AdvPlans_MF-00024-4P.pdf
PDF 4 MB Posted
- Solicitation number
- W912PM-15-B-0010
About this file
Plans
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MF24-4P_Bid_Abstract_KO_Signed.pdf | ||
| Bid_Opening_Attendance_28AUG15.pdf | ||
| W912PM-15-B-0010-0001.pdf | ||
| Plate_NumberSD101-Amndt001.pdf | ||
| AdvSpecs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
PROJECT LOCATION
032190
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
M A R K A. L A Z O
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
A
P ro je ct
M a n a g e r:
J o h n
P h a ri s
C A
T E
G O
R Y
C O
D E
A
S S
H O
W N
3-31-15
/3
/2
:3
:0
P M
Wilmington District
M A
L
B D
M
M A
L
G-001
W
IL
M I N
G T
O N
D
IS
T R
IC
T
M A
L
C O
V E
R S
H E
E T
F T
B R
A G
G N
C
G E
N E
R A
L
G -0
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
WILMINGTON DISTRICT
CORRECTED 100% SUBMITTAL
31 MARCH 2015
M
A R
C H
REPAIR KENNEL FACILITY
FT BRAGG, NC
BUILDING OX104, 3SFG
MF-00024-4P
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D I N
G O
X S
F G
M F
-0
-4
P
# OF
TOTAL SHEET NO. SHEET TITLE
MECHANICAL
12 M-001 GENERAL NOTES & LEGENDS
13 MD101 MECHANICAL DEMOLITION PLAN
14 M-101 MECHANICAL NEW WORK PLAN
15 M-501 MECHANICAL DETAILS
16 M-502 MECHANICAL DETAILS
17 M-601 MECHANICAL SCHEDULES
18 M-701 CONTROLS AND OPERATION
ELECTRICAL
19 ED101 ELECTRICAL DEMOLITION PLAN
20 E-101 ELECTRICAL NEW WORK PLAN
Grand total: 20
# OF
TOTAL SHEET NO. SHEET TITLE
GENERAL
1 G-001 COVER SHEET
ARCHITECTURAL
2 AD121 REFLECTED CEILING DEMOLITION PLAN
3 A-121 REFLECTED CEILING NEW WORK PLAN
4 A-301 BUILDING SECTIONS & INTERIOR ELEVATIONS
FIRE PROTECTION
5 FD101 FIRE PROTECTION DEMOLITION PLAN
6 FS001 FIRE PROTECTION GENERAL NOTES & LEGENDS
7 FS101 FIRE PROTECTION NEW WORK PLAN
PLUMBING
8 P-001 GENERAL NOTES AND LEGENDS
9 PD101 PLUMBING DEMOLITION PLAN
10 P-101 PLUMBING NEW WORK PLAN
11 P-501 PLUMBING DETAIL AND SCHEDULE
INDEX OF DRAWINGS
SCALE: NOT TO SCALEC4
SITE LOCATION
SCALE: NOT TO SCALEB4
BASE LOCATION MAP
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
IFB No: W912PM-15-B-0010
DF1 DF1 DF1 DF1 DF1 DF1 DF1
DF1DF1DF1DF1DF1DF1DF1
DF1 DF1 DF1 DF1 DF1 DF1 DF1
DF1
DF1 DF1
DF1 DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF2
CEILING DEMO AREA
SEE ARCHITECTURE
CEILING DEMO AREA
SEE ARCHITECTURE
CEILING DEMO AREA
SEE ARCHITECTURE
PHASE II
PHASE I
EXISTING DRY PIPE RISER
GENERAL NOTES:
1. CONTRACTOR TO FIELD VERIFY ALL
EXISTING CONDITIONS BEFORE
BEGINNING CONSTRUCTION.
032190
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
M A R K A. L A Z O
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:2 :5
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
M A
L
B D
M
M A
L
FD101
W
IL
M I N
G T
O N
D
IS
T R
IC
T
M A
L
F
IR
E P
R O
T E
C T
IO
N
D E
M O
L
IT
IO
N
P L A
N
F T
B R
A G
G N
C
F
IR
E P
R O
T E
C T
IO
N
F
D
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: 1/8" = 1'-0"B1
FIRE PROTECTION DEMOLITION PLAN
DEMOLITION KEYNOTES:
NO. DESCRIPTION
DF1 REMOVE AND REPLACE EXISTING DRY PENDANT
SPRINKLER HEAD TO ACCOMODATE NEW CEILING
MOUNTED SOUND ABSORBING MATERIAL.
DF2 EXISTING SPRINKLER MAIN TO REMAIN. REMOVE
EXISTING SPOOL PIECE SERVING EACH BRANCH
LINE IN PHASE I AND PLUG OPENING TO KEEP
PHASE II AREA IN SERVICE DURING CONSTRUCTION.
REPEAT PROCESS FOR PHASE II TO KEEP PHASE I
AREA IN SERVICE DURING PHASE II CONSTRUCTION.
PLAN NORTH
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
NOT IN SCOPE
KEY PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
FIRE PROTECTION LEGEND
SPRINKLER HEAD
FIRE SPRINKLER NOTES:
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA 13.
2. REFER TO HAZARD CLASSIFICATION LEGEND FOR DESIGN
DENSITIES, DESIGN AREAS, AND HOSE STREAM DEMANDS.
3. DRY-PIPE SPRINKLER SYSTEM SHALL COMPLY WITH THE REQUIRED
AND ADVISORY PROVISIONS OF NFPA 13.
4. VERIFY EXACT LOCATION AND INVERT ELEVATION IN FIELD BEFORE
BEGINNING WORK.
5. ALL SUSPENDED PIPING SHALL BE SUPPORTED FROM FLOOR OR
ROOF STRUCTURAL MEMBERS.
6. ALL CHANGES IN PIPE SIZES SHALL BE MADE THROUGH TAPERED
REDUCING FITTINGS. REDUCING COUPLINGS ARE NOT PERMITTED.
7. COORDINATE ALL WORK WITH OTHER TRADES.
8. FIRE STOP ALL PENETRATIONS OF FIRE RATED ASSEMBLIES.
9. PROVIDE EARTHQUAKE PROTECTION FOR ALL FIRE PROTECTION
SYSTEMS. USE SEISMIC DESIGN CATEGORY C.
10. ALL PIPING SHALL BE INSTALLED SUCH THAT IS PROTECTED
AGAINST FREEZING.
11. FIRE SUPPRESSION PLANS AND DETAILS ARE FOR DIAGRAMMATIC
PURPOSES ONLY. PIPES SIZES, AND RUNS AS WELL AS CONDUIT
RUNS AND MANNER OF CONNECTION SHALL BE DETERMINED BY THE
CONTRACTOR IN ACCORDANCE WITH THE EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS, AND APPLICABLE NFPA
STANDARDS.
12. ALL DRY PENDANT SPRINKLERS SHALL BE STANDARD RESPONSE
TYPE.
13. SPRINKLER HEADS EQUIPPED WITH "O-RING" WATER SEALS SHALL
NOT BE UTILIZED.
14. NO PENDENT/UPRIGHT SPRINKLER HEAD SHALL BE CLOSER THAN 4"
TO A WALL.
EXISTING DRY PIPE SYSTEM IS DESIGNED BASED ON THE FOLLOWING:
DESIGN DENSITY:
DESIGN AREA:
CALCULATED FLOW DEMAND:
CALCULATED PRESSURE DEMAND:
HOSE STREAM DEMAND:
SPRINKLER DESIGN DATA:
0.10 GPM/FT²
3928 FT²
1199.31 GPM
57.41 PSI
500 GPM
032190
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
M A R K A. L A Z O
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:2 :5
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
M A
L
B D
M
M A
L
FS001
W
IL
M I N
G T
O N
D
IS
T R
IC
T
M A
L
F
IR
E P
R O
T E
C T
IO
N
G E
N E
R A
L N
O T
E S
L
E G
E N
D S
F T
B R
A G
G N
C
F
IR
E P
R O
T E
C T
IO
N
F
S
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
F1
TYP.
