AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

Solicitation W912PM-14-B-0008 is hereby amended for the follow ing reason:

a) To provide required revisions to the plans and specifications as show n on the Technical Summary of Changes attached hereto.

b) All other terms and contitions remain unchanged.

c) The time and date for receipt of proposals is NOT extended.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 2

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 05-Sep-2014

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912PM-14-B-0008

X 9B. DATED (SEE ITEM 11)

13-Aug-2014

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

04-Sep-2014

CODE

U S ARMY CORPS OF ENGINEERS

WILMINGTON DISTRICT

ATTN: CONTRACTING DIVISION

69 DARLINGTON AVE

WILMINGTON NC 28403-1343

W912PM 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912PM-14-B-0008

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SECTION 00 00 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

SUMMARY OF CHANGES

PN: SC-00002-4P

Amendment 0002

Technical Summary of Changes

01 33 00 – SUBMITTAL PROCEDURES

Delete existing Attachment 1, Page 5 of 18 and 6 of 18 in their entirety and replace with revised enclosed Pages.

08 33 23 – OVERHEAD COILING DOORS

Delete existing Pages 1 thru 13 in their entirety and replace with revised enclosed Pages.

NOTE:

Text that is added or revised by this amendment is identified with ***Amendment 0002(beginning and ending of revision/addition) and/or printed in bold. (Red

Strike through – DELETE).

The text changes may have necessitated reformatting of subsequent text or pages. If this is the case, those pages have also been issued as amended pages but are not underlined or bold text.

DRAWIINGS

Delete existing Sheet Numbers 018 and 030 in their entirety and replace with revised enclosed Sheets.

-- End of Summary of Changes- -

Encls As Stated

SUBMITTAL REGISTER (ER 415-1-10) TITLE AND LOCATION DATE

CONTRACTOR CONTRACT NUMBER

ACTIVITY

No.

TRANS-

MITTAL

No.

ITEM

No.

SPEC

PARAGRAPH

No.

