PSF

PSI

QTY

REF.

REINF.

S.F.

SQU.

STL.

S.W.

T/

TYP.

U.N.O.

VCJ

VMCJ

W/

WWF

HORIZONTAL

HEADED STUD

INCHES

INFORMATION

INTERIOR

KIPS

KIPS PER SQUARE INCH

LONG LEG HORIZONTAL

LONG LEG VERTICAL

LONG WAYS

MANUFACTURER

MAXIMUM

MECHANICAL

MINIMUM

PLATE

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

QUANTITY

REFERENCE

REINFORCED

STEPPED FOOTING

SQUARE

STEEL

SHORT WAYS

TOP OF

TYPICAL

UNLESS NOTED OTHERWISE

VERTICAL CONTROL JOINT

VERTICAL MASONRY CONTROL JOINT

WITH

WELDED WIRE FABRIC

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

G E N E R A L

N O T E S

D E S

IG

N

D A T A

S001

J W K

J W K

P M R

P M R

GENERAL STRUCTURAL NOTES

01 GENERAL

1. DRAWINGS SHOW TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. FOR DETAILS NOT SPECIFICALLY

SHOWN, PROVIDE DETAILS SIMILAR TO THOSE SHOWN.

2. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCY.

3. THE DESIGN, ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR

4. COORDINATE STRUCTURAL CONTRACT DOCUMENTS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL. NOTIFY CONTRACTING OFFICER OF ANY CONFLICT AND/OR OMISSION.

CONTRACTOR SHALL MAKE NO DEVIATION FROM DESIGN DRAWINGS WITHOUT WRITTEN APPROVAL OF THE CONTRACTING OFFICER. FOR ADDITIONAL OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS, SEE ARCHITECTURAL, MECHANICAL AND PLUMBING DRAWINGS.

5. FOR DIMENSIONS NOT SHOWN, SEE ARCHITECTURAL DRAWINGS.

6. REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE CONTRACTING OFFICER DOES NOT RELIEVE

THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP DRAWINGS BEFORE

SUBMITTAL TO THE CONTRACTING OFFICER. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. CONTRACTOR

IS ALSO RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES OF

CONSTRUCTION.

7. ANY BRAND SPECIFIC MATERIALS MAY BE SUBSTITUTED W/ AN EQUIVALENT PRODUCT BY AN ALTERNATE

MANUF. IF APPROVED BY THE ENGINEER OF RECORD, U.N.O.

02 REINFORCED CONCRETE

1. PRIOR TO CASTING FOUNDATIONS, PREPARE THE SITE IN ACCORDANCE WITH PLANS, SPECIFICATIONS

AND REQUIRED COMPACTION.

2. ALL CONCRETE WORK SHALL CONFORM TO ACI 301-05, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. DESIGN IS BASED ON ACI 318-14, BUILDING CODE REQUIREMENTS FOR REINF.

CONCRETE.

3. USE OF CALCIUM CHLORIDE, CHLORIDE IONS OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.

4. CHAMFER OR ROUND ALL EXPOSED CORNERS MINIMUM 3/4".

5. DETAIL CONCRETE REINFORCEMENT AND ACCESSORIES IN ACCORDANCE WITH ACI 315-99, DETAILING MANUAL. SUBMIT SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING REINFORCING STEEL AND ACCESSORIES. DO NOT BEGIN FABRICATION UNTIL

SHOP DRAWINGS ARE COMPLETED AND REVIEWED.

6. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE.

7. WELDED WIRE FABRIC (MESH) SHALL CONFORM TO ASTM A185 AND SHALL BE PROVIDED IN FLAT SHEETS.

LAP EDGES 3 CROSS WIRES MINIMUM.

8. PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR APPROVED;

STAGGER SPLICES WHERE POSSIBLE; USE FULL TENSION SPLICE (CLASS "B") FOR CONTINUOUS REINF.

AND MATCHING DOWELS U.N.O. LAP SPLICES SHALL BE 57 BAR DIAMETERS FOR BARS SMALLER THAN #7

AND 72 BAR DIAMETERS FOR #7 & LARGER.

9. REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER UNLESS NOTED OTHERWISE:

A. CONCRETE CAST AGAINST EARTH (NOT FORMED) . . 3"

B. FORMED CONCRETE EXPOSED TO THE EARTH OR WEATHER

#6 THROUGH #18 BARS . . . . . . . . . . . . . . . 2"

#5 BARS AND SMALLER . . . . . . . . . . . . . . . 1½"

C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER

SUSPENDED SLABS AND WALLS

#14 THROUGH #18 BARS. . . . . . . . . . . . . . . 1½"

#11 BARS AND SMALLER. . . . . . . . . . . . . . . 1"

BEAMS (STIRRUPS) AND COLUMNS (TIES) . . . . . . . . 1½"

10. DO NOT PLACE PIPES OR DUCTS EXCEEDING ONE-THIRD THE SLAB OR WALL THICKNESS WITHIN THE SLAB OR WALL UNLESS SPECIFICALLY SHOWN AND DETAILED ON STRUCTURAL DRAWINGS. ANY PIPES

SHALL BE BETWEEN THE OUTER HORIZONTAL AND VERTICAL LAYERS OF REINF.

11. DO NOT WELD OR TACK WELD REINFORCING STEEL UNLESS APPROVED OR DIRECTED BY THE

STRUCTURAL ENGINEER.

12. REINFORCE SLAB-ON-GRADE AT ALL PENETRATIONS AND AT RE-ENTRANT CORNERS. PLACE THREE # 3x3'-0 AROUND FLOOR DRAINS. PLACE #4x4'-0" (MIN.) AT RE-ENTRANT CORNERS. HOLD REINFORCING 1"

CLEAR FROM TOP OF CONCRETE.

13. WALLS AND OTHER INTERSECTING ELEMENTS SHALL HAVE CORNER BARS TO PROVIDE CONTINUITY. USE

CRSI STANDARDS OR AS SHOWN ON THE DRAWINGS.

14. FOR CONCRETE PADS, SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS.

04 STRUCTURAL STEEL

1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED ACCORDING TO AISC

"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS", LATEST EDITION.

2. THIS STRUCTURE IS CONSIDERED A NON-SELF-SUPPORTING BRACED FRAME. THE CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY SUPPORTS UNTIL ALL PERMANENT BRACING AND FLOOR SLABS ARE IN

PLACE.

3. COORDINATE WALL AND ROOF OPENINGS WITH ARCHITECTURAL AND MECHANICAL PLANS. PROVIDE

FRAMES AS SHOWN.

4. STRUCTURAL STEEL SHALL COMPLY WITH ASTM A36 AND ASTM A992. CHANNELS SHALL COMPLY WITH ASTM A36 AND ALL OTHER STRUCTURAL SHAPES SHALL COMPLY WITH ASTM A992, 50 KSI YIELD. STEEL TUBES SHALL COMPLY WITH ASTM A500, GRADE B 46 KSI YIELD. MISCELLANEOUS PLATES AND SHAPES

MAY BE ASTM A36.

5. CONNECTION BOLTS SHALL CONFORM TO ASTM A325 (OR F1852 FOR TWIST-OFF TYPE BOLT

ASSEMBLIES), 3/4 INCH DIAMETER MINIMUM, UNLESS NOTED OTHERWISE.

6. ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE. STEEL

FABRICATOR SHALL SUPPLY ANCHOR BOLT LOCATION DRAWINGS.

7. INSTALLATION OF A-325 HIGH STRENGTH BOLTS SHALL COMPLY WITH SECTION 8 OF THE RCSC SPECIFICATIONS FOR STRUCTURAL JOINTS USING A-325 OR A-490 BOLTS (RCSC SSJ.) UNLESS OTHERWISE SPECIFIED, ALL JOINTS SHALL BE "SNUG-TIGHTENED" OR "PRETENSIONED" PER RCSC SSJ.

ALL BOLTS SHALL BE TYPE "X" BEARING TYPE CONNECTIONS EXCLUDED FROM SHEAR PLANE.