EXISTING SPRINKLER SYSTEM TO
REMAIN IN SERVICE AT ALL TIMES
F2
HANGING SOUND
ABSORPTIVE BANNER
HANGING SOUND
ABSORPTIVE BANNER
PHASE II
PHASE I
KENNEL
CORRIDOR
KENNEL
CORRIDOR
KENNEL
CORRIDOR
KENNEL
CORRIDOR
EXISTING DRY PIPE RISER
MECH.
ELEC.
F3
F4
GENERAL NOTES:
1. REPLACE ALL SPRINKLERS IN KIND TO
ACCOMMODATE NEW CEILING MOUNTED
SOUND ABSORBING MATERIAL.
032190
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
M A R K A. L A Z O
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:2 :5
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
M A
L
B D
M
M A
L
FS101
W
IL
M I N
G T
O N
D
IS
T R
IC
T
M A
L
F I R
E P
R O
T E
C T
IO
N
N E
W W
O R
K P
L A
N
F T
B R
A G
G N
C
F
IR
E P
R O
T E
C T
IO
N
F
S
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: 1/8" = 1'-0"B1
FIRE PROTECTION NEW WORK PLAN
NEW WORK KEYNOTES:
NO. DESCRIPTION
F1 NEW DRY PENDANT SPRINKLER HEAD, REPLACE IN
KIND.
F2 EXISTING SPRINKLER MAIN TO REMAIN.
F3 CONNECT NEW DUCT SMOKE DETECTOR TO
EXISTING FIRE ALARM SYSTEM.
F4 EXISTING FIRE ALARM PANEL TO REMAIN.
PLAN NORTH
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
NOT IN SCOPE
KEY PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
LABOR, EQUIPMENT AND MATERIALS ARE TO BE PROVIDED TO COMPLETE
THE PLUMBING WORK INDICATED ON THESE DRAWINGS AS REQUIRED BY
LOCAL CODE AND ORDINANCES.
THE WORK SHALL INCLUDE DOMESTIC COLD WATER PIPING, AS INDICATED
ON THESE DRAWINGS. ALSO, THE HOOKUP OF FIXTURES SCHEDULED AND
INSULATION OF PIPING SHALL BE INCLUDED.
ITEMS, SUCH AS FITTINGS, ETC. NOT MENTIONED BUT UNDERSTOOD TO
BE NECESSARY TO COMPLETE THE PLUMBING SYSTEM SHALL BE
INCLUDED.
INSTALLATION SHALL BE PER PLANS AND SPECIFICATIONS AND NORTH
CAROLINA PLUMBING CODE. SEE SPECIFICATIONS FOR PRODUCT AND
INSTALLATION REQUIREMENTS.
COORDINATE LOCATION OF PLUMBING WORK WITH OTHER TRADES TO
AVOID CONFLICTS AND INTERFERENCES.
ALL EQUIPMENT, AND PIPE ABOVE CEILING SHALL BE SUPPORTED FROM
BUILDING STRUCTURE ABOVE, UNLESS OTHERWISE NOTED.
FLOOR DRAINS SHALL BE DEEP SEAL TRAP TYPE WITH 3/8" TRAP PRIMER
CONNECTION TO NEAREST CW SOURCE.
REMOVAL OF FIXTURES, PIPING, ETC. IS TO INCLUDE ALL ASSOCIATED
HANGERS, SUPPORTS, BRACKETS, AND APPURTENANCES PHYSICALLY
ATTACHED AT THE COMMENCEMENT OF DEMOLITION, UNLESS NOTED
OTHERWISE.
LOCATIONS OF FIXTURES, PIPING, ETC. IS DIAGRAMMATIC ONLY AND IS NOT
INTENDED TO SHOW EXACT LOCATION.
WHERE FIXTURES OR PIPING IS REMOVED AND NOT REPLACED, PATCH AND
FINISH AREAS TO MATCH ADJACENT SURFACES.
GENERAL NEW WORK NOTES:
1.
2.
3.
4.
5.
6.
7.
GENERAL DEMOLITION NOTES:
1.
2.
3.
LEGEND:
POINT OF CONNECTION BETWEEN NEW AND EXISTING
DOMESTIC HOT WATER, HW
DOMESTIC COLD WATER, CW
EXISTING PIPING
TO BE REMOVED
POINT OF DISCONNECTION BETWEEN EXISTING TO REMAIN AND EXISTING TO BE REMOVED
TYP. TYPICAL
(E) EXISTING
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :2
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
X
P-001
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
G E
N E
R A
L N
O T
E S
A N
D L
E G
E N
D S
F T
B R
A G
G N
C
P L U
M B
IN
G
P
-0
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
DP1 DP1
DP1 DP1
DP1
PHASE II
PHASE I
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :2
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
PD101
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
P L U
M B
IN
G
D E
M O
L
IT
IO
N
P L A
N
F T
B R
A G
G N
C
P L U
M B
IN
G
P
D
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
DEMOLITION KEYNOTES:
NO. DESCRIPTION
DP1 ISOLATE, DISCONNECT, AND REMOVE ALL
EXISTING WATER HOSE REELS AND REEL
COVERS. TURN OVER REMOVED WATER HOSE
REELS AND REEL COVERS TO THE
GOVERNMENT.
SCALE: 1/8" = 1'-0"B1
PLUMBING DEMOLITION PLAN
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
PLAN NORTH
NOT IN SCOPE
KEY PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
P1
P1
P1
P1
P1
PHASE II
PHASE I
HR-1 HR-1
HR-1 HR-1 HR-1
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :2
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
P-101
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
P L U
M B
IN
G
N E
W W
O R
K P
L A
N
F T
B R
A G
G N
C
P L U
M B
IN
G
P
-1
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
NEW WORK KEYNOTES:
NO. DESCRIPTION
P1 INSTALL NEW WATER HOSE REELS MOUNTED IN
THE SAME LOCATIONS AS THE REMOVED
REELS. ALL NEW HOSE REELS SHALL BE
INSTALLED WITH THE SCHEDULED COVER. SEE
HOSE REEL INSTALLATION DETAIL ON SHEET
P-501. ALL CONNECTING FITTINGS USED SHALL
BE THE SAME I.D. OR LARGER THAN THE NEW
HOSE I.D.
SCALE: 1/8" = 1'-0"B1
PLUMBING NEW WORK PLAN
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
PLAN NORTH
NOT IN SCOPE
KEY PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
REPLACE HOSE REEL
ASSEMBLY WITH NEW
REPLACE EXISTING HOSE AND
ALL FITTINGS TO MATCH
UPSTREAM INNER PIPE DIAMETER
MOUNT NEW HOSE REEL
PER MANUFACTURER
INSTRUCTIONS
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :2
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
P-501
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
P L U
M B
IN
G
D E
T A
IL
A
N D
S C
H E
D U
L E
F T
B R
A G
G N
C
P L U
M B
IN
G
P
-5
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: NOT TO SCALEC1
HOSE REEL REPLACEMENT DETAIL
PLUMBING FIXTURE SCHEDULE
Mark FIXTURE
CW N.P.T.