DESCRIPTION OF

SUBMITTAL

TYPE OF SUBMITTAL

CLASSI-

FICATION

FIO

GA, DA

or CR

REVIEWER

OFFICE / NAME

CONTRACTOR

SCHEDULE DATES

CONTRACTOR

ACTION

GOVERNMENT

ACTION

SUBMIT

NEEDED

BY

APPROVAL

NEEDED

BY

MATERIAL

NEEDED

BY

CODE

CORPS

RECEIVED

DATE

CODE

CORPS

RETURNED

DATE

SC-00002-4P Construct Storage Facility

W912PM-14-B-0008 NA

4 Sep 2014

SORT : SECTION & ITEMRANGE : ALL

24 05 52 00 3.1 Installation Instructions MFRS INSTR GA

SECTION - 06 10 00 ROUGH CARPENTRY

1 06 10 00 2.2.1 Nailing Strips SHOP DRAWINGS GA

2 06 10 00 1.7 Fire-retardant treatment PRODUCT DATA FIO

SECTION - 08 11 13 STEEL DOORS AND FRAMES

1 08 11 13 2.1 Doors SHOP DRAWINGS GA

2 08 11 13 2.1 Doors SHOP DRAWINGS GA

3 08 11 13 2.6 Frames SHOP DRAWINGS GA

4 08 11 13 2.6 Frames SHOP DRAWINGS GA

5 08 11 13 2.4 Accessories SHOP DRAWINGS FIO

6 08 11 13 1.2 Submit door and frame locations SHOP DRAWINGS GA

7 08 11 13 2.6 Frames PRODUCT DATA GA

8 08 11 13 2.4 Accessories PRODUCT DATA FIO

9 08 11 13 1.2 Factory-applied enamel finish SAMPLES GA

SECTION - 08 33 23 OVERHEAD COILING DOORS

1 08 33 23 2.3 Overhead Coiling Doors SHOP DRAWINGS GA

2 08 33 23 1.4 Counterbalancing Mechanism SHOP DRAWINGS GA

3 08 33 23 2.5 Counterbalancing Mechanism SHOP DRAWINGS GA

4 08 33 23 1.4 Electric Door Operators SHOP DRAWINGS GA

5 08 33 23 2.6 Electric Door Operators SHOP DRAWINGS GA

6 08 33 23 2.3.3 Bottom Bars SHOP DRAWINGS GA

7 08 33 23 1.3 Guides SHOP DRAWINGS GA

8 08 33 23 2.5.1 Mounting Brackets SHOP DRAWINGS GA

9 08 33 23 1.2 Overhead Drum SHOP DRAWINGS GA

10 08 33 23 1.4 Hood SHOP DRAWINGS GA

11 08 33 23 1.4 Painting SHOP DRAWINGS GA

12 08 33 23 1.3 Installation Drawings SHOP DRAWINGS GA

13 08 33 23 2.3 Overhead Coiling Doors PRODUCT DATA GA

14 08 33 23 2.4 Hardware PRODUCT DATA GA

15 08 33 23 1.4 Counterbalancing Mechanism PRODUCT DATA GA

16 08 33 23 2.5 Counterbalancing Mechanism PRODUCT DATA GA

17 08 33 23 1.4 Electric Door Operators PRODUCT DATA GA

18 08 33 23 2.6 Electric Door Operators PRODUCT DATA GA

19 08 33 23 2.3 Overhead Coiling Doors DESIGN DATA GA

20 08 33 23 2.4 Hardware DESIGN DATA GA

Page 5 of 18 (Revised by Amendment 0002)

K7EPEOAF

Cross-Out

K7EPEOAF

Cross-Out

K7EPEOAF

Cross-Out

SUBMITTAL REGISTER (ER 415-1-10) TITLE AND LOCATION DATE

CONTRACTOR CONTRACT NUMBER

ACTIVITY

No.

TRANS-

MITTAL

No.

ITEM

No.

SPEC

PARAGRAPH

No.

