This document is an attachment detailing the requirements for a beverage counter equipment construction as part of a federal contract opportunity. The attachment provides a comprehensive description of the desired beverage counter, including specifications for the construction, materials, dimensions, and features. Key details include:
The beverage counter is a custom-designed L-shaped stationary unit, partially against a wall, with a bay for existing tray/flatware dispensers and a backwall. It is to be constructed with a sturdy stainless-steel frame and base, laminated pressed wood top with cutouts for urn drains and rack dispensers, and decor laminate panels. The counter includes features such as a tray slide, swing doors for access, and provisions for water/drain lines and electrical connections. Specific dimensions and other technical requirements are provided. The related federal contract opportunity is for "Food Service Equipment- Beverage Counters" with the Department of the Army Materiel Command Army Contracting Command as the procuring agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 1_RIT_Counter_Beverage_(middle).pdf | ||
| Attachment 3_RIT_Counter_Beverage_(right).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Description:
1 each Equipment Construction:
may not allow the migration of deleterious substances or impart colors, odors, or tastes to FOOD and under normal use conditions shall be–
(A) Safe;
(B) Durable, CORROSION-RESISTANT, and nonabsorbent;
(C) Sufficient in weight and thickness to withstand repeated WAREWASHING;
(D) Finished to have a SMOOTH, EASILY CLEANABLE surface; and
(E) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Beverage Counter Main Line LEFT:
L‐Shape stationary.
Partially against wall - 8700mm (+/- 10mm).
Partially with bay for 3 EA existing tray/flatware dispenser and backwall.
Based on current layout, custom‐designed and manufactured to customer requirements.
4 existing built‐in rack dispensers (racks dispensers 500x500mm).
4 built‐in stainless-steel urn drains 700x220mm (+/- 5mm) with perforated prism grates‐ incl. cut‐out in laminate top.
Single sided full width tray slide in laminate top with ABS edges on solid brackets and with protected corners Underneath with open stainless-steel base covered on front and sides with standard décor laminate panel from House Collection.
Base with swing doors on customer side made from décor laminate panels.
Bay for tray/flatware dispenser covered with stainless-steel panels on inside.
Backwall on segments – with glass sneezeguards 400mm high and mounted on stainless-steel posts with brackets (overall length 6200mm).
Base frame constructed of stainless-steel tubing for extra strength.
Stainless-steel kick base 150mm on customer front and visible sides/back.
Along wall with special design for cable channel (conduits) like current set up – manufactured in stainless-steel and mounted on back wall above countertop for ease of use and reaching.
Includes total of (8) electric outlets/receptacles (230V/400V) in conduit.
Supply of water and drain from below to include sufficient number of cutouts in laminate top to run necessary water/drain lines into base.
Includes electric and water/drain connections to existing building supply points (to be made available by Warrior Restaurant (WR).
Counter Beverage Station (Left) Manufactory:
Model No.
NA
NA
Base Construction/Support Substructure:
Extra strong and sturdy welded frame (40x20x1.5 tube) in stainless-steel.
Open base to allow running of water/drain lines.
Stainless-steel kick base 150mm.
Complete front side with swing doors for easy access.
Visible sides and back with holders to mount décor laminate panels without tools.
top made of laminated pressed wood except for (4) urn drains and (4) rack dispensers.
Underneath soft drink dispenser with 2 stainless steel shelves for storage of bag‐in‐box containers rest of base is open to allow easy access to water/drain lines and supply points.
Tray Slide:
Front‐mounted and made from pressed wood laminated and mounted on stainless steel brackets tubular.
350mm (+/- 10mm) deep single‐sided mounted on extra heavy brackets.
Brackets securely fastened on base frame construction style from House Collection to match current style.
Décor Front & Left/Right Side:
Style of choice from House Collection (single décor panel) Minimum of 19mm pressed wood particle carrier board – all sides covered with laminate décor.
Doors included; panels mounted on base without tools – easy to take out to access interior of serving line counter.
Left and right side with full panel, corner panels, flat panel design – without design pattern or decorations, partially backside open against wall and stainless-steel bay inside tray dispenser bay.
Safety Glass sneezeguards 400mm (+/- 10mm) on part that into dining room.
Décor Laminate on Top:
From House Collection or matching current décor.
Surface top with (4) urn drains and (3) cut outs for rack dispensers.
Minimum of 30mm thick INCLUDES SUFFICIENT CUTOUTS to run water/drain lines of countertop equipment into counter base – exact locations to be determined ARO at site visit (if necessary to offer on quote).
Disconnecting existing Beverage Counter:
For transport, the existing beverage counters must be disconnected from electricity and water and separated into transportable parts.
*Site visit optional to take measurements of existing lines and space locations and match color with existing facility beverage counter.
Exterior Dimension:
wxdxh: 11000/3900x900/1250x900mm (+/-10mm)
Installation:
Ready for Operation, Work performed during regular working hours Mon – Fri 0800-1500.