05_Drawing-Sheet_5.pdf
PDF 131 KB Posted
- Attached to
- Modify CPQC (Combat Pistol Qualification Course) Range 122, USAG Bavaria, Grafenwoehr Training Area, Germany
- Solicitation number
- W912PB-19-B-8002
About this file
Drawing-Sheet 5
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 03_Amendment_0001.pdf | ||
| 03_1_Solicitation_W912PB19B8002-0001.pdf | ||
| 03_2_Amendment_instructions.docx | DOCX document | |
| 01_Cover_Letter.pdf | ||
| 05_Drawing-Sheet_1.pdf | ||
| 05_Drawing-Sheet_3.pdf | ||
| 05_Drawing-Sheet_4.pdf | ||
| 04_Attachment_I,_Specification_18Apr19.pdf | ||
| 05_Drawing-Sheet_2.pdf | ||
| 02_Bid_Label.docx | DOCX document | |
| 03_Solicitation_W912PB19B8002.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTES / ANMERKUNGEN :
1. ENCLOSURE SHALL BE HIGH-GRADE STEEL, DIMENSIONS: 500mm x 4OOmm x 210mm.
GEHAEUSE AUS EDELSTAHL, ABMESSUNGEN: 500mm x 400mm x 210mm, IP 66, NEMA 4X
DER KASTEN WIRD AUF EINE BETONBODENPLATTE MONTIERT - KASTEN BESTUECKT MIT VIER
ALLE KABELEINFUEHRUNGEN SIND WASSERDICHT, IN EDELSTAHL, AUSZUFUEHREN.
ALL OPENINGS WITHOUT CABLES MUST BE CLOSED WITH PLASTIC BLIND STOPPER
TO BE WATER TIGHT.
ALLE OEFFNUNGEN OHNE KABEL SIND MIT KUNSTSTOFFBLINDSTOPFEN, WASSERDICHT, ZU SCHLIESSEN.
IP 66, NEMA 4X
SCHARNIER
HINGE
SCHARNIER
HINGE
CJB FRONT VIEW
CJB VORDERANSICHT
BOLZEN M8
BOLT M8
CJB TOP VIEW
CJB DRAUFSICHT
CJB SIDE VIEW
CJB SEITENANSICHT
BOLT M5 x 30
BOLZEN M5 x 30
BOLT M5 x 30
BOLZEN M5 x 30
BOLZEN M8
BOLT M8
SCALE 1 : 5
MASSTAB 1 : 5
CJB FRONT VIEW
CJB VORDERANSICHT
NEIGUNG DES KASTEN CA. 1:20
SLOPE OF THE BOX APPR. 1:20
OPENING POWER
OPENING POWER
3. ALL CABLE LEAD-IN TO BE WATER TIGHT, IN STEEL.
DIE MONTAGEPLATTE IST MIT VIER STEHBOLZEN M5 X 30MM ZU BESTUECKEN ZUR
2. SECURE GROUND WIRE TO BOX UNDER AT EXTERIOR BOLT, M8. PROVIDE GROUNDING CONNECTION
OF THE BOX DOOR AND THE BOX ITSELF
ERDLEITER AM AEUSSEREN BOLZEN, M8, DES KASTENS FESTKLEMMEN. ERDUNGSVERBINDUNG ZWISCHEN
GEHAEUSETUER UND DEM GEHAEUSE HERSTELLEN
SEITENANSICHT
SIDE VIEW FRONT VIEW
VORDERANSICHT
TOP VIEW
DRAUFSICHT
SCALE 1 : 10
MASSTAB 1 : 10
INSTALLATION
PROJECT TITLE
SHEET TITLE
DATE
DATE
DATE
DRAWN BY PROJECT ENGR CHECKED BY
DATE PROJECT NO
SHEET
OF
SIGNATURE SIGNATURE
SIGNATURE
Training Area Grafenwoehr GM 31P
SIGNATURE
RES SECTION
ENGINEERING DIV
ERWIN SCHMIEGERERWIN SCHMIEGER
DATE DESCRIPTION DRAWN BY APPROVEDREV NO
USER/RANGE OPERATIONS
RTLPSAFETY
SIGNATURE
DATE DATE
USA GARRISON BAVARIA
JOHN A. HOWARD, C/Engr Div
SCALE
JEFFREY F. ANDERSON, LTC, FA, C/RANGE OPS
USAG BAVARIA/RES BRANCH/ENG DIV
2 GROUNING TERMINALS & ELECTRICAL TERMINALS, 3 POLES, MOUNTED AT A CARRIER RAIL. NOTICE MINIMUM SIZE
OEFFNUNG DATEN
OEFFNUNG ELEKTRO
OEFFNUNG ELEKTRO
OEFFNUNG DATEN
OPENING DATA
OPENING DATA
UM DIE MONTAGE DER VIER GEWINDEBOLZEN M5 X 30MM (PARAGRAPH 5) ZU ERMOEGLICHEN.
DATENKABELSCHIRME SIND ZU ERDEN
CABLE AT THE POINT OF ENTRANCE, IN THE INTERIOR OF THE BOX.
ZU KENNZEICHNEN.