8. THE STEEL FABRICATOR SHALL BE THE LICENSED "DELEGATED ENGINEER" RESPONSIBLE FOR DESIGNING ALL STEEL CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DESIGN DRAWINGS, AND AS SUCH SHALL SIGN AND SEAL DRAWINGS SHOWING DESIGNED CONNECTIONS. PROVIDE CONNECTIONS FOR REACTIONS AS SHOWN ON PLANS. WHERE REACTION IS NOT SHOWN, DESIGN CONNECTION FOR 1/2 THE TOTAL UNIFORM LOAD CAPACITY SHOWN IN THE MAX. TOTAL UNIFORM LOAD TABLES IN THE AISC

MANUAL OF STEEL CONSTRUCTION.

9. FILLER BEAMS OR JOISTS SHOULD BE SPACED EQUALLY BETWEEN THE COLUMNS IF NOT SPECIFIED

OTHERWISE ON THE DRAWINGS.

10. USE PRE-QUALIFIED WELDED JOINTS AS PER AISC, AND AWS D1.1 "STRUCTURAL WELDING CODE." USE

ONLY CERTIFIED WELDERS. ALL ELECTRODES SHALL CONFORM TO AWS A5 GRADE E70XX.

11. CUTS, BOLTS, COPING, ETC. REQUIRED FOR WORK OR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP. CUTS OR BURNING HOLES IN STRUCTURAL STEEL MEMBERS IN THE

FIELD WILL NOT BE PERMITTED.

12. SHOP CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS MAY BE WELDED OR BOLTED.

FIELD CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS SHALL BE BOLTED, WHERE

POSSIBLE.

05 METAL DECK

1. FABRICATION AND ERECTION OF STEEL DECKING SHALL CONFORM TO THE LATEST EDITION OF THE STEEL DECK INSTITUTES (SJI) SPECIFICATION AND COMMENTARY FOR COMPOSITE STEEL FLOOR DECK, NON-COMPOSITE STEEL DECK AND STEEL ROOF DECK, AS APPLICABLE TO THIS PROJECT.

2. UNLESS NOTED OTHERWISE, ALL STEEL DECKING SHALL HAVE A GALVANIZED COATING CONFORMING TO

ASTM A653, GRADE 60.

3. WHERE METAL DECK IS REQUIRED TO BE PAINTED, PRIMER SHALL BE EITHER FIELD OR SHOP APPLIED.

THE EXTENT OF THE DECK WHICH IS TO BE PRIMED AND PAINTED IS TO BE COORDINATED WITH

ARCHITECTURAL DRAWINGS AND THE PROJECT PAINT SPECIFICATIONS.

4. PROVIDE DECKING CONTINUOUS OVER 3 SPANS MINIMUM WHERE SUPPORTING STRUCTURE PERMITS.

5. STEEL DECKING SHALL BE ERECTED IN STRICT COMPLIANCE WITH THE MANUF.'S RECOMMENDATIONS.

ATTACHMENT: REFER TO DETAIL ON S500 SERIES SHEETS FOR TYPICAL METAL DECK ATTACHMENT.

6. OPENINGS IN DECKS:

CONTRACTOR SHALL ENSURE THAT ALL OPENINGS PENETRATING ROOF DECKS ARE SHOWN ON THE SHOP DRAWINGS PRIOR TO SUBMITTING FOR REVIEW. OPENINGS SHALL BE LOCATED TO CLEAR WALLS, STEEL JOISTS OR STEEL BEAMS, AND OPENINGS 12"x12" OR LARGER WILL REQUIRE STRUCTURAL FRAMES. IF OPENINGS REDUCE STRUCTURAL CAPACITY, ADJUST OPENINGS AND ADD STRUCTURAL ELEMENTS OR OTHER MEASURES AS DIRECTED BY CONTRACTING OFFICER'S REPRESENTATIVE. CARE SHALL BE EXERCISED IN CUTTING OPENINGS, WHEN APPROVED, TO PROVIDE A NEAT EDGE, FREE FROM

SPILLS, SHARP FRAGMENTS OR OTHER DEFECTS.

7. FOR CONCRETE SLAB REINFORCING, REFER TO SECTIONS AND DETAILS.

03 MASONRY

1. CONCRETE MASONRY DESIGN AND CONSTRUCTION SHALL CONFORM TO ACI 530-05, BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY STRUCTURES, ACI 530.1-05, SPECIFICATIONS FOR CONCRETE

MASONRY CONSTRUCTION AND TM-5-809-3, MASONRY STRUCTURAL DESIGN FOR BUILDINGS.

2. PROVIDE NORMAL WEIGHT, HOLLOW, LOAD-BEARING CONCRETE MASONRY UNITS (CMU) CONFORMING

TO ASTM C90, GRADE N, TYPE II.

3. PROVIDE MASONRY CONSTRUCTION WITH MINIMUM COMPRESSIVE STRENGTH, f’m = 1,500 PSI.

4. PROVIDE TYPE “S” MORTAR IN ACCORDANCE WITH ASTM C270.

5. VERTICAL REINFORCING SHALL BE HELD IN POSITION WITH BAR POSITIONERS AT TOP OF THE GROUT

POUR AT SPACINGS AS SHOWN ON THE PLANS.

6. PROVIDE FINE GROUT FOR REINFORCED MASONRY IN ACCORDANCE WITH ASTM C476 WITH MINIMUM 28- DAY COMPRESSIVE STRENGTH OF 2,000 PSI. GROUT SHALL BE FLUID CONSISTENCY, WHICH MEANS AS FLUID AS POSSIBLE FOR POURING WITHOUT SEGREGATION OF THE CONSTITUENT PARTS. GROUT SLUMP SHALL BE 8 TO 10 INCHES. WATER CEMENT RATIO SHALL BE REDUCED AND WATER REDUCERS USED AS REQUIRED TO MAINTAIN SLUMP WHEN PLACED IN LOW ABSORPTION CMU. FILL ALL CELLS BELOW GRADE WITH GROUT. ALL GROUT SHALL BE CONSOLIDATED AT THE TIME OF POURING BY VIBRATING AND THEN RECONSOLIDATED AGAIN BY PUDDLING LATER, BEFORE PLASTICITY IS LOST, TYPICALLY WITHIN 10 TO 15 MIN’s. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR OF THE GROUT 1½” BELOW THE TOP OF THE UPPERMOST UNIT.

7. PROVIDE HORIZONTAL JOINT REINFORCEMENT COMPLYING WITH ASTM A82, NO. 9 GAUGE OR HEAVIER, LADDER TYPE, ZINC COATED, PLACED 16” ON CENTER, UNLESS NOTED OTHERWISE. LADDER RUNGS SHALL BE POSITIONED TO COMPLETELY CLEAR CELL OPENINGS. LAP JOINT REINF. 1 FULL CROSS WIRE SPACING PLUS 2” (18” MIN FOR CROSS WIRE SPACING OF 16” OC), BUT NOT LESS THAN 12”.

8. PROVIDE RUNNING BONDS WITH VERTICAL JOINTS LOCATED AT CENTER OF MASONRY UNITS IN THE

ALTERNATE COURSE BELOW.

9. PROVIDE FOUNDATION DOWELS W/ HOOKS SIZED AND SPACED TO MATCH CMU VERTICAL REINFORCING.

DOWELS SHALL LAP WALL VERTICALS 48 BAR DIAMETERS, UNLESS NOTED OTHERWISE.

10. LAP SPLICE LENGTHS SHALL BE 48 BAR DIAMETERS.

11. CLEANOUT CELLS SHALL BE PROVIDED AT THE BOTTOM OF ALL CELLS TO BE FILLED AT EACH GROUT POUR. ANY OVERHANGING MORTAR OR OTHER OBSTRUCTION OR DEBRIS SHALL BE REMOVED FROM THE INSIDES OF SUCH CELL WALLS. THE CLEANOUTS SHALL BE SEALED BEFORE GROUTING AND AFTER

INSPECTION.