DESCRIPTION OF

SUBMITTAL

TYPE OF SUBMITTAL

CLASSI-

FICATION

FIO

GA, DA

or CR

REVIEWER

OFFICE / NAME

CONTRACTOR

SCHEDULE DATES

CONTRACTOR

ACTION

GOVERNMENT

ACTION

SUBMIT

NEEDED

BY

APPROVAL

NEEDED

BY

MATERIAL

NEEDED

BY

CODE

CORPS

RECEIVED

DATE

CODE

CORPS

RETURNED

DATE

SC-00002-4P Construct Storage Facility

W912PM-14-B-0008 NA

4 Sep 2014

SORT : SECTION & ITEMRANGE : ALL

21 08 33 23 1.4 Counterbalancing Mechanism DESIGN DATA GA

22 08 33 23 2.5 Counterbalancing Mechanism DESIGN DATA GA

23 08 33 23 1.4 Electric Door Operators DESIGN DATA GA

24 08 33 23 2.6 Electric Door Operators DESIGN DATA GA

25 08 33 23 3.3 Operation and Maintenance Manuals O&M DATA GA

26 08 33 23 1.4 Materials O&M DATA GA

27 08 33 23 1.4 Devices O&M DATA GA

28 08 33 23 1.4 Procedures O&M DATA GA

29 08 33 23 1.4 Manufacture's Brochures O&M DATA GA

30 08 33 23 1.4 Parts Lists O&M DATA GA

31 08 33 23 3.2.2 Cleaning O&M DATA GA

SECTION - 08 71 00 DOOR HARDWARE

1 08 71 00 1.3 Hardware schedule SHOP DRAWINGS FIO

2 08 71 00 2.3.5 Keying system SHOP DRAWINGS FIO

3 08 71 00 2.3 Hardware items PRODUCT DATA FIO

4 08 71 00 3.1 Installation MFRS INSTR FIO

5 08 71 00 1.3 Hardware Schedule O&M DATA FIO

6 08 71 00 1.4 Key Bitting CLOSEOUT SUBMTL FIO

SECTION - 09 05 61 COMMON WORK RESULTS FOR FLOORING PREPARATION

1 09 05 61 1.5 Visual Observation Report PRECON SUBMTL GA

2 09 05 61 1.5 Floor Covering and Adhesive Manufacturer SHOP DRAWINGS GA

3 09 05 61 1.5 Testing Agency's Report PRODUCT DATA GA

SECTION - 09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD

1 09 22 00 2.1 Metal support systems SHOP DRAWINGS GA

SECTION - 09 29 00 GYPSUM BOARD

1 09 29 00 1.2 Cementitious backer units PRODUCT DATA FIO

2 09 29 00 2.1.4 Glass Mat Water-Resistant Gypsum Tile Ba PRODUCT DATA FIO

3 09 29 00 2.1.3 Water-Resistant Gypsum Backing Board PRODUCT DATA FIO

4 09 29 00 1.2 Glass Mat Covered or Reinforced Gypsum S PRODUCT DATA FIO

5 09 29 00 1.2 Glass Mat Covered or Reinforced Gypsum S PRODUCT DATA FIO

6 09 29 00 2.1.5 Impact Resistant Gypsum Board PRODUCT DATA FIO

7 09 29 00 2.1.9 Accessories PRODUCT DATA FIO

8 09 29 00 1.2 Certification PRODUCT DATA FIO

9 09 29 00 2.1.1 Gypsum Board PRODUCT DATA FIO

10 09 29 00 2.1.8 Adhesives PRODUCT DATA FIO

Page 6 of 18 (Revised by Amendment 0002)

Construct Storage Facility JSOC / Pope AAF (SC-0002-4P) W912PM-14-B-0008

SECTION TABLE OF CONTENTS

DIVISION 08 - OPENINGS

SECTION 08 33 23

OVERHEAD COILING DOORS

PART 1 GENERAL

1.1 REFERENCES

1.2 SUBMITTALS

1.3 OVERHEAD COILING DOOR DETAIL SHOP DRAWINGS

1.4 WARRANTY, OPERATION AND MAINTENANCE DATA

1.5 DELIVERY AND STORAGE

PART 2 PRODUCTS

2.1 DESCRIPTION

2.2 PERFORMANCE REQUIREMENTS

2.2.1 Wind Loading

2.2.2 Operational Cycle Life

2.3 OVERHEAD COILING DOORS

2.3.1 Curtain Materials and Construction

2.3.2 Insulated Curtains

2.3.3 Curtain Bottom Bar

2.3.4 Locks

2.3.5 Weather Stripping

2.3.6 Locking Devices

2.4 HARDWARE

2.4.1 Guides

2.4.2 Equipment Supports

2.5 COUNTERBALANCING MECHANISM

2.5.1 Brackets

2.5.2 Counterbalance Barrels

2.5.2.1 Spring Balance

2.5.3 Spring Balance

2.5.4 Torsion Rod for Counter Balance

***AMENDMENT 0002***

2.6 ELECTRIC DOOR OPERATORS

***AMENDMENT 0002***

2.7 SURFACE FINISHING

PART 3 EXECUTION

3.1 GENERAL

3.2 ACCEPTANCE PROVISIONS

3.2.1 Maintenance and Adjustment

3.2.2 CLEANING

3.3 OPERATION AND MAINTENANCE

-- End of Section Table of Contents --

SECTION 08 33 23 Page 1 (Revised by Amendment 0002)

SECTION 08 33 23

OVERHEAD COILING DOORS

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)

ASCE 7 (2010; Errata 2011; Supp 1 2013) Minimum Design Loads for Buildings and Other Structures

AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING

ENGINEERS (ASHRAE)

ASHRAE FUN IP (2013) Fundamentals Handbook, I-P Edition

***AMENDMENT 0002***

ASME INTERNATIONAL (ASME)