CONNECTION REMARKS
HR-1 3/4 IN I.D. x 50 FT, LOCKING SPRING RETURN STEEL HOSE REEL SYSTEM 3/4" REFER TO UFGS 22 00 00 FOR ALL REQUIRED COMPONENTS AND FEATURES
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
TO BE REMOVED/DEMOLISHED
EXISTING DUCTWORK/MECHANICAL (TO REMAIN)
NEW DUCTWORK/MECHANICAL
SUPPLY DUCT UP OR DOWN
RETURN DUCT UP OR DOWN
EXHAUST DUCT UP OR DOWN
EXHAUST GRILLE
SPIN-IN W/DAMPER (45° OR 90° TAP)
DIRECTION OF AIRFLOW
DUCT TRANSITION
T N
FLEXIBLE DUCT-MAX. 3' LONG
SEE SCHEDULE FOR SIZES
TURNING VANES
MANUAL VOLUME DAMPER
THERMOSTAT
POINT OF CONNECTION
BETWEEN NEW AND EXISTING
POINT OF DISCONNETION BETWEEN EXISTING
TO REMAIN AND EXISTING TO BE REMOVED
MAKEUP AIR UNIT
ROOFTOP EXHAUST FAN
OUTDOOR AIR
EXHAUST AIR
SUPPLY AIR
TYPICAL
MAU
REF
OA
EA
SA
TYP.
CENTER LINE
FLEXIBLE CONNECTIONFC
X ### AIR DISTRIBUTION MARK, SEE SCHEDULE M-601
OUTSIDE AIR TEMPERATURE SENSOROAT
LEGEND:
TEMPERATURE SENSORTS
RELATIVE HUMIDITY SENSORRHS
HVAC EMERGENCY SHUTDOWN (PUSH BUTTON) SWITCHES
LINEAR SLOT DIFFUSER
COORDINATE LOCATION OF MECHANICAL WORK WITH
OTHER TRADES TO AVOID CONFLICTS AND
INTERFERENCES.
ALL EQUIPMENT, PIPE AND DUCTWORK SHALL BE INSTALLED
ABOVE CEILING STRUCTURE, UNLESS OTHERWISE NOTED.
DUCTWORK SHALL BE GALVANIZED STEEL FABRICATED AND
INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS.
DUCT SIZES INDICATED ARE NET FREE INSIDE DIMENSIONS.
INSTALL ALL EQUIPMENT PER MANUFACTURER'S
RECOMMENDATIONS.
INSTALL CONTROL SYSTEM COMPLETE WITH WIRING,
COMPONENTS, ETC.
GENERAL NEW WORK NOTES:
1.
2.
3.
4.
5.
6.
DUCTWORK AND EQUIPMENT LOCATIONS AND SIZES
SHOWN ARE BASED ON VISUAL FIELD VERIFICATION.
ALL EQUIPMENT, DUCTWORK, PIPING, ETC. INDICATED TO BE
REMOVED BY KEYED DEMOLITION NOTES IS EXISTING.
REMOVAL OF EQUIPMENT, DUCTWORK, PIPING, ETC. IS TO
INCLUDE ALL ASSOCIATED HANGERS, SUPPORTS,
BRACKETS, CONTROLS, AIR DEVICES, EQUIPMENT
FOUNDATION/MOUNTING PADS AND APPURTENANCES
PHYSICALLY ATTACHED AT THE COMMENCEMENT OF
DEMOLITION, UNLESS NOTES OTHERWISE.
ALL DEMOLITION SHALL BE PER 02 41 00 SPECIFICATION.
EXISTING EQUIPMENT INDICATED TO BE REUSED SHALL BE
CLEANED AND SERVICED PRIOR TO REUSE.
GENERAL DEMOLITION NOTES:
1.
2.
3.
4.
5.
DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT TO BE
SCALED FOR DIMENSIONS, UNLESS DIMENSIONED.
ALL EXTERIOR AND INTERIOR FINISHED SURFACES WHICH ARE
DAMAGED WHILE PERFORMING WORK UNDER THIS CONTRACT
SHALL BE PATCHED AND/OR REPLACED WITH FINISH TO MATCH
THOSE OF THE ADJACENT SURFACES. THIS INCLUDES
PATCHING AND FINISHING EXISTING SURFACES THAT ARE
DAMAGED ADJACENT TO AND IN THE VICINITY OF THE NEW
WORK.
THE CONTRACTOR SHALL BECOME TOTALLY FAMILIARIZED
WITH, AND VERIFY, ALL EXISTING CONDITIONS AND
DIMENSIONS THAT AFFECT THIS CONTRACT.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD.
ALL MATERIALS NOTED ARE NEW UNLESS SPECIFICALLY
NOTED AS EXISTING.
GENERAL NOTES:
1.
2.
3.
4.
5.
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :0
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
M-001
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
G E
N E
R A
L N
O T
E S
L
E G
E N
D S
F T
B R
A G
G N
C
M E
C H
A N
IC
A
L
M
-0
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
DM1
DM2
DM3 DM4
PHASE II
PHASE I
REF
DM5
MAU
10x1010x810x610x4 12x10 1 x
10x4 10x6 10x8 10x10 12x10 x x x x
DEMO CONCRETE PAD
GENERAL NOTES:
1. IMMEDIATELY AFTER DEMOLITION OF
COMPONENTS THAT PENETRATE THE
BUILDINGS EXTERIOR ENVELOPE (E.G., WALLS
AND ROOF PENETRATIONS), CONTRACTOR
SHALL TEMPORARILY SEAL THESE
PENETRATIONS AS REQUIRED TO MAKE THEM
WEATHERTIGHT.
2. CONTRACTOR SHALL COORDINATE PHASING
OF ALL CONSTRUCTION ACTIVITIES WITH
GOVERNMENT.
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :2
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
MD101
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
M E
C H
A N
IC
A
L D
E M
O L
IT
IO
N P
L A
N
F T
B R
A G
G N
C
M E
C H
A N
IC
A
L
M
D
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
DEMOLITION KEYNOTES:
NO. DESCRIPTION
DM1 DISCONNECT AND TURN OVER EXISTING
MAKEUP AIR UNIT AND ALL ASSOCIATED DUCT
HEATERS TO FT. BRAGG DPW. DEMOLISH ALL
ASSOCIATED PIPING, CONTROLS, HANGERS,
AND ACCESSORIES COMPLETE. DEMOLISH
ASSOCIATED EXISTING CONCRETE EQUIPMENT
PAD.
DM2 DISCONNECT AND TURN OVER EXISTING
ROOFTOP EXHAUST FAN (REF) TO FT. BRAGG
DPW. DEMOLISH ALL ASSOCIATED CONTROLS,
HANGERS, AND ACCESSORIES COMPLETE.
EXISTING ROOF CURB TO REMAIN. PROVIDE
AND INSTALL TEMPORARY ROOF CAP AS
REQUIRED TO ENSURE WEATHERTIGHT.
DM3 DEMOLISH EXISTING SUPPLY AIR DUCTWORK
COMPLETE.
DM4 DEMOLISH EXISTING EXHAUST AIR DUCTWORK
COMPLETE.
DM5 REUSE EXISTING PENETRATION WITH NEW
WORK.
SCALE: 1/8" = 1'-0"B1
MECHANICAL DEMOLITION PLAN
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
PLAN NORTH
NOT IN SCOPE
KEY PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P x
17ø
15ø
8ø17ø 16ø 15ø 14ø 12ø 11ø
8ø17ø 16ø 15ø 14ø 12ø 11ø ø x
19ø 22ø 24ø 26ø 28ø
1 200
A 643 A 643 A 643 A 643 A 643 A 643 A 642
B 370
(TYP. OF 14) (TYP. OF 28)
M2
(TYP. OF 14)
TM4
M1
MIN. 6" MIN. 6"
NEW EQUIPMENT PAD
MIN.
5' - 0"
MAU-1
24x16
M3
PHASE II
PHASE I
M5 M6
M1
REF-1
ROUTE CONDENSATE TO
SPLASH BLOCK OFF PAD
GENERAL NOTES:
1. IMMEDIATELY AFTER DEMOLITION OF
COMPONENTS THAT PENETRATE THE
BUILDINGS EXTERIOR ENVELOPE (E.G., WALLS
AND ROOF PENETRATIONS), CONTRACTOR
SHALL TEMPORARILY SEAL THESE
PENETRATIONS AS REQUIRED TO MAKE THEM
WEATHERTIGHT.
