Salient Characteristics - Temporary Warehouse Shelter Tents

Tent Structure (2 each):

Tent will be placed on a concrete slab.

Width: between 15 meters and 20 meters Length: between 25 meters and 30 meters Note: Ideal size of the two tents should be around 30 meters x 15 meters

Side height: between 4 meters and 5 meters

Bay distance: between 4.5 meters and 5.5 meters

Area: 450 square meters per tent

Be fully engineered and designed to meet site specific international wind and snow load requirements.

(Wind load: Must withstand wind load of at least 100 Kilometers/hour) (Snow load: Must withstand snow load of at least 75 Kilograms/meter)

Frame:

Made of steel, or hard Polyvinyl Chloride (PVC).

Anchored to the concrete with heavy duty anchors.

Frame can be non-insulated, thermo-insulated or composite steel roofed designs.

All components used (roofs and walling systems) need to be designed to comply with international fire safety codes.

Roof:

It can be non-insulated, thermo-insulated or composite steel roofed designs.

Side Paneling:

Made of hard PVC, metal or hard structure water, wind, snow resistant.

Doors:

It must include 2 roller shutter doors on the east and west side of the tent.

It must include emergency crank handles and safety against unrolling or fall arrester.

It must include 2 personnel doors on the east and west side of the tent.

Overall Requirements:

Must be designed to be installed between Aug – Sep 2019 and must be able to sustain being in place for at least 36-48 months The Structure must be able to be extended or modified if needed. .

Commercial warranty must be provided.

***This requirement includes Installation and dismantle.

Roller Shutter Door Composite PVC Hard wall Thermo PVC Roof Composite PVC Hard wall Roller Shutter Door Personnel Door