ASME B29.400 (2001; R 2013) Combination, "H" Type Mill Chains, and Sprockets

***AMENDMENT 0002***

ASTM INTERNATIONAL (ASTM)

ASTM A153/A153M (2009) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware

ASTM A27/A27M (2013) Standard Specification for Steel Castings, Carbon, for General Application

ASTM A307 (2012) Standard Specification for Carbon Steel Bolts and Studs, 60 000 PSI Tensile Strength

ASTM A36/A36M (2012) Standard Specification for Carbon Structural Steel

ASTM A48/A48M (2003; R 2012) Standard Specification for Gray Iron Castings

ASTM A53/A53M (2012) Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless

ASTM A653/A653M (2013) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or

SECTION 08 33 23 Page 2 (Revised by Amendment 0002)

Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM A666 (2010) Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate and Flat Bar

ASTM A780/A780M (2009) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings

ASTM A924/A924M (2013) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process

ASTM B221 (2013) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes

ASTM D2000 (2012) Standard Classification System for Rubber Products in Automotive Applications

ASTM E330 (2002; R 2010) Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference

ASTM E84 (2013a) Standard Test Method for Surface Burning Characteristics of Building Materials

ASTM F568M (2007) Standard Specification for Carbon and Alloy Steel Externally Threaded Metric Fasteners

***AMENDMENT 0002***

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

NEMA ICS 2 (2000; R 2005; Errata 2008) Standard for Controllers, Contactors, and Overload Relays Rated 600 V

NEMA ICS 6 (1993; R 2011) Enclosures

NEMA MG 1 (2011; Errata 2012) Motors and Generators

NEMA ST 1 (1988; R 1994; R 1997) Specialty Transformers (Except General Purpose Type)

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 70 (2014; AMD 1 2013; Errata 1 2013; AMD 2 2013; Errata 2 2013) National Electrical Code

NFPA 80 (2013) Standard for Fire Doors and Other Opening Protectives

***AMENDMENT 0002***

SECTION 08 33 23 Page 3

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

***AMENDMENT 0002***

SD-02 Shop Drawings

Overhead Coiling Doors; G

Counterbalancing Mechanism; G

Electric Door Operators; G

Bottom Bars; G

Guides; G

Mounting Brackets; G

Overhead Drum; G

Hood; G

Painting; G

Installation Drawings; G

SD-03 Product Data

Overhead Coiling Doors; G

Hardware; G

Counterbalancing Mechanism; G

Electric Door Operators; G

SD-05 Design Data

Overhead Coiling Doors; G

Hardware; G

Counterbalancing Mechanism; G

Electric Door Operators; G

***AMENDMENT 0002***

SD-10 Operation and Maintenance Data

SECTION 08 33 23 Page 4

Operation and Maintenance Manuals; G

Materials; G

Devices; G

Procedures; G

Manufacture's Brochures; G

Parts Lists; G

Cleaning; G

1.3 OVERHEAD COILING DOOR DETAIL SHOP DRAWINGS

Provide installation drawings for overhead coiling door assemblies which show: elevations of each door type, shape and thickness of materials, finishes, details of joints and connections, details of guides and fittings, rough opening dimensions, location and description of hardware, anchorage locations, and counterbalancing mechanism and door operator details. Include a schedule showing the location of each door with the drawings.

1.4 WARRANTY, OPERATION AND MAINTENANCE DATA

Submit Operation and Maintenance Manuals for Overhead Coiling Door Assemblies, including the following items:

***AMENDMENT 0002***

Materials

Devices

Electric Door Operators

Hood

Counterbalancing Mechanism

Painting

Procedures

Manufacture's Brochures

Parts Lists

***AMENDMENT 0002***

Furnish a written guarantee that the helical spring and counterbalance mechanism are free from defects in material and workmanship for not less than two years after completion and acceptance of the project.