2. CONTRACTOR SHALL COORDINATE PHASING
OF ALL CONSTRUCTION ACTIVITIES WITH
GOVERNMENT.
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :0
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
M-101
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
M E
C H
A N
IC
A
L N
E W
W O
R K
P L A
N
F T
B R
A G
G N
C
M E
C H
A N
IC
A
L
M
-1
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: 1/8" = 1'-0"B1
MECHANICAL NEW WORK PLAN
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
PLAN NORTH
NEW WORK KEYNOTES:
NO. DESCRIPTION
M1 CONTRACTOR SHALL PROVIDE AND INSTALL
NEW EQUIPMENT PAD PER DETAIL D3 ON SHEET
M-501 AND NEW MAU-1 PER DETAIL A2 ON
SHEET M-501.
M2 PROVIDE AND INSTALL OUTSIDE AIR TRANSFER
GRILLES PER DETAIL A3 ON SHEET M-502.
COORDINATE CMU BLOCK DEMOLITION.
M3 PROVIDE AND INSTALL NEW REF-1 PER DETAILS
A1 AND C1 OF SHEET M-501.
M4 PROVIDE AND INSTALL DUCT MOUNTED PROBE
SENSORS COMBINATION
THERMOMETER/HUMIDISTAT IN THE LOCATION
SHOWN.
M5 PROVIDE AND INSTALL HVAC EMERGENCY
SHUTDOWN SWITCH IN LOCATION SHOWN.
SWITCH SHALL BE TIED INTO THE
SUPERVISORY BUILDING CONTROLLER.
M6 PROVIDE AND INSTALL TOUCHSCREEN DDC
CONTROLLER FOR USE WITH DRYING MODE
OPERATION PER MAU-1 SEQUENCE OF
OPERATION. SEE SHEET M-601.
NOT IN SCOPE
KEY PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
BOLT ON 4" CENTERS
1" FLANGE AND HEM
1" x 1/8" BAND IRON
RUBBER
IMPREGNATED
FABRIC
24 US GUAGE STEEL
ALTERNATE
POSITION OF BOLT
DUCT
1-1/2" POCKET SLIP
28ø
REF-1
28ø
REUSE
EXISTING ROOF
CURB
22ø
24x16
20x20
20x20
TO MAU-1
SE-1
20x20-20x20
SE-2
16x24-16x24
SE-3
24x16-24x16
SEE DETAIL A1
ON SHEET M-502
O/A
PKGD MAU-1
SEE EQUIPMENT PAD DETAIL
ROUTE CONDENSATE DRAIN
TO SPLASH BLOCK. SIZE PIPE
PER MANUFACTURER'S
RECOMMENDATION, 1" MIN.
SEE GOOSENECK DETAIL - A4/M-501
PROVIDE AND INSTALL
GALVANIZED UNI-STRUT
DUCT SUPPORT
10' - 0" MIN.
S/A
FLEXIBLE CONNECTION
FLEXIBLE
CONNECTION
24" x 20" OR MINIMUM NET FREE AREA OF 480 SQ. INCHES
135.00° MIN.
R = W/2
R
DUCT SIZE ±25%
1/2" SCREEN
ANGLE RIVETED OR TACK
WELDED AS REQUIRED
WATERPROOF SEAMS AND JOINTS
ANGLE IRON
REINFORCING
WHERE REQ
BOLTS
MOTORIZED DAMPER; SEE PLANS &
SPECIFICATIONS
SECURE FAN TO CURB PER
MANUFACTURERS REQUIREMENTS
EXISTING ROOF CURB AND NEW CURB
ADAPTER AS REQUIRED
EXISTING FLASHING
NEW FLEXIBLE CONNECTION
ROOF STRUCTURE
REF-1
1/8" t/4
SAWCUT CONTROL JOINT
t = 6"
NOTES:
1. INSTALL CONTROL JOINTS SUCH THAT NO DIMEMSION BETWEEN JOINTS EXCEEDS 16' OR
3t MEASURED IN FEET, WHICHEVER IS LESSER (i.e. FOR A 4" THICK SLAB, MAX. CONTROL
JOINT SPACING = 3*4 = 12').
2. INSTALL CONTROL JOINTS SUCH THAT THE RECTANGULAR SECTIONS CREATED
BETWEEN THE JOINTS DO NOT EXCEED A 1:1.5 MAXIMUM RATIO (i.e. 10'x15' SECTION).
3. 6" SLAB SHOWN IS FOR TYPICAL CONSTRUCTION. ADJUST CONTROL JOINT DEPTH AND
SPACING BASED ON ACTUAL SLAB THICKNESS (t) PROVIDED.
4. PROVIDE 6" MIN. BETWEEN EQUIPMENT AND EDGE OF SLAB.
5. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3,000 PSI AT 28 DAYS.
6. WELDED WIRE FABRIC SHALL BE ASTM A1064. WELDED WIRE FABRIC WILL BE PLACED AT
MID DEPTH OF SLAB, UNLESS OTHERWISE NOTED.
7. ADDITION OF WATER TO READY-MIX IN THE FIELD SHALL NOT BE ALLOWED.
8. CONCRETE MUST BE CURED FOR A MINIMUM 21 DAYS PRIOR TO ANY ADHESIVE ANCHOR
INSTALLATION.
6" CONC. SLAB ON GRADE W/ 6x6-W2.9xW2.9 WWF.
SLOPE APPROPRIATELY FOR DRAINAGE
(COORDINATE WITH CIVIL)
EXISTING CONSTRUCTION
(PAVEMENT, WALL, ETC.)
1/2" EXPANSION MATERIAL
GRADE
COMPACTED SUBGRADE
CHAMFER AT
PERIMETER EDGES
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :1
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
M-501
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
M E
C H
A N
IC
A
L D
E T
A
IL
S
F T
B R
A G
G N
C
M E
C H
A N
IC
A
L
M
-5
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: NOT TO SCALEB3
TYP. FLEXIBLE CONNECTION
SCALE: NOT TO SCALEA1
EXHAUST RISER DIAGRAM
SCALE: NOT TO SCALEB5
SUPPLY RISER DIAGRAM
SCALE: NOT TO SCALEA2
MAU-1 WITH PAD DETAIL
SCALE: NOT TO SCALEA4
GOOSENECK DETAIL
SCALE: NOT TO SCALEC1
ROOFTOP (UPBLAST) EXHAUST FAN PITCHED ROOF
SCALE: NOT TO SCALED3
EQUIPMENT PAD DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
THROAT RADIUS
RADIUS 1
RADIUS 2
SPLITTER VANE
SPLITTER VANE
NOTE: SEE DUCT FITTING SCHEDULE FOR FITTING RADIUS DIMENSIONS
SINGLE THICKNESS
TURNING VANES
NOTE: SINGLE THICKNESS TYPE TURNING VANES RADIUS AND
SPACING SHALL BE PROVIDED PER THIS DETAIL.
R
S
R = 2.0" S = 1.5"
CONCRETE FASTENER
DOG HOUSE SIDE OF
CONCRETE WALL
OA OA
NOTE: ORIENTATION OF OUTSIDE AIR TRANSFER GRILLES SHALL DIRECT AIR AS SHOWN.
SUPPORT DIFFUSER
FROM STRUCTURE
WITH 20 GA. STRAPS
6" X 10" DEEP
CONTINUOUS SHEET
METAL PLENUM
GYPBOARD CEILING
LINE WHEN REQUIRED LINEAR SLOT DIFFUSER
FLEXIBLE SUPPLY AIR DUCT
SEE PLANS FOR SIZE AND
LOCATION. MAX. LENGTH 3'-0"
INSULATE PLENUM
AND DIFFUSER
SUPPORT FROM STRUCTURE TO
MINIMIZE SAGGING
INSULATED RIGID DUCT SEE
SCHEDULE FOR SIZE. DUCTWORK
TO MATCH GRILLE NECK.