SHEET LIST

SHEET

NUMBER SHEET NAME

S001 GENERAL NOTES & DESIGN DATA

S002 SPECIAL INSPECTIONS

S003 SPECIAL INSPECTIONS

S101 FOUNDATION PLAN

S102 SECOND FLOOR PLAN

S201 ELEVATIONS

S501 TYPICAL FOUNDATION DETAILS

S502 TYPICAL CMU DETAILS

S520 TYPICAL FLOOR DETAILS

7-12-2018

TMS 602-11/ACI 530.1-11/ASCE 6-11

LEVEL B REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION

VERIFICATION AND INSPECTION

FREQUENCY OF INSPECTION REFERENCE FOR CRITERIA

CONTINUOUS PERIODIC TMS 402/ACI

530/ASCE 5

TMS 602/ACI

530.1/ASCE 6

X ART. 1.5

2. AS MASONRY CONSTRUCTION BEGINS, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE:

A. PROPORTIONS OF SITE-PREPARED

MORTAR

X

ART. 2.1,

2.6A

B. CONSTRUCTION OF MORTAR JOINTS X ART. 3.3B

X ART. 3.4,

3.6A

D. LOCATION OF REINFORCEMENT,

CONNECTORS, PRESTRESSING

TENDONS AND ANCHORAGES

E. PRESTRESSING TECHNIQUE X ART. 3.6B

C. GRADE AND SIZE OF PRESTRESSING

TENDONS AND ANCHORAGES

X ART. 2.4B,

2.4H

4. VERIFY DURING CONSTRUCTION:

A. SIZE AND LOCATION OF STRUCTURAL

ELEMENTS.

X ART. 3.3F

B. TYPE, SIZE AND LOCATION OF

ANCHORS, INCLUDING OTHER DETAILS

OF ANCHORAGE OF MASONRY TO

STRUCTURAL MEMBERS, FRAMES, OR

OTHER CONSTRUCTION.

X

SEC. 1.16.4.3,

1.17.1

C. WELDING OF REINFORCING BARS.

D. PREPARATION, CONSTRUCTION AND

PROTECTION OF MASONRY DURING

COLD WEATHER (TEMPERATURE

BELOW 40* F (4.4 C)) OR HOT WEATHER

(TEMPERATURE ABOVE 90* F (32.2 C)).

X

ART. 1.8C,

1.8D

X

SEC. 2.1.7.7.2,

3.3.3.4 (c),

8.3.3.4 (b)

E. APPLICATION AND MEASUREMENT OF

PRESTRESSING FORCE

X ART. 3.6B

3. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE:

A. GROUT SPACE X ART. 3.2D, 3.2F

C. PLACEMENT OF REINFORCEMENT,

CONNECTORS, AND PRESTRESSING

TENDONS AND ANCHORAGE

X SEC. 1.16

X ART. 2.6B,

2.4G.1.b

D. PROPORTIONS OF SITE- PREPARED

GROUT AND PRESTRESSING GROUT

FOR BONDED TENDONS

ART. 3.2E,

3.4, 3.6A

1. VERIFY COMPLIANCE WITH THE APPROVED

SUBMITTALS

F. PROPERTIES OF THIN-BED MORTAR

FOR AAC MASONRY

X ART. 2.1CX —

B. GRADE, TYPE, AND SIZE OF

REINFORCEMENT AND ANCHOR BOLTS,

AND PRESTRESSING TENDONS AND

ANCHORAGES

X SEC. 1.16 ART. 2.4,

3.4

X ART. 3.3BE. CONSTRUCTION OF MORTAR JOINTS ——

F. PLACEMENT OF GROUT AND

PRESTRESSING GROUT FOR BONDED

TENDONS IS IN COMPLIANCE

X ART. 3.5,

3.6C

G. PLACEMENT OF AAC MASONRY UNITS

AND CONSTRUCTION OF THIN-BED

MORTAR JOINTS

X ART.

3.3B.8

X —

5.. OBSERVE PREPARATION OF GROUT

SPECIMENS, MORTAR SPECIMENS,

AND/OR PRISMS:

ART. 1.4B.2.a.3, 1.4B.2.b.3, 1.4B.2.c.3, 1.4B.3, 1.4B.4

—X

MINIMUM TESTS

VERIFICATION OF SLUMP FLOW AND VISUAL STABILITY INDEX (VSI) AS DELIVERED TO THE PROJECT SITE IN ACCORDANCE WITH ARTICLE 1.5 B.1.b.3 FOR SELF-CONSOLIDATING GROUT

VERIFICATION OF f'm AND f'aac IN ACCORDANCE WITH ARTICLE 1.4B PRIOR TO CONSTRUCTION, EXCEPT WHERE

SPECIFICALLY EXEMPTED BY THE CODE.

1. INSPECTION OF REINFORCING STEEL,

INCLUDING PRESTRESSING TENDONS, AND

PLACEMENT.

NOTES:

FOR SI: 1 INCH = 25.4 mm.

a. WHERE APPLICABLE, SEE ALSO SECTION 1705.11, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE.

b. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE

ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2 OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY THE BUILDING OFFICIAL

PRIOR TO THE COMMENCEMENT OF THE WORK.

2. INSPECTION OF REINFORCING STEEL

WELDING IN ACCORDANCE WITH TABLE

1705.2.2, ITEM 2B.

3. INSPECTION OF ANCHORS CAST IN

CONCRETE WHERE ALLOWABLE LOADS

HAVE BEEN INCREASED OR WHERE

STRENGTH DESIGN IS USED

4. INSPECTION OF ANCHORS POST INSTALLED

IN HARDENED CONCRETE MEMBERS.

5. VERIFYING USE OF REQUIRED DESIGN MIX.

6. AT THE TIME FRESH CONCRETE IS

SAMPLED TO FABRICATE SPECIMENS FOR

STRENGTH TESTS,PERFORM SLUMP AND

AIR CONTENT TESTS, AND DETERMINE THE

TEMPERATURE OF THE CONCRETE.

7. INSPECTION OF CONCRETE AND

SHOTCRETE PLACEMENT FOR PROPER

APPLICATION TECHNIQUES.

8. INSPECTION FOR MAINTENANCE OF

SPECIFIED CURING TEMPERATURE AND

TECHNIQUES.

9. INSPECTION OF PRESTRESSED CONCRETE:

10. ERECTION OF PRECAST CONCRETE

MEMBERS.

11. VERIFICATION OF IN-SITU CONCRETE

STRENGTH, PRIOR TO STRESSING OF

TENDONS IN POST TENSIONED CONCRETE

AND PRIOR TO REMOVAL OF SHORES AND

FORMS FROM BEAMS AND STRUCTURAL

SLABS.

12. INSPECT FORMWORK FOR SHAPE,

LOCATION AND DIMENSIONS OF THE

CONCRETE MEMBER BEING FORMED.

X ACI 318: 3.5, 7.1-7.7 1910.4

AWS D1.4

ACI 318: 3.5.2

ACI 318:

8.1.3, 21.2.8 1908.5, 1909.1

X

ACI 318: 3.8.6,

8.1.3, 21.2.8 1909.1

X ACI 318: CH. 4,

5.2-5.4

1904.2, 1910.2, 1910.3

X

ASTM C 172

ASTM C 31

ACI 318: 5.6, 5.8

1910.10

X ACI 318: 5.9, 5.10

1910.6, 1910.7, 1910.8

X ACI 318: 5.11-5.13 1910.9

X ACI 318: CH 16

X ACI 318: 6.1.1

X ACI 318: 6.2

X

CONTINUOUS PERIODIC REFERENCE

STANDARD

IBC

REFERENCE

VERIFICATION AND INSPECTION

FREQUENCY OF INSPECTION REFERENCE FOR CRITERIA

IBC - TABLE 1705.3

REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION

B. GROUTING OF BONDED PRESTRESSING

TENDONS IN THE SEISMIC-FORCE-

RESISTING SYSTEM.