Warrant that upon notification by the Government, any defects in material, workmanship, and door operation are immediately correct within the same time period covered by the guarantee, at no cost to the Government.

SECTION 08 33 23 Page 5

1.5 DELIVERY AND STORAGE

Deliver doors to the jobsite wrapped in a protective covering with the brands and names clearly marked thereon. Store doors in an adequately ventilated dry location that is free from dirt and dust, water, or other contaminants. Store in a manner that permits easy access for inspection and handling.

PART 2 PRODUCTS

2.1 DESCRIPTION

Doors to be coiling type, with interlocking slats, complete with anchoring and door hardware, guides, hood, and operating mechanisms, and designed for use on openings as indicated. Use grease-sealed or self-lubricating bearings for rotating members.

2.2 PERFORMANCE REQUIREMENTS

2.2.1 Wind Loading

Design and fabricate door assembly to withstand the wind loading pressure of at least 37.5 pounds per square foot with a maximum deflection of 1/120 of the opening width. Provide test data showing compliance with ASTM E330.

Sound engineering principles may be used to interpolate or extrapolate test results to door sizes not specifically tested. Ensure complete assembly meets or exceeds the requirements of ASCE 7.

2.2.2 Operational Cycle Life

Design all portions of the door, hardware and operating mechanism that are subject to movement, wear, or stress fatigue to operate through a minimum number of 10 cycles per day. One complete cycle of door operation is defined as when the door is in the closed position, moves to the fully open position, and returns to the closed position.

2.3 OVERHEAD COILING DOORS

2.3.1 Curtain Materials and Construction

Provide curtain slats fabricated from Grade A steel sheets conforming to ASTM A653/A653M, with the additional requirement of a minimum yield point of 33,000 psi. Provide sheets, galvanized in accordance with ASTM A653/A653M and ASTM A924/A924M.

Provide slats filled with manufacturer's standard thermal insulation complying with maximum flame-spread and smoke-developed indexes of 75 and 450, respectively, according to ASTM E84. Enclose insulation completely within slat faces on interior surface of slats.

2.3.2 Insulated Curtains

Form Curtains from manufacturer's standard shapes of interlocking slats.

Supply slat system with a minimum R-value of 4 when calculated in accordance with ASHRAE FUN IP. Slats to consist of a urethane core not less than 11/16 inch thick, completely enclosed within metal facings. Ensure the exterior face of slats are the same gauge as specified for curtains.

Select an interior face not lighter than 0.0219 inches. The insulated slat

SECTION 08 33 23 Page 6 assembly requires a flame spread rating of not more than 25 and a smoke development factor of not more than 50 when tested in accordance with

ASTM E84.

2.3.3 Curtain Bottom Bar

Install curtain bottom bars as pairs of angles from the manufacturer's standard steel, stainless and aluminum extrusions not less than 2.0 by 2.0 inches by 0.188 inch. Ensure steel extrusions conform to ASTM A36/A36M.

Stainless steel extrusions conforming to ASTM A666, Type 304. Aluminum extrusions conforming to ASTM B221. Galvanize angles and fasteners in accordance with ASTM A653/A653M and ASTM A924/A924M. Coat welds and abrasions with paint conforming to ASTM A780/A780M.

2.3.4 Locks

Provide end and/or wind locks of Grade B cast steel conforming to ASTM A27/A27M, galvanized in accordance with ASTM A653/A653M, ASTM A153/A153M and ASTM A924/A924M. Secure locks at every other curtain slat.

2.3.5 Weather Stripping

Ensure weather-stripping at the door-head and jamb is 1/8-inch thick sheet of natural or neoprene rubber with air baffles. Secure weather stripping to the insides of hoods with galvanized-steel fasteners through continuous galvanized-steel pressure bars at least 5/8-inch wide and 1/8-inch thick.

Include weatherseal for interior side guide.

Ensure threshold weather-stripping is 1/8-inch thick sheet natural or neoprene rubber secured to the bottom bars.