DRAW BAND FOR FLEXIBLE DUCT
CONNECTION
GALVANIZED STEEL SMOOTH
RADIUS ELBOW
INSULATE ELBOW AND GRILLE
SUSPENDED CEILING
TRUNK DUCT
FLEX DUCT IS TO BE ATTACHED TO
SPIN-IN USING TAPE AND SHEET
METAL DRAW BAND WITH TIGHTENING
SCREW. SECURE DRAW BAND TO
SPIN-IN USING SHEET METAL SCREWS
SPIN-IN FITTING W/LOCKING
QUADRANT TYPE VOLUME DAMPER
AND SCOOP (SCOOP NOT REQUIRED
IN EXHAUST AND RETURN DUCT)
NOTE: SEE SPECIFICATIONS FOR INSULATION REQUIREMENTS
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :1
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
M-502
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
M E
C H
A N
IC
A
L D
E T
A
IL
S
F T
B R
A G
G N
C
M E
C H
A N
IC
A
L
M
-5
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: NOT TO SCALEB3
SMOOTH RADIUS ELBOW WITH SPLITTER VANES
SCALE: NOT TO SCALEA1
SINGLE THICKNESS VANE ELBOW DETAIL
SCALE: NOT TO SCALEA3
OUTSIDE AIR TRANSFER GRILLE DETAIL
SCALE: NOT TO SCALEC1
SLOT DIFFUSER DETAIL
SCALE: NOT TO SCALEC3
EXHAUST GRILLE DETAIL
SCALE: NOT TO SCALEB1
TYP. FLEXIBLE DUCT CONNECTION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
NOTES:
A LIMITED AMOUNT OF AVAILABLE CEILING AREA MAY REQUIRE THE CEILING BE CUT TO ACCOMMODATE A SMALL GRILLE FACE IN LAY-IN AS WELL AS SURFACE MOUNT. CONTRACTOR IS RESPONSIBLE FOR VERIFYING CEILING TYPE AND AVAILABLE SPACE WITH ARCHITECTURAL AND ELECTRICAL
DRAWINGS.
AIR DISTRIBUTION DESIGN WAS BASED ON TITUS FOR REFERENCE ONLY. AIR DISTRIBUTION BY NAILOR, PRICE, KRUEGER, METAL AIRE OR CARNES
ACCEPTABLE UPON APPROVAL.
AIR DISTRIBUTION CALL-OUT X ###
MARK CFM
1.
2.
3.
NOTES:
1. PROVIDE UNIT WITH ALL OF THE FOLLOWING FEATURES AND THOSE WITHIN THE SPECIFICATIONS:
A. SINGLE POINT POWER CONNECTION
B. VFD CONTROLLER FOR REMOTE LOCATION PER ELECTRICAL PLANS
C. REQUIRED CURB ADAPTER AND MOUNT PER MANUFACTURERS RECOMENDATIONS
D. STAINLESS STEEL FASTENERS - 300 SERIES
E. ALUMINUM BIRDSCREEN
F. BEARINGS WITH GREASE FITTINGS
G. ONE (1) SET OF SPARE BELTS (ATTACHED)
H. COATED WITH PERMATECTOR OR SIMILAR, FAN AND ATTACHED ACCESSORIES
2. BASIS OF DESIGN IS GREENHECK OR APPROVED EQUAL.
PROVIDE UNIT WITH ALL OF THE FOLLOWING FEATURES AND THOSE WITHIN THE SPECIFICATIONS:
A. TWO POINT POWER CONNECTION; ONE POINT FOR ELECTRIC HEATING COIL AND ONE POINT FOR REST OF UNIT
B. PROTECTIVE CAGE FOR CONDENSER COIL SECTION
C. SOUND ATTENUATION BLANKETS FOR COMPRESSORS
D. SMOKE DETECTOR AND SMOKE ALARM/DETECTION SAFETY FUNCTION
E. FOAM INJECTED PANELS
F. WITH DIRECT DRIVE FAN; ECM FAN OR VFD CONTROLLED FAN (PROVIDE VFD INTEGRAL TO UNIT FOR TAB OF UNIT)
G. LOW AND HIGH PRESSURE SAFETY SWITCHES
H. MINIMUM 6" CURB
I. BOTTOM SUPPLY DISCHARGE UNITS WITH CURB ADAPTORS TO CONVERT UNIT TO SIDE SUPPLY DISCHARGE J. A MINIMUM OF TWO (2) COMPRESSORS WITH A MINIMUM OF ONE (1) COMPRESSOR BEING VARIABLE SPEED OR DIGITAL SCROLL OPERATION
K. MODULATING HOT GAS REHEAT
MAKEUP AIR UNIT CONTROLS SHALL BE PROVIDED AND CAPABLE OF OPERATION PER THE SEQUENCE OF OPERATION (SEE SHEET M-701 FOR OPERATION AND MANUAL DRYING MODE).
BASIS OF DESIGN MANUFACTURER SHALL BE EQUIVALENT TO ADDISON PROH.
1.
2.
3.
NOTES:
NOTE:
1. SEE DETAIL B5 ON SHEET M-501.
NOTES:
1. TEST IN ACCORDANCE WITH SPECIFICATION UFGS 23 05 93, TESTING, ADJUSTING, AND BALANCING FOR HVAC AND THE
PROCEDURES IN SMACNA HVAC AIR DUCT LEAKAGE TEST MANUAL.
2. NO TEST REQUIRED.
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :1
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
M-601
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
M E
C H
A N
IC
A
L S
C H
E D
U L E
S
F T
B R
A G
G N
C
M E
C H
A N
IC
A
L
M
-6
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
AIR DISTRIBUTION SCHEDULE
MARK
SYSTEM
TYPE MFTR MODEL DESCRIPTION MATERIAL FINISH FACE AND NECK SIZE
MAX
NC FACE STYLE MOUNTING DAMPERS Count
1 SUPPLY AIR TITUS ML-39-4-22-3-01 3 SLOT,1" WIDTH ALUMINUM BROWN 48" x 7-3/4" FACE AND 8" NECK 30 LINEAR SLOT CEILING SURFACE NONE 14
A EXHAUST AIR TITUS 8F PERFORATED ALUMINUM BROWN 22" x 22" FACE AND 14" NECK 30 PERFORATED CEILING SURFACE NONE 7
B OUTSIDE AIR TITUS 350FL SINGLE DEFLECTION ALUMINUM BROWN 16" x 8" FACE AND NECK 30 35 DEGREE BLADES WALL SURFACE NONE 28
ROOFTOP EXHAUST FAN SCHEDULE
TYPE
AREA
SERVED
TOTAL
CFM
SP. IN.
WATER
WEIGHT
LBS
MOTOR DATA
TAG MFTR MODEL HP VOLTS PHASE HZ FLA
REF-1 GREENHECK CUBE-200-20 DUAL BELT DRIVE KENNEL 4,500 1.0 134 2 208 3 60 7.5
MAKEUP AIR UNIT SCHEDULE
AIR HANDLING SECTION COOLING SECTION HEATING SECTION (HEAT PUMP AND ELECTRIC)
V/PH/HZ FILTER UNIT WEIGHTTAG MFTR MODEL
TOTAL
CFM
O.A.
CFM AIR ENTR.
E.S.P.
I.W.G.
CAPACITY @97ºF (MBTUH)
EAT (ºF) LAT (ºF) (S)EER ∆T CAP.
HEATING
STAGES
HEAT
PUMP
(MBTUH) EAT (ºF) LAT (ºF)TOTAL SENS.