A. APPLICATION OF PRESTRESSING FORCES.

—X ACI 318:18.20

—X ACI 318: 18.18.4

IBC - TABLE 1705.6

REQUIRED VERIFICATION AND INSPECTION OF SOILS

VERIFICATION AND INSPECTION TASK

CONTINUOUS DURING

TASK LISTED

PERIODICALLY DURING

TASK LISTED

1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE

ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.

2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH

AND HAVE REACHED PROPER MATERIAL.

3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED

FILL MATERIALS.

4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT

THICKNESSES DURING PLACEMENT AND COMPACTION OF

COMPACTED FILL.

5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE

SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED

PROPERLY.

— X

— X

— X

— X

X —

SPECIAL INSPECTION NOTES:

1. THE STRUCTURAL ENGINEER (STANTEC) IS NOT RESPONSIBLE FOR INSPECTIONS

AND TESTINGS. OWNER SHALL PROVIDE OR COORDINATE TO GENERAL

CONTRACTOR TO CARRY IN THEIR CONTRACT. STANTEC CAN PROVIDE AS AN

ADDITIONAL SERVICE.

2. THE GENERAL CONTRACTOR'S TESTING LABORATORY SHALL PROVIDE SPECIAL

INSPECTION SERVICES IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE

FOR THE FOLLOWING ITEMS LISTED ON THESE SHEETS. ONLY INSPECTIONS AND

TESTS ARE REQUIRED FOR THE APPLICABLE MATERIALS ON THE PROJECT.

AISC - TABLE N6.1

INSPECTION OF STEEL ELEMENTS OF COMPOSITE CONSTRUCTION PRIOR TO CONCRETE PLACEMENT

CONTINUOUS PERIODIC

PLACEMENT AND INSTALLATION OF STEEL DECK

INSPECTION TASKS AFTER BOLTING

FREQUENCY OF INSPECTION

—X

PLACEMENT OF STEEL HEADED STUD ANCHORS —X

DOCUMENT ACCEPTANCE OR REJECTION OF STEEL ELEMENTS —X

IBC - TABLE 1704.3

REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION

CONTINUOUS PERIODIC REFERENCE

STANDARD

IBC

REFERENCE

1. MATERIAL VERIFICATION OF COLD-FORMED STEEL DECK:

A. FOR OTHER STEEL, IDENTIFICATION

MARKINGS TO CONFORM TO ASTM

STANDARDS SPECIFIED IN THE

APPROVED CONSTRUCTION

DOCUMENTS.

X

APPLICABLE ASTM

MATERIAL

STANDARD

X

1) FLOOR AND ROOF DECK WELDS. X AWS D1.3

B. REINFORCING STEEL:

1) VERIFICATION OF WELDABILITY OF

REINFORCING STEEL OTHER

THAN ASTM A 706.

2) REINFORCING STEEL RESISTING

FLEXURAL AND AXIAL FORCES IN

INTERMEDIATE AND SPECIAL

MOMENT FRAMES, AND BOUNDARY

ELEMENTS OF SPECIAL

STRUCTURAL WALLS OF CONCRETE

AND SHEAR REINFORCEMENT.

3) SHEAR REINFORCEMENT.

4) OTHER REINFORCING STEEL.

AWS D1.4 ACI

318: SECTION

3.5.2

X

X

X

X

VERIFICATION AND INSPECTION

FREQUENCY OF INSPECTION REFERENCE FOR CRITERIA

B. MANUFACTURER’S CERTIFIED TEST

REPORTS.

2. INSPECTION OF WELDING:

A. COLD-FORMED STEEL DECK:

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

S P E C

IA

L

IN

S P E C T

IO

N S

S002

J W K

J W K

P M R

P M

AISC - TABLE N5.6-1

INSPECTION TASKS PRIOR TO BOLTING

CONTINUOUS PERIODIC

MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTNER MATERIALS

INSPECTION TASKS PRIOR TO BOLTING

FREQUENCY OF INSPECTION

—X

FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS X—

PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT

LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR)

X—

PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL X—

CONNECTION ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE

CONDITION AND OLE PREPARATION, IF SPECIFIED, MEET APPLICABLE

REQUIREMENTS

X—

PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL

OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND ETHODS USED

X—

X—

PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER

FASTENER COMPONENTS

AISC - TABLE N5.6-2

INSPECTION TASKS DURING BOLTING

CONTINUOUS PERIODIC

FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND

WASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED

INSPECTION TASKS DURING BOLTING

FREQUENCY OF INSPECTION

X—

JOINTBROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING

OPERATION

X—

FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM

ROTATING

X—

FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC

SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM MOST RIGID POINT

TOWARD THE FREE EDGES

X—

AISC - TABLE N5.6-3

INSPECTION TASKS AFTER BOLTING

CONTINUOUS PERIODIC

DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS

INSPECTION TASKS AFTER BOLTING

FREQUENCY OF INSPECTION

—X

AISC - TABLE N5.4-1

INSPECTION TASKS PRIOR TO WELDING

CONTINUOUS PERIODIC

WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE

INSPECTION TASKS PRIOR TO WELDING

FREQUENCY OF INSPECTION

—X

MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE —X

MATERIAL INDENTIFICATION (TYPE/GRADE) X—

WELDER IDENTIFICATION SYSTEM X—

FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)

- JOINT PREPARATION

- DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)

- CLEANLINESS (CONDITION OF STEEL SURFACES)

- TACKING (TACK WELD QUALITY AND LOCATION)

- BACKING TYPE AND FIT (IF APPLICABLE)

X—

CONFIGURATION AND FINISH OF ACCESS HOLES X—

FIT-UP OF FILLET WELDS

- DIMENSIONS (ALIGNMENT, GAPS AT ROOT)

- CLEANLINESS (CONDITION OF STEEL SURFACES)

- TACKING (TACK WELD QUALITY AND LOCATION)

X—

AISC - TABLE N5.4-2

INSPECTION TASKS DURING WELDING

CONTINUOUS PERIODIC

USE OF QUALIFIED WELDERS

INSPECTION TASKS DURING WELDING

FREQUENCY OF INSPECTION

X—

CONTROL AND HANDLING OF WELDING CONSUMABLES

- PACKAGING

- EXPOSURE CONTROL

X—

NO WELDING OVER CRACKED TACK WELDS X—

ENVIRONMENTAL CONDITIONS

- WIND SPEED WITHIN LIMITS

- PRECIPITATION AND TEMPERATURE

X—

WPS FOLLOWED

- SETTINGS ON WELDING EQUIPMENT

- TRAVEL SPEED

- SELECTED WELDING MATERIALS

- SHIELDING GAS TYPE/FLOW RATE

- PREHEAT APPLIED

- INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.)

- PROPER POSITION (F,V,H,OH)

X—

WELDING TECHNIQUES

- INTERPASS AND FINAL CLEANING

- EACH PASS WITHIN PROFILE LIMITATIONS

- EACH PASS MEETS QUALITY REQUIREMENTS

X—

AISC - TABLE N5.4-3

INSPECTION TASKS AFTER WELDING

CONTINUOUS PERIODIC

WELDS CLEANED

INSPECTION TASKS AFTER WELDING

FREQUENCY OF INSPECTION

X—

SIZE, LENGTH, AND LOCATION OF WELDS —X

WELDS MEET VISUAL ACCEPTANCE CRITERIA

- CRACK PROHIBITION

- WELD/BASE-METAL FUSION

- CRATER CROSS SECTION

- WELD PROFILES

- WELD SIZE

- UNDERCUT

- POROSITY

—X

ARC STRIKES —X

k-AREA

—XBACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)

—X

—XREPAIR ACTIVITIES

—XDOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER

SPECIAL INSPECTION NOTES:

1. THE STRUCTURAL ENGINEER (STANTEC) IS NOT RESPONSIBLE FOR INSPECTIONS

AND TESTINGS. OWNER SHALL PROVIDE OR COORDINATE TO GENERAL

CONTRACTOR TO CARRY IN THEIR CONTRACT. STANTEC CAN PROVIDE AS AN

ADDITIONAL SERVICE.