Provide weather-stripping of natural or neoprene rubber conforming to

ASTM D2000.

***AMENDMENT 0002***

2.3.6 Locking Devices

Ensure slide bolt engages through slots in tracks for locking by padlock, located on both left and right jamb sides, operable from coil side.

Provide a locking device assembly which includes cylinder lock, spring-loaded dead bolt, operating handle, cam plate, and adjustable locking bars to engage through slots in tracks.

Provide chain lock keeper which suitable for a standard padlock.

2.3.7 Safety Interlock

Equip power-operated doors with safety interlock switch to disengage power supply when door is locked.

***AMENDMENT 0002***

2.4 HARDWARE

Ensure all hardware conforms to ASTM A153/A153M, ASTM A307, ASTM F568M, and

ASTM A27/A27M.

SECTION 08 33 23 Page 7

2.4.1 Guides

Fabricate curtain jamb guides from the manufacturer's standard angles or channels of same material and finish as curtain slats unless otherwise indicated. Provide guides with sufficient depth and strength to retain curtain, and to withstand loading. Ensure curtain operates smoothly. Slot bolt holes for track adjustment.

2.4.2 Equipment Supports

Fabricate door-operating equipment supports from the manufacturer's standard steel shapes and plates conforming to ASTM A36/A36M, galvanized in accordance with ASTM A653/A653M and ASTM A924/A924M. Size the shapes and plates in accordance with the industry standards for the size, weight, and type of door installation.

2.5 COUNTERBALANCING MECHANISM

Counterbalance doors by means of manufacturer's standard mechanism with an adjustable-tension, steel helical torsion spring mounted, around a steel shaft and contained in a spring barrel connected to top of curtain with barrel rings. Use grease-sealed or self-lubricating bearings for rotating members.

2.5.1 Brackets

Provide the manufacturer's standard mounting brackets with one located at each end of the counterbalance barrel conforming to ASTM A48/A48M. Provide brackets of either cast iron or cold-rolled steel.

2.5.2 Counterbalance Barrels

Fabricate spring barrel of manufacturer's standard hot-formed, structural-quality, welded or seamless carbon-steel pipe, conforming to ASTM A53/A53M. Ensure the barrel is of sufficient diameter and wall thickness to support rolled-up curtain without distortion of slats. Limit barrel deflection to not more than 0.03 inch per foot of span under full load.

2.5.2.1 Spring Balance

Provide an oil-tempered, heat-treated steel helical torsion spring assembly designed for proper balance of door. Ensure that effort to operate manually operated units does not exceed 25 lbs. Provide wheel for applying and adjusting spring torque.

2.5.3 Spring Balance

Install one or more oil-tempered, heat-treated steel helical torsion springs within the barrel, capable of producing sufficient torque to assure easy operation of the door curtain. Provide and size springs to counterbalance weight of curtain, with uniform adjustment accessible from outside barrel. Secure ends of springs to barrel and shaft with cast-steel barrel plugs.

2.5.4 Torsion Rod for Counter Balance

Fabricate rod from the manufacturer's standard cold-rolled steel, sized to hold fixed spring ends and carry torsional load.

SECTION 08 33 23 Page 8

***AMENDMENT 0002***

2.6 ELECTRIC DOOR OPERATORS

Provide electrical wiring and door operating controls conforming to the applicable requirements of NFPA 70.

Electric door-operator assemblies needs to be the sizes and capacities recommended and provided by the door manufacturer for specified doors.

Furnish complete assemblies with electric motors and factory-prewired motor controls, starter, gear reduction units, solenoid-operated brakes, clutch, remote-control stations, manual or automatic control devices, and accessories as required for proper operation of the doors.

Design the operators so that motors may be removed without disturbing the limit-switch adjustment and affecting the emergency auxiliary operators.