MAU-1 SEE NOTE 3 SEE NOTE 3 2,800 2,800 S: 97 DB/76.3 WB
W: 22 DB
1.75 221.8 136.9 97 DB/76.3 WB 53 DB/53 WB 12 50 55 KW SCR 151.7 22 72 208/3/60 MERV 8 2,500 LBS
DUCT FITTING SCHEDULE
MARK
FITTING
SIZE SYSTEM TYPE VANE QUANTITY
THROAT
RADIUS
SPLITTER VANE
RADIUS 1
SPLITTER VANE
RADIUS 2
SE-1 20x20-20x20 SUPPLY AIR 2 SPLITTER VANES 10" 13" 17"
SE-2 16x24-16x24 SUPPLY AIR 2 SPLITTER VANES 8" 10 1/2" 13 1/2"
SE-3 24x16-24x16 SUPPLY AIR 2 SPLITTER VANES 12" 15 1/2" 20 1/4"
REF-1 - - - - -2 - - A 12 2.0 1
MAU-1 2 - - - - 2 A 12 A 24 - - - - 2.0 1
SUPPLY
DUCT
RETURN
DUCT
EXHAUST
DUCT
OUTSIDE
AIR DUCT
DUCT
SEAL
CLASS
DUCT
LEAK
CLASS
DUCT
SEAL
CLASS
DUCT
LEAK
CLASS
INCHES OF WATER COLUM ROUND/OVAL RECTANGULAR
DUCT SEAL
CLASS
DUCT LEAK
CLASS
SYSTEM
DUCT PRESSURE CLASS SUPPLY EXHAUST/OUTSIDE AIR
DUCT TEST
PRESSURE:
INCHES OF
WATER
COLUMN
NOTES
DUCTWORK CONSTRUCTION AND LEAKAGE TESTING
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
TCU
VFD OR
ECM
CONTROL
OAT H
S S
NOTES:
1. DDC CONTROLS PROVIDED BY UNIT MANUFACTURER SHALL COMMUNICATE VIA LONWORKS.
2. SENSORS/TRANSMITTERS SHALL BE REQUIRED AS SHOWN AND ADDITIONAL AS REQUIRED TO PROVIDE FOR PROPER
UNIT OPERATION PER THE SEQUENCE OF OPERATION.
OUTDOOR AIR
F
IL
T E
R CONDITIONED
MAKEUP AIR TO
KENNEL SPACED
X C
O
IL
H G
R H
C O
IL
TO SBC
T S
T S
E L E
C T
R
IC
H E
A T
S C
R
H S
TS
RHS
LOCATE SENSORS WITHIN
EXHAUST AIR STREAM AS
SHOWN ON PLANS
DP
VFD
MAU-1
REF-1
PC TERMINAL
EXISTING
SBC
LAN
ES
MAU-1
INSTALL PER PLAN
SHEET M-101
REF-1
32273
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
P A
U
L
C . M A H A F
F
E Y
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:4 :1
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
J R
P
J R
P
M A
L
M-701
W
IL
M I N
G T
O N
D
IS
T R
IC
T
P C
M
C O
N T
R O
L S
A N
D O
P E
R A
T
IO
N
F T
B R
A G
G N
C
M E
C H
A N
IC
A
L
M
-7
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: NOT TO SCALEB1
MAKEUP AIR UNIT (MAU-1) AND ROOFTOP EXHAUST FAN (REF-1) CONTROL DIAGRAM
SCALE: NOT TO SCALEC1
SYSTEM NETWORK
THE KENNEL SPACE CONSISTS OF A CONDITIONING/DEHUMIDIFICATION PACKAGED MAKEUP AIR SYSTEM. NEW CONTROL SYSTEM SHALL
COMMUNICATE WITH BASE WIDE LONWORKS MONITORING SYSTEM.
MAKEUP AIR UNIT (MAU-1):
A PROGRAMMABLE CONTROLLER CAPABLE OF STANDALONE OPERATION WILL CONTROL THE MAKEUP AIR UNIT (MAU), SUBJECT TO OCCUPANCY SCHEDULES AND OCCUPANCY OVERRIDES THROUGH THE SUPERVISORY BUILDING CONTROLLER (SBC).
GENERAL: THE MAU CONSISTS OF A FAN HOUSING, A DIRECT EXPANSION (DX) COIL WITH MODULATING HOT GAS REHEAT (HGRH), AND ELECTRIC HEAT WITH SCR MODULATION PRETREATING OUTDOOR AIR CONTROLLED THROUGH THE DDC SYSTEM. THE MAU IS A PACKAGED
UNIT WITH A CONDENSING COIL, FAN, AND VARIABLE SPEED COMPRESSOR.
THE SEQUENCE OF OPERATION SHALL BE INITIATED BY THE DDC SYSTEM SCHEDULE.
DURING KENNEL UNOCCUPIED MODE, THE UNIT FAN SHALL BE DE-ENERGIZED.
DURING KENNEL OCCUPIED MODE, THE UNIT FAN SHALL RUN CONTINUOUSLY, THE DX COIL, HRGH COIL, COMPRESSOR, AND ELECTRIC HEAT (SCR) SHALL MODULATE AS NEEDED BASED ON TEMPERATURE AND HUMIDITY AS MONITORED WITHIN THE EXHAUST AIRSTREAM.
HUMIDITY AND TEMPERATURE CONTROL REQUIREMENTS: KENNEL SPACE HUMIDITY AND TEMPERATURE WILL BE CONTROLLED THROUGH THE SBC. IN COOLING MODE THE UNIT SHALL MAINTAIN A MAXIMUM SPACE TEMPERATURE OF 80°F. IN HEATING MODE THE UNIT SHALL MAINTAIN A MINIMUM SPACE TEMPERATURE OF 45°F. DURING ALL OPERATING MODES, THE UNIT SHALL MAINTAIN KENNEL SPACE TEMPERATURE AT ±10°F AMBIENT TEMPERATURE AND MAXIMUM OF 55% RELATIVE HUMIDITY (RH) THROUGH AUTOMATIC MODULATION AND CONTROL.
ECONOMIZER MODE: UNIT SHALL PROVIDE NO AIR CONDITIONING OR HEATING DURING THIS MODE. UNIT SHALL BE IN ECONOMIZER MODE DURING THE FOLLOWING KENNEL SPACE CONDITIONS: TEMPERATURE IS ABOVE 45°F AND BELOW 80°F; RELATIVE HUMIDITY IS BELOW 55% RH.
HEATING MODE: UNIT SHALL HEAT AIR AS NEEDED TO MAINTAIN KENNEL SPACE TEMPERATURE PER TEMPERATURE CONTROL REQUIREMENTS ABOVE. UNIT SHALL BE IN HEATING MODE WHEN KENNEL SPACE TEMPERATURE IS 45°F OR BELOW.
DEHUMIDIFICATION MODE: UNIT SHALL CONDITION AND DEHUMIDIFY OUTSIDE AIR TO PROVIDE AN AMBIENT NEUTRAL DRY BULB DISCHARGE AIR CONDITION. THIS MODE SHALL MAINTAIN KENNEL SPACE RELATIVE HUMIDITY TO A MAXIMUM OF 55% RH WITH A KENNEL SPACE TEMPERATURE OF ±10°F AMBIENT TEMPERATURE. UNIT SHALL BE IN DEHUMIDIFICATION MODE WHEN KENNEL SPACE RELATIVE HUMIDITY IS GREATER THAN
55% RH AND KENNEL SPACE TEMPERATURE IS IN THE RANGE OF 46°F TO 79°F.