2. THE GENERAL CONTRACTOR'S TESTING LABORATORY SHALL PROVIDE SPECIAL

INSPECTION SERVICES IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE

FOR THE FOLLOWING ITEMS LISTED ON THESE SHEETS. ONLY INSPECTIONS AND

TESTS ARE REQUIRED FOR THE APPLICABLE MATERIALS ON THE PROJECT.

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

S P E C

IA

L

IN

S P E C T

IO

N S

S003

J W K

J W K

P M R

P M

1. EXISTING SLAB ON GRADE SHALL BE DEMOLISHED AS REQ'D TO INSTALL NEW

FOUNDATIONS AND COLUMNS. SLAB SHALL BE PATCHED BACK TO MATCH EXISTING.

INSTALL ON VAPOR BARRIER W/ CAPILLARY WATER BARRIER.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND

ELEVATIONS BEFORE STARTING WORK. NOTIFY CONTRACTING OFFICER OF ANY

DISCREPANY.

3. NEW FTG SHALL MATCH EXISTING FTG ELEV.

4. PROVIDE (2) #4 X 4'-0" AT ALL SLAB REENTRANT CORNERS, PLACED DIAGONALLY TO

CORNER.

FOUNDATION NOTES:

FOUNDATION LEGEND:

= EXISTING CMU WALL

= T/FTG.

= 6'-0" x 6'-0" x 1'-4" PAD FTG.

W/ (5) #6 BARS E.W. BOTT.

= 2'-0" x 6'-0" x 1'-0" PAD FTG.

W/ (2) #5 BARS L.W. TOP & BOTT.

#5 BARS AT 12" C/C S.W. TOP & BOTT.

= 2'-0" x 5'-0" x 0'-10" PAD FTG.

W/ (2) #5 BARS L.W. BOTT. &

#5 BARS AT 12" C/C S.W. BOTT.

T/FTG.

F6.0

F2.0 x 6.0

F2.0 x 5.0

S201

23.5

N.8 M.5N.3

21.7

0'-9" 13'-9" 7'-0" 13'-4" 7'-5" 2'-0"

22.4

23.4

21.6

M.7

21.3

N.6N.7 N.9

EXISTING STEEL

COLUMN, TYP.

EXISTING STEEL

COLUMN, TYP.

EXISTING STEEL

COLUMN, TYP.

F6.0

6' -0

6' -0

S501

T/FTG. 0'-0"

NEW FTG.,

SAW-CUT EXISTING

SLAB & FOUNDATION

HSS5X5X1/4

HSS5X5X1/4

HSS5X5X1/4

EXISTING STRIP

FOOTING

EXISTING STRIP

FOOTING

NEW FTG.,

SAW-CUT EXISTING

SLAB & FOUNDATION

EXISTING PAD

FOOTING, TYP.

NEW FTG.,

SAW-CUT EXISTING

SLAB & FOUNDATION

EXISTING PAD

FOOTING, TYP.

EXISTING PAD

FOOTING, TYP.

EXISTING CMU WALL AND

PERIMETER FOUNDATION, TYP.

OPENING

19'-8" NEW WALL

EXISTING WALL

OPENING

EXISTING 8"

CMU WALL

T/FTG. 0'-0"

T/FTG. -2'-8"

NEW

NEWNEW

SAW-CUT

EXISTING

SLAB 4'-11"

S501

2'-0" 2'-0"

T/FTG. -2'-8"

F2.0 x 6.0 F2.0 x 6.0

F2.0 x 5.0

S501

S501

SIM

EXISTING PAD

FOOTING, TYP.

7' -9

2'

-5

'-3

'-3

1"

EXISTING STEEL

COLUMN, TYP.

3' -4

/4

4'

-8

/1

6" EXISTING

STAIRS

T/FTG. 0'-0"

NEW HSS 4X4X1/4

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

F O U N D A T

IO

N

P L A N

S101

J W K

J W K

P M R

P M R

1/4" = 1'-0"S101

1 FOUNDATION PLAN

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

FLOOR FRAMING SHEET NOTES:

1. TOP OF STEEL BEAMS SHALL BE 12'-0" U.N.O.

2. FLOOR DECK SHALL BE 3" - 20 GAUGE COMPOSITE METAL DECK W/ 3.5" CONC. FOR

TOTAL OF 6 1/2" THICKNESS W/ 1.4 X 1.4 WWF IN 6"x6" PATTERN.

3. SHORE COMPOSITE DECK UNTIL THE CONCRETE HAS REACHED 75 PERCENT OF

ITS SPECIFIED STRENGTH.

4. DECK ANGLE-SEE SECTIONS SHEET S-520.

5. PROVIDE WELDED STUDS, Fu = 65 ksi, FOR COMPOSITE BEAMS, SEE PLAN FOR

QUANTITY. PROVIDE (5) MIN. IF NONE SHOWN UNLESS NOT SUPPORTING SLAB.

6. SEE PLAN FOR ALLOWABLE BEAM REACTIONS. DO NOT DESIGN CONNECTION FOR

LESS THAN 10 KIPS.

7. CONTRACTOR OPTION: STEEL FABRICATOR TO DESIGN SPLICE AT MID-SPAN

OF FLOOR AND GIRDER BEAMS. FABRICATOR SHALL DESIGN SPLICE CONNECTION

FOR MAXIMUM ALLOWABLE BEAM MOMENT AND SHEAR CAPACITY.

FLOOR FRAMING LEGEND:

D.E.

= INDICATES DECK DIRECTION

= INDICATES DECK EDGE DIMENSION

= EXISTING CMU WALL

W12X19 (18) C=3/4"

BEAM SIZE

CAMBER

No. OF 3/4" DIAM. X 5 1/2"

SHEAR STUDS

FLOOR BEAM LEGEND

UNFACTORED

BEAM REACTION

8K 8K

S201

23.5

N.8 M.5N.3

21.7

22.4

23.4

21.6

M.7

21.3

N.6N.7 N.9

T/ SLAB 12'-6 1/2"

T/ STEEL 12'-0"

NEW STAIRS BY

STEEL FABR.,

SEE ARCH

1' -7

/8

D .E

D.E.

1'-0"

D.E.

0'-11 1/2"

D.E.

0'-10"

D .E

8' -4

D .E

4' -0

W

X

8)

W

X

8)

W

X

8)

W

X

8)

W

X

8)

W12X19 (8,3,10)

W

X

8)

W12X19 (8,3,8,2)

W

X

8)

W

X

8)

W

X

W12X26

W

X

9)

W10X12

W10X12

W

X

7)

0'-9" 13'-9" 7'-0" 13'-4" 7'-5" 2'-0"

3' -4

/4

4'

-8

/1 6"

W

X

W

X

5)

W

X

7)

6'-11" 6'-11" 6'-11"

W

X

7)

W

X

7)

W

X

7)

OPENING

4'-0" NEW WALL

W10X12 (1,6,3,6) W10X12 (5,3,6,1)

1'-0"

S520

S520

S520

S520

S520

SIM

S520

W

X

7)

6'-5"8'-5"4'-6"

T/ STEEL 12'-0"

S520

SIM

W

X12

W8X10

S520

S520

SIM

W

X

S520

S520

S520

T/ SLAB 12'-6 1/2"

6K 10 K

6K10 K

K

K

K

6K 10 K

6K10 K

K

K

K

6K 10 K

6K

K

K

K

K19K 26K 21K 19K

6K

K

6K

K

K

K

K

15K 10K 11K 15K

19K 10K

3K 6K 7K

5K 4K

7K6K3K 5K

2K 2K

4K 5K

CONTRACTOR OPTION:

STEEL FABRICATOR

DESIGN BEAM SPLICE

AT MIDSPAN OF FLOOR

AND GIRDER BEAMS.

SEE SHEET NOTE #7.

7' -9

2'

-5

'-3

'-3

1"

4'-11"

W

X

8)

W

X

8)

6'-11" 6'-11" 6'-11"

EXISTING STL.