Provide a manual operator of crank-gear or chain-gear mechanisms with a release clutch to permit manual operation of doors in case of power failure. Arrange the emergency manual operator so that it may be put into and out of operation from floor level, and its use does not affect the adjustment of the limit switches. Provide an electrical or mechanical device that automatically disconnects the motor from the operating mechanism when the emergency manual operating mechanism is engaged.

2.6.1 Door-Operator Types

Provide an operator mounted to the right or left door head plate with the operator on top of the door-hood assembly and connected to the door drive shaft with drive chain and sprockets.

2.6.2 Electric Motors

Provide motors which are the high-starting-torque, reversible, constant-duty electrical type with overload protection of sufficient torque and horsepower to move the door in either direction from any position.

Ensure they produce a door-travel speed of not less than 8 nor more than 12 inches per second without exceeding the horsepower rating.

Provide motors which conform to NEMA MG 1 designation, temperature rating, service factor, enclosure type, and efficiency to the requirements specified.

2.6.3 Motor Bearings

Select bearings with bronze-sleeve or heavy-duty ball or roller antifriction type with full provisions for the type of thrust imposed by the specific duty load.

Pre-lubricate and factory seal bearings in motors less than 1/2 horsepower.

Equip motors coupled to worm-gear reduction units with either ball or roller bearings.

Equip bearings in motors 1/2 horsepower or larger with lubrication service fittings. Fit lubrication fittings with color-coded plastic or metal dust caps.

SECTION 08 33 23 Page 9

In any motor, bearings that are lubricated at the factory for extended duty periods do not need to be lubricated for a given number of operating hours. Display this information on an appropriate tag or label on the motor with instructions for lubrication cycle maintenance.

2.6.4 Motor Starters, Controls, and Enclosures

Provide each door motor with: a factory-wired, unfused, disconnect switch;

a reversing, across-the-line magnetic starter with thermal overload protection; 120-volt operating coils with a control transformer limit switch; and a safety interlock assembled in a NEMA ICS 6 type enclosure as specified herein. Ensure control equipment conforms to NEMA ICS 2.

Provide adjustable switches, electrically interlocked with the motor controls and set to stop the door automatically at the fully open and fully closed position.

2.6.5 Control Enclosures

Provide control enclosures that conform to NEMA ICS 6 for general purpose NEMA Type 1.

2.6.6 Transformer

Provide starters with 230/460 to 115 volt control transformers with one secondary fuse when required to reduce the voltage on control circuits to 120 volts or less. Provide a transformer conforming to NEMA ST 1.

2.6.7 Safety-Edge Device

Provide each door with a pneumatic safety device extending the full width of the door and located within a U-section neoprene or rubber astragal, mounted on the bottom rail of the bottom door section. Device needs to immediately stop and reverse the door upon contact with an obstruction in the door opening during downward travel and cause the door to return to full-open position. A safety device is not a substitute for a limit switch.

Connect safety device to the control circuit through a retracting safety cord and reel.

2.6.8 Remote-Control Stations

Provide interior remote control stations which are full-guarded, momentary-contact three-button, heavy-duty, surface-mounted NEMA ICS 6 type enclosures as specified. Mark buttons "OPEN," "CLOSE," and "STOP." Ensure the "CLOSE" button requires a constant pressure to maintain the closing motion of the door. When the door is in motion and the "STOP" button is pressed, ensure the door stops instantly and remains in the stopped position. From the stopped position, the door may then be operated in either direction.

2.6.9 Speed-Reduction Units

Provide speed-reduction units consisting of hardened-steel worm and bronze worm gear assemblies running in oil or grease and inside a sealed casing, coupled to the motor through a flexible coupling. Drive shafts need to rotate on ball- or roller-bearing assemblies that are integral with the unit.

SECTION 08 33 23 Page 10

Provide minimum ratings of speed reduction units in accordance with AGMA provisions for class of service.

Ground worm gears to provide accurate thread form; machine teeth for all other types of gearing. Surface harden all gears.

Provide antifriction type bearings equipped with oil seals.