COOLING MODE: UNIT SHALL CONDITION AND DEHUMIDIFY OUTSIDE AIR TO PROVIDE A MODULATING DISCHARGE AIR CONDITION TO MAINTAIN KENNEL SPACE TEMPERATURE PER TEMPERATURE CONTROL REQUIREMENTS ABOVE. UNIT SHALL BE IN COOLING MODE WHEN KENNEL SPACE TEMPERATURE IS 80°F OR ABOVE AND KENNEL SPACE RELATIVE HUMIDITY IS LESS THAN 55%.
COOLING AND DEHUMIDIFICATION MODE: UNIT SHALL CONDITION AND DEHUMIDIFY OUTSIDE AIR TO PROVIDE A DISCHARGE AIR CONDITION TO MAINTAIN KENNEL SPACE TEMPERATURE BELOW 80°F AND 55% RH. UNIT SHALL BE IN THIS MODE WHEN KENNEL SPACE TEMPERATURE IS 80°F
DB OR GREATER AND RELATIVE HUMIDITY IS 55% RH OR GREATER.
MANUAL DRYING MODE: MODE SHALL BE INITIATED BY USER INPUT CONTROL (I.E., WALL MOUNTED DDC TOUCHSCREEN CONTROLLER). MODE DURATION SHALL BE AN ADJUSTABLE SETTING AT THIS CONTROLLER WITH 15 MINUTE INCREMENTS AND A MAXIMUM DURATION OF 1 HOUR 15 MINUTES. WHEN MANUAL DRYING MODE IS INITIATED, UNIT SHALL CONDITION AND DEHUMIDIFY OUTSIDE AIR TO PROVIDE THE FOLLOWING
CONDITIONS BASED ON THE CURRENT OUTSIDE AIR CONDITION:
OUTSIDE AIR CONDITION MAU-1 DISCHARGE CONDITION
GREATER THAN 80°F DB DEHUMIDIFICATION AND HEATING: 110.0°F DB/72.7°F WB
61°F DB TO 80°F DB DEHUMIDIFICATION AND HEATING: 110.0°F DB/77.0°F WB
54°F DB TO 60°F DB COOLING COIL LAT: 53°F DB/53°F WB; REHEAT/HEATING COIL LAT: 103°F DB
LESS THAN 54°F DB OUTSIDE AIR °F DB + 50°F DB (NO DEHUMIDIFICATION)
REMOTE DDC TOUCHSCREEN CONTROLLER: CONTROLLER SHALL PROVIDE FOR USER INPUT FOR MANUAL DRYING MODE AND ALSO DISPLAY THE FOLLOWING PARAMETERS: MANUAL DRYING MODE TIME REMAINING WHEN ACTIVE, CURRENT MAU-1 OPERATING MODE (E.G., COOLING MODE, HEATING MODE, ETC.), MAU-1 DISCHARGE AIR TEMPERATURE, KENNEL SPACE TEMPERATURE AND RELATIVE HUMIDITY (FROM EXHAUST
DUCT SENSORS), AND OUTSIDE AIR TEMPERATURE (FROM MAU-1 INTAKE AIR STREAM).
CONTROLLER SHALL BE WALL MOUNTED PER SHEET M-101 AND WELL SUITED FOR DAMP ENVIRONMENTS (I.E., WATER RESISTANT WITH
PROTECTIVE WATER TIGHT ENCLOSURE).
SAFETIES: UPON AN ALARM SIGNAL FROM THE SUPERVISORY BUILDING CONTROLLER (SBC) THE UNIT SHALL DE-ENERGIZE AND ALL ASSOCIATED MOTOR OPERATED DAMPERS IN THE OUTDOOR AIR STREAMS SHALL CLOSE. THIS SHALL REQUIRE A RESET AT THE SUPERVISORY CONTROLLER OR A REMOTE RESET FROM THE EMCS (EMERGENCY MONITORING AND CONTROLS SYSTEM). AT A MINIMUM INCORPORATE HIGH AND LOW PRESSURE SAFETY SWITCHES INTO THE DDC SYSTEM FOR BASE WIDE MONITORING.
WHEN OPERATING STATUS OF UNIT IS NOT PROVEN THE CONTROLLER SHALL DE-ENERGIZE THE UNIT AND AN ALARM SHALL BE DISPLAYED AT
THE OPERATOR'S WORKSTATION.
ROOFTOP EXHAUST FAN (REF-1):
GENERAL: THE UNIT IS A ROOFTOP EXHAUST FAN. FAN OPERATION SHALL BE CONTROLLED THROUGH THE DDC SYSTEM.
DURING KENNEL UNOCCUPIED MODE, THE EXHAUST FAN SHALL BE DE-ENERGIZED.
DURING KENNEL OCCUPIED MODE, THE EXHAUST FAN SHALL RUN CONTINUOUSLY.
FAN SHALL BE PROVIDED WITH A VFD TO BE LOCATED AND INSTALLED PER ELECTRICAL PLANS. FAN SHALL BE PROVIDED FOR TEST AND BALANCE (TAB) PURPOSES TO ENSURE PROPER SYSTEM AIRFLOW. ONCE TAB SERVICES ARE PERFORMED AND SYSTEM AIRFLOWS ARE SET PER PLAN SHEET M-101, VFD SETPOINT SHALL BE SET AND LOCKED WITHIN DDC CONTROL LOGIC.
SAFETIES: UPON AN ALARM SIGNAL FROM THE SUPERVISORY BUILDING CONTROLLER (SBC) THE UNITS SHALL DE-ENERGIZE AND ALL ASSOCIATED MOTOR OPERATED DAMPERS IN THE EXHAUST AIR STREAMS SHALL CLOSE. THIS SHALL REQUIRE A RESET AT THE SUPERVISORY CONTROLLER OR A REMOTE RESET FROM THE EMCS (EMERGENCY MONITORING AND CONTROLS SYSTEM).
EMERGENCY SHUTDOWN:
UPON AN EMERGENCY SHUTDOWN CALL FROM THE SUPERVISORY BUILDING CONTROLLER OR BUILDING MASS NOTIFICATION SYSTEM, ALL UNITS SHALL BE DE-ENERGIZED AND ALL OUTSIDE AIR AND EXHAUST MOTOR OPERATED DAMPERS SHALL BE CLOSED. THIS SHALL REQUIRE A RESET AT THE SUPERVISORY CONTROLLER OR A REMOTE RESET FROM THE EMCS (EMERGENCY MONITORING AND CONTROLS SYSTEM). SEE
SHEET M-101 FOR LOCATION OF HVAC EMERGENCY SHUTDOWN PUSH BUTTON.
SUPERVISORY BUILDING CONTROLLER:
SUPERVISORY BUILDING CONTROLLER SHALL COMMUNICATE WITH FORT BRAGG, NC BASE WIDE MONITORING SYSTEM.
SEQUENCE OF OPERATION:
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
PHASE II
PHASE I
REF-1
PANEL AP,
SECT 2
PANEL AP,
SECT 1
PANEL
MDP
DE1
DE2
DE2
DE4
DE3
MAUDE5
MDP-(14,16,18)
DE3DE3DE3
DE3
DE3 DE3 DE3 DE3 DE3 DE3 DE3 DE3
DE3
DE3 DE3 DE3 DE3
DE6
E
E
E
E
E E
E
EE
E
E
E E
E E
E
E
E
E
E
E e
GENERAL NOTES:
1. CONTRACTOR TO SCHEDULE WITH FACILITY
USERS OUTAGES FOR PANEL WORK 48 HOURS
PRIOR TO OUTAGE.
10475
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
O N
R O
I
GNOB.I
Y
R N
E H
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:2 :0
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
H
IB
C R
C
M A
L
ED101
W
IL
M I N
G T
O N
D
IS
T R
IC
T
H
IB
E L E
C T
R
IC
A L D
E M
O L
IT
IO
N
P L A
N
F T
B R
A G
G N
C
E L E
C T
R
IC
A L
E
D
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: 1/8" = 1'-0"B1
ELECTRICAL DEMOLITION PLAN
DEMOLITION KEYNOTES:
NO. DESCRIPTION
DE1 REMOVE EXISTING MOTOR DISCONNECT FOR
REF-1.