COLUMN, TYP.

(5) #5 BARS x 8'-0" CENTERED

OVER GIRDER (EVENLY SPACED),

1 1/2" CLR. FROM T/SLAB

S520

S520

SIM

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

S E C O N D

F L O O R

P L A N

S102

J W K

J W K

P M R

P M R

1/4" = 1'-0"S102

2 SECOND FLOOR

1. REFER TO DETAIL 1/S503 FOR REINFORCEMENT REQUIREMENTS AT NEW OPENINGS.

2. REFERENCE ARCHITECTURAL SHEETS FOR OPENING DIMENSIONS AND ELEVATIONS.

ELEVATION NOTES:

FOUNDATION PLAN

0'-0"

N.8 N.3

SECOND FLOOR

12'-6 1/2"

M.7N.6N.7 N.9

0'-9" 13'-9" 7'-0" 13'-4" 7'-5"

NEW STAIR LANDING

EXISTING

STL. COL.

EXISTING

OPNG.

NEW OPENING

5'-4" +/- REF. ARCH.

NEW OPENING

5'-4" +/- REF. ARCH.

R E

F A

R C

H

'-0

NEW OPENING

4'-0" +/- REF. ARCH.

NEW OPENING

5'-4" +/- REF. ARCH.

'-4

R E

F A

R C

H

'-0

NEW OPENING

19'-8" +/- REFER TO ARCH.

R E

F A

R C

H

'-4

EXISTING

FOUNDATION

EXISTING

CMU WALL

T/OPNG.

SEE ARCH.

T/OPNG.

SEE ARCH.

NEW STAIR FRAMING

S502

S502

ISOMETRIC VIEW IS FOR GENERAL REFERENCE ONLY

AND SHALL NOT BE USED FOR CONSTRUCTION,

BIDDING, OR ESTIMATING PURPOSES. 1

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

E L E V A T

IO

N S

S201

J W K

J W K

P M R

P M R

1/4" = 1'-0"S201

1 SOUTH ELEVATION

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

NOT TO SCALES201

2 ISOMETRIC VIEW

NEW STEEL

COLUMN,

SEE PLAN

SAW-CUT EXISTING

SLAB, TYP.

EPOXY

DOWEL

#3 LUBRICATED SMOOTH

DOWEL x 12" LONG WITH

CAP, AT 12" C/C PLACED

AT SLAB MID-DEPTH

T

AT T/4, TYP.

1/8" SAW CUT FILL W/ SELF-LEVELING

SEALANT PER ASTM C290,

GRADE P, CLASS 25

RE-COMPACTED

FILL

± 2" GROUT

T/EXISTING

SLAB

12"x12"x3/4" B.P.

W/ (4) 3/4" Ø A.B.

(8" MIN. EMBEDMENT)

TYP.

1 1/2"

TYP.

8"

TYP.

4"

CONC. FTG.,

SEE PLANEXISTING

CONC. SLAB

0' -1

0"

2'-0" (2) #4 BARS LONG WAYS,

CONTINUOUS

#4 BARS SHORT WAYS

AT 12" C/C

STAIR COLUMN,

SEE PLAN

#3 LUBRICATED SMOOTH

DOWEL x 12" LONG WITH

CAP, AT 12" C/C PLACED

AT SLAB MID-DEPTH

4", TYP.

T

AT T/4, TYP.

1/8" SAW-CUT

SAW-CUT

EXISTING

SLAB, TYP.

EPOXY

DOWEL

CONC. FTG.,

SEE PLAN

T/EXISTING

SLAB

FILL W/ SELF-LEVELING

SEALANT PER ASTM C290,

GRADE P, CLASS 25

± 2" GROUT

12"x12"x5/8" B.P.

W/ (4) 5/8" Ø A.B.

(6" MIN. EMBEDMENT)

RE-COMPACTED FILL

TYP.

1 1/2"

EPOXY DOWEL

1'-0"

AT T/4, TYP.

1/8" SAW-CUT FILL W/ SELF-LEVELING

SEALANT PER ASTM C290,

GRADE P, CLASS 25

T/EXISTING

SLAB

#3 LUBRICATED SMOOTH

DOWEL x 12" LONG WITH

CAP, AT 12" C/C PLACED

AT SLAB MID-DEPTH

4", TYP.

T/FTG.

SEE PLAN

CONC. FTG.,

SEE PLAN

GROUT

SOLID

EXISTING

FOUNDATION

EXISTING

CMU WALL

NEW STEEL

COLUMN,

SEE PLAN

1/2" EXP. JNT.

COAT COL. BELOW GRADE

W/ BLACK ASPHALTIC PAINT

10"x14"x3/4" B.P.

W/ (4) 3/4" Ø A.B.

EPOXY DOWELED W/

8" MIN. EMBEDMENT

4" CAPILLARY WATER

BARRIER W/ 10 MIL MIN.

VAPOR BARRIER

± 2" GROUT

RE-COMPACTED

FILL

CONCRETE COVER

3" MIN AT BASE PL./

ANCHOR BOLTS

EPOXY DOWEL,

12" MIN. EMBED.

REPLACEMENT SLAB W/ ONE

LAYER OF WWF, 6"x6"-W1.4xW1.4

IN TOP 1/3 OF SLAB

TYP.

1 1/2"

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

T Y P

IC

A L

F O U N D A T

IO

N

D E T A

IL

S

S501

J W K

J W K

P M R

P M R

1" = 1'-0"S501

1 INTERIOR COLUMN FOOTING

1 1/2" = 1'-0"S501

2 FOUNDATION AT STAIR POSTS

0 0'-6" 1' 2'

SCALE: 1" = 1'-0"

0 0'-4" 0'-8" 1'-4"

SCALE: 1 1/2" = 1'-0"

1" = 1'-0"S501

3 FTG. SECTION AT EXISTING FOUNDATION

MAX OPENING

SPAN

MAX

WIDTH

NEW CMU WALL OPENING SCHEDULE

8'-0"

ADDED HORIZONTAL

REINF. U.N.O.

DEPTH OF FULLY

GROUTED CELLS

ADDED VERTICAL REINF. MIN. BEARING ON ADJACENT

FULLY GROUTED CELLS

24" N/A (2) #5 BOTT., (1) #5 TOP 16"

HORIZ. SAWCUTS TO ADD

REINFORCEMENT

NOTES:

1. VERIFY ALL CMU OPENINGS W/ ARCHITECT DWG'S.

VERTICAL REINF.,

SEE SCHEDULE

SEE SCHEDULE FOR ADDED

BOTTOM REINFORCEMENT

6'-0" 8" 16" N/A (1) #5 BOTT., (1) #5 TOP 8"

8"

SEE SCH.

20'-0" 64" N/A (2) #6 BOTT., (2) #5 TOP 32"8"

CMU TO REMAIN

CMU TO BE REMOVED

ONCE HEADER AND

JAMBS ARE REINFORCED

AND GROUTED SOLID

GROUT ACCESS HOLES

8" CMU

O F

F U

LL

Y

G R

O U

T E

D C

E

LL

S

S E

E S

C H

. F O

R D

E P

T H

SEE SCHEDULE FOR ADDED

TOP REINFORCEMENT

1 3 4

EXISTING FOOTING

FOR 8" CMU: PROVIDE (1) #6

VERTICAL AT EACH CELL NEW CMU WALL OPENING

REMOVE AFTER EXISTING WALL

IS REINFORCED AND GROUTED

SOLID

EXISTING SLAB ON GRADE

EPOXY DOWEL 4"

INTO FOOTING

CMU WALL ELEVATION

REFER TO ARCH.

REFER TO SCHEDULE

REFER TO PLANS AND ARCH.

G R

O U

T E

D C

E

LL

S D

E P

T H

O F

F U

LL

Y

FILL WITH CONCRETE TO

MATCH EXISTING

S E

E S

C H

E D

U L

E

TOP HORIZ.

REINF., SEE SCH.

