QUESTION:

Would you please clarify the following item numbers with pictures of what is currently being used or an item description?

Line Item Item

7) ¾” PJ IPS x MIP

8) ¾” PJ CTS x FIP

10) 2” CPLG CTSXFIP NL

11) 2” CTS Curb/Ball Valve

13) 2” CPLG CTSXMIP NL Pack Joint

14) 2”x1” BRZ Reducer CPLG

18) ¾” B VLV CTSxCTS NL Curb Stop

20) 1” CTS PJ CPLG

ANSWER:

Explanations

7) ¾” PJ IPS x MIP = 3/4inch pack joint iron pipe size X male adapter (PVC fitting)

8) ¾” PJ CTS x FIP = 3/4inch pack joint copper tube size X female adapter (brass compression to female thread)

10) 2” CPLG CTS x FIP NL = 2 Inch coupling copper tube size X female adapter no lead brass (brass compression to female thread)

11) 2” CTS Curb/Ball Valve = 2 inch copper tube size (brass compression curb stop or ball valve)

13) 2” CPLG CTS X MIP NL Pack Joint = 2inch brass compression to male adapter

14) 2”x1” BRZ Reducer CPLG = brass 2inch to 1inch reducing coupling

18) ¾” B VLV CTSxCTS NL Curb Stop = 3/4inchball valve no lead brass curb stop

20) 1” CTS PJ CPLG = 1inch copper tube size pack joint coupling