ALLE FREIEN KABELENDEN SIND DAUERHAFT, IM KASTENINNEREN, AN DER EINLASS-STELLE,
5. THE INSTALLATION CARRIER MUST BE EQUIPPED WITH FOUR BOLTS M5 X 30MM FOR
DIE MONTAGEPLATTE IST AUF STEHBOLZEN ZU MONTIEREN UND MIT 12 TRENNKLEMMEN, 2 ERDUNGSKLEMMEN &
ELEKTROKLEMMEN, 3 POLIG, AUF TRAGSCHIENE ZU BESTUECKEN. MINDESTABMESSUNG DER MONTAGEPLATTE BEACHTEN,
4. INSTALLATION CARRIER MUST BE INSTALLED AT BOLTS AND EQUIPPED WITH 12 SEPARATION TERMINALS, EDELSTAHLLASCHEN, MIT BOHRLOCH ZUR MONTAGE AUF DEN BODEN
STEEL SUPPORTS, WITH HOLE FOR MOUNTING TO GROUND
OF THE INSTALLATION CARRIER TO ALLOW THE INSTALLATION OF THE TREADED BOLTS M5 X 30MM (PARAGRAPH 5).
MONTAGEPLATTE
INSTALLATION CARRIER
MONTAGEPLATTE
INSTALLATION CARRIER
FALLS NOETIG, MONTAGEPLATTE MIT AUSSPARUNG ZUR KABELEINFUEHRUNG VERSEHEN.
PROVIDE CUT-OUT ON THE CARRIER FOR CABLE LEAD IN, IF REQUIRED.
INSTALLATION OF AN ADDITIONAL CARRIER FOR ELECTRONIC EQUIPMENT.
MONTAGE EINER ZUSAETZLICHEN MONTAGEPLATTE FUER ELEKTRONIKBAUTEILE.
DATA CABLE JUNCTION BOX (CJB)
DATENKABELANSCHLUSSKASTEN (CJB)
0.3
0.12
0.3
1.7
0.3 0.3
0.1
1.45
5 SIDE VIEW
SEITENANSICHT
FRONT VIEW
VORDERANSICHT
TOP VIEW
DRAUFSICHTSICHT
SCALE 1 : 10
MASSTAB 1 : 10
0.15
0.48 0.97
PERSONNEL TARGET PIT
PERSONENZIELGRUBE
M10 M10
STEEL, 50x10, DIN 1014/1017
U-STEEL, 120, DIN 1026
STEEL, 60x10, DIN 1014/1017
WELDED
WELDEDWELDED
STEEL, 60x10, DIN 1014/1017, WELDED
LIMIT MARKER, METAL CONSTRUCTION
SCHIESSBAHNBEGRENZER, METALLAUFBAU
(by others)
GRAVEL
SCALE 1 : 5
MASSTAB 1 : 5
MASSTAB 1 : 25
SCALE 1 : 25
ERWIN SCHMIEGER, RES DESIGNER
JOHN S. DARLINGTON, SAFETY DIRECTOR
TI-00788-8P1:5, 1:10, 1:25
DETAILS: NEW TARGET EMPLACEMENTS/CABLE JUNCTION BOX CJB/LIMIT MARKER
DETAILS: NEUE ZIELGRUBEN/KABELANSCHLUSSKASTEN CJB/SCHIESSBAHNBEGRENZER
REVIEW: PREFINAL 12 FEB 2019
25 JAN 2019
CONCRETE FOUNDATION
BETONFUNDAMENT
LIMIT MARKER, WOOD
LIMIT MARKER, METAL
ELECTRONIC BOARD
ELEKTRONIKPLATINE
6. REINSTALL ELECTRONIC CONTROL BOARD AND CONNECT POWER AND DATA CABLES
ELEKTRONIKSTEUERUNGSPLATINE WIEDEREINBAUEN UND ELEKTRO- UND DATENKABEL ANSCHLIESSEN
7. MOUNTING OF THE BOX AT CONCRETE BASE - BOX EQUIPPED WITH FOUR HIGH GRADE
8. DATACABLES MUST BE GROUNDED
9. ALL CABLE PIGTAILS WILL BE TAGGED WITH PERMANENT TAGS ATTACHED TO THE
RECEPTACLE COMBINATION
STECKDOSENKOMBINATION
PREFAB CONCRETE L-SHAPE
BETONFERTIGTEIL L-FORM
POTENTIAL EQUALIZATION BUSBAR
POTENTIALAUSGLEICHSSCHIENE
NYY 3x6
WOOD, BEAM 25X15
HOLZBALKEN, 25x15
1.6
TOP VIEW
DRAUFSICHT
SEITENANSICHT
SIDE VIEW
PREFAB CONCRETE ELEMENTS
FERTIGBETONTEILE
MATTHEW R. DAVIS
UMBAU VON CPQC (KAMPFPISTOLEN QUALIFIKATIONSBAHN), SCHIESSBAHN 122, TRUPPENUEBUNGSPLATZ GRAFENWOEHR
MODIFY CPQC (COMBAT PISTOL QUALIFICATION COURSE), RANGE 122, GRAFENWOEHR TRAINING AREA
FINAL SUBMISSION: 28 FEB 2019