BOTT. HORIZ. REINF.,

SEE SCHEDULE

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

T Y P

IC

A L

C M U

D E T A

IL

S

S502

J W K

J W K

P M R

P M R

1" = 1'-0"S502

1 EXISTING CMU WALL OPENING DETAIL

0 0'-6" 1' 2'

SCALE: 1" = 1'-0"

GROUT ACCESS HOLES

STL. BEAM,

SEE PLAN

SHEAR PLATE

BY STL. FABR.

EXISTING CMU

GROUT SOLID

CONC. DECK,

SEE PLAN

4" x 6 1/2" x 1/4"

BENT PLATE, LLV

CONTINUOUS

T/SLAB

SEE PLAN

STUD,

SEE PLAN

16"x16"x1/2" PLATE W/ (9) 3/4" Ø x 6"

EXP. ANCHORS

CELLS GROUTED

SOLID ADJACENT

TO PLATE

GROUT SOLID

12" MIN.

16"x16"x1/2" PLATE W/ (9) 3/4" Ø x 6"

EXP. ANCHORS

STEEL BEAM,

SEE PLAN

ELEVATION VIEW

NOTE: CONCRETE

DECK NOT SHOWN

FOR CLARITY

2" 6"

6" 2"

2" 6" 6" 2"

1 1/2"

STL. BEAM,

SEE PLAN

EXISTING CMU

CONC. DECK,

SEE PLAN

T/SLAB

SEE PLAN

STUD,

SEE PLAN

8" MIN. x 24" MIN. CONC.

BEARING (3500 PSI MIN.),

EXTEND TO CORNER

FULLY GROUTED

CMU BELOW

5"x3"x1/2"x6" EACH SIDE

LLV SHOP WELDED (BEAM

BEARING ANGLES OR

APPROVED EQUAL)

3/8" STIFFENER

1/4 5/8"x8"x12"

BEARING PLATE

W/ (3) 3/4 Ø x 6"

HEADED STUDS

(2) #5 BARS

CON'T.

COMPOSITE METAL

DECK, SEE PLAN

SHEAR PLATE

BY STL. FABR.

CONC. DECK,

SEE PLAN

T/SLAB

SEE PLAN

STUD,

SEE PLAN

STEEL BEAM,

SEE PLAN

T/STL.

SEE PLAN

SHEAR PLATE

BY STL. FABR.

CONC. DECK,

SEE PLAN

T/SLAB

SEE PLAN

STEEL COLUMN,

SEE PLAN

T/STL.

SEE PLAN

STEEL BEAM,

SEE PLAN

EXISTING

CMU WALL

8" x 6 1/2" x 1/4"

BENT PLATE, LLH

CONTINUOUS

5/8"Ø x 6" EXP.

ANCHOR AT 24" C/C,

GROUT CELLS SOLID

AS REQUIRED

STUD,

SEE PLAN

STEEL BEAM,

SEE PLAN

CONC. DECK,

SEE PLAN

T/SLAB

SEE PLAN

STEEL BEAM,

SEE PLAN

T/STL.

SEE PLAN

5/8"Ø x 6" EXP. ANCHOR

AT 24" C/C, GROUT CELLS

SOLID AS REQUIRED

EXISTING

CMU WALL

CONC. DECK,

SEE PLAN

T/SLAB

SEE PLAN

STEEL BEAM,

SEE PLAN

T/STL.

SEE PLAN

1/

2"

D.E.

SEE PLAN

1/4" CON'T.

BENT PLATE

CONC. DECK,

SEE PLAN

T/SLAB

SEE PLAN

STEEL BEAM,

SEE PLAN

T/STL.

SEE PLAN

1/4" CON'T.

BENT PLATE

SHEAR PLATE

BY STL. FABR. STL. COLUMN,

SEE PLAN

MC12 STAIR STRINGER

BY SPECIALTY ENGINEER

NOTES:

1. COORDINATE STAIRS WITH ARCHITECTURAL.

SHEAR PLATE

BY STL. FABR.

CONC. DECK,

SEE PLAN

T/SLAB

SEE PLAN

STUD,

SEE PLAN

T/STL.

SEE PLAN

W12 BEAMW12 BEAM

SPLICE PLATES

BY STL. FABR.

DESIGN CONNECTION

FOR BEAM MAX.

SHEAR & MOMENT

CAPACITY

EXISTING CMU

COLUMN WRAP

EXISTING CMU

COLUMN WRAP

E X

IS

T

IN

G

S T

L.

C

O

LU

M N

STEEL BEAM,

SEE PLAN

CONC. DECK,

SEE PLAN

T/SLAB

SEE PLAN

SHEAR PLATE BY

STL. FABR.

SAW-CUT EXISTING CMU,

REPAIR AS REQ'D TO ORIGINAL

FORM AFTER BEAM INSTALLATION

T/STL.

SEE PLAN

F

E B

PUBLIC WORKS

B

C

D

E

F

G

2 3 4 5 6 7 8 9 101

A

A N

S I D

SHEET ID

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

35% SUBMITTAL

NOT FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

T

E D

B Y

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S

BRAGG

J

O N

E S

F R

A N

K L

IN

R D

S

T E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

FOR OFFICIAL USE ONLY

100% SUBMITTAL

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

J

U L Y

R E

N O

V A

T E

P H

Y S

IC

A

L T

H E

R A

P Y

A R

E A

B

U

IL

D

IN

G O

M

S

O T

F F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

T Y P

IC

A L

F L O O R

D E T A

IL

S

S520

J W K

J W K

P M R

P M R

1" = 1'-0"S520

1 BEAM TO EXISTING CMU WALL

1" = 1'-0"S520

2 BEAM POCKET AT EXISTING CMU WALL

1" = 1'-0"S520

3 BEAM-TO-BEAM CONNECTION

1" = 1'-0"S520

4 BEAM-TO-COLUMN CONNECTION

1" = 1'-0"S520

5 SLAB EDGE AT SOUTH WALL

1" = 1'-0"S520

6 SLAB EDGE AT STAIR DECK

1" = 1'-0"S520

7 SLAB EDGE AT STAIR LANDING

1" = 1'-0"S520

8 CANTILEVERED BEAM AT STAIR DECK

1" = 1'-0"S520

9 BEAM AT EXISTING COLUMN

0 0'-6" 1' 2'

SCALE: 1" = 1'-0"

S I

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L

E N

A M

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

P

T I O

N

J O

N E

S

F

R A

N K

L

S

R A

L E

I G

H

N

C

F

A X

L I C

E N

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

R E

N O

V A

Y

S I C

A L

T

H E

R A

E

A

B U

I L D

I N

G

O

M

S

O T

F

F O

A

G G

N

O R

R

O L I N

A

D E

P A

R T

M E

T

M

Y

F O

A

G G

N

O R

R

O L I N

A

D I R

E C

T O

R A

P

U B

L

R

K S

L

LS101

FIRST FLOOR LIFE SAFETY PLAN - CONSTRUCTION PHASE

1/16" - 1'-0'

PROJECT

LOCATION

BUILDING KEY PLAN - NOT TO SCALE

EXISTING 2-HOUR FIRE

RESISTIVE WALL

LS101

C O

N S

T R

U C

T I O

N

P

H A

S E

M A

B

M A

B

T F

T F

F I R

O

F

E

S

A F

E T

Y

P

L A

N

3049A

GYM 1

3049B

GYM 2

3049D

REHAB

3049C

REHAB

OFFICE

POOL

COMBAT

S P

I N

E

S P

I N

E

STORAGE

CORR

C O

R R

PT

TESTING

3055A

JAN

CORR

MEN

WOMEN

MECH

POOL

EQPM'T

OFFICE

MAT/FRAME

STUDIO

SAUNA

COMBAT

LEGEND

EXISTING CONSTRUCTION

TRAVEL PATH

DECISION POINT ALONG

TRAVEL PATH

INTERSECTION POINT OF

MULTIPLE TRAVEL PATHS

2"

32"

1,163

OCCUPANT LOAD TAG

AREA

OCCUPANT LOAD

NUMBER OF OCCUPANTS

OCCUPANT EXIT TAG

OCCUPANT LOAD USING EXIT

REQUIRED EXIT WIDTH

PROVIDED EXIT WIDTH

EXIT DOOR

(1) 48" DOOR

45" CLEAR OPENING WIDTH

225 PERSONS MAX.

(0.2" PER OCCUPANT)

ACTUAL 8

D1

D2 EXIT DOOR

(1) 48" DOOR

45" CLEAR OPENING WIDTH

225 PERSONS MAX.

(0.2" PER OCCUPANT)

ACTUAL 8

APPROXIMATE AREA OF CONSTRUCTION OF

NEW STAIR ASSEMBLY TO SECOND LEVEL.

