This document is a product specification for seven (7) special steel doors required for the Structural Live Fire Training System (SLFTS) at USAG Ansbach, 91522 Ansbach, Germany.
The key details are:
- The SLFTS is a prefabricated three-story steel building used for live fire training of firefighters, equipped with propane-powered fire simulation probes.
- Seven (7) existing doors need to be replaced with new doors meeting specific requirements for heat and water exposure in a live fire training system.
- The required door dimensions are 2100 x 900 mm, with an internal door frame made of 50 x 50 x 3 mm corrosion-protected profile steel tubes.
- The doors shall be planked with 2 mm galvanized sheet metal, insulated inside with 50 mm rock wool, and equipped with spring closure, hinges, door handles, and pressure ball closure device.
- The new doors must be delivered with a folded 3 mm corrosion-protected sheet steel frame and primed in beige color.
- The contract includes dismantling and disposal of the existing doors and frames, and installation of the new doors and frames.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912PB24Q3010 Steel Doors.pdf | ||
| W912PB24Q3010 Picture of old steel doors.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Special Steel Doors for Structural Live Fire Training System USAG Ansbach, 91522 Ansbach Germany
Product Specificatons:
The Structural Live Fire Training System at USAG Ansbach, 91522 Ansbach, Germany is a Prefab three story steel building manufacture by WHP Training Towers, USA. The building is equipped with propane powered fire simula�on probs which cra�ng realist fire scenarios to provide training environment for live fire training of fire fighters. Seven (7) Exis�ng doors need to get replaced with new doors. Therefore, the contractor shall provide:
• Seven (7) doors for Structural Live Fire Training System mee�ng specific requirement of heat and water exposure of a live fire training system.
• Dimensions of the doors: 2100 x 900 mm.
• Internal door frame made of corrosion protected profile steel tubes 50 x 50 x 3 mm.
• Door shall be:
- planked with 2 mm galvanized sheet metal, insulated inside with 50 mm rock wool.
- equipped with spring closure, minimum of 3 hinges, door handle inside and outside and pressure ball closure device.
• Doors need to be:
- delivered included folded frame made of 3 mm corrosion protected sheet steel.
- primed beige.
• Dismantling of seven (7) exis�ng doors including door frames. Disposal of exis�ng doors and frames.
• Installa�on of seven (7) new doors inclusive the frames.
This contract shall include all costs associate like, but not limited to travel, lodging etc.
File details come from the government source that posted it. Updated .