DE2 REMOVE EXISTING SINGLE PHASE CIRCUIT
BREAKER IN PANEL AP-1 FOR EF-104.
RE-ARRANGE SPARE CIRCUIT BREAKER TO
ALLOW FOR INSTALLATION OF A NEW 20AMP-3P
CIRCUIT BREAKER. REMOVE CONDUIT AND
CONDUCTORS FROM AP-1 AND CUT CONDUIT AT
2' ABOVE PANEL.
DE3 REMOVE SURFACE MOUNT LIGHT FIXTURES
DURING EACH PHASE OF CEILING DEMOLITION.
TERMINATE FEEDER CONDUCTORS AND
INSTALL TEMPORARY JUNCTION BOX COVER.
STORE FIXTURES.
DE4 REMOVE EXISTING 125AMP-3PHASE CIRCUIT
BREAKER IN PANEL MDP.
DE5 REMOVE MAU FEEDER CONDUCTORS,
EXPOSED CONDUIT, AND DISCONNECT.
DE6 REMOVE EXISTING CIRCUIT EQUIPMENT FOR
DUCT HEATER.
NOT IN SCOPE
KEY PLAN
PLAN NORTH
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
E
E
E
E
E E
E
EE
E
E
E E
E
E E
E
E
E
E
E
E
E
REF-1
PANEL AP,
SECT 2
PANEL AP,
SECT 1
PANEL
MDP
E1
E3
E5
E4
MAU-1E6
MDP-(26,28,30)
E4E4
E4
E4
E4
E4 E4 E4 E4
E4
E4
E4 E4 E4E4 E4 E4
VFD E2
E3
PHASE II
PHASE I
MAU-1HE8
MDP-(8,10,12)
E7 e
PANEL
AP-1
REMOVE CONDUIT
NEW JUNCTION BOX
EXISTING CONDUIT
TO REF-1
NEW 3/4" CONDUIT
NEW
VFD
GENERAL NOTES:
1. CONTRACTOR TO SCHEDULE WITH FACILITY
USERS OUTAGES FOR PANEL WORK 48 HOURS
PRIOR TO OUTAGE.
EQUIPMENT DISCONNECT
MAU-1H
MAU-1
FEEDER
EQUIPMENT SCHEDULE
REF-1
3#2/0, #6G, 2"C
3#3/0, #6G, 2"C
3#12, #12G, 3/4"C
200/NF/3/3R
200/NF/3/3R
30/NF/3/3R
10475
N
O
RT
H CAROLIN
A
P
RO
FESS I ONAL
SEAL
E
N G
I N E E
R
O N
R O
I
GNOB.I
Y
R N
E H
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C K
D B
Y
US Army Corps of Engineers ® x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
IT
E
C T
U R
E C
E M
S P ro je c t N o
X
P ro je c t M a n a g e r:
M a rk
L a z o
A S
S H
O W
N
3-31-15
/3
/2
:2 :0
P
M
R E
P A
IR
K
E N
N E
L F
A C
IL
IT
Y B
U
IL
D
IN
G O
X S
F G
M F
-0 -4
P
M
A R
C H
Wilmington District
H
IB
C R
C
M A
L
E-101
W
IL
M I N
G T
O N
D
IS
T R
IC
T
H
IB
E L E
C T
R
IC
A L N
E W
W O
R K
P L A
N
F T
B R
A G
G N
C
E L E
C T
R
IC
A L
E
-1
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: 1/8" = 1'-0"B1
ELECTRICAL NEW WORK PLAN
NEW WORK KEYNOTES:
NO. DESCRIPTION
E1 INSTALL NEW 30AMP-3POLE, NEMA 3R
NON-FUSED DISCONNECT. CONNECT TO
EXISTING REF-1 CONDUIT AND NEW 3PHASE
FEEDER CONDUCTORS.
E2 INSTALL NEW REF-1 VFD ADJACENT TO PANEL
AP-1. INSTALL 3#12CU, #12G IN 3/4" CONDUIT
FROM NEW 3POLE CIRCUIT BREAKER IN AP-1 TO
NEW VFD CONTROLLER. ELECTRICAL
CONTRACTOR TO INSTALL VFD PROVIDED BY
MECHANICAL CONTRACTOR.
E3 INSTALL JUNCTION BOX ON EXISTING REF-1
FEEDER CONDUIT (REMOVED FROM AP-1) AND
PROVIDE NEW 3/4" CONDUIT TO NEW VFD.
INSTALL TWO ADDITIONAL PHASE
CONDUCTORS FROM JUNCTION BOX TO NEW
REF-1 DISCONNECT. INSTALL 3PHASE
CONDUCTORS TO VFD FROM JUNCTION BOX.
E4 REMOVE TEMPORARY JUNCTION BOX COVERS
AND INSTALL STORED FIXTURES AFTER CEILING
IS REPLACED.
E5 INSTALL A NEW 200AMP-3POLE CIRCUIT
BREAKER IN SPARE LOCATION FOR MAU
COMPRESSOR.
E6 INSTALL NEW 3#3/0CU, #6G IN NEW 2" CONDUIT
TO NEW 200AMP-3POLE, NEMA 3R NON-FUSED
DISCONNECT AT NEW MAU. CONDUIT TO BE
EXPOSED ON WALL AND CEILING OF
ELECTRICAL AND MECHANICAL ROOMS AND
DIRECT BURIED ON THE EXTERIOR TO UNIT
DISCONNECT. PROVIDE FLEXIBLE WEATHER
TIGHT METAL CONDUIT TO UNIT. BREAKER TO
BE HACR RATED.
E7 INSTALL 175AMP-3POLE CIRCUIT BREAKER IN
LOCATION OF REMOVED CIRCUIT BREAKER TO
FEED MAU ELECTRIC HEAT.
E8 INSTALL NEW 3#2/0, #6G IN 2"C FROM MDP TO
NEW 200AMP-3POLE, NEMA 3R NON-FUSED
DISCONNECT SWITCH FOR ELECTRIC HEAT.
NOT IN SCOPE
KEY PLAN
PLAN NORTH
164 8268
SCALE: 1/8"=1'-0"
GRAPHIC SCALE
SCALE: NOT TO SCALEA1
CIRCUITRY CHANGE FOR REF-1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
| General |
| G-001 - COVER SHEET |
| Architechtural |
| AD121 - REFLECTED CEILING DEMOLITION PLAN |
| A-121 - REFLECTED CEILING NEW WORK PLAN |
| A-301 - BUILDING SECTIONS & INTERIOR ELEVATIONS |
| Fire Protection |
| FD101 - FIRE PROTECTION DEMOLITION PLAN |
| FS001 - FIRE PROTECTION GENERAL NOTES & LEGENDS |
| FS101 - FIRE PROTECTION NEW WORK PLAN |
| Plumbing |
| P-001 - GENERAL NOTES AND LEGENDS |
| PD101 - PLUMBING DEMOLITION PLAN |
| P-101 - PLUMBING NEW WORK PLAN |
| P-501 - PLUMBING DETAIL AND SCHEDULE |
| Mechanical |
| M-001 - GENERAL NOTES & LEGENDS |
| MD101 - MECHANICAL DEMOLITION PLAN |
| M-101 - MECHANICAL NEW WORK PLAN |
| M-501 - MECHANICAL DETAILS |
| M-502 - MECHANICAL DETAILS |
| M-601 - MECHANICAL SCHEDULES |
| M-701 - CONTROLS AND OPERATION |
| Electrical |
| ED101 - ELECTRICAL DEMOLITION PLAN |
| E-101 - ELECTRICAL NEW WORK PLAN |
File details come from the government source that posted it. Updated .