THIS AREA TO REMAIN ACCESSIBLE AS

LONG AS POSSIBLE TO EXISTING STAIRS &

EXIT DOOR PER CONTRACTOR PHASING

AND GOVERNMENT APPROVAL

POTENTIAL DOOR

ACCESSIBILITY PER

CONTRACTOR PHASING

AND GOVERNMENT

APPROVAL

TEMPORARY CONSTRUCTION &

DUST CONTROL WALL AND CEILING

EXISTING RAMP TO REMAIN

OPEN DURING PROJECT

PRIMARY WORK

AREA PARTITION

CONTRACTOR ENTRY & ACCESS

FROM PROJECT LOCATION

THRU SPINE CORRIDOR TO

STAGING AREA

S I

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L

E N

A M

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

P

T I O

N

J O

N E

S

F

R A

N K

L

S

R A

L E

I G

H

N

C

F

A X

L I C

E N

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

R E

N O

V A

Y

S I C

A L

T

H E

R A

E

A

B U

I L D

I N

G

O

M

S

O T

F

F O

A

G G

N

O R

R

O L I N

A

D E

P A

R T

M E

T

M

Y

F O

A

G G

N

O R

R

O L I N

A

D I R

E C

T O

R A

P

U B

L

R

K S

L

LS102

SECOND FLOOR LIFE SAFETY PLAN - CONSTRUCTION PHASE

1/16" - 1'-0'

PROJECT

LOCATION

BUILDING KEY PLAN - NOT TO SCALE

EXISTING 2-HOUR FIRE

RESISTIVE WALL

LS102

C O

N S

T R

U C

T I O

N

P

H A

S E

M A

B

M A

B

T F

T F

S E

C O

O

F

E

S

A F

E T

Y

P

L A

N

3049A

GYM 1

BELOW

3049B

GYM 2

BELOW

POOL

BELOW

S P

I N

E

3055B

OFFICE

3054A

RECOVERY

MEMORIAL

COURT

MEMORIAL

GARDEN

APEX

LEGEND

EXISTING CONSTRUCTION

TRAVEL PATH

DECISION POINT ALONG

TRAVEL PATH

INTERSECTION POINT OF

MULTIPLE TRAVEL PATHS

2"

32"

1,163

OCCUPANT LOAD TAG

AREA

OCCUPANT LOAD

NUMBER OF OCCUPANTS

OCCUPANT EXIT TAG

OCCUPANT LOAD USING EXIT

REQUIRED EXIT WIDTH

PROVIDED EXIT WIDTH

EXIT DOOR

(1) 48" DOOR

45" CLEAR OPENING WIDTH

225 PERSONS MAX.

(0.2" PER OCCUPANT)

ACTUAL 8

D1

D2 EXIT DOOR

(1) 48" DOOR

45" CLEAR OPENING WIDTH

225 PERSONS MAX.

(0.2" PER OCCUPANT)

ACTUAL 8

TEMPORARY CONSTRUCTION &

DUST CONTROL WALL AND CEILING

APPROXIMATE AREA OF

CONSTRUCTION OF NEW

STAIR ASSEMBLY TO SECOND

LEVEL. THIS AREA TO REMAIN

ACCESSIBLE AS LONG AS

POSSIBLE TO EXISTING

STAIRS & EXIT DOOR PER

CONTRACTOR PHASING AND

GOVERNMENT APPROVAL

S P

I N

E

PRIMARY WORK

AREA PARTITION

T

R A

V E

L

T

R A

V E

L

T

R A

V E

L

T

R A

V E

L

36' TRAVEL

(EFE)

S M

H

R

(EFE)

(EFE)

T

R A

V E

L

A

V

E

L

39'-5" TRAVEL

(NFE)

A N

S I

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

P

T I O

N

J O

N E

S

F

R A

N K

L

S

R A

L E

I G

H

N

C

F

A X

L I C

E N

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

R E

N O

V A

Y

S I C

E

R A

E

A

B U

I L

D I N

G

O

M

S

O T

F

F O

A

G G

N

O R

R

O L

I N

A

D E

P A

R T

M E

T

M

Y

F O

A

G G

N

O R

R

O L

I N

A

D I R

E C

T O

R A

P

U B

L

R

K S

J U

L

PLAN

NORTH

T

R

U

E

N

O

R

T

H

A N

S I

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C A

T E

G O

D

E

D E

P

T I O

N

J O

N E

S

F

R A

N K

L

S

R A

L E

I G

H

N

C

F

A X

L I C

E N

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

R E

N O

V A

Y

S I C

E

R A

E

A

B U

I L

D I N

G

O

M

S

O T

F

F O

A

G G

N

O R

R

O L

I N

A

D E

P A

R T

M E

T

M

Y

F O

A

G G

N

O R

R

O L

I N

A

D I R

E C

T O

R A

P

U B

L

R

K S

J U

L

X X

X G d g n

LS103

F I R

C

O N

D

F

L O

O R

L I F

E

S

A F

E T

Y

P

L A

R

K

M A

B

M A

B

T F

T F

LS103

FIRST FLOOR LIFE SAFETY PLAN

3/32" - 1'-0'

PLAN

NORTH

T

R

U

E

N

O

R

T

H

PROJECT

LOCATION

BUILDING KEY PLAN - NOT TO SCALE

PLAN

NORTH

T

R

U

E

N

O

R

T

H

3049A

GYM 1

3049B

GYM 2

3049D

REHAB

POOL

REHAB

CORR

C O

R R

3055A

JAN

CORR

MEN

WOMEN

SAUNA

LS103

SECOND FLOOR LIFE SAFETY PLAN

3/32" - 1'-0'

COMBAT

EXISTING ARTIFICIAL

GRASS SURFACE TRAINING

AREA TO REMAIN OPEN

DURING PROJECT

3049A

GYM 1

BELOW

3055F

STORAGE

3055E

RECOVERY

EXISTING RAMP TO REMAIN

OPEN DURING PROJECT

EXISTING STAIR

ASSEMBLY

GYM 1 FLOOR

0'-0"

GYM 2 FLOOR

7'-0" AFF

3055C

OFFICE

3055D

TESTING

B

C O

R R

I D

O R

LIFE SAFETY CODE EVALUATION

OCCUPANCY: MIXED WITHOUT SEPARATION, CHAPTER 39, BUSINESS

CLASSIFICATION OF HAZARDS OF CONTENTS (40.1.5): ORDINARY

MINIMUM CONSTRUCTION REQUIREMENTS (40.1.6): NONE

EGRESS CAPACITY (40.2.3) AND NUMBER OF EXITS (40.2.4):

3 DOORS @ 33" CLEAR = 99 INCHES

1 DOOR @ 45" CLEAR = 45 INCHES

144/0.2 INCHES PER OCCUPANT = 242 OCCUPANTS

EGRESS ARRANGEMENT (40.2.5) WITH SPRINKLER SYSTEM:

DEAD END CORRIDOR (TABLE 40.2.5): 50 FT

COMMON PATH OF TRAVEL (TABLE 40.2.5): 100 FT

TRAVEL DISTANCE (40.2.6): 300 FT

EXIT LIGHTING (40.2.10): PROVIDED

PROTECTION OF VERTICAL OPENINGS (40.3): SHAFTS AND STAIRS WILL BE

1HR RATED

PROTECTION FROM HAZARDS (40.3.2): NO…