2.6.10 Chain Drives

Provide roller chains that are a power-transmission series steel roller type conforming to ASME B29.400, with a minimum safety factor of 10 times the design load.

Heat-treat or otherwise harden roller-chain side bars, rollers, pins, and bushings.

Provide high-carbon steel chain sprockets with machine-cut hardened teeth, finished bore and keyseat, and hollow-head setscrews.

2.6.11 Brakes

Provide 360-degree shoe brakes or shoe and drum brakes. Ensure the brakes are solenoid-operated and electrically interlocked to the control circuit to set automatically when power is interrupted.

2.6.12 Clutches

Ensure clutches are either the 4-inch diameter, multiple face, externally adjustable friction type or adjustable centrifugal type.

2.6.13 Weather/Smoke Seal Sensing Edge

Provide automatic stop control by an automatic sensing switch within neoprene astragal extending the full width of door bottom bar.

Provide an electric sensing edge device. Ensure the door immediately stops downward travel when contact occurs before door fully closes. Provide a self-monitoring wireless sensing edge connection to the motor operator;

eliminating the need for a physical traveling electric cord connection between bottom bar sensing edge device and motor operator. Supervised system alters normal door operation; preventing damage, injury or death due to an inoperable sensing edge system.

***AMENDMENT 0002***

2.7 SURFACE FINISHING

Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.

Noticeable variations in the same metal component are not acceptable.

Variations in appearance of adjoining components are acceptable if they are within the range of approved samples and are assembled or installed to minimize contrast.

PART 3 EXECUTION

***AMENDMENT 0002***

SECTION 08 33 23 Page 11

3.1 GENERAL

Install overhead coiling door assembly, anchors and inserts for guides, brackets, motors, switches, hardware, and other accessories in accordance with approved detail drawings and manufacturer's written instructions.

Upon completion of installation, ensure doors are free from all distortion.

Install overhead coiling doors, motors, hoods, and operators at the mounting locations as indicated for each door in the contract documents and as required by the manufacturer.

Install overhead coiling doors, switches, and controls along accessible routes in compliance with regulatory requirements for accessibility and as required by the manufacturer.

***AMENDMENT 0002***

3.2 ACCEPTANCE PROVISIONS

After installation, adjust hardware and moving parts. Lubricate bearings and sliding parts as recommended by manufacturer to provide smooth operating functions for ease movement, free of warping, twisting, or distortion of the door assembly.

Adjust seals to provide weather-tight fit around entire perimeter.

Engage a factory-authorized service representative to perform startup service and checks according to manufacturer's written instructions.

***AMENDMENT 0002***

Test the door opening and closing operation when activated by controls or alarm-connected fire-release system. Adjust controls and safeties. Replace damaged and malfunctioning controls and equipment. Reset door-closing mechanism after successful test.

***AMENDMENT 0002***

Test and make final adjustment of new doors at no additional cost to the Government.

3.2.1 Maintenance and Adjustment

Not more than 90 calendar days after completion and acceptance of the project, examine, lubricate, test, and re-adjust doors as required for proper operation.

3.2.2 CLEANING

Clean doors in accordance with manufacturer's approved instructions.

3.3 OPERATION AND MAINTENANCE

Submit 6 copies of the Operation and Maintenance Manuals 30 calendar days prior to testing the Overhead Coiling Door Assemblies. Update and resubmit data for final approval no later than 30 calendar days prior to contract completion.

Provide operation and maintenance manuals which are consistent with

SECTION 08 33 23 Page 12 manufacturer's standard brochures, schematics, printed instructions, general operating procedures, and safety precautions. Provide test data that is legible and of good quality.

-- End of Section --

SECTION 08 33 23 Page 13

AMENDMENT 0002 (SC-00002-4P)
TECHNICAL SUMMARY OF CHANGES
SECTION 01 33 00 - ENG Form 4288
SECTION 08 33 23 - OVERHEAD COILING DOORS