NOTES
OF CHANNEL AGAINST
PLACE FLANGED SIDE
CONCRETE
CARRIAGE BOLTS
5/8" DIA. GALVANIZED
PUNCH SQUARE HOLES FOR BOLTS
IN CHANNEL PRIOR TO GALVANIZING.
50 LB BULK
ZINC ZNODE
2" STEEL CHANNEL
3/16" DIA. ROUND STEEL BAR
WELDED ON BOTH SIDES
IN CONDUIT
TO RE-BAR AND ROUTED
NO. 4 CABLE BRAZED
1 1/4" DIA. PVC PIPE FILLED
WITH EPOXY TO ENCASE
CABLE-BAR CONNECTION
2" STEEL CHANNEL
BOLTED WITH ANODE
STRAP ON BOTH ENDS
BULK ANODE SPLICE DETAIL
PVC TERMINAL BOX
AND NEGATIVE CONNECTION
TO EXISTING REBAR
EXISTING PILE (SIZE VARIES)
GROUT FILLER
ENTIRE PERIMETER
AND LENGTH OF JACKET
ZINC BULK ANODE CLAMPED
AROUND CONCRETE PILE
3/4" DIA. PVC CONDUIT
ROUTED TO TOP OF JACKET
ZINC BULK ANODE WIRE
NO. 4 HMWPE COPPER WIRE
ROUTED INSIDE JACKET
NEW REBAR NEGATIVE
CONNECTION WIRE
APPROXIMATELY EL. 9.0 (FIELD VERIFY)
PVC TERMINAL BOX
AND NEGATIVE CONNECTION
TO EXISTING REBAR
CONDUIT
B E
N T C
A P
B O
T T
O M O
F
(DIA. VARIES)
OCTAGONAL PILE
ANNULUS
P
IL
E D
IA
M E T E R
3" MAX.
ANNULUS
FORM INSIDE DIA.
J
A C
K E
T L
E N
G T
H8
N O
T E A
N O
T E A
BELOW BAY BOTTOM.
JACKET IMBEDMENT
REQUIRED TO AVOID
JACKET LENGTH AS
PLACEMENT, REDUCE
ZINC BULK ANODE
IMPEDES JACKET AND
WHERE THE MUDLINE
NOTE A:
M A
X
M
IN
DEBRIS CAPTURE AND CONTAINMENT
ACCORDANCE WITH SECTION 03 01 30.71 CONCRETE REHABILITATION.
CATHODIC PROTECTION PILE JACKETS SHALL BE INSTALLED IN
TRESTLE PILES ARE BATTERED 1.5:12.
PLUMB AND BATTERED PILES. WHARF PILES ARE BATTERED 3:12 AND
CATHODIC PROTECTION PILE JACKETS WILL BE REQUIRED ON BOTH
1.
2.
3.
4.
1.
" MIN.
BULK ANODE ASSEMBLY
(TYPICAL FOR BATTERED & PLUMB PILES) (SEE NOTE B)
CATHODIC PROTECTION PILE JACKET
EXISTING OCTAGONAL PILE
50 LB. BULK ZINC ANODE
GROUT FILLER
ANODE JACKET DETAILS
SUBSEQUENT DISPOSAL.
ENTERING THE WATERWAY SHALL BE RETRIEVED IMMEDIATELY FOR
WATERWAY OR ALLOWED TO SETTLE TO THE BOTTOM. ANY DEBRIS
REGULATIONS. NO DEBRIS SHALL BE ALLOWED TO ENTER THE
OFFSITE IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND
ACTIVITIES SHALL BE CAPTURED AND CONTAINED, AND DISPOSED OF
DECK SPALL REMOVAL, AND SUBSEQUENT REPAIR/CONSTRUCTION
ALL DEBRIS CREATED BY CONCRETE PILE JACKET REMOVAL, UNDER
EPOXY COATED REBAR
BAR SIZE
LAP SPLICE
EMBEDMENT 13"
17"
#3 #4
18"
#5
30"
22"
#6
34"
26" 38"
50"
#7 #8
58"
44" 50"
64"
#9 #10
72"
54"
#11
78"
60"
24"
S-127
P
IL
E J
A C
K E
T S
C A
T H
O D
IC
P
R O
T E
C T
IO
N N
O R
T H W
H A
R F tr v s b -s p jk .d g n
M.L.L.W. EL. 0.0
CONTRACTOR’S PILE INSPECTIONS.
ADDITIONAL PILES WHICH MAY BE DISCOVERED DURING THE
BE THOSE DESIGNATED ON SHEETS S-101 THRU S-113, AND POSSIBLE
PILES TO RECEIVE CATHODIC PROTECTION PILE JACKETS SHALL
COATED.
DETAILS SHALL APPLY. BARS SHALL BE EPOXY
OTHER CATHODIC PROTECTION PILE JACKET
OF 2" CLEAR COVER SHALL BE PROVIDED. ALL
BAR TIES (HORIZ.) EQUALLY SPACED. A MINIMUM
w/8-#7 BARS (VERT.) EQUALLY SPACED AND 9-#4
THE ANNULUR SPACE SHALL BE REINFORCED
SECTION 03 01 30.71 OF THE SPECIFICATIONS.
STRUCTURAL CONCRETE FILL SHALL BE PER
ANNULUS SHALL BE INCREASED BY 2 INCHES.
INSIDE FORM DIAMETER , MAX ANNULUS AND MIN.
WHEN STRUCTURAL JACKETS ARE REQUIRED,
NOTE B:
STAINLESS STEEL SCREWS
SHALL BE ATTACHED WITH
PVC TERMINAL BOX COVER
ZINC
ZINC ANODE
CONNECTION WIRE
ZINC ANODE CONNECTION WIRE
ZINC ANODE AROUND
LOCATION OF EXISTING PILES TO BE REPAIRED.
APPURTENANCES ACCORDINGLY. SEE SHEETS S101 THRU S113 FOR
VERIFYING PILE DIAMETER AND SIZING PILE JACKET AND
VARY IN DIAMETER. THE CONTRACTOR IS RESPONSIBLE FOR FIELD
ALL EXISTING PILES TO BE REMOVED ARE OCTAGONAL IN SHAPE AND
(SEE NOTE B)
FIBERGLASS FORM
ROUND STAY-IN-PLACE
FIBERGLASS FORM
STAY-IN-PLACE
EPOXY SEALED FIBERGLASS
FORM INTER-LOCKING JOINT
S
E P
T
A M
D T
A D
D E
D F
IB
E R
G L
A S
S
T O T
E X
T L
A B
E L S
F
IL
E N
A M
E
S U
-0
-1
D R
A W
IN
G C
O D
E
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
fiof Engineers
US Army Corps
"x
S
IZ
E
W
IL
M
IN
G T
O N
N O
R T
H C
A R
O L
IN
A
D
A R
L
IN
G T
O N A
V E
N U
E W
IL
M
IN
G T
O N D
IS
T R
IC
T U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
L
C R
E E
C H
F E
S C
L U
S A
J
H A
R G
R O
V E J
M
IT
C H
E L L
B R
U N
S W
IC
K C
O U
N T
Y
N O
R T
H C
A R
O L
IN
A M
IL
IT
A R
Y O
C E
A N T
E R
M
IN
A L S
U N
N Y P
O
IN
T
M O
T S
U
F O
R T
H E N
O R
T H W
H A
R F
J N P
IL
E
D E
C K M
IS
C
E L L
A N
E O
U S R
E P
A
IR
S J
H A
R G
R O
V E J
M
IT
C H
E L L
W P
M
B
A U
G U
S T
IF
B N
O
File details come from the government source that posted it.